HomeMy WebLinkAboutCERTIFICATE OF CONFORMANCEI —"
EoSASF
We create chemistry
Certificate of Conformance
MasterAirC AE 90 Admixture (formerly MB-AE 90)
BASF Corporation Air -Entraining Admixture for Concrete
1, Richard Hubbard, Sr. Technical Marketing Specialist for BASF Corporation, Cleveland, Ohio,
certify:
That MasterAir AE 90 admixture is a BASF Corporation Air -Entraining Admixture for concrete;
and
That MasterAir AE 90 and MB AE 90 admixture are the same product having identical
composition, differing only in designation; and
That no calcium chloride or chloride based ingredient is used in the manufacture of MasterAir AE
90 admixture; and
That MasterAlr AE 90 admixture, based on the chlorides originating from all the ingredients used
in its manufacture, contributes less than 0.000068 percent (0.68 ppm) chloride ions by weight of
the cement when used at the rate of 65 ml- per 100 kg (1 fluid ounce per 100 pounds) of cement;
and
That MasterAir AE 90 admixture meets the requirements of ASTM C260, the Standard
Specification for Air -Entraining Admixtures for Concrete, as well as the requirements for air -
entraining admixtures as specified in Corps of Engineers'CRD-C 13 and AASHTO M154.
6�0v-.j j A64 -ff--
Richard Hubbard
Sr. Technical Marketing Specialist
BASF Corporation
Admixtures Systems
23700 Chagrin Boulevard
Cleveland, Ohio 44122
Telephone (216) 839-7500
SCANNED
BY
St. Lucie County
MASTER@
>>BUILDERS
SOLPTIONS
19oSASF
We create chemistry
Certificate of Conformance
MasterGleniuma 7920
BASF Corporation Admixture for Concrete
To Whom It May Concern:
1, Richard Hubbard, Sr. Technical Marketing Specialist for BASF Corporation, Cleveland, Ohio,
certify:
That MasterGlenlurn 7920 admixture is a high -range water -reducing admixture manufactured by
BASF Corporation; and
That no calcium chloride or chloride based ingredient is used in the manufacture of
MasterGlenlum 7920 admixture; and
That MasterGlenium 7920 admixture, based on the chlorides originating from all the ingredients
used in its manufacture, contributes less than 0.00021 percent (2.1 ppm) chloride ions by weight
of the cement when used at the rate of 66 mL per 100 kg (I fluid ounce per 100 pounds) of
cement; and
That MasterGleniurn 7920 admixture meets the requirements for a Type A, Water -Reducing and
Type F, Water -Reducing, High Range Admixture specified in ASTIVI C494/C494M and AASHTO
M194, the Standard Specification for Chemical Admixtures for Concrete, as well as the
requirements for Type A and Type F admixtures as specified in Corps of Engineers' CRD-C 87.
Richard Hubbard
Sr. Technical Marketing Specialist
BASF Corporation
Admixtures Systems MASTER@
23700 Chagrin Boulevard
Cleveland, Ohio 44122 *BUILDERS
Telephone (216) 839-7500 SOLUTIONS
[�IoBASF
We create chemistry
Certificate of Conformance
MasterPozzolith@ 700 Admixture (formerly Pozzolith 700N)
BASF Corporation Water -Reducing Admixture for Concrete
1, Richard Hubbard, Sr. Technical Marketing Specialist for BASF Corporation, Cleveland, Ohio,
certify:
That MasterPozzolith 700 admixture is a BASF Corporation Water -Reducing Admixture for
concrete; and
That Mast6rPozzolith 700 admixture and Pozzolith 70ON admixture are the same product having
identical composition, differing only in designation; and
That no calcium chloride or chloride based ingredient is used in the manufacture of
MasterPozzolith 700 admixture; and
That MasterPozzollth 700 admixture, based on the chlorides originating from all the ingredients
used in its manufacture, contributes less than 0.00060 percent (6.0 ppm) chloride ions by weight
of the cement when used at the rate of 65 ml- per 100 kg (I fluid ounce per 100 pounds) of
cement; and
That MasterPozzollth 700 admixture meets the requirements for a Type A, Water -Reducing,
Type B, Retarding, and Type D, Water -Reducing and Retarding Admixture specified in ASTM
C494/C494M and AASHTO M 194, the Standard Specifications for Chemical Admixtures for
Concrete, as well as the requirements for Type A, Type B and Type D admixtures as specified in
Corps of Engineers'CRD-C 87.
Richard Hubbard
Sr. Technical Marketing Specialist
13ASF Corporation
Admixtures Systems MASTERP
23700 Chagrin Boulevard
Cleveland, Ohio 44122 OBUILDERS
Telephone (216) 839-7500 SOLUTIONS
1�1 o BASF
We create chemistry
Certificate of Conformance
MasterSet@ R 961 Admixture (formerly Pozzolith 961 R)
BASF Corporation Admixture for Concrete
1, Richard Hubbard, Sr. Technical Marketing Specialist for BASF Corporation, Cleveland, Ohio,
certify:
That MasterSet R 961 admixture is a BASF Corporation Set Retarding Admixture for concrete;
and
That MasterSet R 961 and Pozzolith 961 R admixture are the same product having identical
composition, differing only in designation; and
That no calcium chloride or chloride based Ingredient is used in the manufacture of MasterSet R
961 admixture; and
That MasterSet R 961 admixture, based on the chlorides originating from all the ingredients
used in its manufacture, contributes less than 0.00013 percent (1.3 ppm) chloride ions by weight
of the cement when used at the rate of 65 mL per 100 kg (I fluid ounce per 100 pounds) of
cement; and
That MasterSet R 961 admixture meets the requirements for a Type B, Retarding and Type D,
Water -Reducing and Retarding Admixture specified in ASTM C4941C494M and AASHTO M194,
the Standard Specification for Chemical Admixtures for Concrete, as well as the requirements
for Type B and Type D admixtures as specified in Corps of Engineers' CRID-C 87.
Richard Hubbard
Sr. Technical Marketing Specialist
BASF Corporation MAtTER@
Admixtures Systems
23700 Chagrin Boulevard
Cfeveland, Ohio 44122 *BUILDERS
Telephone (216) 839-7500 SO-LUTIONS
E Ei BASF
We create chemistry
February 16, 2016
Project; .
Project location:
Certificate of Conformance
MasterSuree Z 60 Admixture (formerly RheoTEC Z-60)
BASF Corporation Admixture for Concrete
1, Richard Hubbard, Sr. Technical Marketing Specialist for BASF Corporation, Cleveland, Ohio,
certify:
That MasterSure Z 60 admixture is a Workability -Retaining Admixture manufactured by BASF
Corporation; and
That MasterSure Z 60 admixture and RheoTEC Z-60 admixture are the same product having
identical composition, differing only in designation; and
That no calcium chloride or chloride based ingredient is used in the manufacture of MasterSure
Z 60 admixture; and
That MasterSure Z 60 admixture, based on the chlorides originating from all the ingredients used
in its manufacture, contributes less than 0.00007 percent (0.7 ppm) chloride ions by weight of
the cement when used at the rate of 65 mL per 100kg (I fluid ounce per 100 pounds) of cement;
and
That MasterSure Z 60 admixture meets the requirements for a Type S, Specific Performance,
Admixture as specified in Table I of ASTM C494/C494M and AASHTO M194, the Standard
Specifications for Chemical Admixtures for Concrete.
Richard Hubbard
Sr. Technical Marketing Specialist
BASF Corporation
Admixtures Systems
MASTER@
23700 Chagrin Boulevard
Cleveland, Chla 44122
>>'BUILDERS
Telephone (216) 839-7500
SOLLITION-S
9 Ei BASF
We create chemistry
Certificate of Conformance
MasterGlenium@ 7920
BASF Corporation Admixture for Concrete
To Whom It May Concern:
1, Richard Hubbard, Sr. Technical Marketing Specialist for BASF Corporation, Cleveland, Ohio,
certify:
That MasterGlenium 7920 admixture is a high -range water -reducing admixture manufactured by
BASF Corporation; and
That no calcium chloride or chloride based ingredient is used in the manufacture of
MasterGlenium 7920 admixture; and
That MasterGlenium 7920 admixture, based on the chlorides originating from all the ingredients
used in its manufacture, contributes less than 0.00021 percent (2.1 ppm) chloride ions by weight
of the cement when used at the rate of 65 mL per 100 kg (I fluid ounce per 100 pounds) of
cement; and
That MasterGleniurn 7920 admixture meets the requirements for a Type A, Water -Reducing and
Type F, Water -Reducing, High Range Admixture specified in ASTM C494/C494M and AASHTO
M1 94, the Standard Specification for Chemical Admixtures for Concrete, as well as the
requirements for Type A and Type F admixtures as specified in Corps of Engineers'CRD-C 87.
Richard Hubbard
Sr. Technical Marketing Specialist
BASr Corporation
Admixtures Systems MASTERO
23700 Chagrin Boulevard
Cleveland, Ohio 44122 >>BUILDERS
Telephone (216) 639-7500 SOLUTIONS
9 11 BASF
We create chemistry
Certificate of Conformance
MasterPozzolith(D 700 Admixture (formerly Pozzolith 700N)
BASF Corporation Water -Reducing Admixture for Concrete
1, Richard Hubbard, Sr. Technical Marketing Specialist for BASF Corporation, Cleveland, Ohio,
certify:
That MasterPozzolith 700 admixture is a BASF Corporation Water -Reducing Admixture for
concrete; and
That MasterPozzolith 700 admixture and Pozzolith 70ON admixture are the same product having
identical composition, differing only in designation; and
That no calcium chloride or chloride based Ingredient is used in the manufacture of
MasterPozzolith 700 admixture; and
That MasterPozzollth 700 admixture, based an the chlorides originating from all the ingredients
used in its manufacture, contributes less than 0.00060 percent (6.0 ppm) chloride ions by weight
of the cement when used at the rate of 65 mL per 100 kg (11 fluid ounce per 100 pounds) of
cement; and
That MasterPozzollth 700 admixture meets the requirements for a Type A, Water -Reducing,
Type B, Retarding, and Type D, Water -Reducing and Retarding Admixture specified in ASTM
C494/C494M and AASHTO M1 94, the Standard Specifications for Chemical Admixtures for
Concrete, as well as the requirements for Type A-, Type B and Type D admixtures as specified in
Corps of Engineers'CRID-C 87.
(91,,�OAJ j AJ6*4 -W-
Richard Hubbard
Sr. Technical Marketing Specialist
13ASF Corporation
Admixtures Systems MASTER@
23700 Chagdn Boulevard
Cleveland, Ohio 44122 >>BUILDERS
Telephone (216) 839-7500 SOLUTIONS
E o BASF
We create chemistry
Certificate of Conformance
Masterget@ R 961 Admixture (formerly Pozzolith 961 R)
BASF Corporation Admixture for Concrete
1, Richard Hubbard, Sr. Technical Marketing Specialist for BASF Corporation, Cleveland, Ohio,
certify:
That MasterSet R 961 admixture is a BASF Corporation Set Retarding Admixture for concrete;
and
That MasterSet R 961 and Pozzolith 961 R admixture are the same product having identical
composition, differing only in designation; and
That no calcium chloride or chloride based ingredient Is used in the manufacture of MasterSet R
961 admixture; and
That MasterSet R 961 admixture, based on the chlorides originating from all the ingredients
used in its manufacture, contributes less than 0.00013 percent (1.3 ppm) chloride ions by weight
of the cement when used at the rate of 65 mL per 100 kg (1 fluid ounce per 100 pounds) of
cement; and
That MasterSet R 961 admixture meets the requirements for a Type B, Retarding and Type D,
Water -Reducing and Retarding Admixture specified in ASTM C494/C494M and AASHTO M194,
the Standard Specification for Chemical Admixtures for Concrete, as well as the requirements
for Type B and Type D admixtures as specified in Corps of Engineers' CRD-C 87.
6�OAJ j A64 -a:�
Richard Hubbard
Sr. Technical Marketing Specialist
BASF Corporation
Admixtures Systems MASTERO
23700 Chatirin Boulevard
Cleveland, Ohio 44122 >>BUILDERS
Telephone (216) 839-7500 SOLL1110149
[E] o BASF
We create chemistry
February 16, 2016
Project: .
Project location:
Certificate of Conformance
MasterSure@ Z 60 Admixture (formerly RheoTEC Z-60)
BASF Corporation Admixture for Concrete
1, Richard Hubbard, Sr. Technical Marketing Specialist for BASF Corporation, Cleveland, Ohio,
certify:
That MasterSure Z 60 admixture is a Workability -Retaining Admixture manufactured by BASF
Corporation; and
That MasterSure Z 60 admixture and RheoTEC Z-60 admixture are the same product having
identical composition, differing only in designation; and
That no calcium chloride or chloride based ingredient is used in the manufacture of MasterSure
Z 60 admixture; and
That MasterSure Z 60 admixture, based on the chlorides originating from all the ingredients used
in its manufacture, contributes less than 0.00007 percent (0.7 ppm) chloride ions by weight of
the cement when used at the rate of 66 mL per 100kg (11 fluid ounce per 100 pounds) of cement;
and
That MasterSure Z 60 admixture meets the requirements for a Type S, Specific Performance,
Admixture as specified in Table I of ASTM C494/C494M and AASHTO M1 94, the Standard
Specifications for Chemical Admixtures for Concrete.
A4—� lmc—�
Richard Hubbard
Sr. Technical Marketing Specialist
BASF Corporation
Admixtures Systems MASTERO
23700 Chagrin Boulevard
Cleveland, Ohio 44122 >>BUILDERS
Telephone (216) 839�7500 SOLUTIONS