PREIDUCT EVALILIATIC3N PEPr3RT
ENGINEERING EXIFIRIESSO rLxFERT
PRDDU13T EVALUATION REFIORT
August4,2017
Application Number: FL13757.1-R6
EX Project Number: 15-2338
Product Manufacturer Town & Country Industries SQ'A/Vtv
Manufacturer Address: 400 West McNab Road ED
E3)1
Ft. Lauderdale, FL 33309 St. �UUE? Cour7tv
Product Name & Description: 6.8 Accordion Shutter
Large Missile Impact Resistant Accordion Shutter
Scope of Evaluation:
This Product Evaluation Report is being issued In accordance with the requirements of the Florida
Department of Business and Professional Regulation (Florida Building Commission) Rule Chapter LCCC270-,
4N.$, FA.C., for statewide acceptance per Method 1 (d). The product noted above has been tested
and/or evaluated as summarized herein to show compliance with the Florida Building Code Sixth Edition
(2017) and is, for the purpose Intended, at least equivalent to that required by the Code. Re-evaluation of
this product shall be required following pertinent Florida Building Code modifications or revisions.
Substantiating Data:
PRODUCT EVALUATION DOCUMENTS
EX drawing #15-2338 Cited "6.8 Accordion Shutter, sheets 1-13, prepared by Engineering Express,
signed & sealed by Frank L. Bennardo, P.E. is an integral part of this Evaluation Report.
* TEST REPORTS
Uniform state structural performance has been tested in accordance with ASTM OW-02 and TAS 202
test standards per test report(s) #0353-1102-07 (signed and sealed by Vinu J. Abraham, PE) by Hurricane
Test Laboratory LLC (HTL) and test report #98-016 (signed by George Dotzler) by Construction Testing
Corporation (CTC).
Large missile impact resistance and cyclic loading performance have been tested in accordance with
ASTM Ell 886-06 & Ell 996-05 and TAS 201 & 203 test standards Per test report(s) #0353-1102-07, #0353-
0512-09 (signed and sealed by Vinu J. Abraham, PE) by Hurricane Test Laboratory LLC (HTQ and test
report #03-024 (signed and sealed by Yamil G. Kuri, PE) by Constructlori TNestiny DoWration (CTC).
� 1� - p-"
STRUCTURAL ENGINEERING CALCULATIONS -GKg4" I Valid for
Pages 1
Structural engineering calculations have been prepared which 2
evaluate the product based on comparative and/or rational
analysis to qualify the following design criteria: AW
1. Maximum Allowable Spans <1 .3,07 1
3 10
2. Maximum Allowable Design Pressures 3 1.
3. Minimum Glass Separation ;g
Nn
12T" AVENUE SUITE 106, DEERFIELD BEWdV
PHONE: (954) 354-0660 - FAX: (954) 35
ENGINEERINGEXPRESS.COM
2017
Town & Country Industries — 6.8 Accordion Shutter Page 2 of 2
4. Anchor Spacing
5. Anchor Capacity
No 33% Increase in allowable stress has been used in the design of this product.
Separation from glazing is required for use within the HVHZ and essential facilities. An equivalency letter
is provided with this evaluation report for equivalency to ASTM E 1996-09.
Impact Resistance:
Large Missile Impact Resistance has been demonstrated as evidenced in previously listed test reports,
and Is accounted for in the engineering design of this product.
Wind Load Resistance
This product has been designed to resist wind loads as Indicated in the span schedule(s) on the Product
Evaluation Document (i.e. engineering drawing).
Installation
The product listed above shall be installed in strict compliance with the Product Evaluation Document (i.e.
engineering drawing), along with all components noted therein.
The product components shall be of the material specified In the Product Evaluation Document (i.b.
engineering drawing).
Limitations & Conditions of Use:
Use of this product shall be in strict accordance with the Product Evaluaboh*Document (i.e. engineering
drawing) as noted herein.
Ali supporting host structures shall be designed to resist all superimposed loads and shall be of a material
listed in this producrs respective anchor schedule. Host structure conditions which are not accounted for
in this products respective anchor schedule shall be designed for on a site -specific basis by a registered
professional engineer.
AJI components which are permanently Installed shall be protected against corrosion, contamination, and
other such damage at all times.
This product has been designed for use within and outside of the High Velocity Hurricane Zone (HVHZ)
160 SW 12TH AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442
PHONE: (954) 354-0660 - FAX: (954) 354-0443
ENGINEERINGEXPRESS.COM