Loading...
HomeMy WebLinkAboutMISC LETTERSaiw November 9, 2018 AD Dennis Demarco MasTec Network Solutions, LLC E N G IN E E RI N G G RO UP 6100 Broken Sound Parkway, Suite 6 Boca Raton, FL 33487 Subject: Structural Analysis — Antenna Mount (3C) 5', L�l Carrier Designation: AT&T: Hutchinson Island IFA#1001679.1] F.F.01-iT APX Project: '18-0163.68 Site, Information: 8600 S Ocean Drive Jensen Beach, Saint Lucie County, FIL 34957 Latitude 27.3061940 N, Longitude 80.2201111? Y.VjG. Existing Antenna Mount (Worst Case) T' Dear Mr. Demarco: APX Engineering Group, LLC (APX) is pleased to submit this Structural Analysis to determine whether the subject antenna mount is able to support certain worst -case proposed loads. It is our understanding that AT&T, who retained MasTec Network Solutions (MNS), desires to install new telecommunication equipment on the subject mount. This analysis was based on the supporting information listed in Table 2. Our services were performed in accordance with the terms and conditions of the master service agreement between APX and MNS. This report summarizes the results of our findings. The purpose of this analysis is to determine the suitability of the aforementioned structure to support the loading indicated in the attached calculations. This analysis has been performed in accordance With the Florida Building Code based upon an ultimate 3-second gust wind speed of 163 mph using RISA-3D structural software. Based on our analysis, subject to the assumptions and recommendations noted, it is our opinion that the subject structure will support the proposed loading without modification. Members: Pass at 59.3%, Connections: Pass at 8.1 % This report has been prepared for the puirpose-of providing a structural evaluation of the subject structure for the loading conditions indicated. It is intended for the exclusive use of MNS and AT&T. The information, assumptions, and recommendations contained in this report should not be used by others for any purpose without express written authorization from APX We appreciate the opportunity to provide our professional services to you and look forward to continuing our relationship. If we an b f Ili� F o any further assistance, please do not hesitate to contact us. 1"L111 ............ . Sincerely, e %1i � < e, IV APX Engineering Group, LLC 12 % - .0 (P-. SCANNED Z BY St. Lucie County S I - PIP -,L" Z Michael A. Phillips, P.E. . N Chief Engineer 0 AL Florida License #68312 1.84S I a I it 0 %",4 AT&T: Hutchinson Island [FA #1001 6P. Structural Analysis Report Table 1: Criteria Criterion Building Code Description Florida Building Code, 6th Edition (2017) Standard — Loads ASCE 7-10 Minimum Design Loads for Building and Other Structures (FBC 1609.1.1) Standard - Steel AISC LRFD 14th Edition Standard - Concrete ACI 318-14 Risk Category 11 Ultimate Wind Speed 163 mph, 3-Second Gust (FBC Figure 1609.3 (1)) Nominal Wind Speed 126 mph, 3-Second Gust (FBC 1609.3.1) Exposure Category D Live Load 250 lbs Dead Load Equipment Self -Weight Table 2: Supporting Information Date November 5, 2018 Description Site Visit/ Investigation By APX October 10, 2018 Radio Frequency Data Sheet (RFDS) AT&T August 7, 2018 TARP Mount Technical Directive — R9 AT&T November 5, 2012 Construction Drawings [LTE] CALTROP Corporation Various Miscellaneous Information AT&T / MNS Assumptions and Limitations 1 . Information in the supporting documentation that could not be verified by APX personnel is assumed to be correct. 2. All components are assumed to be in adequate condition to carry their full design capacity. 3. The configuration of equipment/appurtenances is assumed to be as specified in this report. 4. Emergency/essential communication equipment will not be supported by this assembly. If any of the above assumptions are not valid or have been made in error, these calculations may be affected, and APX should be allowed to review any new information to determine its effect on the structural integrity of the subject structure. Recommendations 1. Check all bolts for proper tightening in accordance with AISC "Snug -Tight" method prior to installation of proposed equipment. APX Engineering Group, LLC Wind Load - Appuftenance In Accordance Mth ASCE 7-10, Chapter 29 APX Engineering Group, LLC 3400 Lakeside Drive, #525, Miramar, FL 33027 AT"T Hutchinson Island [FA #10016791]. 18-0163.68 M. Phillips, November 2018 A ENGIMEERANG GROUP Design Parameters Page I of 1 Wind Speed, VUR = FIT6q3 mph (Ultimate Wind speed, ASCEFigure 26.5-1A) 700 (ASCE Table 26.9-1) 11.5 (ASCE Table 26.9-1) Exposure=1 D.'I (Exposure Category, ASCE 26.7.3) Z,I, = 7 (ASCE Table 26.9-1) 650 (ASCE Table 26.9-1) (ASCE Eq. 26.9-7) Risk Category = [_Ej (ASCE Table 1.5-1) ZBAR = (ASCE 26.9.4) C = 0.15 (ASCE Table 26.9-1) Q = (ASCE Eq. 26.9-8) Z= (Effective Height) E = 0.13 (ASCE Table 26.9-1) L, = (ASCE Eq. 26.9-9) G = 0.93 (MAX Gust -Effect Factor, ASCE 26.9) K�, Kn, Kd = BSI... (ASCE Table 29.3-1, ASCE 26. B.Z ASCE Table 26.6-1) Cf or C, = B'I'.' (Foxe Coefficients, ASCE 29.5) q, m 0.00256KKtK dV2 (Velocity Pressure, ASCE Eq. 29.3-1) Af = H-W or H-D (Pmjected Area Nonnal to Virind Direction) F = q,GCfAf (Design Mind Foxe, ASCE Eq. 29.5-1 or 2) Wind Load I z I H D R.md Q K. Kt Kd (q� FsIde Wt. (ft) ft) (ft) ? psf) ront Cf F'."'I Appurtenance Type (ft) W Z13AR Z L� 1. 1 FCf Side (lbs) (lbs) (lbs) Kathrein/Scala 800-10964K Panel I-IY5 1 '1.35'1-4.59 4.9 1.7 0.58 N 81 81 727 0.13 0.98 1.51 1�0 0.85 87.3 1.33 1.45 882 304 83.8 55.1 Kathrein/Scala 800-10864K Panel 1.23 0.55 N 81 81 727 0.13 0.99 1.51 1.0 0.85 87.3 1.35 1.44 615 276, Definitions: Panel = Panel or Directional Antenna, Omni = Omni-Direcdonal Antenna, Dish Microwave Dish Antenna, Radio = Remote Radio Unit (RRU), TMA Tower Mounted Amplifier APX Enqin( I M. Phillips I 18-0163.68 Hutchinson Island - Antenna Mount 3D RENDERED VIEW SK - 1 Nov �, 2018 at 3:50 PM Hutchinson Island -Antenna Moun APX Engineering Group, I M. Phillips I 18-0163.68 Hutchinson Island - Antenna Mount JOINT NUMBERS SK-2 Nov 8, 201 Bat 3:51 PM Hutchinson Island - Antenna Moun �c� �y &Idmn APX Engineering Group, SK-3 M. Phillips Hutchinson Island -Antenna Mount Nov 8, 2018 at 3:51 PM 18-0163.68 MEMBER NUMBERS Hutchinson Island -Antenna Moun APX Engineering Group, ... SK-4 M. Phillips Hutchinson Island - Antenna Mount Nov 8, 2018 at 3:51 PM 18-0163.68 MEMBER SIZES Hutchinson Island - Antenna Moun Vw FiN 18-0163.68 Hutchinson Island - Antenna Mount MEMBER LENGTHS SK-5 Nov 8, 2018 at 3:51 PM Hutchinson Island - Antenna Mc APX Enqin( I M. Phillips I 18-0163.68 Hutchinson Island - Antenna Mount DEAD LOAD SK - 6 Nov 8, 2018 at 3:52 PM Hutchinson Island - Antenna Moun APX Engineering Group, M. Phillips 18-0163.68 Hutchinson Island -Antenna Mount LIVE LOAD (WORST SK-7 Nov 8, 2018 at 3:52 PM Hutchinson Island -Antenna Moun APX Enqin( I M. Phillips I 18-0163.68 Hutchinson Island - Antenna Mount WIND AT FRONT SK-8 Nov 8. 2018 at 3:52 PM Hutchinson Island -Antenna N APX EnqinE I M. Phillips I 18-0163.68 Hutchinson Island - Antenna Mount WIND AT SIDE SK-9 Nov 8, 2018 at 3:52 PM Hutchinson Island - Antenna Mo APX Enqin( I M. Phillips I 18-0163.68 Hutchinson Island - Antenna Mount UNITY CHECK SK - 10 Nov 8. 2018 at 3:52 PM Hutchinson Island - Antenna Moun m APX Engineedng I M. Phillips 18-0163.68 Hutchinson Island -Antenna Mount SHEAR CHECK SK- 11 Nov 8, 2018 at 3:53 PM Hutchinson Island - Antenna Moun Company APX Engineering Group, LILC Nov 8, 2018 Designer M. Phillips 3:63 PM 111RISAJob Number 18-0163.68 Checked By: T E C H N 0 L 0 G I E S Model Name Hutchinson Island -Antenna Mount (Global) Model Settings Display Sections for Member CaIcs 5 Max Internal Sections for Member CaIcs 97 Include Shear Deformation? Yes Increase Nailing Capacity for Wind? Yes Include Warping? Yes Trans Load l3twn Intersecting Wood Wall? Yes Area Load Mesh (inA2) 144 Merqe Tolerance (in) .12 P-Delta Analysis Tolerance 0.50% Include P-Delta for Walls? Yes Automatically Iterate Stiffness for Walls? No Max Iterations for Wall Stiffness 3 Gravity Acceleration (ft/seCA2) 32.2 Wall Mesh Size (in) 12 Eigensolution Conver-gence Tol. ME-) 4 K a It ef!ic L Y !Global Aber Orientation Plane I Static Solver 1 Soarse Accelerated I Dynamic Solver I Accelerated Solver Hot Rolled Steel Code AISC 14th(360-10): LRFD Adoust.Stiffness? Yes(Iterative) RISAConnection Code AISC 14th(360-10): LRFD Cold Formed Steel Code None Wood Code None Wood Temperature < 10OF Concrete Code None Masonry Code None Aluminum Code None - Building Number of Shear Regions 4 Region'Spacing Increment (i 4 Biaxial Column Method PCA Load Contour Parma Beta Factor (PCA) .65 Concrete Stress Block Rectangular Use Cracked Sections? Yes Use Cracked Sections Slab? Yes Bad Framing Warnings? No Unused Force Warnings? Yes Min I Bar Dann. Spacing? No Concrete Reber Set REBAR SET ASTMA615 Min % Steel for'Column' 1 Max % Steel for Column 8 RISA-3D Version 14.0.1 [TA ... \ ... \ ... \ ... \3C installtion [2018]kHutchinson Island -Antenna Mount.r3d] Page I Company APX Engineering Group, LLC Nov 8, 2018 Designer M. Phillips 3:53 PM 111RESA Job Number 18-0163.68 Checked By:_ T E C H N 0 L 0 G I E S Model Name Hutchinson Island -Antenna Mount (Global) Model Settings, Continued Seismic Code ASIDE 7-10 Seismic Base Elevation (ft) Not Entered Add Base Weight? No ctx .035 Ct z .035 T X (sec) Not Entered T Z (sec) Not Entered R X 8.5 R Z 8.5 Ct Exp. X .75 Ct Exp. Z .75 SDI I SDS 1 S1 I TL (sec) Not Entered Risk Cat I or 11 DM Z 1 Dnn X I Rho Z I Rho X I Envelope AISC 14th(360-10): LRFQ Steel Code Checks me ler P�e.o , Cole L, 1�epr,,, jol n -.9 6- m 'a C Oc' 0 1-- 1 0� LO 'i'Lf' I Sp -.11 U T PI... 1 5- 2 Y"I 9 2'0 ;66.5.1 o0l NO 24565' 12'2559.512-Ml-lb I I IM NT PIPE 593 11.75 751 Ill Load Combinations Dp-qrrinflon S P S 13 Fa B - F2 13 Fa R Fn R Fa R F2 B Fa . 13 Fa B F2 - R.- Fa -- Service 1.ODL+ 0.6WL (0 deg) RISA-31D Version 14.0.1 [TA ... \ ... \ ... k ... \3C installtion [2018]\Hutchinson Island - Antenna Mount.r3d] Page 2 111MACompany APX Engineering Group, LLC Nov 8, 2018 Designer M. Phillips 3:53 PM Job Number 18-0163.68 Checked By:_ Y 0 L 0 0 1 E S Model Name Hutchinson Island -Antenna Mount Load Combinations (Continued) Descrintion S... P... S­ B­ Fa- 13... Fa... B... Fa... 8... Fa... R... Fa... B... Fa... 9... Fa... 8... Fa... B... Fa... B... Fa Joint Loads and Enforced Dis-olacements (BLC 1 : Dead Load) 111, LIM Direction Magn[tuder(lb I -in). (in.rad). (IbV21ft lb i I ANTENNA L Y 1 -83.8 Joint Loads and Enforced Displacements (BLC 2: Live Load) Join Label L.D_M Direction Magnitudef(lb.1 -in), (in.rad). (lb*s42/ft, b *SA 2!ft)] I i I N' 5 1 L I Y 1 -250 Joint Loads and Enforced Displacements (BLC 3: Wind Front) J Lab I L.D M Dimection Magnitudel(lb.1 -in), (in.rad). flb*SA2/ft, Ilb A 7:1 1 1 1 N ENNA I L X 1 882 7a Joint Loads and Enforced Displacements (BLC 4: Wind Side) Jginj Let a D M Dimection Magnitudefflb.1 -in), (in.rad). (lb*SA2/_ft, Ib.s A 2*ft)l 1 1 ANTENNA L Z 304 Envelope Member Section Forces Mpmhpr qAr. Ayiniphl I Q. v.Rhpnrrlhl I C. 7.RhPnrT1h1 I r. TnrmjR.1I I r v.v momp.ntrlh-inl Lr 7-z MnmantTIh-InI LC 1 MOUNT -PIPE 1 max 0 1 1 .001 1 0 101 0 1 0 1 0 1 2 min 0 1 1 -.001 7 0 4 0 1 0 1 0 1 3 2 max -1.562 13 736.145 7 253.728 4 0 1 3805.919 4 11042.172 1 4 min -2.43 25 -736145 1 -253.728 10 0 1 -3805�919 10 -11042.172 7 5 3 max 513.055 26 883.188 1 304.409 10 0 1 .961 4 Z789 1 6 min 84.791 13 -883.188 7 -304.409 4 0 1 -.961 10 -2.789 7 7 4 max 406.248 26 .077 1 .027 10 0 1 .481 4 1.394 1 8 min 4.686 13 -.077 7 -.027 4 0 1 -.481 10 -1.394 9 5- Max 400 26 .077 1 1 .027 0 0 1 0 1 0 -7 1 10 min 1 0 1 - .077 1 7 _.0 27 A 0 1 1 1 0 1 RISA-3D Version 14.0.1 [T:\ ... \ ... \ ... X ... \3C installtion 12018]\Hutchinson Island - Antenna Mount.r3d] Page 3 Company APX Enginee(ing Group, LLC Nov 8, 2018 Designer M. Phillips 3:53 PM 111RISAJob Number 18-0163.68 Checked By:— N 0 L Model Name Hutchinson Island -Antenna Mount Envelope Joint Reactions Inin# Y rihi I r. y r1hl I r. 7 nhi i n my rih-inl i r. my rih-inl 1 r M7 rlh-inl LC 1 . ..... BOTTOM max ...... 736.145 11 4.859 25 253.728 4 0 1 0 1 0 1 .2 min -736.145 �7 3.124 13 -253.728 10 0 0 1� 0 1 3 TOP max 1618.145 7 521.385 26 557.728 10 0 1 0 1 0 1 4 min -1618J45 1 - 91;039 13 -557.728 E 4 0 �O 1 0 1 5 Totals: max 882 19 525.55 26 304 10 ,6 min -882 13 94.162 13 -304 A RISA-31D Version 14.0.1 [T:\ ... k ... \ ... \ ... \3C installtion [2018]\Hutchinson Island -Antenna Mount.r3d] Page 4 Anchorage Cal:�adty Calculations In Accordance With AISC LRFD 14th Edition AT& APX Engineering Group, LLC Hutchinson Island [FA #10016791], 18-0163.6 3400 Lakeside Drive, #525, Miramar, FL 33027 M. Phillips, November 201 ru-Bolts at Top ASTM A36, 5/8" 0 Tu =F�17R275 lbs (MAX Tension Reaction, Factored) N=L2F (Numbers of Fastener Sections in Tension) Tm� T,, / N (MAX Tension per Fastener) 813 lbs per Bolt V,, = F-8-4-9-� lbs (mAx shear Reaction, Factored) n = =2 (Numbers of Fastener Shear Planes) VM., = V, / n (MAX Shear per Fastener) 424 lbs per Bolt �T, = 10,009 lbs (Fastener Design Tensile Strength, AISC Eq. J3-1) OV, = 6,006 lbs (Fastener Design Shear Strength, AISC Eq. J3-1) f, = 1,383 psi (Fastener Required Shear Stress, AISC J3.7) F',,j = 1.3F,,t - (Frt/�F,,)f, > F,t= 43,500psi (Modified Nominal Tensile Stress, AISC Eq. J3-3a) = 53,477 psi (Thus, Fnt Governs) IIIIR,= 10,009 lbs (FastenerAvailable Tensile Strength, AtSC Eq. J3-2) Tms. -5 �R. OK 8. 1% Stressed in Tension, 7. 1% Stressed in Shear, 8.1% Stressed Combined ru-Bolts at Bottom ASTM A36, 5/8" 0 T,,=F 75-0 Ilbs (MAX Tension Reaction, Factored) N = =2 (Numbers of Fastener Sections in Tension) TM,,,, = T,, / N (MAX Tension per Fastener) 376 lbs per Bolt vu =F-6-777] lbs (MAX Shear Reaction, Factored) n = L2J� (Numbers of Fastener Shear Planes) Vmu = V, / n (MAX Shearper Fastener) 335 lbs per Bolt �T, = 10,009 lbs (FastenerDesign Tensile Strength, AISC Eq. J3-1) �V, = 6,006 lbs (FastenerDesign ShearStrength, AISC Eq. J3-1) f, = 1,093 psi (Fastener Required Shear Stress, AISC J3.7) Fnt = 1.3Fr,t - (F,,t1+F,,)J` , > F,t = 43,500 psi (Modified Nominal Tensile Stress, AISC Eq. J3-3a) = 54,121 psi (Thus, Fnt Governs) �R, = 10,009 lbs (FastenerAvailable Tensile Strength, AISC Eq. J3-2) E N G IN 0 C R ING G,j 0 U r Page 1 of I Existing Wall Thru-Bolts (TYP.) T -41-� V SkM� Tmax :5 �Rn OK 3.7% Stressed in Tension, 5.6% Stressed in Shear, 3.7% Stressed Combined November 9, 2018 06? 19 a Dennis Demarco 4" 12 MasTec Network Solutions, LLC E N G I N E E R I N G G R 0 U P 6100 Broken Sound Parkway, Suite 6 Baca Raton, FL 33487 Subject: Structural Evaluation — Existing Building,(3C) AT&T Site: Hutchinson Island [FA#10016791] Site Address: 8600 S Ocean Drive, Jensen Beach, FIL 34957 APX Project: 18-0163.68 Dear Mr. Demarco: APX Engineering Group, LLC (APX) has completed an evaluation of the effect on loading of the subject structure created by the addition of new equipment. This evaluation was based on published catalog information, information obtained during our site visit, previous site construction drawings, the antenna mount calculations by APX dated November 9, 2018, and information provided by AT&T. The intent of this letter is to assess the effect of the proposed addition of new telecommunication equipment upon the supporting structural system, which include the existing building structure. The proposed antenna equipment loading will impose approximately 18 square feet of project wind area and 550 pounds of weight increase spread over three locations already being occupied by AT&T equipment on the existing structure. The projected wind area increase as a result of the proposed equipment is less than ten percent and the weight increase is negligible in comparison to the weight of the building. In accordance with the Florida Building Code — Existing, 6th Edition (2017), Sections 402.3 and 402.4, these are acceptable limits of load increase. Therefore, based on our evaluation of the above -referenced information, it is our opinion that the subject supporting structure will support the proposed AT&T loading. Should you have any questions or wish to discuss any aspect of this letter, please do not hesitate to contact the undersigned. Sincerely, APX Engineering Group, LLC Michael A. Phillips, P.E. Chief Engineer Florida License #68312 0 No 0 7' /0 /VA RUJIG December 17, 2018 Saint Lucie County Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Subject: Special Inspection Letter of Intent AT&T Site: Hutchinson Island [FA#10016791] Site Address: 8600 S Ocean Drive, Jensen Beach, FL 34957 APX Project: 18-0163.68 Dear Sir or Madam: ap E N G IN E E R,I N G G RO UP APX Engineering Group, LLC (APX) understands that Saint Lucie County requires that, as special inspector for the subject construction project, APX supplies specifications setting forth the procedures to be takenfor the required inspections. The purpose of these inspections will be to determine if the installation of the antenna equipment is in substantial accordance with the approved construction drawings prepared by APX dated December 18, 2018. Such special inspections will be performed in accordance with Section 110. 10.1.1 of the Florida Building Code and will include, but not be limited to, the following: 1. Inspect anchoring, spacing and mounting of the proposed antennas to the existing building structure. 2. Inspect mounting of proposed remote radio units (RRUs) and proposed peripheral equipment to the existing building structure. Copies of the inspections shall be sent to the Building Department on a weekly basis, and the final letter of completion will be provided at the completion of the final Inspection. This letter has been prepared for the purpose of fulfilling the requirements of Saint Lucie County with respect to the specific installation described. It is intended for the exclusive use of Saint Lucie County and AT&T. The information, assumptions and recommendations contained in this letter should not be used by others for any purpose without express written authorization from APX Should you have any questions or wish to discuss any aspect of this letter, please do not hesitate to contact the undersigned. Sincerely, APX Engineering Group, LLC Michael A. Phillips, P.E Chief Engineer Florida License #68312 Inspection Date: October 15, 2019 Saint Lucie County Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FIL 34982 RECEWED OICT/3"O 201 Permitting Department St. Lucie CountV a pA ENGINEERING GROUP Subject: Special Inspection Report 1 of I (Final) [3C] Permit: SLC 1901-0065 AT&T Site: Hutchinson Island (FA# 10016791) Site Address: 8600 South Ocean Drive, Jensen Beach, FIL 34957 APX Project: 18-0163.68 Dear Building Official: APX Engineering Group, LLC (APX) performed a review of construction and close-out documentation of the AT&T telecommunication facility located at the above -referenced site. The purpose of these observations was to inspect the following in accordance with the Florida Building Code, 6th Edition (2017) and the National Electric Code (NEC), 2014 Edition: 1 . Removal of nine existing antennas. 2. Removal of six existing Remote Radio Units (RRUs). 3. Removal of three existing DC-2 surge suppressors. 4. Installation of nine proposed antennas. 5. Installation of nine proposed RRUs. CANIV,�,D 6. Installation of three proposed DC-6 surge suppressors. 7. Installation of proposed power cables. .t By 8. Installation of proposed fiber,cables. I LuCie COMty 9. Installation of proposed grounding system. The installation of the above -mentioned items was visually inspected and compared with the approved construction drawings by APX Engineering Group, LLC dated December 18, 2018. Based on these observations and to the best of my knowledge and belief, the above -described construction of all structural load -bearing components complies with the permitted documents. I Should you have any questions or wish to discuss any aspect of this letter, please do not hesitate to contact the undersigned. 4 Sincerely, APX Engineering Group, LLC Giovanni Hall, E.I. Michael A. Phillips, P.E. Engineering Intern Chief Engineer Florida License #68312 I Lydia Galbraith From: RoreyWanliss <Rorey.Wanliss@mastec.com> Sent: Thursday, February 07, 2019 10:36 AM To: Lydia Galbraith Subject: FW: Report — FL Review—Comments—Noncompliantjrf.pdf, PERM -1,9011-0065 Attachments: SKMEIT—C36419011813550.pcif, BOND 104138345.pdf,, Security Una ent.doc Docs attached for your review and approval. Rorey E Wanliss Site Acquisition Project Manager SFL 6 100 Broken Sound Pkwy Suite 61 Boca Raton, FL 33487 Cell — 954 801-4949 Rorey.waiiIiss@mastee.COMIw)vw.iiiasteenetivorksolutions.com NOTICE: The information contained in this email and any document attached hereto is intended only for the named recipient(s). If you are not the intended recipient, nor the employee or agent responsible for delivering this message in confidence to the intended recipient(s), you are hereby notified that you have received this transmittal in error, and any review, dissemination, distribution or copying of this transmittal or its attachments is strictly prohibited. If you have received this transmittal and/or attachments in error, please notify me immediately by reply e-mail and then delete this message, including any attachments From: Rorey Wanliss Sent: Friday, January 18, 2019 1:45 PM To: 'Lydia Galbraith' <galbraithl@stlucieco.org> Subject: RE: Report—FL—Review—Comments_Noncompliantjrf.pdf, PERMIT 1901-0065 Lydia Please see the attached. Rorey F Wanliss Site Acquisition Project Manager SFL 6100 Broken Sound PkNvy Suite 61 Boca Raton, FL 33487 Cell — 954 801-4949 Rorey.wanliss@mastee.comlwww.mqsteciictivorkqnlutions-colli NOTICE: The information contained in this email and any document attached hereto is intended only for the named recipient(s). If you are not the intended recipient, nor the employee or agent responsible for delivering this message in confidence to the intended recipient(s), you are hereby notified that you have received this transmittal in error, and any review, dissemination, distribution or copying of this transmittal or its attachments is strictly prohibited. If you have received this transmittal and/or attachments in error, please notify me immediately by reply e-mail and then delete this message, including any attachments From: Lydia Galbraith <galbraithl(@stlucieco.org> Sent: Friday, January 11, 2019 1:37 PM To: Rorey Wanliss <Rorey.Wanlissi3i)mastec.conr> Subject: [External] Report_FL—Review—Comments—Noncompliant_jrf.pdf, PERMIT 1901-0065 Attention: This email was sent from someone outside of MasTec. Please use caution when opening attachments or clicking on links in entails which are unexpected or arrive from unknown senders. Rorey,