Loading...
HomeMy WebLinkAboutPLANSat&t RECEVED JAN 0 4 2019 permitting Department St. Lucie county RIVERPARKST. LUCIE COUNTY PLAN REVIEW (FA 10016792) SCANNED BLDG: DATE: Py 1, St. Lucie COunty ELEC */v DATE: 191 PLUMB: 1480 DYER ROAD DATE: PORT ST LUCIE, FL 34952 MECH: DATE: FN 6C, 4T4R PCS, -8WE AWS OVERLAY LOCAL MAP PROPERTY SUMMARY PROJECT DESCRIPTION INDEX OF DRAWINGS "77 C" � As!Q\ I E= 3414-501-0716-000-0 PROPERTY OWNER AMERICAN TOWER SYSTEMS. INC. P.O. BOX 723597 ATLANTA, GA 31139 LATITUDE 27.32451cr N LONGITUDE 80.31123f W ZONING JURISDICTION ST LUCIE COUNTY 1. THE WIRELESS COMMUNICATIONS FACILITY IS NOT INTENDED FOR HUMAN OCCUPANCY. 2. THIS FACILITY DOES NOT REQUIRE POTABLE WATER AND WILL NOT PRODUCE ANY SEWAGE. 3. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. 4. INSTALLATION OF NEW ANTENNA MOUNT (WILL CAUSE THE SITE TO BE OFF —AIR FOR APPROXIMATELY 3 TO 7 DAYS). 5. THE SCOPE OF WORK CONSISTS OF PROPOSING A WIRELESS INSTALLATION: REMOVAL OF (3) EXISTING RRUS (REMOTE RADIO UNITS) INSTALLATION OF (6) NEW RRUS (REMOTE RADIO UNITS) IN ANTENNA AREA INSTALLATION OF (3) NEW RRUS (REMOTE RADIO UNITS) IN SHELTER AREA SHT. NO. DESCRIPTION REV. NO. TI TITLE SHEET 0 T2 GENERAL NOTES 0 — COMPOUND PLAN 0 C2 ELEVATION AND ANTENNA PLANS 0 — C3 DETAILS 0 C4 AN-1 DETAILS ANTENNA SCHEDULE 0 0 El DO ELECTRICAL DETAILS 0 VICINITY MAP DESIGN CRITERIA CODE COMPLIANCE 4-e Ll --4RISK 0 I� ys ITE LOCATION T.. al L v - DESIGN WIND SPEED: 160 MPH (ULTIMATEo 3-SECOND GUST) 124 MPH (NOMINAL. 3-SECOND GUST) EXPOSURE. C CATEGORY: 11 OPEN STRUCTURE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDMONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 1. FLORIDA BUILDING CODE, 6th EDITION (2017). 2. NAT10NAL FIRE PROTECTION ASSOCIATION (NFPA) 70-14. NATIONAL ELECTRICAL CODE, 2014 EDITION. 3. ASCE 7-10. 4. TIA-222-G WITH ADDENDUM 1. 2. 3 & 4 APPUCABLE STANDARDS. 5. UFE SAFETY CODE NFPA-101-2015. 6. FLORIDA FIRE PREVENTION CODE. 6th EDnlON (2017). 7. AMERICAN INSTITLRE OF STEEL CONSTRUCTION (AISC) 360-10 AND 341-10. 8. UNDERWRITERS LABORATORIES (U.I-) APPROVED ELECTRICAL PRODUCTS. 9. LOCAL JURISDICTIONAL REQUIREMENTS. 10. CrrY/COUNTY ORDINANCES. — — RF DESiG N VERIFICATION DESIGN BASED ON RFDS #2104814 REV 0.1 DATED 12/18/17. CONTRACTOR SHALL REQUEST CURRENT RFDS AND CURRENT WORKBOOK FROM MASTEC NETWORK SOLUTIONS CONSTRUCTION MANAGER PRIOR TO CONSTRUCTION 'REV DATE DIMCRIPTION A 5/3/18 PRE11MINARY B 9/6/18 REASED 0 9/11/18 PERMIT APX NO.: 1!-0153.22 F=ECT D By.. C. BELLO CHECKED BY. M. ABBE_, IQ ra- omry 1.' FOR THE PURPOSES OF THESE CONSTRUC-nON DRAWINGS. THE FOLLOWING DEFINITIONS SHALL APPLY: 2. 3. 4. 5. 6. 7. 10. ii. 12. 13. 14. 15. OWNER - AT&T MOBILITY 64GINEER - APX ENGINEERING GROUP, LLC. CONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION) PRIOR TO SUBMITTING HIS BID, THE CONTRACTOR SHALL MSF THE JOB SITE IN ORDER TO (1) VERIFY ALL EXISTING CONDITIONS, (2) CONFIRM WHETHER ALL DIMENSIONS ARE AS SHOWN ON THE PLANS AND (3) CONFIRM WHETHER THE WORK MAY BE ACCOMPLISHED AS SHOWN. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER. A 20-FOOT HORIZONTAL CLEARANCE DISTANCE SHALL BE MAINTAINED FROM ALL EXISTING POWER LINES. THE CONTRACTOR'S USE OF A CONSTRUCTION STAGING AREA SHALL BE COORDINATED WITH THE OWNER WEU. IN ADVANCE OF THE CONSTRUCTION START DATE. LABOR, MATERAL� TOOLS. EQUIPMENT, TRANSPORTATION AND TEMPORARY POWER SERVICES NECESSARY FOR AND INCIDENTAL TO COMPLETION OF ALL WORK SHALL BE PROVIDED AS INDICATED ON THE DRAWINGS AND/OR AS SPECIFIED HEREIN. LABOR AND MATERIALS SHALL BE FURNISHED AS REQUIRED FOR COMPLETE SYSTEMS, INCLUDING ALL ELEMENTS OBVIOUSLY OR REASONABLY INCIDENTAL TO A COMPLETE INSTALLATION. WHETHER OR NOT SPECIFICALLY INDICATED ON THE PLANS. FOR TASKS REQUIRED TO BE PERFORMED BUT NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL NOT START WORK ON SUCH TASKS WITHOUT HAVING RECEIVED WRITTEN AUTHORIZATION FROM THE CONSTRUCTION MANAGER TO PROCEED. THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND EQUIPMENT UNLESS OTHERWISE INDICATED BY DIMENSIONS OR DETAILS. EXACT EQUIPMENT LOCATIONS MAY BE MODIFIED AS REQUIRED BY ACTUAL FIELD CONDITIONS. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE ENGINEER AND THE CONSTRUCTION MANAGER. THE CONTRACTOR SHALL OBTAIN. PAY FOR AND DELIVER ALL REQUIRED PERMITS, CERTIFICATES OF INSPECTION, INCLUDING UTILITY CONNECTION FEES, ETC., REQUIRED 13Y THE AUTHORITIES HAVING JURISDICTION AND SHALL DELIVER SUCH DOCUMENTS TO THE OWNER PRIOR TO FINAL ACCEPTANCE OF THE WORK. THE CONTRACTOR'S OPERATIONS SHALL BE CONFINED TO AREAS OF NEW CONSTRUCTION. ALL NECESSARY PROASIONS SHALL BE MADE TO PROTECT EXISTING IMPROVEMENTS. LANDSCAPING, PAVING. CURBS, GALVANIZED SURFACES. ETC. AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO SAME RESULTING FROM THE CONSTRUCTION WORK. ALL DISTURBED AND DAMAGED AREAS SHALL BE RESTORED TO THEIR ORIGINAL CONDITION OR BETTER UPON COMPLETION OF ALL WORK TO THE SATISFACTION OF THE CONSTRUCTION MANAGER. THE FOLLOWING CLEANUP TASKS SHALL BE PERFORMED AS FOLLOWS: (1) ON A DAILY BASIS, KEEP THE GENERAL AREA CLEAN AND HAZARD FREE. REMOVING ALL WASTE. DEBRIS AND TRASH FROM THE SITE AND DISPOSING OF SAME IN A LEGAL MANNER. (2) UPON COMPLETION. LEAVE THE PREMISES IN A CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST. OR SMUDGES OF ANY NATURE. ALL EQUIPMENT AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE RESPECTIVE MANUFACTURER'S RECOMMENDATIONS EXCEPT WHERE IT IS SPECIFICALLY INDICATED OTHERWISE IN THE CONTRACT DOCUMENTS OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS. ORDINANCES, RULES. REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY HAVING JURISDICTION OVER THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AS WELL AS LOCAL AND STATE CODES, ORDINANCES AND APPUCA13LE REGULATIONS. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AT ALL TIMES. USING THE BEST SK11 I q AND ATTENTION. HE SHALL BE SOLELY RESPONSIBLE FOR ALL OF THE CONSTRUCTION MEANS, METHODS, TECHNIQUES. SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK, INCLUDING CONTACT AND COORDINATION WITH THE CONSTRUCTION MANAGER AND WITH THE OWNER'S AUTHORIZED REPRESENTATIVE. WITHIN TEN (10) WORKING DAYS AFTER PROJECT COMPLETION, THE CONTRACTOR SHALL PROMDE A COMPLETE SET OF AS -BUILT DRAWINGS. SWEEP TEST. CYLINDER TESTS. LIEN RELEASES, AND OTHER cLosEourr DOCUMENTATION AS REQUIRED BY THE OWNER. ALL SYSTEMS SHALL BE COMPLETELY ASSEMBLED, TESTED, ADJUSTED AND DEMONSTRATED TO BE READY FOR OPERAT10N PRIOR TO THE OWNER'S ACCEPTANCE. GENERAL NOTES 1. THE APPROPRIATE UTILITY LOCAMNG SERVICES SHALL BE CONTACTED PRIOR TO THE START OF CONSTRUCTION IN ORDER TO VERIFY THE EXACT LOCATION OF ALL EXISTING UNDERGROUND UTILITIES. 2. THE INSTALLATION OF NEW UTILITIES SHALL BE COORDINATED WITH LOCAL AUTHORMES. 3. ALL ENISTING ACTIVE SEWER, WATER. GAS, ELECTRIC AND OTHER UTILITIES. WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES. WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SUCH UTILITIES SHALL BE RELOrATED AS DIRECTED BY THE CONSTRUCTION MANAGER. EXTREME CAUTION SHALL BE USED WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. 4. RUBBISH. STUMPS, DEBRIS. STICKS. STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 5. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES THAT INTERFERE WITH THE EXECUTION OF THE WORK SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS THAT WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF THE LANDLORD AND/OR LOCAL UTILITIES. 6. DISTURBANCE TO THE EXISTING SITE DURING'CONSTRUCTION SHALL BE MINIMIZED. 7. ANY AREAS OF THE CONSTRUCTION SITE DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER. EQUIPMENT OR DRIVEWAY. SHALL BE GRADED TO A UNIFORM SLOPE. SUCH GRADING SHALL CAUSE SURFACE WATER TO FLOW AWAY FROM ANY EQUIPMENT SHELTER AND TOWER AREAS AND THE SOIL SHALL BE STABILIZED TO PREVENT EROSION. EROSION CONTROL MEASURES,F REQUIRED DURING CONSTRUCTION. SHALL 13E IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL B. THE SUB -GRADE SHALL BE COMPACTED AND BROUGHT TO A UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 9. EACKFILL SHALL CONSIST OF CLEAN SAND FILL APPROVED FOR USE BY THE ENGINEER. NO UNAPPROVED MATERIAL WILL BE ALLOWED. CLEAN SAND FILL SHALL BE FREE OF ALL ROOTS. BOULDERS, OR OTHER DELETERIOUS MATERIAL 10. THE CONTRACTOR SHALL RESTORE ALL DISTURBED AREAS TO EQUAL TO OR BETTER CONDITION THAN ORIGINAL 11. SITE SIGNIAGE SHALL BE PROVIDED IN ACCORDANCE WITH THE TECHNICAL SPECIFICATIONS FOR SUCH SIGNAGE AS MAY BE CONTAINED IN THESE DRAWINGS. I SITE WORK NOTES 121 1. MATERIAL* A. ALL STRUCTURAL STEEL WORK SHALL CONFORM TO THE LATEST EDITION OF THE AJSC 'STEEL CONSTRUCTION MANUAL�. B. ALL STRUCTURAL STEEL WF BEAMS SHALL BE ASTM A992 AND "HOT DIPPED' GALVANIZED IN ACCORDANCE WITH ASTM Al2.3 AND ASTM A153 STANDARDS. C. ALL STRUCTURAL PLATES. ANGLES, AND CHANNELS SHALL BE ASTM A36 AND -HOT DIPPED- GALVANIZED IN ACCORDANCE WITH ASTM A123 AND ASTM A153 STANDARDS. D. ALL TS MEMBERS SHALL BE ASTM A500 GRADE B (FY=46ks-l). AND "HOT DIPPED' GALVANIZED IN ACCORDANCE WITH AsTm A123 AND ASTM A153 STANDARDS. E. ALL STRUCTURAL PIPE MEMBERS SHALL BE ASTM A500 GRADE B (FY=42ks!). AND "HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM A123 AND ASTM A153 STANDARDS. F. ALL NON-STRUCTURAL PIPE MEMBERS SHALL BE ASTM A53 GRADE B. AND "HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM A123 AND A.�TM A153 STANDARDS. 2. DESIGN. FABRICATION, AND CONSTRUCTION OF ALL CONNECTIONS SHALL CONFORM TO ASC STEEL CONSTRUCTION MANUAL 3. WELDING, A. ALL WELDS. WELDERS. AND WELD INSPECTIONS SHALL CONFORM TO THE REQUIREMENTS OF AWS D 1.1. LATEST REASION. B. ALL WELDS SHALL 13E MADE WITH E70XX LOW HYDROGEN ELECTRODES. C. ALL STEEL SHALL BE SPRAY GALVANIZED AFTER WELDING. 4. ALL BOLTS SHALL BE GALVANIZED %" DIAMETER. A325-N, UNLESS NOTED OTHERWISE AND TIGHTENED TO A "SNUG TIGHT" CONDITION AS DEFINED BY AISC. SECURE NUT WITH LOCKING WASHER. 5. ANCHOR BOLTS SHALL CONFORM TO ASTM A307, UNLESS NOTED OTHERVASE. 6. THE CONTRACTOR/STEEL FABRICATOR SHALL LOCATE ANY REINFORCEMENT IN THE STRUCTURAL MEMBERS IN SUCH A WINNER SO THAT THERE WILL NOT BE CONFLICT WITH THE REINFORCEMENT WHEN INSTALLING ANCHORS. THE ANCHORS SHALL BE INSTALLED PER THE MANUFACTURER'S INSTRUCTION. 7. THE CONTRACTOR/STEEL FABRICATOR SHALL CONFORM TO THE MINIMUM EDGE DISTANCE REQUIREMENTS IN ACCORDANCE 'A MANUAL OF STEEL CONSTRUCTION. 8. ALL STRUCTURAL STEEL SHALL BE FABRICATED TO FIT AT BOLTED CONNECTIONS WITHIN Xs INCH TOLERANCE. STRUCTURAL STEEL SHALL NOT BE FLAME CUT UNDER ANY CIRCUMSTANCES WFHOUT APPROVAL OF THE ENGINEER. 9. THE CONIPACTOR/STEEL FABRICATOR SHALL CAP OR SEAL ALL PIPES AS REQUIRED TO PREVENT RAINWATER INTRUSION. 10. THE CONTRACTOR/STEEL FABRICATOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW PRIOR TO ANY STEEL FABRICATION. AT THE CONTRACTOR'S OPTION. FIELD SPLICES MAY BE USED FOR ERECTION PURPOSES. IF FIELD SPLICES ARE USED, THE SHOP DRAWINGS SHALL INCLUDE ALL DETAILS FOR THE PROPOSED FIELD SPILICES. 11. AT THE CONTRACTOR'S OPTION, SHOP WELDS MAY BE USED INSTEAD OF FIELD WELDS. 12. SUBMIT ORIGINAL SHOP DRAWINGS. INCLUDING COMPLETE DETAILS. SCHEDULES OF FABRICATION AND ASSEMBLY. PROCEDURES. AND DIAGRAMS. INCLUDE DETAJLS OF CUTS. CONNECTIONS, CAMBER. HOLE, AND OTHER PERTINENT DATA. INDICATE WELDS BY STANDARD AVIS A2.1 AND A2.4 SYMBOLS. AND SHOW SIZE, LENGTH. AND TYPE OF WELD. PROVIDE SETTING DRAWINGS. TEMPLATES. AND DIRECTIONS FOR INSTALLATION OF ANCHOR BOLTS AND OTHER ANCHORAGES TO BE INSTALLED AS WORK OF OTHERS' SECTIONS. 1 STEEL NOTES 1 3� 'm DAM DESCRIPTION A 5/3/18 PRELIMINARY B 9/6/18 REVISED 0 9/11/18 FOR PERMIT APX PROJECT NO.: 18-0162122 _2RAWN By.. C. BELLO I. CHECKED BY. M. ABBEY THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OMER. rr IS PRODUCED SOLELY FOR USE By THE OWNER AND rrS AFFILIATES. REPRODUCTION OR USE OF THIS DRAMNO AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRTUEN PMMISSION OF THE OWNER. A a ENGINEERING GROUP �O UXUIDE DRNE. SURE 525 Ml�. FL 33U7 (95,1) 744-lMS CER`R9CITE OF AMORWON 319M at&t 9501 W SUNRISE WULWARD PlMtATION. M XIM % ER o 8 19/ ST A% - DATE F SIG R 9/11/18 RIVERPARK 1480 DYER ROAD PORT Sr WCIE. FIL 34952 GENERAL NOTES T2 EXISTING SPRINT CONCRErE EQUIPMENT PAD EXISTING COAX BRIDGE (TYP.) EXISTING AT&T CABLES —X—X—X—X—X—X—X—X—X— A/C I I A/C EXISTING EQUIPMENT SHELTER (US GOVERNMENT) EXISTING GRAVELED AREA EXISTING AT&T EQUIPMENT SHELTER A/C EXISTING ATC EQUIPMENT SHELTER -X-X-X-X-X-X EXISTING SPRINT EQUIPMENT SHELTER EXISIIING SPRINT EQUIPMENT CABINEr (TYP. OF 2) EXISTING SPRINT UTILITY H—FRAME )cx x- x- x F" EXISTING 12'* WIDE A/C ACCESS GATE EXISTING 200'± GUYED TOWER EXISTING VERIZON EXISTING 16':1: WIDE x WIRELESS UP GENERATOR ACCESS GATE EXISTING 6' HIGH CHAJN—UNK FENCE W/ 3—STRAND BARBED WIRE z EXISIIING UTUTY H—FRAME (TYP.) x x . X—X—X.—X—X—1 EXISTING 13'* WIDE ACCESS GATE EXISTING VERIZON WIRELESS UP TANK EXISTING VERIZON WIRELESS EQUIPMENT CONTRACTOR SHALL REMOVE EXISTING UNUSED COAX AS CABINET (TYP. OF 3) NEEDED TO CREATE SPACE FOR PROPOSED CABLES. 0 r v w COMPOUND PLAN 1 'REV DATE DESCRIPTION A 5/3/18 PRELIMINARY 8 9/6/18 REMSED 0 9/11/18 FOR PERMIT APX PROJECT NO.: 18-0163.22 DRAWN BY: C. BELLO CHECKED BY. M. ABBEY THIS DRAWING IS COPYRIGHTED AND IS� THE SOLE PROPERTY OF ME OWNER. IT IS PRODUCED SOLELY FOR USE�EIY THE OWNER AND ITS AFFILIATES. REEPRODUCTION OR USE OF THIS DRAVANG AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT 714E WRITTEN PERMISSION OF THE OWNER. a ENGIN BERING GROU P �O WESIDE O"� SUM 525 Ml�. F. W027 (954) 744-1�8 CIOTORCATE OF AMORIUATION 31948 6�i� aw ITON. R- W 2 7ER .......... E ry 85 9 F OR I'D N Al - DATE OF SIGNAM 9 11/18 RIVERPARK 1410 DYER ROAD PONT ST LUCIE FL 34952 MEET N)IME COMPOUND PLAN SHEET NUMBER c 1 0 r 09M OF EXISTING AT&T ANTENNAS RAD R OF EXISTING SPRINT/NE)crEL ANTENNAS EL 172TY VILE 617 OF EXISTING VERIZON WIRELESS ANTENNAS � r dZYR OF EXISTING SPRINT ANTENNAS RA:D C OF EXISTING US GOVERNMENT ANTENNAS � r IvOl OF EXISTING US GOVERNMENT ANTENNAS 1. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL ADVISE MASTEC CONSTRUCTION MANAGER OF THE ESTIMATED SITE DOWN TIME. 2. THIS DRAWING IS INTENDED TO DEPICT THE GENERAL LOCATION AND HEIGHT OF THE PROPOSED ANTENNAS ON THE EXISTING TOWER. CONSTRUCTION SHALL NOT PROCEED UNTIL A STRUCTURAL ANALYSIS REPORT HAS BEEN COMPLETED BY A PROFESSIONAL ENGINEER REGISTERED IN THIS STATE, CONCLUDING THAT THE EXISTING TOWER IS STRUCTURALLY ADEQUATE TO RESIST THE EXISTING AND PROPOSED LOADS. ELEVATION rall r gga 03 p NOTE, REFER TO CURRENT RFDS FOR EQUIPMENT MODELS. EXISTING AT&T RAYCAP FIBER DISTRIBUTION UNIT (TYP. OF 2) , EXISTING AT&T RRLIS-12 TO BE REMOVED CM. OF 3) EXISTING AT&T ANTENNA (TYP. OF 9) ELEV. EXISTING AT&T RRUS-11 IqO'± (TYP. OF 3) SE—CTO%o A7. FF 6 EXISTING AT&T krrENNA MOUNT (TYP. OF 3) EXISTING AT&T RRUS-32 (TYP. OF 3) I EXISTING ANTENNA PLAN NTsl 2 1 1( 51 NM REFER TO CURRENT RFDS FOR EQUIPMENT MODELS. 1 PROPOSED ANTENNA PLAN EXISTING AT&T RAYCAP FIBER DISTRIBUTION UNIT (TYP. OF 2) PROPOSED AT&T RRLIS-4426 BOB (TYP. OF 3) PROPOSED AT*T RRLIS-4415 B25 (TYP. OF 3) EXISTING AT&T ANTENNA (TYP. OF 9) EnLEV. EXISTING AT&T RRUS-11 IqO':i: (TYP. OF 3) �T" Z SAZ FF OF EXISTING AT&T ANTENNA MOUNT (TYP. OF 3) 'vk -32 EXISTING AT&T RRUS 0 (TYP. OF 3) 'REN DATE DESCRIPIR ON 5/3/18 PRELIMINARY B 91 REVISED 0 9/11/18 FOR PERMIT I APX PROIEIT NO.: 18-0163.22 7 _ RA;W a. c. saLo mEcKm By. ME ABBEY 7 THIS DRAWING IS COPYRGHTED AND IS THE SO� PROPUM OF THE OWNEF- IT IS PRODUCED SOLELY FOR USE By THE OWNER AND ITS AFFILIATES. REPMOUCTON OR USE OF THIS DRAWING A4D/OR THE INFORMATION CONTAINED IN IT IS FOREIDDE31 WITHOUT THE WRITTEN PERMISSION OF THE OWNM A a ENGINEERING GROU? �00 IMESIDE DRJM SUITE 525 MIRAMAR. R 33027 (954) 744-1538 CEMCAM OF AUTHORIWON 31948 &�, at&t 8601 W SUNRISE BOUUWMD P�AMON. R 33322 ER N 85 9 cz STA 0 R I'D ...... *' % p NAk- - .%% DATE OF SIGHATURL- 9/1 RIVERPARK T DYM ROAD PORT ST LUCIE. FL 34952 SHEET NAME ELEVATION AND ANTENNA PLANS SHEET NUMEMER N T J S C2 L PROPOSED AT&T APPROVED MOUNTING BRACIKEr CrYP. OF 2 PER RRU) PROPOSED AT&T RRU CFYP.) EXISTING ANTENNA MOUNTING PIPE NOTES' 1. UNIT SHALL BE MOUNTED AS PER MANUFACTURER'S RECOMMENDATIONS. 2. CONTRACTOR SHALL TIGHTEN ALL BOLTS TO A 'SNUG FIGHT" CONDITION AS DEFINED BY AJSC. (NOT USED) 11 (NOT USED) 12 RRU MOUNTING DETAIL INITS 13 ((NOT USED) (NOT USED) (NOT USED) 6 rREV DATE DESCRIPMON A 5/3/18 PRELIMINARY B 9/s/18 REVISED 0 9/11/18 FOR PERMIT APX PROUECT NO.: 18-0153.M DRAWN BY. C. BELLO CHECKED BY. M. ABBEY _4 THIS DRAWING IS COPYRIGKTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED WLELY FOR USE BY ME OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF TIIIS DRAVANG AND/011 THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. - A (3 A ENGINEERING GROUP �00 L&KESIDE DRIVE. SUITE 525 MIRA�. F1 33027 (954) 744-1538 CENRnwe OF AMORI�=N 31948 8601 W SUNRISE BOULEVARD PLANTATION. 9- 33322 %%�­\s4till 0z 852 Cc s 0 F % % NAl_ Q�MGMATUR�r- 9/11/10 RIVERPARK 1480 DYER ROAD PORT ST LUCIE. FL 34952 DETAILS C3 N1.1 )l h X @ H z'5 LEGEND, D A SECTOR GROUND BAR (TYP) B COLLECTOR GROUND BAR C ANTENNA D SINGLE PAR FIBER & DC POWER E 1/2- JUMPER CA13LE CrYP) F MOUNT PIPE G DC POWER & FIBER TO RAYCAP UNIT H REMOTE RA610 UNIT (RRU) (IF APPLICABLE) I DC6 RAYrAP SURGE SUPPRESSOR (IF APPLICABLE) J #2 AWG SOLID BARE OR JACKETED TINNED COPPER (TYP.) 2 NOTES, 1. CONTRACTOR SHALL REFER TO AT&T GROUNDING AND BONDING PRACTICE TP-76416. ALL EXOTHERMIC CADWELDS SHALL BE PERFORMED BY CERTIFIED TECHNICIAN. 2. PROVIDE WEATHER PROOFING AND GROUNDING KIT TO BOND OC POWER CABLE SHIELD TO EXTERNAL HATCH PLATE GROUND BAR. 3. PROVIDE GROUND CONNECTION FOR DO POWER CABLE SHIELD TO "P" SECTION OF CRGE WITHIN SHELTER. 4. CONTRACTOR SHALL USE THEFT RESISTANT GROUND WIRES AND BARS WHEN FEASIBLE. 5. CONTRACTOR SHALL MANTAN A 12' MINIMUM GROUND WIRE BEND RADII. 6. GROUND LUGS, HEATSHRINK AND CLAMPS DEVICES SHALL COMPLY WITH AT&T GROUNDING AND BONDING PRACTICE TP-76416. tXIh I INU JKUUNU BAR #2 AWG SOUD BARE OR JACKETED TINNED COPPER (TYP-) %" SS WASHER %")ry4' SS BOLT SS WASHER SS LOCK WASHER SS NU­r NOTES, 1. UTILJZE EXISTING AT&T GROUND BARS AND GROUNDING. 2. ADD GROUND BARS IF THERE ARE INSUFFICIENT LUG POSMONS. 3. REFERENCE AT&T BONDING & GROUNDING PRACTICE TP76416. rREV DATE DESCRipnON A 5/3/18 PRELIMINARY B 9/s/is REVISED a 9/11/18 FOR PMIAiT APX PROJECT NO.: le-Olum DRAWN BY: C. BELLO ABBEY THIS DRAWING IS COPYPJGKrED AND IS THE SOLE PROPERTY OF THE OWNER. rr IS PRODUCED SOLELY FOR USE EY ME OWNER AND IS AFFILIATES. IEPRODUCIION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN A a ENGINEERING GROUP MOO MMDE )�. SUITE 525 MIRANAR. R 33027 (954) 744-1538 CERnFICATE OF AUTHOMMON 31948 TYPICAL GROUND BAR CONNECTION DETAIL NTsj 2 �? at&t 1. RECORD DRAWINGS: MAINTAN A RECORD OF ALL CHANGES, SUBSTITUTIONS BETWEEN WORK AS 8501 W SUNRISE BOULINARD PUMMON, FL M322 SPECIFIED AND INSTALLED. RECORD CHANGES ON A CLEAN SET OF CONTRACT DOCUMENTS WHICH SHALL BE TURNED OVER TO THE CONSTRUCTION MANAGER UPON COMPLETION OF THE PROJECT. % \s7_ER 0/. 2. GUARANTEEtVARRANTY. GUARANTEE INSTALLAT10N TO BE FREE OF DEFECTS, SHORTS, GROUNDS. ETC.. FOR A PERIOD OF ONE YEAR. FURNISH WARRANTY SO THE DEFECTIVE MATERIAL. AND/OR <'v .......... 4 >' ee I 41: .-'\rElVS-_ WORKMANSHIP WILL BE REPAJRED/REPLACED IMMEDIATELY UPON NOTIFICATION AT NO COST TO :% THE 0 - WNER FOR PERIOD OF WARRANTY. N 852 3. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. cj: 4. ELECTRICAL METALUTC TUBING (EWr) OR RIGID NONMETALLIC CONDUIT (I.E.. RIGID PVC ST SCHEDULE 40, OR RIGID PVC SCHEDULE 80 FOR LOCATIONS SUBJECT TO PHYSICAL DAMAGE) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. 4 5. UQUID-11GHT FLEXIBLE METALLIC CONDUIT (UQUID—TTE FLEX) SHALL BE USED INDOORS AND C OUTDOORS. WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. AIL- B. WIREWAYS SHALL BE EPDXY —COATED (GRAY) AND INCLUDE A HINGED COVER. DESIGNED TO DATE OF SIGNATU 9/11/15 SWING OPEN DOWNWARD: SHALL BE PANDUff TYPE E (OR EQUAL); AND RATED NEMA 1 (OR BETTER) INDOORS. OR NEMA 3R (OR BETTER) OUTDOORS. 7. EQUIPMENT CABINETS, TERMINAL BOXES. JUNCTION BOXES, AND PULL BOXES SHALL BE GALVANIZED OR EPDXY —COATED SHEET STEEL, SHALL MEET OR EXCEED UL 50, AND RATED RIVERPARK NEMA 1 (OR BETTER) INDOORS. OR NEMA 3R (OR BETTER) OUTDOORS. B. METAL RECEPTACLE. SWITCH. AND DEVICE BOXES SHALL BE GALVANIZED. EPDXY —COATED, OR NON —CORRODING: SHALL MEET OR EXCEED UL 514A AND NEMA OS 1; AND RATED NIEMA 1 (OR BETTER) INDOORS. OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. 14W DYER ROAD PORT ST LUCIE. FL 34952 9. NONMETALLIC RECEPTACLE, SWITCH. AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2; SHEET NAME AND RATED NFMA 1 (OR BETTER) INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. 10. CONTRACTOR SHALL REFER TO AT&T GROUNDING AND BONDING PRACTICE TP-76416. DETAILS ANTENNA GROUNDING SCHEMATIC (TYP.) ml 11 GROUNDING NOTES 1,31 [ C4 DC / FIBER DEMARCATION BOX RAYCAP DC FIBER DEMARCATION BOX CA13LES MOUNTING HEIGHT MODEL �UANTIT�Y MODEL TR/P�ur !LENGrH PER LINE ±lgo,—O" DC6-48-60-18-8F 2 ROSENBERGER (18) PAIR FIBER TRUNK L& 13/8-1 2 I (E) ONDUCTOR SHIELDED DC CABLEJ 3/4-1 4 (E) ANTENNA AND COAX SCHEDULE ANTENNA CABLES RRU A2 TMA DIPLEXER m SECTOR AZIMUTH RAD CF R ANTENNA MAKE ANTENNA MODEL ANTENNA (OTY) MECH DOWNTILT ELECT DOWNTILT CABLE MODEL SIZE OF CABLE LENGTH LINE COLOR CODE MODEL OTY. QTY. MODEL QTY. MODEL TOWER OUANITTY GROUND OUANTITY Q ALPHA (Al) 345' lg(),—O- ANDREW SBNHH—lD859 1 ROSENBERGER FIBER JUMPER (DC6 TO RRU 1B. 1 —PER 15' 1 RED RRUS-12 (G) 1 — — — — 2 ROSENBERGER SINGLE PAIR DC CABLES (DC6 TO RRU 7 16" 1 RRUS-32 1 — — — — — 1/2- COAX JUMPER (RRU TO ANTENNA) 1 2 b — — — — 1-5/8" COAX 1-5/8" 2 ALPHA (A2) ALPHA (A3) 345- lgo,—O" ANDREW SBNHH—lD85B ROSENBERGER FIBER JUMPER (DC6 TO RRU) 3/8" 15' 3 RED RRUS-11 1 — ROSENBERGER SINGLE PAIR DC CABLES (DC6 TO RRU) 7/16" 2 §0: RRUS-4415 825 1 — 1/2- COAX JUMPER (RRU TO ANTENNA) 1/2' 1 5 1 — — ALPHA (A4) 345' 190'-0" ANDREW SBNHH—lD85B ROSENBERGER FIBER JUMPER (DC6 TO RRU) 3/8- 2 15, 4 RED RRUS—B14 4478 (G) 1 — 2 ROSENBERGER SINGLE PAIR DC CABLES (DC6 TO RRU) 7/16- 1 15, RRUS-4426 B66 1 — — 1/2- COAX JUMPER (RRU TO ANTENNA) 1/2- 6 IO'_ — — 1 5/8- COAX 1-5/s" 2 (E) — — — BETA (Bl) 85, 190'-0" ANDREW SBNHH—IDBSB I ROSENBERGER FIBER JUMPER (DC6 TO RRU) 3/8'. 1 isr 1 BLUE RRUS-12 (G) 1 — 2 ROSENBERGER SINGLE PAIR DC CABLES (DC6 TO RRU) 7/16- 1 15' RRUS-32 1 — — - 1/2- COAX JUMPER (RRU TO ANTENNA) 1/2" 6 10, 1-5/8" COAX 1-5/8- 2 E) BETA (B2) BETA (83) 85, 190--o- ANDREW SBNHH—lD85B ROSENBERGER FIBER JUMPER (DC6 TO RRU) 3/8" 3 15' 3 BLUE RRUS-11 I — ROSENBERGER SINGLE PAIR DC CABLES (DC6 TO RRU) 7/16- 2 15' RRUS-4415 B25 1 — 1/2- COAX JUMPER (RRU TO ANTENNA) 112" 6 10' — — BETA (B4) 85' 190--o- ANDREW SBNHH—lDB58 ROSENBERGER FIBER JUMPER (DC6 TO RRU) 318- 2 15, 4 BLUE RRUS—EI14 4478 (G) 1 — 2 ROSENBERGER SINGLE PAIR DC CABLES (DCS TO - RRU) 7/16" 1 15, RRUS-4426 B66 1 — — 1/2" COAX JUMPER (RRU TO ANTENNA) 1/2- 6 lO'_ — — 1-5/8" COAX 1-5/8- 2 (E) — — — GAMMA (01) 240' go,—o- ANDREW SBNHH—lDS59 ROSENBERGER FIBER JUMPER (DC6 TO RRU) 318- 1 1 1 15' 1 GREEN RRUS-12 (G) 1 — 2 ROSENBERGER SINGLE PAIR DC CABLES (DC6 TO RRU) 7/16-1 1 1 1§ RRUS-32 I — — 1/2- COAX JUMPER (RRU TO ANTENNA) 1/2 1 5 1 0; 1-5/8" COAX 2 (E) GAMMA (G2) —1-5/8- GAMMA (G3) 240' 1 go,—o- ANDREW SBNHH—lD859 ROSENBERGER FIBER JUMPER (DC6 TO RRU) 3/8.. 3 15' 3 GREEN RRUS-11 I I — I — ROSENBERGER SINGLE PAIR DC CABLES (OC6 TO RRU) 7/16- 2 15, RRUS-4415 B25 1 — — 1/2" COAX JUMPER (RRU TO ANTENNA) 1/2- 6 __To� — — — GAMMA (G4) 240' go,—o- ANDREW SBNHH—lD8513 ROSENBERGER FIBER JUMPER (DC6 TO RRU) 3/8" 2 15' 4 GREEN RRUS—B14 4478 (0) 1 — — 2 ROSENBERGER SINGLE PAIR DC CABLES (DC6 TO RRU) 7/16"1 1 RRUS-4426 B66 1 — — — 1/2- COAX JUM ER (RRU TO ANTENNA) 1/2 1 6 O�: 1 — — — 1-5/8" COAX 1-5/8"1 2 1 DELTA (Dl) DELTA (D2) DELTA (D3) DELTA (D4) — TOTAL EXISnNG 9 TOTAL REMOVED 0 OTAL REPLACED 0 T OVERALL TOTAL 9 TOTAL 12 (E) TOTAL 18 0 TOTAL 0 TOTAL 1 0 1 12 1 0 FIBER 1-8 270' (E) = EXISTING (G) = GROUND P—OWER 12 180, JUMPER 54 540' _Wlf" CABLES 3 360' — �ANTENNA AND COAX SCHEDULE 'REV DATE DESCRIPTION A 5/3/18 PREUMINMY 8 9/6/18 REVISED a 9/11/10 FOR PERMIT APX PROJECT �O.: 1 !--Olw.H DRAVIN BY. 1. OE1113 L CHECKED BY. M. ABBEY MSL Counties 3 - Hex port Antennas ANTENNA POSMON #11 ANTENNA P(3SMCN#3 NOTES- 1. CONTRACTOR SHALL USE ERICSSON PROVIDED DC POWER CABLE CONNECTOR, 2. CONTRACTOR SHALL REMOVE EXISTING UNUSED COAX AS NEEDED TO CREATE SPACE FOR PROPOSED CABLES. ANTENNAPOSMON94 ) 1 7 20A 25A -f '�- - — — -& — — ( F 700 LTE 25A -E3- — — — 30A - — — — — — — — -- --- KEYNOTE LEGEND- 1 . -48V DC POWER PLANT. 2. (1) RACK MOUNTED RAYCAP OC SURGE PROTECTOR (DC6-48-60-RM). 3. RAYCAP FIBER AND DC DISTRIBUTION UNT (DC6-48-60-16-8F). 4. #8 AWG CONDUCTORS. 5. PROVIDE (2) 6-CONDUCTOR #8 AING BUNDLES FOR DC POWER FROM RACK MOUNTED RAYCAP SURGE PROTECTION UNIT TO THE RAYCAP FIBER AND DISTRIBUTION UNIT ON TOWER. 6. PROPOSED FIBER AND DC CABLE ROUTED TO PROPOSED RRH UNITS. 7. PROVIDE 20A CIRCUIT BREAKER FOR WCS RRH UNITS. 'REV DATE DESCRIPTION A 5/3/18 PREUMINARY 8 9/6/18 REIASED 0 9/11/18 FOR PERMIT APX PROJ DRAWN BY. C. BELLO CH KIM UY. M. ABBEY THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. Fr IS PRODUCED SOLELY MR USE BY THE OMER AND ITS AFFILIAIES. REPRODUCTION OR USE OF THIS DRAWNG ANO(OFICTHE INFORMATION CONTAINED IN IT S RSIDDEN WTTHOLT THE WRnTEN PERMISSION OF �E OWNER. a ENGINEERING GROUP �O LWESIDE DRWF, SUITE 525 Ml�. F. 33027 (954) 744-1538 CERIIFI�X OF AMHORRAMON 3194a ,Walm SUMSE BOU�MD P�AMN, FL W322 ER % IV 8521 ST14��F ..4 %% A% - DATE OF SIGNATUR g/11/18 RIVERPARK 1480 DYER ROAD PORT ST LUCIF FL 34952 DC ELECTRICAL DETAILS MEN RISER DIAGRAM (TYP. PER SECTOR) 111 DC RISER DIAGRAM 12 1 [ El