IA
Wood
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
5
1B
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5-9
1C
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
10-11
1D
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
12
1E
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
12-14
1F
Wood
New, Reroof (Tear -Off) or Recover
D
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
15-17
1G
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover
18-21
111
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover
21-25
11
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
26
2A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
27-29
2B
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
30-34
2C
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
35-37
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Banded Roof Cover
38-46
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
46
4A
Lightweight concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
47-49
4B
Lightweight concrete
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
s0
4C
Lightweight concrete
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
51-53
5A
Cementitious wood fiber
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Banded Roof Cover
54
SB
Cementitious wood fiber
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
55
5C
Cementitious wood fiber
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
56
SD
Cementitious wood fiber
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
56
5E
Cementitious wood fiber
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
56
6A
Existing gypsum
Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
57-59
6B
Existing gypsum
Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
59
6C
Existing gypsum
Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
60
6D
Existing gypsum
Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
60
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
61-65
7B
Various
Recover
F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
65
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
➢Wood: Minimum 0.75-inch penetration.
➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions.
NEMO ETC, LLC Evaluation Report P9290.02.08-1121 for FL1654-1123
Certificate of Authorization H32455 0 EDITION (2017) FBC NON-HVH7 EVALUATION Revision 21: 10/08/2018
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 1 of 65
OONEMOJetc.
3. Unless otherwise noted, insulation maybe anyone layer or combination of polyisocyanurate,polystyrene, wood fiberboard, perlite,gypsum-based roof board or mineral -wool roof board that meets the CIA requirements
of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet
fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural
members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval
documentation.
S. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturers published instructions.
➢ Hot asphalt (HA):
Full coverage at 25-30lbs/square.
➢ Dow INSTA STIK Quik Set Insulation Adhesive (D-15):
Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.
D Millennium One Step Foamable Adhesive (M-OSFA):
Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
➢ Millennium PG-1 Pump Grade Adhesive (M-PGI):
Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
➢ OMG OlyBond 500 (OB500):
Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green maybe used where OlyBond 5OO is referenced.
➢ OlyBond Classic (OB Classic):
Full coverage at 1 gal/square. '
➢ ICP Adhesive & Sealants Polyset CR-20:
Continuous 2.5-3.5-inch wide ribbons,12-inch o.c.
➢ Note: When multiple loyers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, boardjoints shall be staggered.
➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
7. Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations maybe substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to 'increase'
the MOP listings in the tables; rather if MDP listing below meets or exceeds that listed far a particular system in the tables, then the
thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table:
➢ Millennium One Step Foamable Adhesive(M-OSFA):
MDP -157.5 psf
(Min. 0.5-inch thick)
➢ Millennium PG-1 Pump Grade Adhesive (M-PG3):
MOP -157.5 psf
(Min. 0.5-inch thick)
➢ OMG OlyBond 500 (OB500):
MDP -45.0 psf
(Min. 0.5-inch thick Multi -Max FA-3)
➢ OMG OlyBond 500 (OB500):
MDP -187.5 psf
(Min. 0.5-inch thick ISO 95+ GQ
➢ OMG OlyBond 500 (OB500):
MDP -315.0 psf
(Min. 0.5-inch thick ENRGY 3)
➢ OMG OlyBond 500 (OB500):
MDP .487.5 psf
(Min. 0.5-inch thick ACFoam II)
➢ ICP Adhesives & Sealants Polyset CR-20:
MDP -117.5 psf
(Min. 1.0-inch thick)
8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss Prevention
Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk" carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data
Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum
requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TA5105.
12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and band performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with
AN51/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application.
NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for FL3654-1123
Certificate of Authorization #32455 6n' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 10/08/2018
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 2 of 65
MEMO I etc.
14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat
thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For "pre-existent' LWC references, listings were established through testing over lightweight concrete cast
using only foaming agent (ASTM C896), water and Portland cement (ASTM C350), with no proprietary additives, in accordance with procedures adopted by Miami -Dade BCCO (FBC CER3592). Unless otherwise noted,
use of these listings in new construction or re -roof (tear -off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction.
15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
REFERENCE
LAYER
MATERIAL APPLICATION
BP -AA
Base Ply
One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type II
Ho[ Asphalt a[ 20-40
(Base and Ply sheets,
Ply
One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI
Ibs/square
Asphalt -Applied)
Note:
Asphalt -applied sheets or insulation shall not be applied to poly -film surfaced membranes.
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 Type II, Polyglass HT Base 650
PG350 at 1.5-2.0
SBS-CA1
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex 56 Type II, Elastoflex S6 G, Elastoflex 56 G FR, Elastoshield TS-G, Elastoshield
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex 56 Type II
Polyplus 35 at 1.5-2.0
SBS-CA2
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply or Ply
One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex 56, Elastoflex
SBS-AA
56 Type II, Polyglass HT Base 650
Hot Asphalt at 20-40
(585, Asphalt -Applied)
Cap Ply
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex 56 Type II, Elastoflex 56 G, Elastoflex 56 G FR, Elastoshield TS-G,
Ibs/square
Elastoshield TS-G FR, Polyfresko G 565 (sand -backed), Polyfresko G 5B5 FR (sand -backed)
Nate:
Asphalt -applied sheets or insulation shall not be applied to poly -film surfaced membranes.
Base Ply or Ply
or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex 56, Elastoflex S6 Type II, Polyglass HT Base
SBS-TA
6One 50
(SBS, Torch -Applied)
Cap Ply
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex 56 G, Elastoflex 56 G FR, Elastoshield TS-
Torch -Applied
G, Elastoshield TS-G FR, Polyfresko G SBS (poly-flm backed), Polyfresko G SBS FR (poly -film backed)
Base Ply
One or more plies Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex 5A V Plus FR
SBS-SA
Cap Ply
Elastoflex SA P, Elastoflex SA P FR, Polyreflect
(SBS, Self -Adhering)
Note:
Unless otherwise noted, permissible membrane substrates)or5B5-SA are limited to the5B5-5A Base Ply options herein,
Self -Adhering
Elastobase (poly/sand) or Elastobase (poly/poly).
APP-CA1
Cap Ply
Polyflex G FR
PG350 at 1.5-2.0
gal/square
APP-TA
Base Ply or Ply
One or more plies Polyglass APP Base, Polyflex, Polybond
(APP, Torch -Applied)
Cap Ply
Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR
Torch -Applied
Cap Ply
Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polykool
APP SA
(APP, Self -Adhering)
Note:
Unless otherwise noted, permissible membrane substratesforAPP-SA are limited tothe5B5-SA Base Ply options herein,
Self -Adhering
Elastobase (poly/sand) or Elastobase (poly/poly).
NEMO ETC, LLC Evaluation Report P9290.02.08-1121 for FL1654-R23
Certificate of Authorization #32455 6'" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 10/08/2018
Prepared by: Robert Niernmen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 3 of 65
16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations.
applies:
NNEMOjetc.
The lesser of the MDP listings below vs. those in Table 3A
OPTION
#
PRIMER
VAPOR BARRIER
INSULATION ADHESIVE
MDP (PSF)
TYPE
ATTACH
VB-1.
PG100
Elastoflex SA V Plus
Self -Adhering
Inta-Stik or CR-20, 12-inch o.c.
-60.0
VB-2.
PG100
Polyglass APP Base
Torch -applied
Inta-Stik or CR-20, 12-inch o.c.
-75.0
VB-3.
PG100
Elastoflex SA P
Self -Adhering
Insta-Stik, 12-inch o.c.
-75.0
VB-4.
PG100
Elastoflex SAP
Self -Adhering
Millennium One Step Foamable Adhesive,12-inch o.c.
-157.5
VB-5.
PG300
Elastoflex SA P
Self -Adhering
I CR-20, 12-inch o.c.
-270.0
VB-6.
PG100
Elastoflex SA V Base, Elastoflex SA V FR Base,
Elastoflex SA V Plus, Elastoflex SA V Plus FIR
Self -Adhering
Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade
I Adhesive, OlyBond 500 or CR-20, 12-inch o.c.
-290.0
17. The following surfacing may be applied to the Cap Ply without adverse effect on the system wind load performance. Refer to current Florida Product Approval for approved Polyglass and KM Coatings roof coatings for
application limitations and a Roofing Materials Directory for fire ratings associated with coating -usage.
Option If
Surfacing
Florida. Product Approval
SURF-1.
PG300 Fibered Roof Coating
FL10291
SURF-2.
PG600 Non-Fibered Aluminum Roof Coating
FL10291
SURF-3.
PG65D Fibered Aluminum Roof Coating
FL10291
SURF-4.
PG700 High Quality Elastomeric Roof Coating
FL10291
SURF-5.
PG700QS (Quick Set) High Quality Elastomeric Roof Coating
FL10291
SURF-6.
PG800 Asphalt Emulsion Roof Coating
FL10291
SURF-7.
Polyplus 60 Premium Non-Fibered Aluminum Roof Coating
FL10291
SURF-8.
Polyplus 65 Premium Fibered Aluminum Roof Coating
FL10291
SURF-9.
Polybrite 70 Premium Grade Elastomeric Roof Coating
FL10291
SURF-10.
Polybrite 70QS(Quick Set) Premium Grade Elastomeric Roof Coating
FL10291
SURF-11.
Polybrite 71 HS
FL10291
SURF-12.
Polybrite 90 High Solids Silicone Roof Coating
FL10291
SURF-13.
Polybrite 95 Silicone Roof Coating
FL10291
SURF-14.
KM Acryl 15
FL27409
SURF-15.
KM Acryl 15 QS
FL27409
SURF-16.
KM Acryl 25
FL27409
SURF-17.
KM Acryl 25 QS
FL27409
SURF-18.
KM Acryl 40 HIS
FL27409
SURF-19.
KM Acryl 85
FL27409
SURF-20.
KM PS#250
FL27409
SURF-21.
KM PS#220
FL27409
18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
NEMO ETC, LLC Evaluation Report P9290.02.08-1121 for FL3654-1123
Certificate of Authorization #32455 6t" EDITION (2017) FBC NON-HVH2 EVALUATION Revision 21: 10/08/2018
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 4 of 65
*NEMO I etc.
.os r 4 . .R •.a . .
.:... •..
System
Roof Cover (Note 15)
Deck (Note 1)
MDP (psf)
Primer
Joint Treatment
'Base Ply
Ply
Cap Ply
Min. 15/32-
(Optional)SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
CNo
W 170
Finch plywood
None
None
SBS-SA
TA, APP-TA
TA, APP-TA
-90.0
Min. 15/32-
W-171
inch plywood
(Optional) PG300
None
Polyflex SA Base
(Optional)APP-TA
APP-TA
-90.0
Min, 15/32-
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
W 172
inch plywood
pG100
None
SBS-SA
TA, APP-TA
TA, APP-TA
Min. 15/32-
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
Elastoflex SA V Base or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
W-173
inch plywood
(Optional) PG100
place to create continuous bond.
Elastoflex SA V FR Base
TA, APP-TA
TA, APP-TA
97.5
Min. 15/32-
SBS-
SBS-SA, -$A, SBS-
W 174
inch plywood
POLYBRITE 745
None
SBS-SA-105.0
TA, APP-TA5B5-SA,
TA
Min. 15/32-
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
Elastoflex SA V Pius or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
W-175
inch wood p y
(Optional) PG100
place to create continuous hood.
Elastoflex SA V Plus FR
TA, APP-TA
TA, APP-TA
-135.0
Min. 15/32-
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
W-176
inch plywood
(Optional) PG100
place to create continuous bond.
Polyflex SA Base
(Optional)APP-TA
APP-TA
-135.0
NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for FL1654-R23
Certificate of Authorization #32455 6'a EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 10/08/2018
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 26 of 65