HomeMy WebLinkAboutMISC LETTERIf � � T l Avl'bls�
Architectonic Inc - RF�Er�Eo
/9
Permit
S tin9 D
eJanuary 21, 2019 r'Lucie �PBMhmeet
Saint Lucie County Building Department
Attn: Roof Permit Plan Review
2300 Virginia Avenue
Ft. Pierce, FL 34982
Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure
located at 3455 N. US Hwy 1, Saint Lucie County, Florida
Manufacturer:
Profiles:
Code:
Wind Speed:
Exposure:
Risk Category:
Mean Roof Height:
Pitch:
Required Design Pressure:
Maximum Uplift Pressure:
Base:
Ply Sheet:
Cap:
Roof Decking:
Polyglass USA
Modified Bitumen Roof System, FL #1654.1, System W-170
FBC 2017
160 MPH; Ultimate Design Wind Speeds
C
II
30' Maximum
X /12
Zonel: -31.46 Zone 2: -49.61 Zone3: -68.97
-90 psf, System # W-170
SBS-SA
(Optional) SBS-SA, SBS-TA, APP-TA
SBS-SA, APP-SA, SBS-TA, APP-TA
Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank @ 6"
O.C. thru out Zone 1, 4" O.C. perimeter, and 6: O.C. field zone 2, and 4"
O.C. thru out Zone 3 or 1 x 4 planks W/2 nails per plank per member
The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code,
and the Manufacturer's recommendations.
CONCEALED FASTENERS OR AITACHMEM
ARE THE RESpONSISILIf y OF THE
CONTRACTOROFRECORD
806 Delaware Avenue Tel: 772 460 7751
Fort Pierce, Florida 34950 Fax: 7724604244
ST. LUCIE CP
BUILDING DI
REVIE
FOR COW L
REVIEWED Y
DATE I Poo
PLANS AMDiPERMIT
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
THESE PLANS AND a PROPOSED WORT(
ARE SUMCT TO ANY C=SCV0pIR
REQUIRED By FIELD INSPECTORS THAT
NAM NECE584RY IN ORDER TO
COiAFLYWITH ALLAPPLIC4MCOMS,
FL Reg #AA26003348
R..
a � t�i. t �• ^�