Loading...
HomeMy WebLinkAboutMISC LETTERArchitectonic Inc St. Lucie County Building Department Planning & Development Services RECEIVED Building & Code Regulation Division SCANNED 2300 Virginia Avenue By JAN 14 1019 Ft. Pierce, FL 34982 St. Lucie County Permitting De ountyent January 10, 2019 St, Luclo C RE: 6144 S US Hwy 1, Fort Pierce, FL 34982 To Whom It May Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed Store Front Doors are incompliance with the 2017 Florida Building Code,165 mph wind zone, exposure "C", risk category II. Exposure "C" Multiplier for 15' mean roof height is 1.21 Wind Zone 4 29.82 x 1.21= 38.08 Wind Zone 5 36.21 x 1.21 = 43.81 Required Design Pressures:' +/-43.81 ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIANCE REVIEWED BY DATE PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE Product: Oldcastle Building Envelope, Series MSC-375 and WSD-500 ALUM. FRONT DOORS, FL# 17693.1 Product Pressures: +/-60 Product: Oldcastle Building Envelope, Series FG-5000 FLUSHED GLAZED ALUM. WINDOW, FL# 17688.3 Product Pressures: +/-90 TES€ E PLOPS At;D I PR©P06ca WORK ARE Sl1S.,ECTTOANY Ct1, marioN3 REQUIRED V FIELD NECEiIPFE RS 7its1T fb.'ly sm SSARY d,ORDER �0 COP9FLYt''11 ALL.nopL1 Lr CbDES,/R CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBUTY OF THE CONTRACTOR OF RECORD C 0 H fie: } of 806 Delaware Avenue Fort Pierce, Florida 34950 Tel: 772 460 7751 Fax: 772 460 4244 www.architectonicinc.com FL Reg #AA26003348 1 of 1