HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONS���eForce St L cie NED
HURRICANE SHUTTERS, INC. County
PANELS • ACCORDIONS • BAHAMAS
Information
Owner: Kings Plaza
Address: 7630 South Federal Highway
Port Saint Lucie, F134952
Information
Wind Zone:
170 MPH.
Exposure Category:
B
Minimum Building Dimension:
5 ft.
Mean Roof Height:
12 ft.
Risk Category:
II
Design Pressure Calculations
Opening
Number
Location
Zone
Device
Width (m)
Device
Height (in)
Device
Elevation (ft)
Max Positive
Pressure (psf)
Max Negative
Pressure (psf)
1
End
68
67
7
26.4
-33.8
2
Int
157
67
7
24.9
-27.3
3
Int
172
67
7
24.7
-27.1
4
Int
108
67
7
25.6
-28.0
5
Int
108
67
7
25.6
-28.0
6
Int
96
67
7
25.8
-28.2
7
Int
96
67
7
25.8
-28.2
SCANNED
BY
St. Lucie County
BAN 2 2 2019
ST, Lucre County, perrnittin9
Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code.
Page 1 of 1