HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONS���eForce St L cie NED HURRICANE SHUTTERS, INC. County PANELS • ACCORDIONS • BAHAMAS Information Owner: Kings Plaza Address: 7630 South Federal Highway Port Saint Lucie, F134952 Information Wind Zone: 170 MPH. Exposure Category: B Minimum Building Dimension: 5 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Number Location Zone Device Width (m) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 68 67 7 26.4 -33.8 2 Int 157 67 7 24.9 -27.3 3 Int 172 67 7 24.7 -27.1 4 Int 108 67 7 25.6 -28.0 5 Int 108 67 7 25.6 -28.0 6 Int 96 67 7 25.8 -28.2 7 Int 96 67 7 25.8 -28.2 SCANNED BY St. Lucie County BAN 2 2 2019 ST, Lucre County, perrnittin9 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1