HomeMy WebLinkAboutPRODUCT APPROVAL'Florida Building Code Online ` Page 1 of 3
Business m -h li
&ProfessionalRegulation
aaS Home Log In i User Registration Hot Topics Submit surcharge state a Facts PubUmUora FK staff i DCIS site Map Unla I Search
a
d , r
�l �Product USER: Pubft UserrDVE11
RECEIVED
Pmdud AOOmval Menu > Product Or APnlndMan
Search > AoolimM00 List > Application Detail
'
JAN 14 2019
FL#
FL1850-1111
Application Type
Revision
ST. Lucie County, Permitting
Code Version
2017
Application Status
Approved
,
Comments
Archived
Product Manufacturer American Shutter Systems Association, Inc.
Address/Phone/Email 4268 Westroads Drive
West Palm Beach, FL 33407
(561) 209-8263
bfeeley@easternmetal.com
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory'
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
•Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Bill Feeley
Irodriguu@eastemmetal.com
SCANNED
BY
St. Lucie Countv
Shutters
Accordion
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report T Hardcopy Received
Walter A. Tillit, Jr., P.E.
PE-44167
National Accreditation and Management Institute
12/31/2018'
John Henry Kampmann Jr. .
66 Validation Checklist— Hardcopy Received
FL1850 R11 COI AMERICAN SHUTTER SYSTEMS INC DRAWING 17-
102102CER��CA�OF INDEPENDENCE.PDFINDEPENDENCE.PDF
Referenced Standard and Year (of Standard) Standard
ASTM E1886
ASTM E1996
ASTM E330
TAS 201, 202, 203
Equivalence of Product Standards
Certified By
Sections from the Code
Year
2005
2005
2002
1994
https://floridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgs9%2fllo2ftCOhpJQ... 3/24/2018
Florida Building Code Onl L
Page 2' of 3'
Product Approval Method Method 1 Option D
Date Submitted 10/03/2017
Date Validated 10/13/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/12/2017
FL * I Model. Number or Name
1850.1 Bertha HV Accordion -Blade 3
(HVHZ) Drawing# 17-103
Description
Extruded aluminum blades folded together thru knuckles
retained by tracks to provide hurricane protection.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FLIB50 R11 11 AMERICAN H T M A
Approved for use outside HVHZ: Yes
INC. DRAWING 17-103 BERTHA HV ACCORDION SHUTTER
Impact Resistant: Yes
SYST..PDF
Design Pressure: N/A
Verified By: American Test Lab of South Florida Inc.
Other: Large Missile Level "D". Max span is 12'-7" for 35
Created by Independent Third Party: Yes
psf positive ASD load and 13'-0" for 35 psf negative ASD
Evaluation Reports
load for one specific condition shown in span tables. See
FL1850 RI AE AMERICAN SHUTTER SYSTEMS ASSOC..
additionalloads and spans on engineered drawings.
INC. DRAWING 17-103 PRODUCT EVALUATION
REPORT.PDF
Created by Independent Third Parry: Yes
1850.2
Bertha HV Accordion Shutter
Extruded aluminum Interlocking blades retained by tracks
(Combo) - HVHZ - Drawing#17-102
(top and bottom) for storm protection
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large Missile Level "D'. Max. span is 13'-2" for 30
psf positive ASD load w/o window blade, 16'-0" for 30 psf
negative ASD load for HVS blade w/o window blade for
conditions indicated on schedule #1, sheet 12. And 12'-3'
for 30 psf positive ASD load w/o window blade and 15'-5 for
30 psf negative ASD load for HV2 blade w/o window blade.
See sheets number 12, 25, 28 and 28A of installation
drawings for other spans and pressures.
1850.3 Bertha HV Accordion Shutter -
Blade 1 Only (HVHZ) - Drwg# 17-
122
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large missile level "D". Max. span is 16' 0' and
14'-9" for 30 psf ASD negative load depending on
centennates and locking rod configuration for the HVl blade,
8'-0" for +64, -72 psf load for HV blade for Keystone
mountings 7'-0" for +75, -75 psf for metals stud mountings
and 8'-0" for 110 psf. for HV3 and HV1A working in unison.
See sheets 7, IS, 20 and 19 respectively of installation
drawings for other spans and pressures.
Installation Instructions
FL1850 R11 If AMERICAN SHUTTER SYSTEMS, INC.
DRAWING 17-102 BERTHA HV ACCORDION SHUTTER
SYSTEM.PDF
Verified By: American Test Lab of South Florida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL1850 R11 AE AMERICAN SHUTTER SYSTEMS,INC.
DRAWING 17-102 PRODUCT EVALUATION REPORT.PDF
Created by Independent Third Party: Yes
Extruded aluminum interlocking blades retained by tracks
(top and bottom) for storm protection
Installation Instructions
FL1850 1 II AMERICAN SHUTTER SYSTEMS ASSOC.
INC DRAWING 17-122 BERTHA HV ACCORDION
SYST..PDF
Verified By: American Test Lab of South Florida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL1850 RI I AE AMERICAN SHUTTER SYSTEMS ASSOC,
INC DRAWING 17-122 PRODUCT EVALUATION
REPORT.PDF
Created by Independent Third Party: Yes
axk Neat
Cents& Us :: 26DI Blair Stone Road. -relishes. FL 32399 Pbone: 850-087-1824
The State of Rodda Is an AA7EE0 employer. Coovmht 2007-2013 State of Florida.:: Pdvacv statement :: Amcsiblllty statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response M a pubik-records request, do not send
electronic mall M Mts entity. Instead, contact Me office by phone or by traditional man. If you have any qursdom, please contact 850.487.1395. *Pursuant M
section 455.275(1), Flodda Sta
tutes, effective O¢ober 1, 2012, licensees roamed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emalk provided may be used for official communication with the homem. However email addresser are public record. If you d4 not wish to
supply a personal address, please provide Me Department with an email address which can be made available to Me public. To determine if you are a Ilansee under .
Chapter 455, F.5., please dick bets.
Proudest Approval Accepts:
"M N ® ® a
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs9%2f%2ftCOhpJQ... 3/24/2018