HomeMy WebLinkAboutMISC LETTERArchitectonic Inc
January 25, 2019
St. Lucie County SCANNED
Planning & Development Services BY
Building & Code Regulation Division St. Lucie County
2300 Virginia Avenue
Fort Pierce, FL 34982
Re: Roofing specification prepared for the St, Lucie County for the structure located at, 281
Tropical Isles Circle, Fort Pierce, FL 34982
Manufacturer:
Profiles:
Code:
Wind Speed:
Exposure:
Mean Roof Height:
Pitch:
JA Taylor Roofing
5-V Crimp 24 ga. Steel, FL#17443.1
FBC 2017
165MPH; Ultimate Design Wind Speeds
C
30' Maximum
5 / 12 Minimum
Required Design Pressure: Zone1: -30.92 Zone 2: -51,55 Zone3: -77.32
Maximum Uplift Pressure: -69.25 @ 16" o.c. Zone 1 & 2, Zone 3-129.25 @ 6" o.c.
Fasteners: #9-15x1.6" @ 16" O.C. with sealing washer through panel rib with''/."
minimum penetration through plywood
Underiayment: 30# felt w/ 1-1/4" annular ring shank roofing nails w/ 32 ga. tin tabs @
6" o.c. perimeter & 12" o.c. field
Roof Decking: Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank
@ 6" O.C. thru out zone 1, 4" D.C. perimeter, and 6" O.C. field zone 2,
and 4" O.C. thru out zone 3.
The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code,
and the Manufacturer's recommendations.
ST. LUCIE COI
BUILDING DIVI
FOR
MtlST BE TON JOB OR
NO INSPECTION WILL BE MADE
Archite rd ED ARC' XNCFALED FASTENERS ORAITACHMEHiS ORRE
THESE PLANS AWILI L PROPQSCD WORK
ARE SUWECT TO ANY CCTIONS
ARE THE RESPONSIBILITY OF THE REQUIRED BYFIRD INSPECTORS THAT
CONTRACTOR OF RECORD MAYM RECESMY IN ORDER TO
COMPLY WITH ALL APPLICPaV.. CODES.
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1