HomeMy WebLinkAboutMISC LETTERArchitectonic Inc January 25, 2019 St. Lucie County SCANNED Planning & Development Services BY Building & Code Regulation Division St. Lucie County 2300 Virginia Avenue Fort Pierce, FL 34982 Re: Roofing specification prepared for the St, Lucie County for the structure located at, 281 Tropical Isles Circle, Fort Pierce, FL 34982 Manufacturer: Profiles: Code: Wind Speed: Exposure: Mean Roof Height: Pitch: JA Taylor Roofing 5-V Crimp 24 ga. Steel, FL#17443.1 FBC 2017 165MPH; Ultimate Design Wind Speeds C 30' Maximum 5 / 12 Minimum Required Design Pressure: Zone1: -30.92 Zone 2: -51,55 Zone3: -77.32 Maximum Uplift Pressure: -69.25 @ 16" o.c. Zone 1 & 2, Zone 3-129.25 @ 6" o.c. Fasteners: #9-15x1.6" @ 16" O.C. with sealing washer through panel rib with''/." minimum penetration through plywood Underiayment: 30# felt w/ 1-1/4" annular ring shank roofing nails w/ 32 ga. tin tabs @ 6" o.c. perimeter & 12" o.c. field Roof Decking: Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank @ 6" O.C. thru out zone 1, 4" D.C. perimeter, and 6" O.C. field zone 2, and 4" O.C. thru out zone 3. The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the Manufacturer's recommendations. ST. LUCIE COI BUILDING DIVI FOR MtlST BE TON JOB OR NO INSPECTION WILL BE MADE Archite rd ED ARC' XNCFALED FASTENERS ORAITACHMEHiS ORRE THESE PLANS AWILI L PROPQSCD WORK ARE SUWECT TO ANY CCTIONS ARE THE RESPONSIBILITY OF THE REQUIRED BYFIRD INSPECTORS THAT CONTRACTOR OF RECORD MAYM RECESMY IN ORDER TO COMPLY WITH ALL APPLICPaV.. CODES. 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1