Loading...
HomeMy WebLinkAboutPRODUCT REPORTSCANNED BY St. Lucie County Fort Pierce, FL 34962 (772)466-4040 Compliant with Florida Building Code 2017 (616 ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant Quality Assurance Program: PRI CONSTRUCTION MATERIALS TECHNOLOGY FBC Sections: 1504.3.2. IS07 5V Crimp thru fastened A" rib at each panel edge and 1 fastener in the center of the panel, 24" net coverage, 26GA ASTM A79Z G-50, AZ55, .018, SOksi min. over m1n. 25/320 thick COX plywood deck. Corrosion Resistant fastener 119-15 HWH with sealing washers, metal to wood connections with fastener length to penetrate 5/16" thru substrate. Fasten along the crown of the nb in the center of panel and along the lap. First fastener to be within 3" of panel edges. Min.80x2" annular ring shank nails spaced 6" D.C. reroofing, with less than 19/32" plywood (mIn.1S/32"), this attachment is to be used in addition to existing attachment. Deck slope 2:12 or greater and shall be tom Ilan with F8C 2017 6TM ed. Undedayment: See FBC 2027 6TM ed., Sec 1507 Table 1507.1.1 •"Design Pressure: Sparing: -69.25 PSF 16" O.C. -129.25 PSF 6" O.C. Corrosion Resistant Fastener#10 x 1" Zinc plated, MMI Pancake Head, installed at 2 per panel into lock seam. Panels applied with 12" exposure, adjacent shingles Inserted into lock seam of previous shingle. Deck slope 2:12 or greater and shall be compliantwith FOC 2017 61" ed. Underlayment: See FBC 2017 6r"ed., Sec 1507 Table 1507.1.1 '•Deli n Pressure: 105 PSF Reference Data: TEST REPORTS Hurricane Test Laboratory (TST-1527) #0224-0501-06 TAS 125 (UL 580-941) PRI Construction Materials Technologies (TST-5878) #FAE-023-02-01 UL 580-06/UL 1897-041 1. UL 580-94 teststandards are equivalent to UL 580.06 test standards. 2. UL 1897-04 test standards are equivalent to UL 1897-12 test standards. 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 67H ed.. see Chart 2507.1.1 2. Minimum slope to be compliant with Florida Building Code 2017 6n' ed., and per with Manufacturers installation reference. 3. Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities wrurisdiction is allowed by other registered engineers. S. Fire classification is not part of this acceptance. Sheardiaphragm values are outside this report. 6. Support framing in compliance w/FBC2017 601 ed., Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial Interest in any company manufactur%Tfillil uting products under this evaluation. +++P+ 1504Vnf7grr Locke Bowden, P.E. is not owned, operated, or controlled by any company, manufacturer, or irk IQ pr��,�^-i r this report. E y°•�•y. SSPJF p 001-LW- ••••. 5 V Crimp Fastener-#9-15 corrosion resistant wlsealing washers 24'coveraoe Fastener: #9 x 15 corrosion resistant with sealing washers in Compliance with 2017 Florida Building Code, Section 1507 Perimeter fastening: 6"o.c. Main Field fastening 1 2"o.c. Panel Width: 26" Panel Coverage: 24"maximum 26 GA Architectural Metal Roof panel VICTORIAN CRIMP MINIMUM 2 FASTENERS AT LOCK SEAM ) CUT 112 SHINGLE REATE STAGGERED 'ERN ORIAN CRIMP IGLES I �� 9"EXPOSURE D w O N Fastener:#10x 1" Zinc Plated MTW Pancake Head