HomeMy WebLinkAboutNOA3343 S US Highway 1, Fort Pierce, FL 34982 MIAI�l4 FI L'PRMW a�b PY MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC SOURCE (RER) / ��/( 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION -(71—� l `r Miami, Florida 33175-2474 (j� T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE www.miamidade.gov/economy Tamko Building Products, Inc. SCANNED 220 West 4's Street JAN 2, 2 �, Ji9 BY Joplin, MO 64801 St. Lucie County i ST. Lucie County, Permitting SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: TAMKO Modified Bitumen Roof System over Concrete Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA No.12-0716.17 and consists of pages I through 14. The submitted documentation was reviewed by Gaspar J Rodriguez. NOA No.: 14-0827.19 Expiration Date: 10/23/21 Approval Date: 07/28/16 Page 1 of 14 3343 S US Highway 1, Fort Pierce, FL 34982 See Page 11 ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category: Modified Bitumen Material: SBS Deck Tvne: Concrete Maximum Design Pressure: -622.5 PSF TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Awaplan' 39'/8" wide ASTM D6164 Polyester reinforced SBS modified membrane Type I surfaced with granules. Applied in hot asphalt or cold adhesive. Glass -Base' 39 %" wide ASTM D4601 Type 11 asphalt impregnated and coated glass fiber Type I1 base sheet for use in conventional and modified bitumen built-up roofing. Tam -Cap' 391/8" wide ASTM D3909 Asphalt impregnated and coated felt surfaced with mineral granules used as the top ply in conventional built-up roof membranes. Tam -Ply IV' 39 3/8" wide ASTM D2178 Type IV asphalt impregnated glass felt for use in Type IV conventional and modified bitumen built-up roofing. Type 43 Base Sheet 36" wide ASTM D2626 An organic felt reinforced asphalt base sheet. Applied in hot asphalt or mechanically fastened. Versa -Base' 39 %" wide ASTM D6163 Asphalt impregnated and coated glass fiber base Type I sheet for use in conventional and modified bitumen built-up roofing. Tam -Pro 846 5 gallon ASTM D1227 Protective coating. Fibered Emulsion Type II Coating Tam -Pro 813 5 gallon ASTM D41 Asphalt based primer Asphalt Primer NOA No.: 14-0827.19 Expiration Date: 10/23/21 Approval Date: 07/28/16 Page 2 of 14 3343 S US Highway 1, Fort Pierce, FL 34982 See Page 11 APPROVED INSULATIONS: Product Name ACFoam II ACFoam Composite DensDeck ENRGY 3 ENRGY 3 25 PSI Fesco Board Retro-Fit Board Structodek High Density Fiberboard Roof Insulation H-Shield H-Shield-WF APPROVED FASTENERS: TABLE 2 Product Description Polyisocyanurate insulation Polyisocyanurate insulation with perlite facer Gypsum insulation board Polyisocyanurate insulation Polyisocyanurate insulation Expanded perlite and fiber insulation Expanded perlite and fiber insulation High Density Wood Fiber insulation board. Polyisocyanurate insulation Wood fiber/Polyisocyanurate Composite Insulation Manufacturer (With Current NOA) Atlas Roofing Products Atlas Roofing Products Georgia-Pacific Gypsum LLC Johns Manville Corp. Johns Manville Corp. Johns Manville Corp. Johns Manville Corp. Blue Ridge Fiberboard Hunter Panels LLC Hunter Panels LLC TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. #14 Roofgrip Insulation fastener for wood, OMG Inc. steel and concrete decks. 2. #15 Roofgrip Insulation fastener for wood, 3" round OMG Inc. steel and concrete decks. 3. OMG Heavy Duty Insulation fastener OMG Inc. 4. AccuTrac Plate Galvalume AZ50 steel plate 3" square OMG Inc. 5. 3" Round Metal Plate Galvalume AZ50 steel plate 3" round OMG Inc. 6. #14 Dekfast Insulation fastener for wood, SFS Intec Inc. steel and concrete decks 7. #15 Dekfast Insulation fastener for wood, SFS Intec Inc. steel and concrete decks 8. Dekfast 3" Round a va ume AZ50 steel plate 3" round ­SFSIntec Inc. Steel Insulation Plate 9. Tru-Fast #14 HD Insulation fastener for wood, Altenloh, Brinck & Co. U.S., steel and concrete decks Inc. 10. Tru-Fast 3" Metal 3" round galvalume AZ55 3" round Altenloh, Brinck & Co. U.S., Insulation Plates steel plate Inc.. We always use Dekfast or Tru-Fast but it really depends on which one our supplier has in stock NOA No.: 14-0827.19 MIAMMADECOUNTY Expiration Date: 10/23/21 i Approval Date: 07/28/16 Page 3 of 14 3343 S US Highway 1, Fort Pierce, FL 34982 See Page 11 EVIDENCE SUBMITTED: Test Agency Test Name/Report Test Identifier Date Underwriters Laboratories, Inc. UL 790 R3225 10/03/12 Factory Mutual Research Corp. Class 4470 J.I.4DOA7.AM 10/21/98 Class 4470 J.I. OZ,4A3.AM 08/27/97 Class 4470 J.I.1D4A7.AM 10/20/97 Class 4470 J.I. 3135A9.AM 08/27/98 Class 4470 3027787 08/14/06 Class 4470 3027789 08/14/06 Class 4470 3027790 08/14/06 Class 4470 3010612 04/16/01 797 797-09988-267 12/11/14 Class 4470 3027791 08/14/06 Dynatech Engineering Corp. TAS 114 4440.05.95-2 05/01/95 TAS 114 4440.05.95-1 05/01/95 Exterior Research & Design, LLC TAS 114 4444.06.98-1 06/15/98 TAS 114 4441.04.99-1 04/09/99 Trinity ERD TAS 117 C8500SC.00.07 1 I/30/07 TAS 117 & TAS 114 C12410.08.09 08/14/09 ASTM D 4601 Type 11 SC10960.02.16-1 02/11/16 ASTM D 2178 Type IV SC10960.02.16-2 02/11/16 ASTM D 3909 SC10960.02.16-3 02/11/16 PRI Construction Materials ASTM D 6163 TAP-254-02-02 01/24/12 Technologies LLC ASTM D 4601 TAP-255-02-02 11/04/11 ASTM D 2178 TAP-256-02-02 11/04/11 ASTM D 6164 TAP-298-02-01 11/10/15 ASTM D 3909 TAP-257-02-03 11/18/11 ASTM D 2626 TAP-257-02-01 12/12/11 NOA No.: 14-0827.19 Expiration Date: 10/23/21 Approval Date: 07/28/16 Page 4 of 14 3343 S US Highway 1, Fort Pierce, FL 34982 See Page 11 APPROVED ASSEMBLIES: Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A: One or more layers of insulation adhered with approved asphalt. All General and System Limitations apply. One or more layers of any of the following insulations: Base Insulation Layer ACFoam II, ENRGY 3, ENRGY 3 25 PSI, H-Shield Minimum 1.5" thick Top or Base Insulation Layer DensDeck Minimum 1/4" thick Structodek High Density Fiberboard, Fesco Board, Retro-Fit Minimum 1/2" thick ACFoam Composite, H-Shield-WF Minimum 1.5" thick Insulation Fasteners Fastener (Table 3) Density/ft2 N/A N/A Insulation Fasteners Fastener (Table 3) Density/ft2 N/A N/A N/A N/A N/A N/A Note: Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry prior to application of base sheet. All insulation shall be adhered to the deck in full mopping of approved asphalt within the EVT range and at a rate of 20-40 lbs/100 ft'. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels used as a top layer shall be placed with the polyisocyanurate side facing down. Base Sheet: (Optional) One ply of Glass -Base or Versa -Base, adhered to the substrate with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Ply Sheet: One or more plies of Tam -Ply IV, Glass -Base or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. NOA No.: 14-0827.19 MIAMMADECOUNTY Expiration Date: 10/23/21 �FjuzoApproval Date: 07/28/16 Page 5 of 14 3343 S US Highway 1, Fort Pierce, FL 34982 See Page 11 Membrane: Awaplan adhered with a full mopping of approved asphalt applied at 400' F at the point of contact, at a rate of 20-40 lbs./sq. Surfacing: Optional for mineral surfaced Membranes. Required for smooth surfaced membranes. Any coating, listed below, used as a surfacing, must be listed within a current NOA. 1. 400 lb./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq.. 2. Henry 520 or Karnak 97AF applied at 1'/2 gal./sq., or Grundy Fibered Asphalt Emulsion, or Tam -Pro 846 Fibered Emulsion at 3 gal./sq. Maximum Design Pressure: -222.5 psf. (for minimum 1.5" thick Approved polyisocyanurate followed by minimum 3/4" thick Approved perlite applied in hot asphalt.) (See General Limitation 49) -230 psf. (for minimum 1.5" thick Approved polyisocyanurate followed by minimum''/4" thick DensDeck or minimum %2" Structodek High Density Fiberboard Roof Insulation applied in hot asphalt.) (See General Limitation #9) -265 psf. (for minimum 1.5" thick Approved polyisocyanurate followed by minimum %2" thick Structodek High Density Fiberboard Roof Insulation applied in hot asphalt.) (See General Limitation #9) -200 psf. (for minimum 1.5" thick ACFoam II Composite or H-Shield-WF applied in hot asphalt.) (See General Limitation #9) -230 psf. (for minimum %4" thick DensDeck applied in hot asphalt with no underlying insulation.) (See General Limitation #9) -80 psf (minimum %2" thick any combination of approved isocyanurate, perlite, or wood fiber applied in hot asphalt.) (See General Limitation #9) -210 psf. (for minimum'/2" thick Retro-Fit applied in hot asphalt with no underlying insulation.) (See General Limitation #9) -240 psf. (for minimum %2" thick Retrofit applied in hot asphalt with no underlying insulation. Requires one ply of Versa -Base.) (See General Limitation #9) -330 psf. (for minimum %2" thick Structodek High Density Fiberboard Roof Insulation applied in hot asphalt with no underlying insulation.) (See General Limitation #9) -382.5 psf. (for minimum %2" thick Structodek High Density Fiberboard Roof Insulation applied in hot asphalt with no underlying insulation. Requires one ply of Versa - Base.) (See General Limitation #9) NOA No.: 14-0827.19 Expiration Date: 10/23/21 Approval Date: 07/28/16 Page 6 of 14 3343 S US Highway 1, Fort Pierce, FL 34982 See Page 11 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type B(1): Base layer of insulation mechanically fastened; top layer adhered with approved asphalt. All General and System Limitations apply. One or more layers of any of the following insulations: Base Insulation Layer ACFoam II, H-Shield Minimum 1.2" thick ACFoam II Minimum 1.4" thick ACFoam Composite Minimum 1.5" thick ENRGY 3, ENRGY 3 25 PSI Minimum 1.4" thick Fesco Board, Structodek High Density Fiberboard Minimum 1" thick Insulation Fasteners Fastener (Table 3) Density/ft' 1,2,5,6,7,8,9,10 1:2ft.' 1, 2, 5, 6, 7, 8, 9, 10 1:4 ft.2 1, 2, 5, 6, 7, 8, 9, 10 1:4 ft.2 1,2,5,6,7,8,9,10 1:2ft' 1, 2, 5, 6, 7, 8, 9, 10 1:2 ft.' Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening details). (Optional) Top Insulation Layer Fesco Board, Retrofit Minimum%" thick ACFoam Composite, H-Shield-WF Minimum 1.5" thick Insulation Fasteners Fastener (Table 3) Density/ft' N/A N/A N/A N/A Note: Apply top layer of insulation in a full mopping of any approved mopping hot asphalt within the EVT range and at a rate of 20-40 lbs/100 It'. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as Base Layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: (Optional) One ply of Glass -Base or Versa -Base adhered to the substrate with a full mopping of approved asphalt applied within the EVT range, at a rate of 20-40 lbs./sq. NOA No.: 14-0827.19 Expiration Date: 10/23/21 Approval Date: 07/28/16 Page 7 of 14 3343 S US Highway 1, Fort Pierce, FL 34982 See Page 11 Ply Sheet: One or more plies of Glass Base, Tam -Ply IV or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range, at a rate of 20-40 lbs./sq. Membrane: Awaplan adhered with a full mopping of approved asphalt applied at 400' F at the point of contact, at a rate of 20-40 lbs./sq. Surfacing: Optional for mineral surfaced Membranes. Required for smooth surfaced membranes. Any coating, listed below, used as a surfacing, must be listed within a current NOA. 1. 400 lb./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq.. 2. Henry 520 or Karnak 97AF applied at lY: gal./sq., or Grundy Fibered Asphalt Emulsion, or Tam -Pro 846 Fibered Emulsion at 3 gal./sq. Maximum Design Pressure: -45 psf. (See General Limitation #9.) NOA No.: 14-0827.19 MIAMI-DADECOUNW Expiration Date: 10/23/21 • • • . e Approval Date: 07/28/16 Page 8 of 14 3343 S US Highway 1, Fort Pierce, FL 34982 See Page 11 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type B(2): Base layer of insulation mechanically fastened; top layer adhered with approved asphalt. All General and System Limitations apply. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' ACFoam II, ENRGY 3, ENRGY 3 25 PSI, H-Shield Minimum 1.5" thick 1 or 6 1:1.33 ft.2 Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening details). Top Insulation Layer Structodek High Density Fiberboard Minimum''/2" thick Insulation Fasteners Fastener (Table 3) Density/ft' N/A N/A Note: Apply top layer of insulation in a full mopping of any approved mopping hot asphalt within the EVT range and at a rate of 20-401bs/100 ft'. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as Base Layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: (Optional) One ply of Glass -Base or Versa -Base adhered to the substrate with a full mopping of approved asphalt applied within the EVT range, at a rate of 20-40 lbs./sq. Ply Sheet: One or more plies of Glass Base, Tam -Ply IV or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range, at a rate of 20-40 lbs./sq. Membrane: Awaplan adhered with a full mopping of approved asphalt applied at 400' F at the point of contact, at a rate of 20-40 lbs./sq. Surfacing: Optional for mineral surfaced Membranes. Required for smoothsurfaced membranes. Any coating, listed below, used as a surfacing, must be listed within a current NOA. 1. 400 lb./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq.. 2. Henry 520 or Karnak 97AF applied at 1 % gal./sq., or Grundy Fibered Asphalt Emulsion, or Tam -Pro 846 Fibered Emulsion at 3 gal./sq. Maximum Design Pressure: -75 psf (See General Limitation 97.) NOA No.: 14-0827.19 Expiration Date: 10/23/21 Approval Date: 07/28/16 Page 9 of 14 3343 S US Highway 1, Fort Pierce, FL 34982 See Page 11 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type C: All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations: Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ftz ACFoam II, H-Shield, ENRGY 3, ENRGY 3 25 PSI Minimum 1.5" thick N/A N/A Note: All layers shall be simultaneously attached; see top layer below for fasteners and density. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' Fesco Board, Structodek High Density Fiberboard Minimum I" thick 1, 2, 5, 6, 7, 8, 9,10 1:2 ft.' Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: (Optional) One ply of Glass -Base or Versa -Base adhered to the substrate with a full mopping of approved asphalt applied within the EVT range, at a rate of 20-40 lbs./sq. Ply Sheet: One or more plies of Glass Base, Tam -Ply IV or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range, at a rate of 20-40 lbs./sq. Membrane: Awaplan adhered with a full mopping of approved asphalt applied at 400' F at the point of contact, at a rate of 20-40 lbs./sq. Surfacing: Optional for mineral surfaced Membranes. Required for smooth surfaced membranes. Any coating, listed below, used as a surfacing, must be listed within a current NOA. 1. 400 lb./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq.. 2. Henry 520 or Karnak 97AF applied at 1 %: gal./sq., or Grundy Fibered Asphalt Emulsion, or Tam -Pro 846 Fibered Emulsion at 3 gal./sq. Maximum Design Pressure: -45 psf. (See General Limitation #9.) NOA No.: 14-0827.19 Expiration Date: 10/23/21 Approval Date: 07/28/16 Page 10 of 14 3343 S US Highway 1, Fort Pierce, FL 34982 See Paae 11 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type D: Base sheet attached over insulation. All General and System Limitations apply. One or more layers of any of the following insulations: Insulation Layer ACFoam II, H-Shield, ENRGY 3, ENRGY 3 25 PSI Minimum 1.5" thick Fesco Board Insulation Fasteners Fastener (Table 3) Density/ft' N/A N/A Minimum'/" thick N/A N/A Structodek High Density Fiberboard Minimum'/2" thick N/A N/A Note: Top layer shall have preliminary attachment, prior to the installation of the base/anchor sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Base Sheet: One ply of Tamko Glass -Base fastened to the deck as described in Option # 1 or #2, below. Fastening: (Option #1) Attach anchor sheet using 914 or #15 Dekfast Fasteners with 3" Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two staggered rows in the center of the sheet. Maximum Design Pressure —60 psf., (See General Limitation #7.) (Option #2) Attach anchor sheet using, or OMG #14 or #15 Roofgrip Fasteners and 3" Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two staggered rows in the center of the sheet. Maximum Design Pressure —75 psf., (See General Limitation #7.) Ply Sheet: (Optional) One or more plies of Glass Base, Tam -Ply IV or Versa -Base adhered with a full Membrane: mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. wap an a ere With a full mopping of approved asphalt applied at at t e point o contact, at a rate of 20-40 lbs./sq. Surfacing: Optional for mineral surfaced Membranes. Required for smooth surfaced membranes. Any coating, listed below, used as a surfacing, must be listed within a current NOA. 1. 400 lb./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq.. 2. Henry 520 or Karnak 97AF applied at 1 %: gal./sq., or Grundy Fibered Asphalt Emulsion, or Tam -Pro 846 Fibered Emulsion at 3 gal./sq. Maximum Design Pressure: See Base Sheet Fastening Options. Customer chose fibered aluminum coating for top coat. Karnak 97AF NOA No.: 14-0827.19 Expiration Date: 10/23/21 Approval Date: 07/28/16 Page 11 of 14 3343 S US Highway 1, Fort Pierce, FL 34982 See Page 11 Membrane Type: SBS Deck Type 3: Concrete Decks, Non -insulated Deck Description: 2500 psi structural concrete or concrete plank System Type E: Base sheet mechanically attached. All General and System Limitations apply. Base Sheet: One ply of Tamko Glass -Base fastened to the deck as described in Option #1 or 42, below. Fastening: (Option #1) Attach anchor sheet using #14 or #15 Dekfast Fasteners with 3" Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two staggered rows in the center of the sheet. Maximum Design Pressure —60 psf., (See Genera[ Limitation #7.) (Option #2) Attach anchor sheet using, or OMG # 14 or #15 Roofgrip Fasteners and 3" Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two staggered rows in the center of the sheet. Maximum Design Pressure —75 psf., (See Genera[ Limitation #7.) Ply Sheet: (Optional) One or more plies of Glass Base, Tam -Ply IV or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range, at a rate of 20-40 lbs./sq. Membrane: Awaplan adhered with a full mopping of approved asphalt applied at 4000 F at the point of contact, at a rate of 20-40 lbs./sq. Surfacing: Optional for mineral surfaced Membranes. Required for smooth surfaced membranes. Any coating, listed below, used as a surfacing, must be listed within a current NOA. 1. 400 lb./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 601b./sq.. 2. Henry 520 or Kamak 97AF applied at 1 %2 gal./sq., or Grundy Fibered Asphalt Emulsion, or Tam -Pro 846 Fibered Emulsion at 3 gal./sq. Maximum Design Pressure: See Base Sheet Fastening Options. NOA No.: 14-0827.19 Expiration Date: 10/23/21 Approval Date: 07/28/16 Page 12 of 14 3343 S US Highway 1, Fort Pierce, FL 34982 See Page 11 Membrane Type: SBS Deck Type 3: Concrete Decks, Non -Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type F: Membrane adhered with approved asphalt. All General and System Limitations apply. Note: Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry prior to application of anchor sheet. Base Sheet: (Optional) One ply of Glass -Base or Versa -Base adhered to the substrate with a full mopping of approved asphalt applied within the EVT range, at a rate of 20-40 lbs./sq. Ply Sheet: One or more plies of Glass Base, Tam -Ply IV or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range, at a rate of 20-40 lbs./sq. Membrane: Awaplan adhered with a full mopping of approved asphalt applied at 400' F at the point of contact, at a rate of 20-40 lbs./sq. Surfacing: Optional for mineral surfaced Membranes. Required for smooth surfaced membranes. Any coating, listed below, used as a surfacing, must be listed within a current NOA. 1. 400 lb./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq.. 2. Henry 520 or Karnak 97AF applied at 1 %2 gal./sq., or Grundy Fibered Asphalt Emulsion, or Tam -Pro 846 Fibered Emulsion at 3 gal./sq. Maximum Design Pressure: -622.5 psf. (See General Limitation #9.) NOA No.: 14-0827.19 MIAMI•DADE COUNTY Expiration Date: 10/23/21 Approval Date: 07/28/16 Page 13 of 14 3343 S US Highway 1, Fort Pierce, FL 34982 See Page 11 CONCRETE DECK SYSTEM LIMITATIONS: 1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117; calculations shall be signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf, as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 Ibf. Insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 14-0827.19 MIAMI-DADE COUNTY Expiration Date: 10/23/21 UnTsymi Approval Date: 07/28/16 Page 14 of 14