HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSAMER
MRS &
Read, West Palm Beach, FL
taai,t liz-btftiz * fiywwailamellcannutlers.cam
Property Information L Building Information
Owner: LOCKSTADT, CORNELLA Wind Zone: 170 MPH.
Address: 3000NHIGHWAYAlA Exposure Category: D
PENTHOUSE A Minimum Building Dimension: 160 ft.
FORT PIERCE, FL 34949 Mean Roof Height: 112 ft.
Risk Category: III
Design Pressure Calculations
enin Location
O P g
Number J Zone
Device
Width (in)
Device
L Height (in)
Device
I Elevation (ft)
Max Positive
Pressure (psf)
Max Negative
IL Pressure (psf)
1
2 _
Int
Int
73 117 105
0
53.5
53.5
-55.8
-55.8
3
Int
73 117 105
53.5
_
-55.8
4
Int
706 117 105
42.6
-48.5
5
Int
0
_
42.6
-48.5
FILE COPY
Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code.
Page 1 of 1