Loading...
HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSALL AMERICAN I SHUTTERS & GLASS 1838 Donna Road, Mst Palm Beach, FL 33409 (581) 712-9882 • m maltamerlcanshutters.cem R 2 a ✓9,y2 , FO se. z4i�9 1p1g <dc7NOdpd co�n�5,,d't Property Information Building Information Owner: VOSTERS, JAMES Wind Zone: 170 MPH. Address: 3000 N HIGHWAY AlA Exposure Category: D APT 8B Minimum Building Dimension: 160 ft. FORT PIERCE, FL 34949 Mean Roof Height: 112 ft. Risk Category: III Design Pressure Calculations Opening Number Location Zone Device Width (m) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Neg�i Pressure s 1 Int 408 102 72 41.8 -49.4 2 Int 72 41.8 -49.4 FILE COPY SCANNED BY St. Lucie County Prepared in accordance with: ASCE 7-10, Chapter 30, If ind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1