Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PRODUCT APPROVAL
Florida Building Code Online ' 1/22119, 12:17 PM t, Business & Professional Regulation t 10� BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge Stats & Facts I Pudicaticns I Contact Us BQS Site Map I Links Search I dbpr ` Product Approval 0 USER: Public User Product Approval Menu > Product er Aoolicatim Search > Application List > Application Detail FL # FL27150 Application Type New Code Version 2017 RECEIVED Application Status Approved JAN 3 0 2019 Comments Archived _ ST. Lucie County, Permitting Product Manufacturer INTEGRITY METALS Address/Phone/Email 2604 B Piper Drive Vero Beach, FL 32960 (772) 284-5613 fivalidation@yahoo.com Authorized Signature 3oe Keene fi v a l i d ati on @ya h o o. com Technical Representative Address/Phone/Email SCANNED BY Quality Assurance Representative St. Luce County Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Locke Bowden the Evaluation Report Florida License PE-49704 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 05/25/2025 Validated By Diane Marotta, P.E. 7 Validation Checklist - Hardcopy Received Certificate of Independence FL27150 RQWj FL27150 SV Crimp Min, 26GA Steel w Details - RSS.pdf Referenced Standard and Year (of Standard) Standard COP20yo TAS 125 UL 580 2006 Equivalence of Product Standards https:/Ifloridabuilding.org/pr/pr_app dti.aspx?param=wGEVXQwtDgsiWEgpVGlupCVZKm22%2bM%2bN%2bs42kUginbFYby94WM7fBA%3d%3d Page 1 of 4 Florida Building Code Online Certified By 1/22/1`9, 12:17 PM Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 06/20/2018 07/30/2018 07/31/2018 10/08/2018 FL # Model, Number or Name Description 27150.1 1.5 Versaloc 16oz Copper 1.5 1.5 Versaloc 16oz Copper 1.5 Mechanical Seam over min. Mechanical Seam 15/32" plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27150 RO II FL27150 1.5 Versaloc Mechanical Seam Min. 16oz Cooper w Details - RSS.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-159.25 Created by Independent Third Party: Yes Other: - 159.25 PSF @ 8" O.C. clip spacing Install per Evaluation Reports manufacturer's details and in accordance with FBC 2017. FL27150 RO AE FL27150 1.5 Versaloc Mechanical Seam Min. 16oz Cooper w Details - RSS.odf Created by Independent Third Party: Yes 27150.2 1.5 Versaloc 24GA Steel 1.5 1.5 Versaloc 24GA Steel 1.5 Mechanical Seam over min Mechanical Seam 15/32" plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27150 RO II FL27150 1.5 Versaloc Mechanical Seam Min. 24GA Steel w Details - RSS.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-189.25 Created by Independent Third Party: Yes Other: - 189.25 PSF @ 8" O.C. clip spacing forming 180 Evaluation Reports degree seam - 121 PSF @ 8" O.C. clip spacing forming 90 FL27150 RO AE FL271SO 1.5 Versaloc Mechanical Seam Min. 24GA Steel w Details - RSS.Ddf degree seam - 91.75 PSF @ 16" O.C. clip spacing Created by Independent Third Party: Yes 27150.3 1.5 Versaloc MIN .029" Aluminum 1.5 Versaloc MIN .029" Aluminum 1.5 Mechanical Seam over 1.5 Mechanical Seam min. 15/32" plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes EL27150 RO II FL27150 1.5 Versaloc Mechanical Seam Min Approved for use outside HVHZ: Yes 0,029 Aluminum w Details - RSS.Ddf Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-159.25 Created by Independent Third Party: Yes Other: - 114.25 PSF @ 16" O.C. clip spacing W/OUT sealant Evaluation Reports - 121.75 PSF @ 16" O.C. clip spacing W/ sealant - 159.25 PSF FL27150 RO AE FL27150 1.5 Versaloc Mechanical Seam Min. 0.029 Aluminum w Details - RSS.odf @ 8" O.C. clip spacing Install per manufacturer's details and in accordance with FBC 2017. Created by Independent Third Party: Yes 27150.4 IM675 Series: MIN .029" Aluminum IM675 Series: MIN .029" Aluminum 1.75 Snap Lock Roof 1.75 Snap Lock Roof Panel Panel over min. 15/32" 4-ply COX plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL27150 RO II FL27150 IM 675 Min, .029 Aluminum w Details - RSS.Ddf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-108.5 Created by Independent Third Party: Yes Other: - 108.5 PSF @ 18" O.C. clip spacing Install per Evaluation Reports manufacturer's details and in accordance with FBC 2017. FL27150 RO AE FL27150 IM 675 Mon- -029 Aluminum w Details - RSS.Ddf Created by Independent Third Party: Yes https://floridabuilding.org/prlpr app Otl.aspx?param=wGEVXQwtDgsWEgpVGlupCVZKm22%2bM%2bN%2bs42kUginbFYby94WM7fBA%3d%3d Page 2 of 4 Florida Building Code Online r 1122/19, 12:17 PM 27150.5 IM675 Series: Min. 26GA Steel 1.75 IM675 Series: Min. 26GA Steel 1.75 Snap Lock Roof Panel Snap Lock Roof Panel over min. 15/32" 4-ply CDX plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 Other: - 63.5 PSF @ 16" O.C. clip spacing - 93.5 PSF @ 12" O.C. clip spacing Install per manufacturer's details and in accordance with FBC 2017. 27150.6 I IntegriLok IM MIN .029" Aluminum Nail Strip Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86 Other: - 57.62 PSF @ 5-1/4" O.C. fastener spacing W/OUT sealant - 86 PSF @ 5-1/4" fastener spacing W/ sealant Install per manufacturer's details and in accordance with FBC 2017. 27150.7 I IntegriLok IM100 Min. 26GA Steel Nail Strip Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-71 Other: - 52.5 PSF @ 5-1/4" O.C. fastener spacing W/OUT sealant - 71 PSF @ 5-1/4" D.C. fastener spacing W/ sealant Install per manufacturer's details and in accordance with FBC 2017. 27150.8 I Min. 26GA Steel 5V Crimp Roof Panel Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86 Other: - 63.5 PSF @ 16" O.C. fastener spacing -86 PSF @ 12" O.C. fastener spacing Install per manufacturer's details and in accordance with FBC 2017. Installation Instructions FL27150 RO II FL27150 IM 675 Min. 26GA Steel w Details - RSS.Ddf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL27150 RO AE FL27150 IM 675 Min. 26GA Steel w Details iTSS.Ddf Created by Independent Third Party: Yes IntegriLok IM100 MIN .029" Aluminum Nail Strip over min. 15/32" 4-ply CDX plywood Installation Instructions FL27150 RO II FL27150 IntegriLok IM 100 Min. 0.029 Aluminum w Details - RSS.Ddf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL27150 RO AE FL27150 IntegriLok IM 100 Min. 0,029 Aluminum w Details - RSS Ddf Created by Independent Third Party: Yes IntegriLok IM100 Min. 26GA Steel Nail Strip over Min. 15/32" 4-ply CDX plywood Installation Instructions FL27150 RO II FL27150 IntegriLok IM 100 Min. 26GA Steel w Details - RSS.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL27150 RO AE FL27150 IntegriLok IM 100 Min. 26GA Steel w Details - RSS.edf Created by Independent Third Party: Yes Min. 26GA Steel 5V Crimp Roof Panel over min. 15/32" 4-ply CDX plywood Installation Instructions FL27150 RO II FL27150 SV Crimp Min. 26GA Steel w Details - RSS.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL27150 RO AE FL27150 5V Crimp Min. 26GA Steel w Details - RSS.gdf Created by Independent Third Party: Yes Back Next Contact Us:: 2601 Blair Some Road. Tallahassee EL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Flodda.:: Privacy Statement:: Accessibility Statement:: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Ronda Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emaits provided may be used for official communimtion with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick bere . Product Approval Accepts: ® ®®® Credit Card Safe https:llfloridabuilding.org/pripr_app dti.aspx?param=wGEVXQwtDgsiWEgpVGlupCVZKm22%2bM%2bN%2bs42kUginbFYby94WM7fBA%3d%3d Page 3 of 4 Florida Building Code Online . - 1/22/19, 12:20 PM o. MMra • • r 1 1 •'1 1 r.: SCIS Home I Log In I User Registration I Hot Topics I Submit Sumharge I Stats & Facts Publications I Contact Us I acts Site Map I Links I Search Florida ( d *�.ILApprovalProduct USER: Public User pr Product Approval Menu > Product or Application Search > Apoli®tion Lmt> Application Detail FL # FL11602-R7 RECEIVED Application Type Revision Code Version 2017 Application Status Approved JAN 3 0 2019 Comments ST. Lucie County, Perrnittir1® Archived 0 Product Manufacturer Owens Corning Roofing and Asphalt, LLC Address/Phone/Email One Owens Corning Parkway Toledo, OH 43645 (740) 321-6345 Greg.Keeler@owenscorning.com Authorized Signature Keeler Greg Gre g.Kee ler@owenscorn ing. co m Technical Representative Greg Keeler Address/Phone/Email 2790 Columbus Road Granville, OH 43023 (740) 321-6345 greg.keeler@owenscorning.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 12/31/2020 Validated By John W. Knezevich, PE (] Validation Checklist - Hardcopy Received Certificate of Independence FL11602 R7 COI 2018 01 COI NIEMINEN odf Referenced Standard and Year (of Standard) Standard YearASTM JLE ASTM D1970 2015 ASTM D226 (phF �I' 09 g/pr/pr_app dtl.aspx7param=wGEVXQwtDgsQFc5K%2fTrZeHYB7UCe5KMr5EmR4gtpLet7gKPIfTBaeQ%3d � Page 1 of 2 Florida Building Code Online 1/22/19, 12:20 PM Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBCApproval Date Approved Summary of Products ASTM D4798 FRSA/TRI April 2012 TAS 117(B) Method 1 Option D 08/16/2018 10/08/2018 08/23/2018 10/18/2018 2011 2012 1995 FL R i Model, Number or Name Description 11602.1 Titanium Roof Underlayments Synthetic sheet -type roof underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL11602 R7 II 2018 09 FINAL ER OWENS Approved for use outside HVHZ: Yes CORNING FL11602-R7.12df Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-45 Created by Independent Third Party: Yes Other: 1.) The design pressure noted herein pertains to use Evaluation Reports of a specific underlayment system beneath foam -on tile FL11602 R7 AE 2018 09 FINAL ER OWENS sytsems. Refer to ER Section 5.6.3 for details. 2.) Refer to ER CORNING FL11602-R7.odf Sections 5 and 6 for other Limits of Use. Created by Independent Third Party: Yes Back Nett Contact Us :: 2601 Blair Stone H d.Tallahassee R 32399 Phone: SSO-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are pudic records If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick h1e e,_. product Approval Accepts: ®®©RR® Credit Card Safe https://floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsQFc5K%2fTrZoHYB7UCe5KMr5EmR4gtpLet7gKPIfTBaOQ%3d%3d Page 2 of 2