Loading...
HomeMy WebLinkAboutPRODUCT REPORTINTEGRITYMETALS Compliant with Florida Building Code 2017 (6t1 ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant Active Quality Assurance Program Product: Min. 26GA 5V Crimp Roof Panel FBC Sec. 1507.4.2 Yield strength: 49ksi 24" Coverage (Max.) Vero Beach, FL 32960 772-284-5 SCANNED BY St. Lucie Countv Rib Height 3/8" Minimum 15/32" plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code.2017. %" penetration thru plywood supports 24" max. o.c. Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener (Method 1): #10 x 1-1/2" HiLo HWH fasteners w/ weather seal washer @ 16"O.C. at each seam and intermediate Rib. Fastener (Method 2): #10 x 1-1/2" HiLo HWH fasteners w/ weather seal washer @ 12"O.C. at each seam and intermediate Rib. Underlayment: To be compliant with FBC Sec. 1507, Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. Install Details: Table A Allowable Loads Method 1: Method 2: DESIGN PRESSURE* -63.5 PSF - 86 PSF SPACING 16" O.C. 12" O.C. Reference Data: Intertek Testing (TST-1527) REPORT # 14625.02-450-44 RO UL 580-06 o'Design Pressure safety margin of 2:1 Certificate of Independence: Locke Bowden, P.E. does not have, nor will acquire a financial interest in any company manufacturing or distributing products under this evaluation. Locke Bowden, P.E. is not owned, operated, or controlled by any company, manufacturer, or distributing products under this report. / `` D. Bolrryrr��'' l . No.49704 seal •• STATE OF ;�to .� O��Cn PCORI0A0G�``�.�. Integrity , -1als Min. 26GA 5V Crimp Roof ravel Installation Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6T" ed.. see Chart 1507.1.1 2. Minimum slope to be compliant with Florida Building Code 2017 6"' ed., and per with Manufacturers installation reference. 3. Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6" ed., Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report 4 3/8" / 7- PROFILE SCANNED BY St. Lucie County FASTENER PATTERN FIELD SPACING @ 16" O.C. PERIMETER SPACING @ 12" O.C. GULER O -=— —— - - - - - - - - - - - - - - —RIDGE L---- ---- —— — — — — — — Ia1 ---------------------'i I ZONE t -------------- t I =a HIP RODF ----------------; `i RIDGE a'— — — — — — — — ZONE i EAVE laT N =a