Loading...
HomeMy WebLinkAboutEVALUATION REPORTSCANNED MEMO I etc. BY [erWWW ofAuthorhadan 032455 St. Lucie County 353 Christian Street, Unit #13 Oxford, Cr 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT Polyglass USA, Inc. Evaluation Report P12060.02.09-R24 1111 West Newport Center Drive FLS2S9-R28 Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009 (954) 233-1230 Revision 24: 01/24/2018 SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Cade and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the & Edition (2017) Florida Building Code sections noted herein. DEscRnmON: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. coNmuED Compum E: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility lotation(s). NEMOIetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. AovERTISEMENT; The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. ' INsPEcnoN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for Inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. Prepared y. �u,�rrg"w�a.r Robert J.M. Nleminen, P.E. Florida Registration No. 59166, Florida DUI ANE1983 �(tta.....a.a . The fadm0e seal appearingwas authorized by Robert Nleminen, P.E. on 0IA4/2018. This does not some as an alectrus Ically signeddocument CERtIRCATION OF INDEPENDENCE: 1. NEMOletc. does not have, nor does it Intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMOI etc. Is not owned, operated or controlled by any company manufacturing or distributing products It evaluates. 3. Robert Nleminen, P.E. does not have nor will acquire, a financial Interest in any company manufacturing or distributing products for . which the evaluation reports are being Issued. 4. Robert Nleminen, P.E. does not have, nor will acquire, a financial interest in any other entity Involved in the approval process of the product. S. This Is a building code evaluation. Neither NEMOIetr- nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. M d W �i J .d N Tl r�iry grvrv�ry NNlo ova^oo'oT o.8o� 6 o$0�o800`a O R .n.pp�qeq�C O�C O VG m 4pp,yy4{y.CCyy}}'�� tp'aateh 29 ROaui .rif 'l�0�CNo000 �g .Q�igp9p. jG�QQ V yy�- �I$O y� Ili v� fli V7N N vhl vl exxd any l� l��{ryry ER E �jLL=Q�LL��� � m6 M16666 a664�66 n� K'1titiO <.E6�6d66� M W 004 �aad3T ah alai Si "fah "� m "d m "� ma�wa""a n n n n n n n a a n a a a n a n m a a a a p=35B36'�E��'�66L�3�'j6�6==6=6=6=C=33p 9pp 8,Qpp OI m m m" m m m m m m m A OI m m nan0pppnppp�nppp/^/m���m^n1a�o^p�pp^mnpc^^pola�olcc�op'�Q�p�a^ov��1(�l0000 �00000 099 2 Entity ERD (TST 6049) ERD (TST 6%9) ERD (rSr 6049) ERD M76049) ERD M 6049) ERD (TST 6049) ERD (TSr6049) ERD (TST 6049) ERD (rSr 6049) ERD (TST 6049) ERD (rST 6049) ERD(TSr 6049) ERD (TST 6049) ERD (TSr 6049) ERD (TST 6049) ERD tM 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TSr 6049) ERD (TSr 6049) ERD fFST6049) ERD (W 6049) ERD (TSr6049) ERD (TST6049) ERD (TSr 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ICC-ES (EVL 2396) Miami -Dade (CER 2592) PoWlass USA Polyglass USA Polyglass USA UL, U.C. (QUA96M Examination Physical Propertles Physical Properties Physical Properties Wind Uplift Physical Properties Wind Uplift Wind Uplift IMnd Uplift Wind Uplift Wind Uplift Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Wind Uplift Physical Properties Wind Uplift Physical Properties Physical Properties Physical Properties IBCCompliance HVHZ Compliance Manufacturing Affidavit P/LAffidavlt Materials Affidavit Quality control Reference P40390.08.12-1 P40390.08.12-2 C41420.09.12-3 P396=03.13 P45370.04.13 P1738.02.07-112 11757.04.01-1-R1 P41630.08.13 P3175LO5.03-RI PI178L11.03-RI P45270.05.14 6020.07.24.2 6020.09.14-2 6020.09.14-3 6020.09.14-4 6020.09.24-5 602D.09.14-6 P46520.10.14 P4329).10.14 PLYG-SC7550.03.15 P40390.04.15 P44360.10.14-R1 PLYG-SCBM.OS15-1 PLYG-SC8905.05.16-1 PLYG-5C8080.07.16 PLYG-SC22025.10.16 PLYGSC33040.12.16 PLYG-SC11900.03.17 PLYG-SC12115.08.17 ESR-1697 NOA34-D717.08 Products Current Mule -Hide Cross I% Polystick SA Compound Service Confirmation 4. PRoDUcr DERRIPnON: 41 - MectraiilrallyFas, ,'"e"drtJieleibymerits 4.2.1 Elastobase Is a fiberglass reinforced, SB5 modified bitumen base sheet. 4.1.2 Elastobase P is a polyester-relnforced, SOS modified bitumen base sheet. 4.1.3 Polyglass 62 Base is a fiberglass -reinforced, asphaltic base sheet 4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet ®MEMO etc. Date 08/06/2012 O8/07/2012 09/31/2012 03/04/2013 04/26/2013 04/29/2013 04/30/2013 08/06/2013 22/26/2013 11/26/2013 05/12/2014 09/DS/2014 09/08/2014 09/08/203A 09/09/2014 09/08/2024 09/08/2014 30/03/2014 10/17/2014 03/24/2015 04/03/2015 05/18/2015 05/20/2015 OS/17/2016 07/26/2016 10/12/2016 12/27/2016 03/20/2017 09/08/2017 11/01/2D14 01/22/2015 02/18/2009 03/01/2008 08/18/2011 Exp.10/05/2018 4.2.1 Polystick MrS or Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyolefinle film surface; meets FRSA/YRI April 2012. 4.2.2 Polystick IR-%e Is a nominal 60-mll thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.23 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets A5TM M70 and FRSAfM April 2012. MEMO ETC, LLC Evaluation Report P12060.02.09-1124 rerty79ta ojnuNodartbn l32455 6poly�ass Roof U Perlaymams• (, 954) 233-1230 Revision 24. M 24/2018 Page 3 of 74 ONEMOJetc. 4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface; meets FRSAfMI April 2022. 4.2.5 Polystick TU Max Is a nominal 60-mll thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. 4.2.6 PoWex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester. reinforced, APP modified bitumen cap sheets, meet FRSA/TRI April 2012. 4.2.7 Polystick Dual Pro'" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970. 4.2.8 Polystick Tile Pro'" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. 4.2.9 Polystick MU-X is a nominal 54-mil thick, dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D2970 (See Section 5.8). 4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Rooflng" (ASTM D6380, Gass M) in the Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRi April 2012 (04-12) beneath mechanically fastened or adhered the roof systems. 4.32 Elastoflex S6 G and Elastoflex S6 6 FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164. Elastoflex S6 6 and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) In the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. Elastoflex S6 G Is for use as an alternate to Hot Asphalt applied "Cap Sheet•' in the "Two Ply Systare from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an alternate to Hot Asphalt applied "Cap Sheet" In the 'Two Ply System' from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. 4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. Polyflex 6 is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Polynex G FR Is for use as an alternate to Heat Applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, Is/was used for permitting or design guidance unless retained spedficallyfor that purpose. 5.2 This Evaluation Report Is not for use in the HVHL 53 Fire Classification Is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product 5.4 Polyglass Roof Undedayments may be used with any prepared roof cover where the product Is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data forthe prepared roof covering. NEMO ETS 1LC. Ewluatlon Report P12060.02.09-1124 a4lm rfA"th"dmtian M455 6m EDITION(2017) FBC NON-HVHZEVAWATION F1.5259-1128 PolygiaZ Raof Underlaymems; (954) 233-1230 Revision 24: 01/24/2018 Page 4 of 14 oNenno j etc. 5.5 Allowable Roof Covers: Underlayment Asphalt Shingles Nalt-On Ilia Foam -on Toe metal W-dShakes Stshlreles slate Elastobase Yes Yes 1�5h�InZpfysVuor) Yes (B=Sh�ln2-plyv,�) Yes Yes Yes Etastobase P Yes Yes Yes Yes Yes yes Polyglass G2 Base No Ieam Yes Yes No No No Polygla5sAPP Base No Yes Yes No No No Polystfick MTS or MTS PLUS Yes Yes No Yes Yes Yes PolystickIR-)(e Yes No NO No Yes Yes — PolpdckTU P No Yes Yes (See S.5,1) No No No PoWck TU Plus Yes Yes Yes (SeeS.SI) Yes Yes Yes PolyseckTU Max No Yes Yes (SCeS5,I) Yes No No PGIVSUCkDUBIPM Yes No No Yes Yes Yes PolystickThe Pro Yes Yes Yes (See55.1) Yes Yes Yes POWI&MU-X Yes No No — Yes Yes yes Elastoflex SSG Yes Yes Yes (See 5.S.1) No yes Yes Elastoflex S6 G FR —TC;— Yes No No Yes Yes EiastonexrTu Yes yes Yes (SMS.S.1) No Yes Yes— PGWexG Yes Yes Yes (See 5.5.1) No Yes Yes PCIVf1exG FR Yes Yes No No Yes Yes PoWexSAP urSAP Fit Yes Yes (See55-1) Na Yes Yes Mule,HIde SA-APP rap Sheet crSA-APP Cap Sheet (FR) Yes Yes Yes (See 5.5.1) No Yes Yes 5.5.1 "Foam -On Tile" Is limited to use of the following Approved tile adhesives / underlayment combinations. pus JLGA;,4i�lMl lyNpewwYdl Florida Product Undedallments AdhesiveApproval CAP Foam Touch'n Seal Stormliond Roof FL14505 poWckTU Plus, PolystickTU Max Tile Adhesive DowTllelhond" FL22525 polysuckTu P, PaWckTU Plus, Polyflex SAP or Tile Pro Polystick TU P, PolystickTU Plus, PC[Vsflck TU Max, Polystick Tile Pro, JCP Adhesives Pclysetm AH-160 FL6332 Eiastaflex G TU, Ejastofiex S6 G, Polyflex G, Polyflex: SAP, PoWex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) Polystick TU P, PoWfick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives PolysetO R`rA-1 FL6276 Elastoflex G TU, Elastoflex 55 G, PoWex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SXAPP Cap Sheet (FRI Refer to Tile Manufacturers or Adhesive manufacturer's Florida ProductApprovo)for Overturning Momert Resl5tOnw Perf0munce NEMO ETC, LLQ Ewlu3UM RePort P12060.02.09-R24 CoWod. VfAdMr&otbn MARS BTM ODMON (20,7) Flic Nt)N4mz EuAwAnoN FL5259-R28 polygl= Roof Undedayments, (954) 233-1230 Rwislon 24:01/2412018 Page 3 of 14 ONEMOJetc. 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to; D New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D42 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (designed and installed to meetwind loads for project). Note. Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSS sheathing should be cleaned of all dirt and debris prior to application of Pawkk membranes. Elastaflex G TU, Elastoflex S6 G or Elastoflex s6 G FR In hot asphalt to: D ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torchapplied to: D ASTM D41 primed structural concrete. 5.6.2 Band -to -Insulation: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: D ASTM CIM, Type 11, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard; Dens Deck Prime; or SECUROCKGypsum-Fiber Roof Board. Elastoflex GTU, Elastoflex S6 G or Elastaflex 56 G FR In hot asphalt to: D Dens Deck Prime or SECUROCK Gypsum-Flber Roof Board. Polyflex G or Polyflex G FR torch -applied to: D ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, Insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For Installations under foam -on the systems, Insulation attachment shall be designed by a qualified design professional and Installed based an testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. 5.63 Bond to Mechanically Attached Base Laver. Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: D ASTM D226, Type I or It felt; Elastobase; Elastobase P or Mule -Hide Nall Base. Elastoflex G TU, Elastaflex 56 G or Elastoflex S6 G FR In hot asphalt to: D ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nall Base or Polyglass G2 Base. Polyflex G or Polyflex G FR Larch -applied to: D Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Palyglass APP Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For Installations under foam -an the systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC Section 15043.1. NEMOETC, LLC. Ewluaaoo Report P12060.02.09-R24 a9nJlrare ofANhorhaaantl324i5 6TM EUMON(2017) FBC NON4WHZEVALUATION Ft5259•R2B Polygiess Roof Onderiaymcnb; (954) 233-1Z30 Revision 24: a1/W2036 Page 6 of 14 ONEMOJetc. 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/rRI April 2012 (04-22) and are used in foam -On the applications. Maximum Design Pressure Is the result of testing for wind load resistance based On allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin Of safety per FBC 15G4.9 has already been applied). Refer to FRSA/rRI April 2012 (04- 12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure =-90osh Deck: MIn.15/324nch plywoodto meetpmject mquimmentstasaUsfactianufAuthority HavingJudsdiction. Primer. None Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP F% Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #2 Maximum Design Pressure --97.5pst Deck: Min. 25/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Poyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 3W ring shank nails through 32 ga., i-5/8' diameter tin caps spaced 12-inch a.c. #3 Maximum Design Pressure =-105 0A Deck: MIn.15/32-inch plywood to meet project requirements to satisfaction of Authority Having.lurlsdiction. Primer. we-3000 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polysack TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 135" ring shank nails through 32 ga., 1-5/8' diameter tin caps spaced 12-inch o.c. 44 Maximum Design Pressure =-135 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Havinglurisdiction. Pdmer. (Optional) PG100 or ASTM D41 Base Ply: (Optional) Polysdck MTS or Polystick MTS PLUS, self -adhered. Joints: MIn.4-Inch wide strips of Elastoflex SA-V over all plywood Joints Underlayment Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule-Hkde SA-APP Cap Sheet (FR), self -adhered. #5 Maximum Design Pressure --315osF. Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile P% Polygex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), seffadhered. #6 Maximum Design Pressure=-6225 Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer. PG100 or ASrM D41 Underlayment- Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torchapplied. #7 Maximum Design Pressure =-30.0 psP Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority HavinglurisdlcLion. Base Sheet: Elastobase or Mule -Hide Nail ease (poly -film top surface) Fasteners: 11 ga. x 1.25-Inch long x 1-inch head diameter round metal cap nails Spacing: 64nch o.c. at the }Inch wide side laps and 64nch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MIS PLUS, self -adhered. Underlayment Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP F% Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. NEMO ETC, LLC, Evaluation Report P12060.02A9-R24 Gfdgk m ClAudMmi a u mC324ST IP ERMON 12017) FBC NON-HVHZ EVALUATION FL52s9-R28 PnlyDass Root Underlaymeats, ISM) 233-IMB Revision 24: 0S/24/2018 Page7 of M ONEMOJetc. #8 Maximum Design Pressure=-37.5 osf*: Deck: Min.15/32inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet Elastobase or Mule -Hide Nail Base(poly-film top surface) Fasteners: 11 ga. x 1.254nch longx finch head diameter round metal rap nails Spacing: 6-Inch ac. at the }Inch wide side laps and 6-Inch o.c. at two (2) equally spaced staggered center rows Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlaymem: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflax SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #9 Maximum Design Pressure =-37.5 psi Deck: Min.19/32inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) or two (2) layers ASTM D226, Type ll felt Fasteners: 11ga. x L25-inch long 1-inch head diameter round metal cap nails Spacing: 6-Inch c.c. at the }Inch wide side laps and 12-Inch o.c. at two (2) equally spaced staggered center rows. Undedayment: Elastotlex G TU or Elastaflex S6 G, applied in full mopping of hot asphalt #10 Maximum Design Pressure --45 psf*; Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction. Base Sheet: One (1) IayerASTM D226, Type II felt Fasteners: 11 ge.x L25-Inchx3/8-inch head diameter annular ring shank roofing nails at 2-5/9-hrch diameter tin caps Spacing: 4-Inch o.c. at the 2-inch wide side laps and 4-Inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underiaymem only) Polystick MTS or Polystick MTS PLUS, selfadhered. Underlaymem: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU, applied In full mopping of hot asphalt. #11 Maximum Design Pressure =-45 psf°: Deck: Min:L9/32-Inch plywood to meet project requirements to satisfaction of Authority Having Judsdiction.. Base Sheet: Two (2) layers ASTM D226, Type II felt Fasteners: 11 ge.x 1.25-Inch long 3/84nch head diameter annular ring shank roofing nails at 2-5/8-Inch diameter tin caps Spacing: 9-inch c.c. at the 24nch wide side laps and 94nch o.c at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self- adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered. Underiaymem: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP Fit, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), selfadhered or Elastoflex G TU or Elastaflex S6 G, applied In full mopping of hot asphalt #12 Maximum Design Pressure =-45 psi: Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torchapplied cap or poly -film surface fortorch-applied cap) Fasteners: Simplex MA70C Cap Fasteners Spacing: 9-inch o.c. at the 24nch wide side laps and 1.8-Inch o.a at two (2) equally spaced staggered carrier rows. Underlayment Elastaflex G TU or Elastaflex S6 G, applied In full mopping of hot asphalt or Pclyfiex G, torch -applied. #13 Maximum Design Pressure=-52.5 psE Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Smplat MAXX Cap Fasteners Spacing: 9-inch or- at the 2-Inch wide side laps and 12-Inch O.C. at two (2) equally spaced staggered center rows. Undedayment• Elastaflex G TU or Elastaflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #24 Maximum Design Pressure =-525 psi: Deck Min.15%324nch plywood to meet project requirementsto satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nall Base(poly-film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-Inch o.c at the 34nch wide side laps and 6-inch ox at four(4) equally spaced staggered center rows Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlaymem: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP Fit, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. NEMO ETC, U.C. Evaluation Report P1206002.09-R24 Oe Wote ofAUftdWtion 032455 6TM EDITION (2017)FBC NON-HVN2 EVALUATION FL525.9-RZB Polygki Roof Underlaymems; (9S4) 733.1230 RYisTan 24:0112412018 Page 8 of 14 00NEMICIletc. #15 Maximum Design Pressure =-525 0511 Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction. Base Sheet: Elastobase(sanded top surface for hot -asphalt or tomhapplied cap or poly -film surface for tench -applied Cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c at the 3-inch wide side laps and &inch o.c at four 14) equally spaced staggered center rows. Underlayment Elastoflex G TU or Elastaflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #26 Maximum Design Pressure =-60 Dsf: Deck: Min. 19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot -asphalt or torch -applied cap or poly -film surface fortorch-applied cap) Fasteners 11 ga.x125-Inch longx 3/84nch head diameter annular ring shank roofing nails at 1-5/8-Inch diametertln caps Spacing: 84nch o.c. at the 4-Inch wide side laps and 8-Inch o.c at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU a Elastoflex 56 G, appiled In full mopping of hat asphalt or Polyflex G, torch -applied. #17 Maximum Design Pressure =-60 psf: Deck Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having lurlst iction. Base Sheet Elastobase(sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for tumliapplied cap) Fasteners: OMG #12 Standard RoDfgdp with OMG Flat Bottom Metal Plates Spacing. 12-inch a.c. atthe 4-Inch wide side laps and 124nch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastaflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #19 Maximum Design Pressure=-67.5 psf: Deck Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet Polyglass 62 Base or Polyglass APP Base (requires use of torch -applied underayment) Fasteners: 12 ga. x 1.25•inch long 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-Inch me at the 4-Inch wide side laps and &Inch ac at four (4) equally spaced staggered center rows. Underlayment: Elastotex G TU or Elastoflex 56 G, applied In full mopping of hot asphalt or torch -applied or Polyflex G, torch - applied. #19 Maximum Design Pressure=-75 psf. Deck: Min.15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of taro ipplled undMayment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Fiat Bottom Plates (AccuTrac). Trufast HD with Trufast 34ndh Insulation Plates or Simplex MAxX Cap Fasteners Spacing: 10dnch o.c. atthe 4-Inch wide side laps and 1G4nch ac at three (3) equally spaced staggered center rows. Underlayment Elastoflex G TU or Mastofim 56 G, applied in fug mopping of hot asphalt or torch -applied or Polyflex G, torch - applied. #20 Maximum Design Pressure =-900sf: Deck: Min. IS/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet Elastobase(sanded top surface for hot -asphalt or torch-appiled cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-fnch o.c atthe 2-Inchwide side laps and &-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastaflex G TU or Elastoflex S6 G, applied in full mapping of hot asphalt or Polyflex G, torch -applied. #21 Maximum Design Pressure =-90 osF. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. BaseSheet: Elastobase(sanded top surface for hot -asphalt or torch -applied rap or potµfilm surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3' Round Metal Plates or CMG Flat Bottom Metal Plates Sparing: &-inch o.c at the 4-Inch wide side laps and &-Inch o.c at three (3) equally spaced staggered center rows. Underlayment Elastoflex G TU or Elastaflex S6 G, applied In full mopping of hot asphalt or Patyflex G, torch -applied. #22 Maximum Design Pressure =.90 osh Deck Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast #12 DP or Trrcast4114 HD with Trufast 3' Metal Insulation Plates Spacing: 6-Inch o.c at the 44nch wide side laps and &•inch am at three (3) equally spaced staggered center rows. Underlayment; Elastoflex G TU or Elastaflex S6 G, applied In full mopping of hot asphalt NEMO ETC LLC Evaluation Report P32060.02.09-R24 rera5coftQFAutlndmtim 032455 eEDITION 12017) FBC NON4WKEVALUATION FL5259-1128 Polyglass Roof Underlayments, (954) 233,1230 Revldon 2,4:01/24/2018 Page 9 of 14 ONEMOletc. #23 Maximum Design Pressure = -90 osi Deck: Min. 25/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet. Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment) Fasteners: Dekfast #14 with Dekfast Her plates, OMG #14 HD with OMG 3' Galvalume Steel Plates, CMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-Inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 94nch o.c. at the 4-Inch wide side laps and 9-Inch o.c. at four (4) equally spaced staggered center rows. Undedaymem: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch- applied or Polyflex G, torch - applied. #24 Maximum Design Pressure = -97.S Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners 11 ga.x L25-Inch x 3/8-Inch head diameter annular ring shank roafing nails at 1-5/8-Inch diameter tin caps Spacing: 4-Inch o.c at the 4-Inch wide side laps and flinch o.c, at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered Undedayment: Polystick TU P, PolystickTU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #25 Maximum Design Pressure =-105 A Deck: Min.15/32Nnch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface fortorrh-applied cep) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-Inch o.c at the 24nch wide side laps and 6-inch mc. at three (3) equally spared staggered center rows. Underayment: Elastoflex G TU or Elastoflex SS G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #26 Maximum Design Pressure --112.S P Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga-x 1.25-Inch x3194nch head diameter annular ring shank roofing nails at l-S/94nch diametertinraps Spacing: 6-Inch o.c at the 4-inch wide side laps and 6-inth o.c at four (4) equally spaced staggered center rows. Primer. PG1C0 or ASTM D41 primer at all tin -caps Base Ply: Polyetick MTS or Polystick MTS PLUS, self -adhered Underlayment. Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (Fit), self -adhered. #27 Maximum Design Pressure=-120 osf: Dacia Min.15/32-Inch plywood to meet project requirementsto satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surfacefor hot -asphalt or torch -applied cap or poly -film surface for torch-applled cap) Fasteners: CMG #12 Standard Roofgdp or OMG #14 Heavy Duty with OMG 3' Round Metal Plates or OMG Flat Bottom Metal Plates Spacing. 6-Inch o.c. atthe 4-Inch wide side laps and 64nch o.c. atflve (5) equally spaced staggered center rows. Underayment: Elastoflex G TU or Elastoflex 56 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied. #28 Maximum Design Pressure=-120ttsf: Deck: Min.25/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast#12 OP orTrubst#14 HD with Trufast 3" Metal Insulation Plates Spacing. 6-Inch o.c at the 4-Inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. 5.6.4.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on file systems carry a Maximum Design Pressure of -45 psf. NEMO ETC, LLC. Evaluation Report P32060.02119424 feffl& eo/AuMadmnon 03240 eEDMON(2027) FBC NON-HVHZ EVALUATION FL5259-07a Polyglass Roof Undarlayments; (954) 233-IZM Revision 24:01/24/2018 Page 10 of 14 r ONEMOjetc. 5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-22), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RA5117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Elastabase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days after Installation. Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after Installation. Polystick M1[5, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for longer than 180-days after Installation. Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering Is to be adhesive -set tile, in which case the maximum exposure Is 30 days. Elastoflex S6 G or Elastoflex 56 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the prepared roof covering Is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure Is 190 days. 5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth In Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance. 5.9 Tile Slippage Limitations (FRSA/TRI Avril 2022 (04-121), When loading roof tiles on the underlayment In direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. ibnsrnifDlfeFcoiix.X�irr'InsTA g7roW- .`: •i', ,:�:; %-. Underlayment Tile Profile Staging Method Maximum Sloper Elastoflex G TU Rat 10-tile stark 7:12 Lugged 8-tile stack (6 over 2) 6:12 Elastoflex SSG or S6 G FR Flator Lugged 6-tile stack (4 over 2) 4:12 Polystick MTS or MTS PLUS Flat 6-tile stack (4 over 2) 5:12 Lugged 6-tile stack (4 over 2) 4:12 PolystickTilePm Rat or Lugged 6-tile stack (4 over 2) 7:12 PolystickTU Max Flat 6-tile stack (4 over 2) or 20-tile stark 7:12 Lugged 6-tilestack(4over2) 7:22 Lugged 10-tile stack 6:12 PolystTckTUP Flat 6-tile stack (4 over 2) 6:22 Lugged 6-tile stack (4 over 2) 4:12 PolystickTU Plus fl at or Lugged 5-tile stack (4 over 2) 7:12 Flator Lugged 10-tile stack 6:22 Polyflex G or G FR Rat or Lugged 6-tile stack (4 over 2) 4:12 Polyflex SA P or SA P FR Rat or Lugged 6-tile stack (4 war 2) 1 4:12 NEMO ETC, LLC. Evaluatlon Repoft P12060.02.09-R24 Qu*mle.fAuNa(e 40M455 dm EPMON(2017) FBC NON+NHZEVALUATION FL9299-R28 Poiyglass Roof Underlayments, (954) 233.12a0 Revlsion 24: OV2412MB Page 11 of I4 ONEMOletc. 6. IrwAumn=: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Umkatlons set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). Shall be installed in compliance with the codified requirements for ASTM D226, Type II underiayment in FBC Table 1507.L3 for the type of prepared roof covering to be installed. Elastobase, Elastobase P or Mule -Hide Nag Base may be covered with a layer of Poiystick, Polyflex SAP, Polyflex SA P FR, Mule -Hide SAAPP Cap Sheet or SAAPP Cap Sheet (FR), self -adhered, Elastoflax G TU, Elastofiex S6 G or Elastoflex S5 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top-layerunderlayment, as set forth in Table 1, 6.3.2 Tile Applications: Elastobase, Elastobase P or Mule4gde Nall Base are limited to use as a mechanically attached base sheet in the `Two Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with FRSA/TRI April 2012 (04-12) Installation Manual. 6.4i Po�stit:NEST_IVRSR[t1,511tt7(€3i1:PsTFJPI4¢r?UIVIdxi:P!S?►ATIELdrIviU>Cot.FOIYRek.SAp,PofyfleiC1CPFRt Mule-Mde'SAcAp�!F.�p'Syfe�tor`Mute�UdeSglk P 6.4.1 Shall be Installed In compliance with the codified requirements for ASTM D1970 (except PolysdckTU P) underlayment in FBC Table 1SO7.L1 for the type of prepared roof covering to be installed. 6.4.2 Direct -to -Deck with Mechanically Fastened Roof Covers: All self -adhering materials, with the exceptlon of PolystIc k TU Plus, Palyflex SAP or SAP FR and Mule -Hide SA APP Cap Sheet or SAAAPP Cap Sheet (FR) should be back -nailed in selvage edge seam In accordance with Polyglass / Mule - Hide back nailing guidelines. Nails shall be corrosion resnstant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c Polystick TU Plus should be back - nailed using the above noted fasteners and spacing, in area marked "nail area, area pare clever" on the face of membrane. The head lap membrane Is to cover the area being back -nailed. All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand rollerto ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). LM View of OwhpSeam of oral Pmaad nla Pro All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus SO Premium Modified Wet/Drytement or Polyglass PGSBO Modified Cement applied in between the application of the lap. PolystickTU Pius, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details NEMO ETC, r Evaluation Repan PIM50.0209-I124 O°v pa VfAatha aamne'LCC 6w EDmON (20171 FOC 140144nuREVALUATION FL5759•R78 PoWW= Roof Underlayments, (9541233-IM Revision 24: "4/2M8 Page 12 of 14 ONEMOjetc. Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass P6500 Modified Cement to the area In need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be Installed In a water shedding manner. All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 404b weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min.28111 roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 Tile Applications (not allowed forPolvstick Dual P%IR-Xe or PalwUrk Mfl-X): Reference Is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the Instructions noted above as a guideline. For mechanically fastened file roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 201Z (04-12). Table L For adhesive -set tile applications, refer to Section 5.6A herein. 6.4.4 Two (2) Ply Underlayment Systems: Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Tile Pro, MU-x or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This Is not a requirement, but is allowable if a 2-ply underlayment system Is desired. Polystick NITS or MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use under foam -on tile systems. Limits of use are those associated with the top -layer material. This Is not a requirement, but Is allowable if a 2-olv underlayment system Is desired. 6.5.1 lElastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed In compliance with current Polyglass published Installation requirements. For use In tile applications: ✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D5380, Class M) in the "Single Ply System" from FRSA/TRJ April 2012 (04-22) beneath mechanically fastened tile roof systems or the Hot Asphalt applied 'Cap Sheet" in the `Two Ply System' from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System' from FRSA/TRI April 2022 (04-12) beneath mechanically fastened the roof systems or the Hot Asphalt applied "Cap Sheet' In the'Two Ply System' from FR5A/TRI April 2012 (04-12) beneath mechanically fastened or adhered the roof systems. ✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M) in the "Single Ply System' from FRSA/TRI April 2012 (04-22) beneath mechanically fastened tile roof systems or the Hot Asphalt applied 'Cap Sheet" in the'Two Ply System' from FRSA/TRI April 2012 (04-22) beneath mechanically fastened tile roof systems. 6S.2 For hot -asphalt -applications, Elastoflex G TU, MastoftexS6 G or Elastotlex S6 G FR shall be fully asphalt -applied to the substrates noted In Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-Inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully adhered In a complete mopping of hot asphalt with asphalt extending approximately 3/8-Inch beyond the lap edge. 6.6.1 Polyflex G or Polyfiex G FR shall be installed In compliance with current Polyglass punllsne0 lnsrallauon regwremenrs. For use in tile applications: ✓ Polyflex G Is for use as an alternate to the Heat Applied'Cap Sheet" In the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered the roof systems (Base Sheet Limited per5.63). ✓ Polyflex G FR is for use as an alternate to the Heat Applied 'Cap Sheet" In the 'Two Ply System' from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.63). NEMO ETC, ILG Ewluatlon Report P12060.02M-R24 ¢RpC;ft,fAuMmlmtmn l3M4SS en'EDMON(Z017) FBC NON-HVH2 EVALUATION F`2594tza Polyglom Roof Underlayruents, ism) 233-MO Rmldcn 24: 01/M12018 Page 23 of 14 ONEMO etc. 6.6.2 Polyflex 6 or Polyflex 6 FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-Inch and end -laps minimum 6-Inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 6.7 Tile Stan: 6.7.1 Tile shall be loaded and staged In a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Polyglass published requirements for tile staging. 6.7.2 Battens and/or Counter -battens, as required by the file manufacturer and FRSA/TRI April 2D12 (04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail- boards, to prevent the sliding and/or damage to the undedayment during the loading process. 6.7.3 Polyglass specifies the minimum cure time after Installation of self -adhering membranes and before loading of roofing tiles Is forty-eight (48) hours. 7. BUILDING PERMIT REQUIREMENTS' As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product S. MANUFACTURING PLAN75: Contact the noted QA agency for Information on product locations covered for F.A-C. 61620-3 QA requirements. The following plants have qualified products under their respective physical properties specifications. Femley, NV, Hazleton, PA & Winter Haven FL ASTM D1970 PolysUck MU-X Hazleton, PA M-D 13-0004 Elastoflex G TU Hazleton, PA & Winter Haven, FL ASTM 01970 Polysdck IR-Xe . ASTM D2970 & FRSA/fRl April 2012 PalVstick TU Plus ASTM D1970 & FRSA MIApril 2012 Polystick TU Max Tuscaloosa, AL ASTM D46M, Type II PolVgtaw G2 Base Winter Haven, FL ASTM D226 (p ical$) Elastobase, Elastobase P ASTM D6SC9 APP Base FRSA/IRI April 2012 MTS, POlystick MTS PLUS - FRSAj(RI April 2012 TU P FRSArrlU ri12012 AP, Pol ex SA P FR ASTM D1970 Dual Pro AftlysUckTilePro ASTM D3970 & FRSA/rRl April 201 Tile ProASTM D6164 S6, Elastoflex S6 G FR ASTM D6222 Po ex G FR 9. QUALITY ASSURANCE ENTITY. Ut, LLC—QUA9625; (314) 578-3406; kchancellor@us.ul.com. -END OF EVALUATION REPORT - NEMo ETC LLC Evaluation Report P12060.02-09-R24 CuWkuteofAuthwkatw#M455 6EDMON(2017) FBC NON-HWZEVALUAMON FL5259-RZB Polyg = Roof Underlaymmrtsl (954) Z33=0 Revision 24: 01/24/2016 Page 14 of 14