HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEIC(_C a 0
SJ�J7 AI
Planning& Development Services Department <44" p90Ad o,9
Building & Code Regulations Division C641, t
2300 Virginia Avenue, Fort Pierce, FL 34982—(772) 462-1SS3 �P
Certification for Design Load Compliance
Project Name: Sands I Condominium - Building 1 Unit 203 Sliding Glass Door Replacement
Project Address: 3206 South Lakeview Circle, Fort Pierce, Florida 34949
Permit
Type: R-2 Construction Type: VB
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family) SCANNED
o Residential Addition BY
o Any accessory structure requiring a building permit St. Lucie County
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida FBCEB Code Sixth Edition with 2017 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category:I X II _III_IV Exposure Category:_BC X D
4. Design Wind Velocity 161 mph ASD X LRFD End Zone Width: 5 ft
S. Mean Roof Height 25 ft Roof Pitch: 5 :12 Parapet: ft
6. Components & Cladding Design Pressures -Used: (PSF)
Zone 1: Zone 2: Zone 3: Zone 4: Zone S: +40/-51 Garage: N/A
7. Design Loads: Floor: 40 PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: 60 PSF
Dock: PSF Deck: PSF Stairs: 100 PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? —Yes X Not Applicable Explain Why Not:
No work to be done on the existing shearwalls; no changes to shearwalls.
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? Yes
that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
\\\\\II I I I Id Olt the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
\\\�QQO� f�E ¢Gr�s'd�certify that structural elements depicted on these plans provide adequate resistance to the design
`' \� or
't No. 10
=v:
10 SrAT
i fn .c OF
� ts'• �o
0111 I4I 11l-
Rodolfo Villamizar, P.E.
Print Name
MBV Engineering, Inc.
FL P.E.#61000 & SI#7021620
Cent # & Co. Cert Auth.
1835 20th Street, Vero Beach, FL 32960
Company Name & Address
Revised 12/07/2018
FS, LE