HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEIC(_C a 0 SJ�J7 AI Planning& Development Services Department <44" p90Ad o,9 Building & Code Regulations Division C641, t 2300 Virginia Avenue, Fort Pierce, FL 34982—(772) 462-1SS3 �P Certification for Design Load Compliance Project Name: Sands I Condominium - Building 1 Unit 203 Sliding Glass Door Replacement Project Address: 3206 South Lakeview Circle, Fort Pierce, Florida 34949 Permit Type: R-2 Construction Type: VB INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) SCANNED o Residential Addition BY o Any accessory structure requiring a building permit St. Lucie County o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida FBCEB Code Sixth Edition with 2017 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category:I X II _III_IV Exposure Category:_BC X D 4. Design Wind Velocity 161 mph ASD X LRFD End Zone Width: 5 ft S. Mean Roof Height 25 ft Roof Pitch: 5 :12 Parapet: ft 6. Components & Cladding Design Pressures -Used: (PSF) Zone 1: Zone 2: Zone 3: Zone 4: Zone S: +40/-51 Garage: N/A 7. Design Loads: Floor: 40 PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: 60 PSF Dock: PSF Deck: PSF Stairs: 100 PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? —Yes X Not Applicable Explain Why Not: No work to be done on the existing shearwalls; no changes to shearwalls. 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? Yes that, to the best of my knowledge and belief, the attached plans & specifications have been designed to \\\\\II I I I Id Olt the applicable structural portions of the building codes currently adopted and enforced by St. Lucie \\\�QQO� f�E ¢Gr�s'd�certify that structural elements depicted on these plans provide adequate resistance to the design `' \� or 't No. 10 =v: 10 SrAT i fn .c OF � ts'• �o 0111 I4I 11l- Rodolfo Villamizar, P.E. Print Name MBV Engineering, Inc. FL P.E.#61000 & SI#7021620 Cent # & Co. Cert Auth. 1835 20th Street, Vero Beach, FL 32960 Company Name & Address Revised 12/07/2018 FS, LE