HomeMy WebLinkAboutSTRUCTURAL EVALUATIONRECEIVED
2 7 2010
/90/- 05Y Permltting Department
St. Lucle County
AVIERICAN TOWER•
CORPORATION
Eng. Number OAA743318_C2_02
December 112018
Page 1 of 2
Structural Evaluation
ATC Site Number & Name
417613, Ankona FL, FL
Carrier Site Number & Name
10126629, Indian River Estates
Site Location
6375-Federal Highway
Port St. Lucie, FL 34952-9005, St Lucie County
27.34876666 N / 80.32691666 W
Tower Description
150 ft Monopole
Basic Wind Speed
Code
124 mph (3-Second Gust, Va d) / 159 mph (3-Second Gust, VuK)
ANSI/TIA-222-G/ 2015 IBC/ 6" Edition, 2017 Florida Building Code
Existing and Reserved Equipment
Elevation' (ft)
City
Antenna
MountType
Lines
Garner
Mount
RAID
150.0
151.0
"
6
,' Ericsson Radio 2212 B13/B5
Platform w/ Handrails
(12)15/8" Coax
(2)15/8" Hybriflex
Verizon
. 3
Ericsson RRUS-32
.1
:.: Raycap RCMDC-1127-1148
3.
- CSS X7-665-4
•-6
JMAWirelessX7CQAP-665-VR0
1
VZW Unused Reserve: 18,143sq in
134.0
136.0
1. �
Raycap ASU9338T1P01-
T_Arm
"
(12)15/ " HybridoMetro
(12)15/8 Coax
PCS
"]34A
3.
Nokia FRIG w/ Solar Shield
'6
Nokia FXFB _
]33.0
3
60" x 12" Panel
-"3
52" x 14"Panel
120.0
120.0
6
Andrew ETD819G-12UB
Low Profile Platform
(2) 0.78" 8 AWG 6
(12)15/8" Coax
(1) 3/8" RET Control
Cable
AT&T Mobility
6
RFS FDGW5504/3C-3
1
Raycap DC6-48-60-18-8F
Equipment to be Removed
Elevatiod (ft)
City
Antenna
MouMType
Lines
Garner
Mount
RAD
"
120.0
-
120.0
3
Kathrein 80010764"
_
-
(1) 0.35" Fiber
AT&T Mobility
4
Kathrein 742-265
2
Kathrein 80010122
6
Ericsson RRUS it (Band 12) (55 Ib)
SCANNED
BY
St. Lucie County
ATC Tower Services, Inc. - 3500 Regency Parkway, Suite 100 - Cary, NC 27518—919468-0111Office -919.466.5414 Fax- www.annericantoweLC0r0
A
AMERICAN TOWER
'CON P O RAT 10H
Proposed Equipment
Eng. Number 0AA743318_C2_02
December 112018
Page 2 of 2
Elevation"(fit)
4ty
Antenna
Mount Type
Lines
Cartier
.Mount
I RAD
-
120.0
120.0
3
Ericsson RRUS 8843 B2, B66A
-
Low Profile Platform
-
(4) 0.78" 8 AWG 6
(3) 0.39"fiber Trunk
AT&T Mobility
3..
Ericsson Radio 4415 B30
3:.
Ericsson RRU54449B5,912
2
Raycap DC6-08-60-18-8C -EV
6
Kathrein800-10864K
3
Kathrein 800-10964K .
'Mount elevation is defined as height above bottom of steel structure to bottom of mount, RAD elevation is defined as center of antenna
above grade level (AGL).
Install proposed coax inside of the pole shaft.
-
The existing and proposed loads listed in the tables above are compared to the towers current design capacity
or previous structural analysis. The tower should be re-evaluated as future loads are added or if actual loads are
found different from those listed in the tables. The subject tower and foundation are adequate to support the
above stated loads in conformance with specified requirements. -
ZH/ANG
No. 77250
f.
STATE OF�Id
Bryan Lanier, PE Thiskou., thadheen decunuu.4
ATC Tower Seavices Inc, s�nedanoseakdhv a yan wkenev,P6 .
m thedote erdJ"rtlme stmq sTo,Re
3600ResencyPaAcway, uilngadlgltahcvatwe.PrIMW6pee
Suite 100 ,atk davamentur .a.m dead
Ca!Y,NC 27518ne4andseateAand me s;Ennanlie
m�rxwnn.eaR,Ny ekiteRNt
FL ENG: NO. 77268 . wiP .
Bryan Lanier
Dec 12 2018 4:37 PM
COSIon
011
ATCTower Services, Inc. - 3500 Regency Parkway, Suite 100 -Cary, NC 27518-919468-0112 Office- 919.466.5414 Fax- vnvw.americantower.com