DESIGN PRESSURE CALCULATIONS
ALL AMERICAN SHUTTERS & GLASS (561) 712.9882 • www_allamerlcanshutiers.com SCANNED BY St. Lucie Countv Property Information Building Information Owner: PONESSE, V1T0 Wind Zone: 170 MPH. Address: 3000 HWY AlA Exposure Category: D APT 5A Minimum Building Dimension: 160 ft. FORT PIERCE, FL 34949 Mean Roof Height: 112 ft. Risk Category: ]II 11 Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psi) Max Negative Pressure (psf) 1 Int 80 101.75 48 48.1 -56.0 2 Int 48 48.1 -56.0 3 Int 75 102 48 48.4 -56.2 4 Int 48 48.4 -56.2 5 Int 760 102 48 38.5 -48.5 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads -Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1