HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSSCANNED ALL AMERICAN
BY SHUTTERS & GLASS
St. Lucie County1638 Donna Road, West Palm Beach, FL
nz-voaz • www.auumencansnuuets.cum
Information
Owner: HAGER, LEE
Address: 3000 N HIGHWAY AIA
APT 8A
FORT PIERCE, FL 34949
Information
Wind Zone:
170 MPH.
Exposure Category:
D
Minimum Building Dimension:
160 ft.
Mean Roof Height:
112 ft.
Risk Category:
HI
Design Pressure Calculations
Opening
Number
Location
Zone
Device
Width (in)
Device
Height (in)
Device
Elevation (ft)
Max Positive Max Negative
Pressure (psf) Pressure (psf)
1
Int
80 101.50 72
51.0
-56.0
2
Int
72
51.0
-56.0
3
Int
75 101.75 72
51.2
-56.2
4
Int
72
51.2
-56.2
5
Int
760 101.75 72
40.6
48.5
Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 61h Edition (2017) Florida Building Code.