Loading...
HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSSCANNED ALL AMERICAN BY SHUTTERS & GLASS St. Lucie County1638 Donna Road, West Palm Beach, FL nz-voaz • www.auumencansnuuets.cum Information Owner: HAGER, LEE Address: 3000 N HIGHWAY AIA APT 8A FORT PIERCE, FL 34949 Information Wind Zone: 170 MPH. Exposure Category: D Minimum Building Dimension: 160 ft. Mean Roof Height: 112 ft. Risk Category: HI Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Max Negative Pressure (psf) Pressure (psf) 1 Int 80 101.50 72 51.0 -56.0 2 Int 72 51.0 -56.0 3 Int 75 101.75 72 51.2 -56.2 4 Int 72 51.2 -56.2 5 Int 760 101.75 72 40.6 48.5 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 61h Edition (2017) Florida Building Code. Page 1 of 1