HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONS6CANNED
BY
!.tide County
LA
1638 Donna Road, West Palm Beach, FL 33409
(561) 712.9882 • ►w w.allamerleanshutiers_com
Property Information
Building
Information
Owner: FRANKS, MARK
Wind Zone:
170 MPH.
Address: 3000 N HIGHWAY AlA
Exposure Category:
D
APT 3C
Minimum Building Dimension: 160 ft.
FT PIERCE, FL 34949
Mean Roof Height:
112 ft.
it
Risk Category:
III
Design Pressure Calculations
Opening
Number
Location
Zone
Device
Width (in)
Device
Height (in)
Device
Elevation (ft)
Max Positive]
Pressure (pst)
F—m—ax Negative
Pressure (psi)
1
Int
460 101.50 30
36.3
-48.6
2
Int
30
36.3
-48.6
Prepared in accordwce with: ASCE 7-10, Chapter 30. Wind Loads -Components and Cladding. 6th Edition (2017) Florida Building Code.
Page 1 of 1