HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEr -( —0( 0
Planning & Development Services Department
Building & Code Regulations Division RECEIVED
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 FEB 0 7 1019
Certification for Design Load Compliance PerSt. Lucle county Department
Project Name: New Windows & Sliding Glass Door installs
Project Address: 9950 S. Ocean Dr. Jensen Beach FL 34957; Unit #1401
Permit
Type: Residence Construction Type: IIB
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition SCANNED
o Any accessory structure requiring a building permit By
o Any non-residential structure. St. Lucie County
' Note: Form not required for interior renovations provided that no exterior structural elements' are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Code Sixth Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III_IV ExposureCategory:BC X D
4. Design Wind Velocity 170 mph n/a ASD We LRFD End Zone Width: 5.5 ft
5. Mean Roof Height 140 ft Roof Pitch: 'Flat :12 Parapet: n/a ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: n/a one 2: n/a Zone 3: n/a Zone 4: +61.1/-69.7 Zone 5:'67.4/-82.5 Garage: n/a
7. Design Loads: Floor: n/a PSF Roof/Dead: n/a PSF Roof/Live: n/a Balcony: n/a PSF
Dock: n/a PSF Deck: n/a PSF Stairs: n/a PSF Fence: n/a PSF Railings: n/a PSF
B. Were Shear Walls Considered For Structure? Yes n/a Not Applicable Explain Why Not:
nDD WeWbVditg.JuetwldC agder being Dben,;Wout
9. Is A Continuous Load Path Provided? —Yes n/a Not Applicable Explain Why Not:
wmenwmwiare..msewmonaema Dare mwud •a
10. Design Soil Bearing Pressure: n/a P5F Soil Test Reports Submitted? ,,
DESIGN PROFESSIONAL CERTIFICATION STATEMENT: NQ�t , `T f 71/e NUM W (7lG�puY �! U �i�Gt� n r,,�
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been des�efCo 'S_ `A III
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie 20Id.0 4'
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Sign re, Date, and Seal
Revised 12/07/2018
Raymond Chladny
Print Name Cert # & Co. Cart Auth.
Advanced Architecture & Planning
4929 S. Indian River Drive, Ft. Pierce, FL 34982
Company Name & Address
CONTRACTOR COPY