HomeMy WebLinkAboutEVALUATION REPORTJAN 31 7019 S-r. Lucie EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION `26 GA. 5V-CRIMP PANEL' FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVAL - FL 14645.2-R3 ROOFING METAL ROOFING SSgNN� a St LuciecoU1761 Prepared For: Metal Sales Manufacturing Corporation 545 South 311 Street, Suite 200 Louisville, KY 40202 Telephone: (502) 85S 4300 Fax: (502)855-4200 Prepared By: Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (918) 493-3568 This report consists of Evaluation Report (3 Pages including cover) File Copy Installation Details (1 Page) %111111111 Report No. C2182-2 Date: 9.9.17 `,%% SOCKgG/ti,�i�. %�Q.,-"GENg' No 62240 r FL 14645.2-R3 C2182-2 9.9.17 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: 5V-Crimp Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 19/32" plywood or min. %" thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017. Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c. (Minimum) in the field and edges. Designed as per FBC 2017. Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1 Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 84.5 psf @ fastener spacing of 24" o.c. (Factor of Safety = 2) 131.3 psf @ fastener spacing of 18" o.c. 149.6 psf @ fastener spacing of 12" o.c. Fastener Pattern: Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". At panel ends 6 fasteners per panel width. (4 located adjacent to ribs and 2 between ribs) At intermediate 4 fasteners per panel width. (4 located adjacent to ribs) Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current FL 14645.2-R3 C2182-2 9.9.17 Page 3 of 3 approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc Project No. T235-07, Reporting Date 7/12/07 Project No. T172-08, Reporting Date 4/29/08 SV-CRIMP SV-CRIMP SEE DETAIL 1 PANEL FASTENER SPACING PER ALLOWABLE PRESSURE TABLE ON THIS SHEET. L UNDERW MENT SHALL BE INSTALLED I / \ `MINIMUM ATTACHMENT: AS PER MANUFACTURER'S INSTALLATION L 8d x 2.5" LONG RING SHANK NAIL MIN, AT WOOD RAFTER/JOIST/ GUIDELINES OR #8 x 2" LONG WOOD SCREWS TRUSS AT MAX. 24" O.C. SPACED O.C. IN THE FIELD & AT PLYWOOD EDGES EASSENER PATTERN AT INTERMEDIATE LOCATIONS SEE DETAIL 1 24" 7 L UNDER YYMENT SHALL BE INSTALLED / \I MINIMUM ATTACHMENT: AS PER MANUFACTURER'S INSTALLATION xL/L—J"! 8d x 2.5" LONG RING SHANK NAIL MIN. 2%- WOOD RAFTER/JOIST/ GUIDELINES OR #8 x 2" LONG WOOD SCREWS TRUSS AT MAX. 24" O.C. SPACED O.C. IN THE FIELD & AT PLYWOOD EDGES FASTENER PATTERN AT PANEL ENDS TYPICAL PANEL INSTALLATION X—SECTION #9-16 OR #10-14 WOODSCREWS WITH SELF SEAUNG WASHER AT NA%IMUM SPACING OF 24" O.C. 5V-CRIMP MIN 26 GA. THICK (MIN.) (MIN.) ALLOWABLE UPLIFT PRESSURE FASTENER SPACING (IN) PRESSURE (PSI 24 84.5 18 131.3 12 149.6 GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.017"). EFFECTIVE COVERING WIDTH OF PANEL = 24". 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. UNDERLAYMENT PLYWOOD 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. _THIS 19/32" THICK (MIN.) PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM DETAIL 1 REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. w a a U N 0 6 L MI®D=)ADE I MI MIA-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) w .miamidade.nov/economy Metal Sales Manufacturing Ct 545 South 3rd Street, Suite 200 Louisville, KY. 40202 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AM (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AM may immediately revoke,,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 5V Crimp Metal Roofing System LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA#13-0627.02 and consists of pages 1 through 9. The submitted documentation was reviewed by Freddy Semino 0 NOA No.: 18-0313.02 Expiration Date: 06/29/23 Approval Date: 05/03/18 Page 1 of 9 ROOFING SYSTEM APPROVAL: Category Roofing Sub -Category: Metal, Panels (Non -Structural) Material: Steel Deck Type: Wood Maximum Design Pressure-196.75 psE TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specifications Description 5V-Crimp Metal 1= varies TAS 110 Corrosion resistant, galvanized, preformed, Roof w = 24" coated, prefinished, metal panels. h =%", Min. Thickness 0.0179" (26ga.) Min. Yield Strength: 60ksi Trim Pieces 1= varies TAS 110 Standard flashing and trim pieces. w = varies Manufactured for each panel width. Min. Thickness 0.0179" (26ga.) MANUFACTURING LOCATION: 1. Jacksonville, FL. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Akzo Coatings ASTM G 23 ASTM B 117 Valspar Corporation ASTM G 23 ASTM B 117 Underwriters Laboratory R9697 UL 790 October 2016 PRI Construction Materials MSMC-003-02-01 TAS-100 June 2006 Celotex Corporation Testing MTS 520103 ASTM E 8 Jan. 1999 Services Hurricane Test Laboratory, Inc. 0103-0712-09 TAS 125 Sept 2009 Farabaugh Engineering and T240-09 TAS 125 Sept 2009 Testing, Inc. NOA No.: 18-0313.02 MU1MMADE COUNTY Expiration Date: 06/29/23 Approval Date: 05/03/18 Page 2 of 9 APPROVED ASSEMBLIES: System A: 5V-Crimp Metal Roof Panel Deck Type: Deck Description: Maximum Uplift Wood, Non -insulated New Construction 19/32" or greater plywood or wood plank, or for re -roofing 15/32" or greater plywood. See Table A below. Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum 15/32") the above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be an ASTM D 226 Type TI installed with a minimum 4" side - lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12 gauge 1 '/a" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Or, any approved hnderlayment having a current NOA. Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with Metal Sales Manufacturing Corporation's current published installation instructions. Metal Panels and Install the "5V-Crimp Panels" and accessories in compliance with Metal Sales Manufacturing Accessories: Corporation's current, published installation instructions and details. Flashing, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standards RAS 133. Panel fasteners shall be #9-15 x 1%" self drilling, self tapping, hex head screws with scaling washer of sufficient length to penetrate through the sheathing a minimum of 3/h6 inch. Fasteners shall be installed at a maximum spacing as listed in Table A below parallel to the slope. Fasteners shall be installed at a maximum of 12" o.c. at panel edge. See detail herein. TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corners Maximum Design Pressures -74.8 psf. -196.75 psf. Maximum Fastener Spacing 16" o.c. 8" o.c. 1. Extrapolation shall not be allowed NOA No.: 18-0313.02 Expiration Date: 06/29/23 Approval Date: 05/03/18 Page 3 of 9 System B: Deck Type: Deck Description: Maximum Uplift 5V-Crimp Metal Roof Panel Wood, Non -insulated New Construction 19/32" or greater plywood or wood plank, or for re -roofing 15/32" 4r greater plywood. See Table B below. Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum 15/32") the above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be an ASTM D 226 Type 11 installed with a minimum 4" side - lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12 gauge 1 Ya" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Or, any approved underlayment having a current NOA. Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with Metal Sales Manufacturing Corporation's current published installation instructions. Metal Panels and Install the "5V-Crimp Panels" and accessories in compliance with Metal Sales Manufacturing Accessories: Corporation's current, published installation instructions and details. Flashing, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standards RAS 133. Panel fasteners shall be #9-15 x 1%," self drilling, self tapping, hex head screws with sealing washer of sufficient length to penetrate through the sheathing a minimum of 3/16 inch. Fasteners shall be installed at a maximum spacing as listed in Table B below parallel to the slope. Fasteners shall be installed at a maximum of 6" o.c. at panel edge. See detail herein. TABLE B MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner' Maximum Design Pressures -84.5 psf. -131.3 psf. Maximum Fastener Spacing 24" o.c. 18" o.c. 1. Extrapolation shall not be allowed NOA No.: 18-0313.02 Expiration Date: 06/29/23 Approval Date: 05/03/18 Page 4 of 9 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and corners). 3. Panel shall be roll formed in continuous lengths from eave to ridge. Maximum lengths shall be described in the Roofing Application Standard RAS 133. 4. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen below. All clips shall be -permanently labeled with the manufacturer's name and/or logo, and/or model. MIAMI•DADE COUNTY 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 18-0313.02 Expiration Date: 06/29/23 Approval Date: 05/03/18 Page 5 of 9 PROFILE DRAWINGS DETAIL A 5V-CRIMP METAL ROOF PANEL FASTENING PATTERN FOR 5V-CRIMP AT INTERIOR OF PANEL 24" Coverage 5 x 1 1/2" Wcodgrip Screw 5V-Crimp Panel \-Moisture Barrier Plywood Decking (By others) (By others) FASTENING PATTERN FOR 5V-CRIMP AT EAVE NOA No.: 18-0313.02 MUUtFonoecourm Expiration Date: 06/29/23 Approval Date: 05/03/18 Page 6 of 9 i 5V-CRIMP METAL ROOF PANEL SeeTable A Horoin fnr Umvimnm NOA No.: 18-0313.02 Expiration Date: 06/29/23 Approval Date: 05/03/18 Page7 of 9 DETAIL B 24" Coverage #9-15 x 1 1/2" Woodgrip Screw #9-15 x 1 1/2" Woodgrip / //-5V-Crimp Panel ` \.Moisture Barrier Plywood Decking (By others) (By others) FASTENING PATTERN FOR 5V-CRIMP AT INTERIOR OF PANEL FASTENING PATTERN FOR 5V-CRIMP AT EAVE NOA No.: 18-0313.02 Expiration Date: 06/29/23 Approval Date: 05/03/18 Page 8 of 9 SeeTable B Herein for Maximum END OF THIS ACCEPTANCE NOA No.: 18-0313.02 Expiration Date: 06/29/23 Approval Date: 05/03/18 Page 9 of 9