Loading...
HomeMy WebLinkAboutREVISIONOFFICE USE ONLY: DATE FILED: REVISION FEE: Recelvzo Pe APR 041818 Ling S ing 0e t. Lucie cbunt�,partm.., LOCATION/SITE PERMIT # 5 L C Vi 0t -'0 (o 6 4 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUIR-`.'Aj� r"571 FORT PIERCE, F (772) 462- ADDRESS: IAS APPLICATION FOR BUILDING PE PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT REVISIONS: CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: COa+k QUALIFIERS NAME: Loy]C34 AAcj6nl�JA ADDRESS: 103Aa -rW \111144e C-en+er Dr. CITY: Po(f a LAcAe - STATE: FIL PHONE (DAYTR%4E): 13911-4m -3535 OWNER/BUILDER INFORMATION: .NAME: CITY: PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: NAME: N I A ADDRESS:' CITY: PHONE (DAYTIME): SLCCC.- 9123109 Revised 0613 0/17 I ST. LUCIE CO CERT. #: ZIP: 3,q9 81) FAX: 21jej -covq MR METAL SALES MANUFACTURING CORPORATION '26 GA. PBR-PANEL' FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVAL FL 10999.7-113 STRUCTURAL COMPONENTS ROOF DECK Prepared For: Metal Sales Manufacturing Corporation 545 South 3rd Street, Suite 200 Louisville, KY 40202 Telephone: (502) 855-4300 _ Fax: (502) 8554200 O 04 AZ Prepared 1y.3 Prepared By: a9 �� J �S4'4'4 Bala sockalingam, Ph.D., P.E. REVIEWED FOR Florida Professional Engineer #62240 $o- t 1216 N Lansing Ave., suite C CODE COMPLIANCE Tulsa, OK 74106 ST, LUCIE COUNTY Ci wy q�4� Telephone: (918) 492-5992 D®CC y �F c A 4v FAX: (866) 366-1543 This report consists of Evaluation Report (3 Pages including cover) Installation Details (1 Page) GKAL a - Y Manufacturer: Product Name: Panel Description: Materials: Support Description: Slope: FL 10999.7-R3 C2180-7 8.25.2017 Page 2 of 3 Metal Sales Manufacturing Corporation PBR-Panel 36" wide coverage with (4) 1-1/4" high ribs Min. 26 ga., 80 ksi steel or min. 24 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Min. 16 ga., 50 ksi steel section. (Must be designed by others) 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 41.9 psf @ fastener spacing of 60 o.c. (3 or more spans) (Factor of Safety = 2) 154.4 psf @ fastener spacing of 24 o.c. (3 or more spans) Panel Attachment: At panel ends #12-14 x 1-1/4" long SDS with washer @ 7"-5"-7" o.c. across panel width At intermediate #12-14 x 1-1/4" long SDS with washer @ 12" o.c. across panel width Sidelap Attachment: YV-14 x 7/8" long SDS with washer @ 12" o.c. Test Standards: Roof assembly tested in accordance with ASTM E1592-01 `Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference' and FM 4470 Section 5.5 `Resistance to Foot Traffic'. Test Equivalency: The test procedure in ASTM E1592-01 comply with test procedure prescribed in ASTM E1592-05(2012). The test procedure in FM 4470 (1992) comply with test procedure prescribed in FM 4470 (2012). Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE,7-10 using allowable stress design. The maximum support spacing listed herein shall not be exceeded. The design pressure for reduced clip spacing may be computed using rational analysis prepared by a Florida Professional Engineer or based on Metal Sales load span table. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FL 10999.7-R3 C2180-7 8.25.2017 Page 3 of 3 FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: ASTM E1592 Test Reports Farabaugh Engineering and Testing Inc. Project No. T154-06, Reporting Date 5/15/06 FM 4470 Test Report ENCON Technology Inc. C1587-1, Reporting Date 5/17/08 SEE DETAIL 1 PANEL FASTENER PER ALLOWABLE LOAD THIS SHEET TABLE. SPACED MAX 12" O.C. ACROSS RIBS ROOF PANEL (REF. NOTES IN FIELD AND TWO FASTENERS AT EACH RIB PANEL �k PANEL DETAIL) (� 12• (lYP) —mot AT PANEL ENDS (7"-5"-7" SPACING). SIDELIP 1 \ 1/4"-14 X 7/6° SDS WITH WASHER SPACED AT 12 O.C. MIN 16 GA., 50 KSI STEEL TYPICAL PANEL INSTALLATION X—SECTION (DESIGN BY OTHERS) — a 0 0 � NCO Zg� O�N (3� jM1>�^ � W 5N 00 r.. F w STITCH EEF.) 4 4 mm #12-14 X 1 1/4" H.H. CORROSION ¢ RESISTANT PLATED FASTENER WITH GENERAL NOTES: zoN SELF SEALING WASHER. SEE 1. STRUCTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE a ALLOWABLE PRESSURE TABLE FOR FLORIDA BUILDING CODE (FBC). SPACING. 2. PANELS SHALL BE MIN. 26 GA. (t = 0.017"). EFFECTIVE COVERING WIDTH OF PANEL = 36". 3. THE ROOF PANELS SHALL BE INSTALLED OVER STRUCTURE AS SPECIFIED ON u MIN 26 GA. PANEL THESE DRAWINGS. - �'^ E 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS g € PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING &THE FLORIDA MIN 16 GA., 50 KSI STEEL BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM (DESIGN BY OTHERS) REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. PURLINS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. DETAIL 1 i e � MET.gi. SALES MANUFACTURING CORPuiiATION PBR-Panel Uplift Loads (Min 26 ga.) Description Fastener Spacing along panel length (in) Allowable Uplift Load (psf) Coverage width: 36" Panel Fasteners #12-14 x 1.25" long hex head screws with sealed washer Panel fasteners spaced at 12" o.c. across panel width Sidelap fasteners spaced at 12" o.c. 24 154.4 27 137.2 30 123.5 33 112.3 36 102.9 39 95.0 42 85.5 45 74.5 48 65.5 51 58.0 54 51.7 57 46.4 60 41.9 Notes: 1. The bold numbers indicate design loads calculated from test data with safety factor of 2. 2. Panels must be installed as per Evaluation Report FL 10999.7 and Metal Sales current installation procedure. 3. Three or more spans condition. 1216 N Lansing Ave., Suite C Tulsa, Ok 74106 918 492 5992 SOCKAL//V0 E N s F•. 9�'i��' • No 62240 U• w� 0.55% STATE O .:4U c;?'.?L�3.?-01-7 Bala Sockalingam, Ph.D., P.E. FL 62240