HomeMy WebLinkAboutEVALUATION REPORTSCANNED NEMO l etC.
BY Ceraflcate of Authorization 02455
St. Lucie County 353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
EVALUATION REPORT
Polyglass USA, Inc. Evaluation Report P32060.02.09-R24
1111 West Newport Center Drive FL5259-R28
Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009
(954) 233-1230 Revision 24,.01/24/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6tb Edition (2017) Florida Building Code sections noted
herein.
DEscRIPnoN: Polygiass Roof Underlayments
LABELING: Labeling shall -be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nleminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility iocation(s). NEMOIetc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOietc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for Inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
Thefarsimile seal appearing was authorized by Robert Nleminen,
P.E. an 01124/2018. This does not serve as an electronically
signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMOIetc. does not have, nor does It intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO I etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest In any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nleminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the
praducL
S. This is a building code evaluation. Neither NEMOIetc. nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ONEMOletc.
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlaymems, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the Gt6 Edition (2017) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Pro a
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1507.2.3 / 1507.1.1
Physical Properties
ASTM D226
2009
1507.2.4/ 1507.1.1,1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012
2012
2507.11.2
Physical Properties
ASTM D6164
2011
1507.11.2
Physical Properties
ASTM D6222
2011
TAS 130
Accelerated Weathering
ASTM D4798
2011
3. REFERENCES:
ingw
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PHI (TST 5878)
Physical Properties
PRIO1111
04/08/2002
PHI (TST 5878)
Physical Properties
PUSA-005-02-01
01/32/2002
PHI (TST 5878)
Physical Properties
PUSA-013-02-01
12/23/2002
PHI (TST 5878)
Physical Properties
PUSA-013-02-02
12/23/2002
PHI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PHI (TST5878)
Physical Properties
PUSA-018-02-01
07/14/2003
PHI(TST 5878)
Physical Properties
PUSA-028-02-01
07/13/2005
PHI (TST 5878)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PHI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PHI (TST 5878)
Physical Properties
PUSA-061-02-02
01/28/2008
PHI (TST 5878)
Physical Properties
PUSA-076-02-01
02/22/2008
PHI (TST 5878)
Physical Properties
PUSA-083-02-01
04/14/2008
PHI(TST5878)
Physical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
MOH7A
04/01/2008
MTI (TST 2508)
Physical Properties
RXI4EBA
01/29/2009
ERD (TST 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P3740.01.07
01/04/2007
ERD OW 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD (TST 6049)
Physical Properties
P13450.08.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30540.11.09-Rl
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-1
11/30/2009
ERD (TST 6049)
Wind Uplift
P33030.11.09-2
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-3
31/30/2009
ERD (TST 6049)
Physical Properties
P33360.06.30
06/25/2010
ERD (TST 6049)
Physical Properties
P33370.03.11
03/02/2012
ERD (TST 6049)
Physical Properties
P33370.04.11
(14/26/2011
ERD (TST 6049)
Physical Properties
P37300.10.11
10/19/2011
NEMO ETC, LLC. Evaluation Report P12060.02.09-R24
aMflt ofA.dwdmtkn 932455 eEDITION 12017)FBC NON-HVH2 EVALUATION R+159-R28
PaWass Roof Underlayments; (9541233-1230 Revision 24: 01/24/2018
Page 2 of 14
4.
ONEMOletc.
Entity
Examination
Reference
Date
ERD (TST6D49)
Physical Properties
P40390.08.12-1
DS/06/2012
ERD (TST 6049)
Physical Properties
P40390.08.12-2
08/07/2012
ERD (TST 6049)
Physical Properties
C41420.09.12-3
09/11/2012
ERD [W 6049)
Wind Uplift
P39680.03.13
03/04/2013
ERD (TST 6049)
Physical Properties
P45370.04.13
04/26/2013
ERD (TST 6049)
Wind Uplift
P1738.02.07-R2
D4/29/2013
ERD (TST 6049)
Wind Uplift
11757.04.01-1-R1
04/30/2013
ERD CM76049)
Wind Uplift
P41630.08.13
08/06/2013
ERD (TST 6049)
Wind Uplift
P31751.05.03-R3
11/25/2013
ERD(TST 6049)
Wind Uplift
P1178111.03-R1
11/26/2013
ERD (TST 6049)
Physical Properties
P45270.05.14
05/12/2014
ERD (TST 6049)
Physical Properties
6020.07.14-1
09/08/2014
ERD CM 6049)
Physical Properties
6020.09.14-2
09/09/2014
ERD (TSE6049)
Physical Properties
6020.09.14-3
09/08/2014
ERD I TST 6049)
Physical Properties
6020.09.14-4
09/08/2014
ERD (M 6049)
Physical Properties
6020.09.14-5
09/08/2014
ERD M 6049)
Physical Properties
6020.09.14-6
09/08/2014
ERD (TST 6049)
Physical Properties
P46520.10.14
10/03/2014
ERD (TST 60491
Physical Properties
P43290.10.14
10/17/2014
ERD (TST 6049)
Physical Properties
PLYG-SC7550.03.15
03/24/2015
ERD W 6049)
Physical Properties
P40390.04.15
04/03/2015
ERD (TST 60491
Physical Properties
P44360.10.14-R3
05/18/2015
ERD (TST 6049)
Physical Properties
PLYG-SC8080.05.15-1
05/20/2015
ERD(TST 6049)
Wind Uplift
PLYG-SC8905.05.16-1
05/17/2016
ERD (TST 6049)
Physical Properties
PLYG-SC8080.07.16
07/16/2016
ERD(TST 6D49)
Wind Uplift
PLYG-SC32025.30.16
10/12/2016
ERD W 6049)
Physical Properties
PLYG-SC13040.12.16
12/27/2016
ERD (TST 6049)
Physical Properties
PLYG-SC31900.03.17
03/10/2017
ERD (TST 6049)
Physical Properties
PLYG-SC32115.08.17
08/08/2017
ICC-ES(EVL 2396)
IBCCompliance
ESR-1697
11/01/2014
Miami-Dade(CER 1592)
HVHZ Compliance
NOA 14-0717.08
01/22/2015
Polyglass USA
Manufacturing Affidavit
Products Current
02/28/2009
Polyglass USA
P/LAfOdavit
Mule -Hide Cross Ltg
03/O1/2008
Polyglass USA
Materials Affidavit
Polystick SACompound
08/18/2011
UL, LLC (QUA9625)
Quality Control
Service Confirmation
Egp.10105/2018
PRODUCE DESCRiPnON:
4.1.1 Elastobase Is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet
4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet
4.1.4 Polyglass APP Base Is a fiberglass -reinforced, APP modified bitumen base sheet.
4.2.1 Polystick INM or Polystick MTS PLUS is a nominal 60-mil thick rubberized aspha
fiber reinforced, surfaced with polyolefinic film surface; meets FRSAfMI April 2012.
glass
4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM DLWO.
4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2022.
NEMO ETC, LLC Evaluation Report P12060.02.09-R24
ceruJt=W vfAutho,lmtbn a32455 6'" EDMON(2017) FBC NON-HVHZ EVAWATION FLSZS!-R28
Polyglass Roof Underlayments; (9541233.1230 Revision 24: 01/24/2018
Page 3 of 14
A
NNEMO I etc.
4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface; meets FRSA/TRI April 2012.
4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester
fabric surface; meets ASTM D1970 and FRSA/rRI April 2012.
4.2.6 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap sheet and Mule -Hide SA-APP CapSheet (FR) are polyester
reinforced, APP modified bitumen cap sheets; meet FRSAfrRI April 2012.
4.2.7 Polystick Dual Pro" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970.
4.2.8 Polystick Tile Pro" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/rRI April 2012.
4.2.9 Polystick MU-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section
5.8).
4.3.1 Elastoflex G TU is aypolyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS
modified bitumen back -side and granule -surfaced APP modified bitumen top -side: Elastoflex G TU is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet' in the "Two Ply
System" from FRSA/TRI April 2012 (04-.12) beneath mechanically fastened or adhered tile roof systems.
4.3.2 Elastaflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164.
Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380,
Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems.
Elastaflex S6 G is for use as an altemate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened tile roof systems.
4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cop sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/rRI April 2012
(04-12) beneath mechanically fastened or adhered tile roof systems. POWER G FR is for use as an alternate to Heat
Applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI. April 2012 (04-12) beneath mechanically fastened tile
roof systems.
LiMrrATiciNs:
5.2 This is a building code evaluation. Neither NEM01etc. nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use In the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
NENIO ETC, LLG Evaleaoon Report P12060.02.09-R24
ratifmte "fAuthe,hue"n 432455 67 EDITION 120171 FBC NON-NVHZ EVALUATION FL52594t28
Polyglan Raul Undedayments; (954) 233-]230 Revislon 24:01/24/2018
Page 4 of 14
ONEMOjetc.
5.5 Allowable Roof Covers:
>r
m
e
.. a..0 ...:,.. :,..}.tn, .u�:.;`�fi",e��., 3.c
.sA�. �SOE�cQ:�AE)1FQPIn7.
�,us ,i?i�a
C,:"/° -...b ,R..t rai�w"�cY3'L. 1"t�.. •�'. -i
Underlayment
Asphalt Shingles
Nall -On Tile
Foam -On TIIe
Metal
wood shakes
& Sh ngles
slate
Elastabase
Yes
Yes
Yes
Yes
Yes
Yes
iaamsheetln2.pNvwt m)
teamshmtln2-plywy )
Elastobase P
Yes
Yes
Yes
Yes
Yes
Yes
(aee5 eetin2-plysyrlem)
(aamsheetin2-plysyatem)
Polyglass G2 Base
No
Yes
Yes
No
No
No
(Barn Sheeting-plysyrtem)
(Sam sheet in 2-plysystem)
PolyglassAPP Base
No
Yes
Yes
No
No
No
ISaASheetin2-plysystem)
(Bsmsheetln2plyeyAere)
Polystick Mrs or Mrs PLUS
Yes
Yes
No
Yes
Yes
Yes
Polystick lR-Xe
Yes
No
No
No
Yes
Yes
Polystick TUP
No
Yes
Yes (See 5.5.1)
No.
No
No
Polystick TU Plus
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick TU Max
No
Yes
Yes (See 5.5.1)
Yes
No
No
Polystick Dual Pro
Yes
No
No
Yes
Yes
Yes
Polystick Tile Pro
Yes
Yes
Yes (See 5.5.2)
Yes
Yes
Yes.
Polystick MU-X
Yes
No
No
Yes
Yes
Yes
Elastoflex S6G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Elastollex S6 G FR
Yes
Yes
No
No
Yes
Yes
ElastoflexGTU
Yes
Yes
Yes (See 55.1)
No
Yes
Yes
Polyflex6
Yes
Yes
Yes (See 55.1)
No
Yes
Yes
PoWexGFR
Yes
Yes
No
No
Yes
Yes
PoWex SAP or SAP FR
Yes
Yes
Yes (See55.1)
No
Yes
Yes
Mule -Hide SA-APP Cap Sheet
Yes
Yes
Yes (See55.1)
No
Yes
Yes
or SA-APP Cap Sheet (FR)
5.5.1 "Foam -On Tile" is limited to use of the following Approved the adhesives / underlayment combinations.
r..; ,
___TRatE�zS`R.,A110_wABlE�T1ISMOHESIVE
v aAdhesive
J;UNPF�YME ��N_R71_ONSx in�w. z'''-
Florida Product
Underlayments
Approval
DAP Foam Touch'n Seal StormBond Roof
FU4506
Polystick TU Plus, PolystickTU Max
Tile Adhesive
Dow TileBond1e
FL22525
Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® AH-169
FL6332
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset° RTA-1
FL6276
Elastoflex G TU, Elastoflex 56 G, Polyflex G. Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule-H(de SA-APP Cap Sheet (FR)
r Refer to rile Manufacturer's or Adhesive Manufacturer's Florida Product Approval far Overturning Moment Resistance Performance.
NEMO ETC, U.C. Evaluation Report P32060.02.09-R24
cerb)7osu ofauthofimUana324s5 6r"EOITION(2027)FBC NON-HVHZ EVALUATION FL52S9-RZ8
Polyglaw Roof underlaymetds, (9541233-1230 Revision 24: 01/24/2018
Page 5 of 14
ONEMOletc.
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Palystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR) self -adhered to:
➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow .Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels
(designed and installed to meet wind loads for project).
Note. Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should he cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex G TU, Elastoflex 56 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch -applied to:
➢ ASTM D41 primed structural concrete.
5.6.2 Bond -to -insulation:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
➢ ASTM C1269, Type II, Class 1 polyisocyanurete or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
Polyflex G or Polyflex G FR torch -applied to:
➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, Insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -an tile
systems, insulation attachment shall be designed by a qualified design professional and installed based ontesting of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Laver:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch -applied to:
➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For Installations under foam -on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1.
NEMO ETC, LLC. Evaluation Report P12060.02.09RZ4
certJarte ofAuaw,imflonR32455 EDITION (2017)FBC NON-HVH2 EVALUATION FL5259-R23
Poly&w Roof Underlaymems; (3541233-MO Revision 24:01/24/2018
Page 6 of 14
/1 1
ONEMO I etc.
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) doesnot
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-
12), Appendix A, Table IA or FBC 2609 for determination of design wind loads.
#1 Maximum Design Pressure=-90lasf:
Deck: Min. IS/32-Inch plywoodto meet project requirementsto satisfaction of Authority HavingJurisdiction.
Primer: None
Base Pry: (Optional) Polysdck MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, PoWax SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), selfadhered.
#2 Maximum Design Pressure=-97.5 psE
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS or Polysticc MTS PLUS, self -adhered.
Underlayment: Polystick TU. P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back-nalled within the selvedge -edge side laps using 12 ga. x
IN" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 124nch c.c.
#3 Maximum Design Pressure=-105 last:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick Tu Max, Palyflex SAP, Polyflex SAP FR Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
IJ:" ring shank nails through 32 ga., 1-5/8" diameter tin wps spaced 12-inch o.c.
#4 Maximum Design Pressure=-135 psF.
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Havinglurisdiction.
Primer: (Optional) PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Joints: Min. 4-inch wide Mips of Elastoflex SA-V over all plywood joints.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), sect -adhered.
#5 Maximum Design Pressure = -325 P :
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG1OO or ASTM D41
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, selfadhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap
Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#6 Maximum Design Pressure=-622.5osf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#7 Maximum Design Pressure =-30.0lasf•:
Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastabase or Mule -Hide Nall Base (poly -film top surface)
Fasteners: 31 ga. x 1.25-inch long x 1-Inch head diameter round metal cap nails
Spacing: 6-inch o.c, at the 34nch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
NEMO ETC, U.C. EW ILIatlon Report P72060.02.09-1124
Cerffft ecfAvrharlm .032455 eEDMON(2017) FBC NON41VHZ EVAWATION Ft5259428
Polyglass Roof Undarlaymems; (954) 733-_1730 Revision 24: 01/24/2018
Page 7 of 14
ONEMOletc.
#8 Maximum Design Pressure =-37.5 osf•:
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga, x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick NITS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#9 Maximum Design Pressure =-37.5 Vsff:
Deck: Min. 19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type 11 felt
Fasteners: 31 ga. x 1.25-4inch long 1-inch head diameter round metal cap nails
Spacing: Finch o.c at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt
#10 Maximum Design Pressure =-45 psf
Deck: Min. 19/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) layer ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertin caps
Spacing: flinch o.c, at the 2-inch wide side laps and flinch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TO P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FRI, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU, applied in full mopping of hot asphalt
#11 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Havinglurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type II felt
Fasteners: 11ga. x 1.2521nch long x3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-Inch o.c. at the 2-inch wide side laps and 9-Inch o.c at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, .Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot
asphalt.
#12 Maximum Design Pressure =AS psf:
Deck:
Min.35/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
9-inch o.c at the 2-inch wide side laps and 18-Inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#13 Maximum Design Pressure=-52.5 psF.
Deck:
Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
9-inch o.c at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#14 Maximum Design Pressure=-52.5 psf
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
NEMO ETC, U.C. Evaluation Report P12060.02.09-RZ4
rert 4fAurAmlmt&n N32455 e"EDnTON(2017)FBC NON-HVHZ EVALUATION FL5259-RZB
Polyglass Root Underlayments; (954) 233-IMO Revision 24: 01/24/2018
Page 8 of 14
ONEMOletc.
#15 Maximum Design Pressure=-52.5 Dsf:
Deck: Min. 15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.e at the 34nch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows.
Undedaymem: Elastaflex G TU or Elastaflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torchapplied.
#16 Maximum Design Pressure=-60 Dst
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.254nch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/84rich diameter tin raps
Spacing: g4rich o.c, at the flinch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Undedaymem: Elastaflex G TU or Elastoflex 56 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied.
#17 MaArnum Design Pressure = -60 0
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or tom"pplied cap or poly -film surface for torchapplied cap)
Fasteners: CMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c. at the flinch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Undedayment: Elastoflex G TU or Elastaflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#18 Maximum Design Pressure=-67.5 Dsf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied undedoyment)
Fasteners: 12 ga. x L25-Inch long 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps
Spacing: B-inch o.c. at the flinch wide side laps and 8-Inch o.c, at four (4) equally spaced staggered center rows.
Undedayment: Elastaflex G TU or Elastaflex S6. G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#19 Maximum Design Pressure=-75osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of tcrch-applied underloyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgdp #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 104nch o.c. at the flinch wide side laps and 30-Inch o.c. at three (3) equally spaced staggered center rows.
Undedayment: Elastoflex G TU or Elastaflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#20 Maximum Design Pressure=-90 Dsf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c at the 2-inch wide side laps and 64nch o.c. at two (2) equally spaced staggered center rows.
Undedayment: Elastaflex G TU or Elastoflex S6 G, applied in full mapping of hat asphalt or Polynex G, torch -applied.
. #21 Maximum Design Pressure=-90Dsf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction.
Base Sheet: Elastobase(sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3' Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c. at the flinch wide side laps and 6-Inch me at three (3) equally spaced staggered center rows.
Underiayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hat asphalt or Polyflex G, torchapplied.
#22 Maximum Design Pressure=-90 osf•.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast#14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-Inch o.c at the 4-Inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastaflex G TU or Elastoflex 56 G, applied In full mopping of hot asphalt
NEMO ETC, LLG Evaluation Report P12060.02.09-R24
eerulmre ofAetharizWnl324s5 6'x EDmON(2017)FBC NON-HVHZEVAUTATION FI5259.R28
Polyglass Roof Undedayments; (954) Z33-1230 Revision 24:02/24/2018
Page 9 of 24
ONEMOletc.
#23 Maximum Design Pressure=-90 osf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Gahtalume Steel Plates, OMG Roafgrip #14 with
OMG Flat Bottom Plates (Ac uTrac), Trufast HD with Trufast 1winch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 9-Inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastaflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#24 Maximum Design Pressure =-97.5,osf:
Deck: Min. 19/32-inch plywood to meet project requirememsto satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/82inch diameter tin caps
Spacing: 4-inch o.c. at the 4-Inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS or Polystick NITS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#25 Maximum Design Pressure =-205 asf
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hat -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 64nch o.c. at the 2-inch wide side laps and 64nch o.c, at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#26 Maximum Design Pressure=-112.5 Dsf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga.x1.25-inchx3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertinmps
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG300 or ASTM D41 primer at all tin -caps
Base Ply: Polystick MTS or PolystickMTSPLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polynex SAP, PolyflexSAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#27 Maximum Design Pressure=-220 osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface fortorchapplied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c. at the 42inch wide side laps and 6-Inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: ElastoflexIS TU or Elastoflex S6 G, applied in full mopping of hat asphalt or Polyflex G, torch -applied.
#28 Maximum Design Pressure =-120 osf:
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast#12 DP orTrufasr#14 HD with Trufast 3" Metal Insulation Plates
Spacing: Finch o.c. at the 4-loch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt.
5.6.4.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile. systems carry a Maximum
Design Pressure of-45 psf.
NEMO ETC, LLG Evaluation Report P12060.0209-1124
CuWx0U OfAudnvlzanan 032455 e EDITION (2017) FBC NON-HVHZ EVALUATION FI5259•RZe
Polygla%Roof Underlayments; 1954) 233-IMO Revision 24:ag� o 2018
NNEMOjetc.
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/1TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 13.7. Assemblies marked
with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016) for Zone 2/3 enhancements-
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-lays after installation.
Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastaflex G TU shall not be left exposed for
longer than ISO -days after installation.
Polyflex: SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering is to be adhesive -set tile (Elastaflex S5 G or Polyflex G only), in which case the maximum
exposure is 180 days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as
set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance.
5.9 Tile Slippage Limitations (FRSA/TRI April 203.2 (04-121):
When loading roof tiles an the underayment In direct -deck file assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
Underlayment
54TMR.I # 2V 4
Tile Profile
NO
Si lEi.�.4;e Sf�FRiVu ev
Staging Method
v—Wl1 ... €Y 3 i ;
Maximum Slope
Elastoflex G TU
Flat
30-tile stack
7:12
Lugged
&tile stack (6 over 2)
6:12
Elastoflex S6 G or S6 G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MTS or MTS PLUS
Rat
6-tile stack (4 over 2)
5:12
Lugged
Frtile stack (4 over 2)
4:12
Polystick Tile Pro
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polystick TU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:12
Lugged
10-tile stack
6:22
Polystick TUP
Flat
&tile stack (4 over 2)
6:12
Lugged
6-tile stack (4 over 2)
4:22
PotystickTU Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
ID -tile stack
6:12
Polyfl" G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FIR
Rat or Lugged
6dile stack (4 over 2)
4:12
NEMO EM LLG Evaluation Report P12060.02.03R24
QWPcate 4JAuthomauoe B32455 6EDITION (Z017)FBC NON-HVHZ EVALUATION FL5259-RZB
PoWlas Roof Undedayments; (954) 233-1230 Revision 24; 01/24/2018
Page 11 of 14
NNEIVIO I etc.
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3.1 Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type II underayment in FBC Table
2507.1.1 forthe type of prepared roof covering to be installed.
Elastobase, Elastobase P or Mule -Hide. Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA
P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or
Elastoflex S6 6 FR in hot asphalt or Polyflex G or Polyflex G TR, torch applied. Roof cover limitations are those are
those associated with the top -layer underlayment, as set forth in Table 1.
6.3.2 Tile Applications:
-Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the 'Two
Ply System' from FRSA/TR1 April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with
FRSA/TRI April2012 (04-12) Installation Manual.
6.4.2
In FBC Table 1507.1.1 for the type of prepared roof covering to be installed.
Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP
Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -
Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch
diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -
nailed using the above noted fasteners and spacing, in area marked "nail area, area pare clavar' on the face of
membrane. The head lap membrane is to cover the area being back -nailed.
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. hand
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
wew of Ovelap Seam of DWI Pro and Tile Pro
All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap..
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
NEMO ETC LLC. Ewluation Report P12060.02A9-RZ4
[ao7Amte ofauMmaation 932455 eEDITION (2017) FBC NON4MHZ EVALUATION FL5259-RZ8
Polyglass Roof Underlaymemsh (954) 233.1230 Revision 7,4: 01/24/2018
Page 12 of 14
ONEMOletc.
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass P6500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 Ib roller) or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications that allowed for Polystick Dual Pno IR-XeorPahm ckMUX):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
6.4.4 Two (2) Ply Underlayment Systems:
Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex
SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with
the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Polystick MTS or MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use
under foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement,
but is allowable if a 2-ply underlayment system is desired. _
6.5.1 Elastoflex G TLI, Elastaflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published
installation requirements. For use in tile applications:
✓ Elastoflex G TU Is for use as an alternate to "Mineral Surface Roll Rooflng" (ASTM D6380, Class M) In the "Single
Ply System" from FRSA/TRI April 2022 (04-12) beneath mechanically fastened the roof systems or the Hot Asphalt
applied "Cap Sheet" in the " fwo Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply
System" from FRSA/TRI April 2032 (04-22) beneath mechanically fastened the roof systems or the Hot Asphalt
applied "Cap Sheet" In the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems or the Hot Asphalt
applied "Cap Sheet" In the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
6.5.2 For hot -asphalt -applications, Elastoflex G TLI, Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt -applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-Inch beyond the lap edge.
6.6.1 Polyflex G or Polyflex G FR shall be installed In compliance with current Polyglass published installation requirements.
For use in tile applications:
✓ Polyflex G Is for use as an alternate to the Heat Applied "Cap Sheer in the'Two Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6.3).
✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheer in the 'Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3).
NEMO ETC, U.C. Evaluation Report P32060.02A9-R24
rert/flaW DfAuthorhat 832455 e EDITION (2017) FBC NON4fVNZ EVALUATION FL5259-RZB
Polyglass Roof Underiayme ts; (954) 233-IMO Revision 24: 01/24/2018
Page 13 of 14
l�
ONEMOjetc.
6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge.
6.7 Tile StaRinw.
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Table 2 herein, and Polyglass published requirements for file staging.
6.7.2 Battens and/car Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail-
boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 Polyglass specifies the minimum cure time after installation of self -adhering membranes and before loading of
roofing tiles is forty-eight (48) hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
B. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered forFA.C. 616211-3 CIA requirements. The following
plants have qualified products under their respective physical properties specifications.
ASTM D1970
PDlysdck MU-X
Fernley, NV, Hazleton, PA & winter Haven, FL
Hazleton, PA
M-D 13-0004
Elastoflex G TU
Hazleton, PA & winter Haven, FL
ASTM D1970
Polystick IR-Xe
ASTM D2970 & FRSA/TRI April 2012
PolVstick TU Plus
ASTM D2970 & FRSA/rRl April 2012
Polystick TU Max
Tuscaloosa, AL
ASTM D4601, Type II
PDlyglass G2 Base
Winter Haven, FL
ASTM D226 (physicals)
Elastobase, Elastobase P
ASTM D6509
Polyglass APP Base
FRSA/TRI April 2012
Polystick MTS, Polystick MTS PLUS
FRSA(TRI April 2012
Polystick TU P
FRSA/TRI April 2012
Polyflex SAP, Po ex SA P FR
ASTM D1970
Polystick Dual Pro
ASTM 01970 & FRSA/TRI April 2012
Polystick Tile Pro
ASTMD6164
Elastoflex 56, Elastoflex 56 G FR
ASTM D6222
Polyflex G, Polyflex G FR
9. QUALITY ASSURANCE ENTITY:
UL, LLC— QUA9625, (314) 578-3406; k.chancellor@us.ul.com
END OF EVALUATION REPORT -
NEMO ETC, LLC. Evaluation Report P12060.02.09-R24
2,W,mm of Autlron:aaoaa32455 6M EDMON(20171 FBC NON-HVHZEVALUATON FL52594R2B
poly&m Roof Underlaymens, (954) 233-1230 Revision 24: 01/24/2018
Page 14 of 14