HomeMy WebLinkAboutFLORIDA ENERGY EFFICIENCY CODE,FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method RFrG7vrn -- Project Name: COOK ADDITION Builder Name: Street: 12354 HARBOUR RIDGE BLVD. Permit Office: ST. LUCIE COUNTY JA N 18 2019 City, State, Zip: PALM CITY, FL, Permit Number. Owner. MICHAEL COOK Jurisdiction: ST. Lucie County, Permitting Design Location: FL, Fort Pierce County: St. Lucie (Florida Clime e _ 1. New construction or existing Addition 9. Wall Types(1872.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1872.00 ft' b. NIA R= IF 3. Number of units, if multiple family 1 c. WA 12= ft' 4. Number of BedroomgBednns In Addition) 2(0) d. WA R= IF 5. Is this a worst case? No 10. Ceiling Types (1680.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1680.00 ft= 6. Conditioned floor area above grade (ft� 1680 b. WA R-- ft' Conditioned floor area below grade (ft') 0 c. N/A R= ft' 11. Ducts R fY 7. Windows(205.0 sgft) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 40 a. U-Factor. Sgl, U=0.60 109.00 fl' SHGC: SHGC=0.24 b. U-Factor: Sgl, U=0.69 96.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.22 a. Central Unit 29.2 SEER:14.00 c. U-Factor. N/A ft' SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor. N/A ft' a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft Area Weighted Average SHGC: 0.231 14.Hot water systems -None required 8. Floor Types (1680.0 sqft.) Insulation Area a. Cap: WA a. Slab -On -Grade Edge Insulation R=0.0 1680.00 ft' b. Conservation features EF: 0.000 b. NIA R= fN c. WA R= ft' 15. Credits CF, Pstat Glass/Floor Area: 0.122 Total Proposed Modified Loads: 54.30 PASS Total Baseline Loads: 56.04 I hereby certify that the plans and specifications covered by Review of the plans and 5T1l this calculation are in compliance with the Florida Energy specifications covered by this Cade. calculation indicates compliance with the Florida Energy Code. N ner,'�c••., .;%,z - „,.�3 n O PREPA E Y Before construction is completed r DATE: this building will be inspected for compliance with Section 553.908 O - I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. (''Op WE OWNER/ACi NT' BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACHSO (R402.4.1.2). SCANNED BY St. Lucie County 1/15/2019 8:36 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Tite: COOK ADDITION Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1680 Lot# Owner Name: MICHAEL COOK Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street 12354 HARBOUR RID Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fen: No City, Stale, Zip: PALM CITY, Family Type: Single-family FL, NewOdsting: Addition Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fart Pierce FL_VERO BEACH_MUNI 39 90 70 75 299 62 LOW BLOCKS Number Name Area Volume _ 1 Entire House 1680 15120 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 EXISTING 1620 13680 Yes 3 2 1 Yes Yes Yes 2 ENCLOSED LANI 160 1440 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio EXISTING 182 ft 0 1520 fN _ 0 1 0 2SIab•On-Grade Edge Insulatio ENCLOSED LANI 26 ft 0 160 ft' — 0 1 0 ROOF J Roof Gable Roof Solar SA Emitt Emitt Deck Pitch �Insul. # Type Materials Area Area Color Absor. Tested Tested (deg) ` 1 Hip Flat the/slate 1771 ft' Oft- Medium 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 In) Area RBS IRCC 1 Full attic Vented 150 1680 ft' N N 1/15/2019 8:36 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Vented) EXISTING 30 Blown 1520 ft' 0.1 Wood 2 Under Attic (Vented) ENCLOSED LANI 30 Blown 160 ft' 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 N Exterior Concrete Block- Ext lnsrffXISTING 4.1 55 0 9 0 495.0 fP 0 0 0.4 0 -2 E Exterior Concrete. Block- Ext InsdtXISTING 4.1 44 a 9 0 396.0 ft 0 0 0.4 0 -3 S Exterior Concrete Block - Ext InsLEXISTING 4.1 55 0 9 0 495.0 ft' 0 0 0.4 0 -4 W Exterior Concrete Block - Ext InsLEXISTING 4.1 28 0 9 0 252.0 ft' 0 0 0.4 0 -5 N Exterior Concrete Block- Ext InEffiNCLOSED 4.1 5. 0 9 0 45.0 ft' 0 0 0.4 0 _ 6 S Exterior Concrete Block- Ext InsENCLOSED 4.1 5 0 9 0 45.0 ftx 0 0 0.4 0 7 W Exterior Concrete Block - Ext -.InffNCLOSED 4.1 16 0 90 144.0 It" 0 0 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated EXISTING None .39 3 7 21 ft' WINDOWS Orientation shown is the entered Proposed orientation. Wall Overhang J # Omt ID Frame Panes NFRC U-Factor SHGC Imp.. Area Depth Separation Int Shade 'Screening _ 1 E 2 Metal Low-E Single Yes 0.6 0.24 N 4.0 fF 2 It 0 in 1 ft 4 in None None 2 -E 2 Metal Low-E Single Yes 0.6 0.24 N 20.0 ft' 2 ft 0 in 1 1114 in None None 3 E 2 Metal Low-E Single Yes 0.6 0.24 N 25.0 (P 2 ft 0 In 1 ft 4 in None None 4 W 4 Metal Low-E Single Yes 0.6 0.24 N 60.0 W 2 ft 0 in 1 ft 4 in None None 5 W 7 Metal Low-E Single Yes 0.69 0.22 N 96.0 ft' 2 ft 0 in 1 ft 4 in None None INFILTRATION yt Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .0004 1764 96.84 182:12 .3005 7 HEATING SYSTEM # System Type Subtype Efficiency... Capacity -Block Ducts 1 Electric Strip Heat/Exlsting/co None COPA 27 kBtu/hr 1 sys#1 1/15/2019 8:36 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Euisting/confirms Split SEER: 14 29.2 kBlufhr cfm 0.88 1 sy5#1 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF ft' DUCTS / —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 40. ft' _ Attic 1 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Progremablre T]hermosta[[t:]]Y Fans: Cl [[ Heat ng Jan tX) Feb iXi Mar Henbng Aprreiling Apr May [)C) JMay un [ ) Jul [X] [ ) Aug t ] [ ] Ir7�' Sep LJ Occtt Nov [rX'] Dee Dec [ I Jan [[ 11 Feb [[XR]) Mar l l [ Jun [ 1 Jul I) Aug EX) ) Sep IXl -[X] [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (VVD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78- 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68. 68. 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(81bs/sq.fL 0 ft= 0 It 0.3 EXISTING Default 81bs/s at. fP ft 0.3 ENCLOSED LANI Name: Rating Compant: 1/15/2019 8:36 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 4 of 4 ,2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: COOK ADDITION Builder Name: Street: 12354 HARBOUR RIDGE BLVD. Permit Office: ST. LUCIE COUNTY City, State, Zip: PALM CITY, FL, Permit Number. X Owner. MICHAEL COOK Jurisdiction: w Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall.. be. installedin the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements - .Breaks orjoints in the air barrier shall be sealed. Ceiling/attic The air barrier In any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attics aces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated. by completely filling the cavity sealed, with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be Installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation: shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloar decking, or floor framing: cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor Insulation, Insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed: Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on Installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures, installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelopeshall be airtight and IC rated. ' Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall ShowerRub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed In a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snrinklar cover plates and walls or cafflnaq I a. In addition, inspection of log walls shall be in accordance with the provisions of ]CC-400. 1/16/2019 8:36 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 201T EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX' = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply duds R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location AtticiAtfic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 29.2 a) Split system SEER . .14.0 5. Is this a worst case? (yes/no) 5. No b) Single package BEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1680 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor.(weighted average) 7a. 0.642 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.231 c) Area 7c. 205.0 8. Skylights a) U-factor.(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b- NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior. 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 9. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 90. 10A1. 10A2. 4.1 14. Heating system: Capacity 27.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas fumace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF b) Gas fired, natural gas EF d) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec%- g) Other 10131. 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans Yes 11a. 30.0 b) Cross ventilation No 11 b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Cade, Energy Conservation, if not DEFAULT. I certify that this home has compiled with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, anew EPL display card will be completed based on installed code compliant features. q �I BuilderSignature:�� Date: Address of New Home: 12354 HARBOUR RIDGE BLVD. City/FL Zip: PALM CITY. FL 1/15/2019 8:36:34 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1