Loading...
HomeMy WebLinkAboutWIND LOAD ANALYSISWIND LOADS ANALYSIS I FEB 0 5 2019 Date : 12/5/2018 Project No. AH lel ?t Company Name : Advance Hurricane Protection Designed IS : P.E. l li €1e�OR4S'l�': Address Address10152 S Ocean Or 417 B Description New ers City St Lucie Customer Name Will Marino Residence State Florida Proj Location Jensen Beach FL, 34957 File Location: T:\Clients\AHP\JOBS\2018\18003 Marino Residence\Wind Loads\Marino reside[ mecawind.wnd Input Parameters: Directional Procedure All Heights Building (Ch 27 Part 1) Basic Wind Speed(V) - 165.00 mph Structural Category - III Exposure Category = D Natural Frequency - N/A Flexible Structure = No Importance Factor - 1.00 Kd Directional Factor = 0.85 Alpha = 11.50 Zg = 700.00 ft At - 0.09 Bt = 1.07 Am - 0.11 B. = 0.80 Cc - 0.15 1 = 650.00 ft Epsilon = 0.13 Zmin 7.00 £t Pitch of Roof = 0 : 12 Slope of Roof(Theta) = .00 Deg h: Mean Roof He - 70.00 ft Type of Roof = FLAT Me: Ridge Ht 70.00 ft Eht: Eave Height = 70.00 ft OH: Roof Overhang at Eave= .00 ft Overhead Type = No Overhang Bldg Length Along Ridge = 260.00 ft Bldg Width Across Ridge= 50.00 £t Gust Factor Calculations Gust Factor Category I Rigid Structures - Simplified Method Gustl: For Rigid Structures (Nat. Freq.>l Hi) use 0.85 0.85 Gust Factor Category II Rigid Structures - Complete Analysis Zm: 0.6*Ht = 42.00 ft lzm: Cc*(33/Zm)^0.167 = 0.14 Lem: 1*(Zm/33)^Epsilon = 669.89 ft Q: (1/(1+0.63*((B+Ht)/Lzm)^0.63))^0.5 0.91 Gust2: 0.925*((1+1.7*lrm*3.4*0)/(1+1.7*3.4*1rm)) 0.89 Gust Factor Summary Not a Flexible Structure use the Lessor of Gustl or Gust2 = 0.85 Table 26.11-1 Internal Pressure Coefficients for Buildings, GCpi GCPi : Internal Pressure Coefficient = +/-0.18 Wind Pressure Main Wind Force Resisting System (MWFRS) - Ref Figure 27.4-1 Kh: 2.01*(Ht/Zg)^(2/Alpha) = 1.35 Kht: Topographic Factor (Figure 6-4) = 1.00 Qh: .00256*(V)^2*I*Kh*Kht*Kd 47.87 psf Cpww: Windward Wall Cp(Ref Fig 6-6) = 0.80 Roof Area = 13000:00 £t^2 Reduction Factor based on Roof Area = 0.80 Wind Pressure on Components and Cladding (Ch 30 Part 3) All pressures shown are based upon MD Design, with a Load Factor of .6 Width of Pressure Coefficient Zone 'a" = = 5.00 ft Description Width Span Area Zone Max Min Mar P Min P Elev ft £t ft^2 GCE, GCp psf psf ft Shutter (Mark 1. 7.00 3.92 27.4 4 0.87 -0.88 50.29 -50.76 70.0 Shutter (Mark 2 3.67 3.92 14.4 4 0.90 -0.90 51.70 -51.70 70.0 Shutter (Mark 3 11.50 8.21 94.4 4 0.76 -0.80 44.78 -47.08 70.0 Shutter (Mark 4 10.25 4.92 50.4 4 0.81 -0.84 47.58 -48.95 70.0 Khcc:Comp. & Clad. Table 6-3 Case 1 Qh.r:.00256*V^2*Khcc*Kht*Kd FILE COPY F6P'Wt?tr-(-9v 0-72-,-Vo q r�- SCANNED BY St. Lucie County ADVANCED HURRICANE PROTECTION 4 O LL LU N n Q m Z Om i LU 6u LU O U v w w p�m O zov O D E S I G N = 1.35 18 DESIGN & PERMITTING,INC. = 47.87 psf 6499 POWERLINE RD., #203 FORT LAUDERDALE, FL. 33309 TEL; 754-701-7126 WWW.JBDTEAM.COM ,•.. ,� nn. 0JBDeziBn&PermRDn&_Inc.2017 �J�\v�GEh'SFry�F� '.A275_'-. A'. Q STATE OF FLORIDA NO.37275 SHEEP# A.1