Loading...
HomeMy WebLinkAboutPLANS'a E _ WFTPIERCE FA # 10080502 CROWN CASTLE BU# 813812 CROWN APPLICATION #1482523 at&t 8701 ORANGE AVENUE SCANNED FORT PIERCE, FL 34945 BY St. Lucie County TOWER UPGRADE - 4C/5C/6C/4TX4RX/4TX4RX PACE JOB #: MRSFLO16371 LOCATION MAP APPROVALS DESIGN CRITERIA INDEX OF DRAWINGS FLORIDA BUILDING CODE ( PER EDITION) 5 —17 OF x �❑ I ANSIE 7-1 -222-G (ALLOWED PER EXEMPTION #5 OF 1609.1.1) SHT' DESCRIPTION REV � .t - , ❑I 4�—� /SCE 7-10 NO. N0. ------U VULT = 157 MPH ULTIMATE 3 SECOND GU PROPERTY OWNER DATE ( T-1 TITLE SHEET VASD = 122 MPH (NOMINAL 3 SECOND GUST) RF ENGINEER DATE RISK CATEGORY = II GN-1 GENERAL NOTES, ABBREVIATIONS _._..._. o EXPOSURE asC ARCHITECTURAL CIVIL PLANS IMPORTANCE FACTOR- 1.0 / CONSTRUCTION DATE wl -NATIONAL ELECTRICAL CODE, 2014 .EDITION (TIFF/ 70-2014) C-1 SITE PLAN w sire LocAno - FLORIDA FIRE PREVENTION CODE (2015) £ f/0 SITE ACQUISITION DATE - CONTRACTOR TO CONFIRM THAT THE SITE IS COMPLIANT WITH STRUCTURAL PLANS RF WARNING SIGNAGE &EMERGENCY SIGNAGE AS REQUIRED BY I x DATE THE FEDERAL GUIDELINES CONTAINED WITH OET 65 BULLETIN & S-1 TOWER ELEVATI ZONING ON AND ANTENNA ORIENTATION NETWORK DATE AS PER AT&T GUIDELINES S-2 MISCELLANEOUS DETAILS CONSTRUCTION NOTES S-3 MISCELLANEOUS DETAILS OPERATIONS DATE ANTENNA PLANS 1. CONTRACTOR SHALL VEMFY ALL PLANS MID EXISTING DIMENSIONS AND m CONTRACTOR CONDITIONS ON THE JOB SITE AND SHALL IM BEIAIELY NOTIFY THE 'y g DATE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH -1 ANTENNA SCHEDULE N pH THE WORK OR BE RESPONSIBLE FOR SaME ELECTRICAL PLANS n I! 2. CONTRACTOR SHALL CONTRACT AT&T IMPLEMENTATION PM OR E-1 ANTENNA RISER DIAGRAM ro SITE FE FOR ACCESS REQUIREMENTS. VICINITY MAP PROJECT SUMMARY a THIS PRO FLT corasls of THE INsuunoN OF. _ c (3TCV)rFR /8664-8843-8843, EW ANTENNAS. (Arlo ALL ASSaaATED3) REPLACEMENT es/B s SITE NAME: WFTPIERCE GROUND WOW- ( &&� FA SITE NUMBER: as 10080502 ALL ASSOCIATEDTED WOW, OIrEhEfJf B14-4478, (6) NEW gPlD9RS, & ca 5 e1 4. MUM WILL BE OFF AIR FOR 4-7 DAYS DURING ANTEIM MOUNT PARCEL: 2311-320-0000-000/4 INSTALLATION. F F-- Q 3 ;; :,.� w� y„-t'"1�� ��a� �E COUNTY: ST LUCIE - W y } § " 3 [ood JURISDICTION: ST LUCIE COUNTY Y CONTACTS J E m n\ c ) , t SITE COORDINATES: N 27.4455944' APPLICANT: I W 80.4127944• CANT: a 3 sRELOOC AnON SITE TYPE: 4C/5C/6C/4TX4RX/4TX4RX �. 8601 W SUNRISE BLVD I: i " STRUCTUREPLANTATION, FL 33322RE TYPE: SELF SUPPORT TOWER E'. w I TOWER HEIGHT: 250'-0' AGL n 1 TOWER OWNER: p CN�i Sivas CROWN CASTLEC.L. ANTENNA HEIGHT: 146'-0" AGL t o �f 6420 CONGRESS AVENUE, SUITE 2000 �+ n u BOCA RATON, FL 33487 lo a1 ENGINEER: P"o` -- 1-- -� USA ENGINEERING w ry'�g 2818 CYPRESS RIDGE BLVD. SUITE 110 CL( - o —'j --- WESLEY CHAPEL,—FL-33544 ---- a - CONTACT: MARC P. MAIER, P.E. DRIVING DIRECTIONS PHONE: (813) 994-0365 o PROJECT REFERENCES OFPPRT FROM AT&T OFFICE 9801 W. SUMdSE BLVD., PWJTp110N, R. 33322 PROJECT INFORMATION 1. Depart SR -SW W / W SanHss Blvd toward N Pine Island Rd 0.4 mI 1. THESE PLANS WERE COMPLETED PER PRELIMINARY/APPROVED 1. THIS IS AN UNMANNED FACILITY AND WILL BE USED FOR THE TRANSMISSION OF RADIO SIGNALS FOR THE PURPOSE OF 2. Tam back on for Ro E / W Sunrise oral Pods Orlando ]-Eleven an the n9M1t i, 1.0 mi 4.1 mi LTE 5C RFDS ID#: 2591079 V1.00, DATED 01/28/19. PROVIDING PUBUC CELLULAR SERVICE. ]. Taus name Leta for Florian: Turnpike SR North Lard F Oierce Toll Bch 9a.0 mi CONTRACTOR SHALL REQUEST CURRENT RFDS & WORKBOOK 2c a. At exit straight tote more right far SR-7o toward Ft Pierce / Vero Bch os mi FROM CONSTRUCTION MANAGER PRIOR TO CONSTRUCTION. 2. AT&T CERTIFIES THAT THIS EQUIPMENT FACILITY WILL BE SERVICED ONLY BY AT&T EMPLOYEES AND SUBCONTRACTORS AND 5. Keep stmigM1l onto SR-71] / S Kings Hwy Pass Love's Country Store in 2.4 mi 2.4 mi ,�„ a. Turn left onto Orange Ave / CR-fin W Inve's Country Store on the comer 0.9 Tut THE WORK ASSOCIATED WITH ANY EQUIPMENT CANNOT BE PERFORMED BY HANDICAPPED PERSONS. THIS FACILITY WILL BE z ArHw at 8701 Ormyie Avenaa R Pierce FIL. 34945 FREQUENTED ONLY BY SERVICE PERSONNEL FOR REPAIR PURPOSES ONLY. w 3. NO POTABLE WATER SUPPLY IS TO BE PROVIDED AT THIS LOCATION. 4. NO WASTEWATER WILL BE GENERATED AT THIS LOCATION. REV DATE OMRIPIION A 1IM119 PRELIMINARY CDs REV 'A' 0 2/4/19 REV 0 GO. ISSUED US1, DIG PROJECT NO.: 12190001-11 DFNWN 9Y: CHECKED W. ML FN ..,—+sue► • • 8601 W SUNRISE BLVD PLANTATION, FL 33322 010"'*4 CROWN w,.o CASTLE 6420 CONGRESS AVE SUITE 2000 BOCA RATON, FL 33487 PREPARED BY: ®IENGINEERING 2818 CYPRESS RIDGE BLVD. sun 110 WISILEY CHAPEL FL 3354E L FEBRUARY 04, 2019 MARC P. MAIER, PE FL PROFESSIONAL ENGINEER LIC. p 72513 WFTPIERCE FA #10080502 CC BU# Si38312 8701 ORANGE AVE FT PIERCE, FL 34945 TITLE SHEET SHEET NUMBER 1 1 5. NO SOLID WASTE WILL BE GENERATED AT THIS LOCATION. ) I T-1 LH�I.L�IN�I•�6I�i1 1. ALL REFERENCES TO OWNER HEREIN SHALL BE CONSTRUED TO MEAN AT&T OR IT'S DESIGNATED REPRESENTATIVE. 2. ALL WORK PRESENTED ON THESE DRAWINGS MUST BE COMPLETED BY THE CONTRACTOR UNLESS NOTED OTHERWISE. THE CONTRACTOR MUST HAVE CONSIDERABLE EXPERIENCE IN PERFORMANCE OF WORK SIMILAR TO THAT DESCRIBED HEREIN. BY ACCEPTANCE OF THIS ASSIGNMENT, THE CONTRACTOR IS ATTESTING THAT HE DOES HAVE SUFFICIENT EXPERIENCE AND ABILITY, THAT HE IS KNOWLEDGEABLE OF THE WORK TO BE PERFORMED AND THAT HE IS PROPERLY LICENSED AND PROPERLY REGISTERED TO DO THIS WORK IN THE STATE AND/OR COUNTY IN WHICH IT IS TO BE PERFORMED. 3. UNLESS SHOWN OR NOTED OTHERWISE ON THE CONTRACT DRAWINGS, OR IN THE SPECIFICATIONS, THE FOLLOWING NOTES SHALL APPLY TO THE MATERIALS LISTED HEREIN, AND TO THE PROCEDURES TO BE USED ON THIS PROJECT. 4. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE TO INSURE THE SAFETY OF THE STRUCTURE AND ITS COMPONENT PARTS DURING ERECTION AND/OR FIELD MODIFICATIONS. THIS INCLUDES, BUT IS NOT LIMITED TO, THE ADDITION OF WHATEVER TEMPORARY BRACING, GUYS OR TIE DOWNS THAT MAY BE NECESSARY. SUCH MATERIAL SHALL BE REMOVED AND SHALL REMAIN THE PROPERTY OF THE CONTRACTOR AFTER THE COMPLETION OF THE PROJECT. 5. ALL DIMENSIONS, ELEVATIONS, AND EXISTING CONDITIONS SHOWN ON THE DRAWINGS SHALL BE FIELD VERIFIED BY THE CONTRACTOR AND THE TESTING AGENCY PRIOR TO BEGINNING ANY MATERIALS ORDERING, FABRICATION OR CONSTRUCTION WORK ON THIS PROJECT. ANY DISCREPANCIES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER AND THE OWNER'S ENGINEER. THE DISCREPANCIES MUST BE RESOLVED BEFORE THE CONTRACTOR IS TO PROCEED WITH THE WORK. THE CONTRACT DOCUMENTS DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. OBSERVATION VISITS TO THE SITE BY THE OWNER AND/OR THE ENGINEER SHALL NOT INCLUDE INSPECTION OF THE PROTECTIVE MEASURES OR THE CONSTRUCTION PROCEDURES. 6. ALL MATERIALS AND EQUIPMENT FURNISHED SHALL BE NEW AND OF GOOD QUALITY, FREE FROM FAULTS AND DEFECTS AND IN CONFORMANCE WITH THE CONTRACT DOCUMENTS. ANY AND ALL SUBSTITUTIONS MUST BE PROPERLY APPROVED AND AUTHORIZED IN WRITING BY THE OWNER AND ENGINEER PRIOR TO INSTALLATION. THE CONTRACTOR SHALL FURNISH SATISFACTORY EVIDENCE AS TO THE KIND AND QUALITY OF THE MATERIALS AND EQUIPMENT BEING SUBSTITUTED. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. THE CONTRACTOR IS RESPONSIBLE FOR INSURING THAT THIS PROJECT AND RELATED WORK COMPLIES WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL SAFETY CODES AND REGULATIONS GOVERNING THIS WORK. 8. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE LATEST EDITION OF THE LOCAL BUILDING CODE. 9. ALL PROPOSED CELLULAR EQUIPMENT AND FIXTURES SHALL BE FURNISHED BY OWNER FOR INSTALLATION BY THE CONTRACTOR, UNLESS SPECIFICALLY NOTED OTHERWISE HEREIN. 10. ACCESS TO THE PROPOSED WORK SITE MAY BE RESTRICTED. THE CONTRACTOR SHALL COORDINATE INTENDED CONSTRUCTION ACTIVITY, INCLUDING WORK SCHEDULE AND MATERIALS ACCESS, WITH THE RESIDENT LEASING AGENT FOR APPROVAL- 1. STRUCTURAL STEEL SHALL CONFORM TO THE LATEST EDITION OF THE A.I.S.C. SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS- ALLOWABLE STRESS DESIGN AND PLASTIC DESIGN INCLUDING THE COMMENTARY AND THE A.I.S.C. CODE OF STANDARD PRACTICE. 4. ALL COAXIAL CABLE CONNECTORS AND TRANSMITTER EQUIPMENT SHALL BE AS SPECIFIED BY THE OWNER AND IS NOT INCLUDED IN THESE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL FURNISH ALL CONNECTION HARDWARE REQUIRED TO SECURE THE CABLES. CONNECTION HARDWARE SHALL BE GRADE 304 STAINLESS STEEL. 5. ALL REINFORCING STEEL SHALL CONFORM TO ASTM 615 GRADE 60, DEFORMED BILLET STEEL BARS. WELDED WIRE FABRIC REINFORCING SHALL CONFORM TO ASTM A185. 6. THE FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO THE LATEST A.I.S.C. SPECIFICATIONS. 7. ALL CONNECTIONS NOT FULLY DETAILED ON THESE PLANS SHALL BE DETAILED BY THE STEEL FABRICATOR IN ACCORDANCE WITH A.I.S.C. SPECIFICATIONS. B. HOT -DIP GALVANIZE ITEMS SPECIFIED TO BE ZINC -COATED, AFTER FABRICATION WHERE PRACTICAL. GALVANIZING: ASTM A 123, ASTM, A 153/A 153M OR ASTM A 653/A 653M, G90, AS APPLICABLE. 9. REPAIR DAMAGED SURFACES WITH GALVANIZING REPAIR METHOD AND PAINT CONFORMING TO ASTM A 780 OR BY APPLICATION OF STICK OR THICK PASTE MATERIAL SPECIFICALLY DESIGNED FOR REPAIR OF GALVANIZING. CLEAN AREAS TO BE REPAIRED, AND REMOVE SLAG FROM WELDS. HEAT SURFACES TO WHICH STICK OR PASTE MATERIAL IS APPLIED WITH A TORCH TO A TEMPERATURE SUFFICIENT TO MELT THE METALLICS. IN STICK OR PASTE, SPREAD MOLTEN MATERIAL UNIFORMLY OVER SURFACES TO BE COATED AND WIPE OFF EXCESS MATERIAL. 10. CONTRACTOR SHALL FOLLOW THE MANUFACTURER'S INSTRUCTIONS/SPECIFICATIONS IF NO INFORMATION IS CONTAINED IN THESE PLANS OR IF THE MANUFACTURER'S SPECIFICATIONS ARE STRICTER. PERMITS, 1. CONTRACTOR SHALL SECURE ALL NECESSARY PERMITS FOR THIS PROJECT FROM ALL APPLICABLE GOVERNMENTAL AGENCIES. 2. ANY PERMITS WHICH MUST BE OBTAINED SHALL BE THE CONTRACTOR'S RESPONSIBILITY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ABIDING BY ALL CONDITIONS AND REQUIREMENTS OF THE PERMITS. 3. ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES AND THE ACI 318-14, "BUILDING REQUIREMENTS FOR STRUCTURAL CONCRETE". 4. THE CONTRACTOR SHALL NOTIFY THE APPLICABLE JURISDICTIONAL (STATE, COUNTY OR CITY) ENGINEER 24 HOURS PRIOR TO THE BEGINNING OF CONSTRUCTION. 5. ALL DIMENSIONS SHALL BE VERIFIED WITH THE PLANS (LATEST REVISION) PRIOR TO COMMENCING CONSTRUCTION. NOTIFY THE OWNER IMMEDIATELY IF DISCREPANCIES ARE DISCOVERED. THE CONTRACTOR SHALL HAVE A SET OF APPROVED PLANS AVAILABLE AT THE SITE AT ALL TIMES WHEN WORK IS BEING PERFORMED. A DESIGNATED RESPONSIBLE EMPLOYEE SHALL BE AVAILABLE FOR CONTACT BY GOVERNING AGENCY INSPECTORS. 1. ALL THREADED STRUCTURAL FASTENERS FOR ANTENNA SUPPORT ASSEMBLES SHALL CONFORM TO ASTM A307 OR ASTM 36. ALL STRUCTURAL FASTENERS FOR STRUCTURAL STEEL FRAMING SHALL CONFORM TO ASTM A325. FASTENERS SHALL BE 5/8" MIN. DIA. BEARING TYPE CONNECTIONS WITH THREADS EXCLUDED FROM THE PLANE. ALL EXPOSED FASTENERS, NUTS, AND WASHERS SHALL BE GALVANIZED UNLESS OTHERWISE NOTED. ALL ANCHORS INTO CONCRETE SHALL BE STAINLESS STEEL 2. THE CONTRACTOR SHALL FURNISH ALL CONNECTION HARDWARE REQUIRED TO SECURE THE CABLES. CONNECTION HARDWARE -SHALL BE STAINLESS STEEL. 2. STRUCTURAL STEEL PLATES AND SHAPES SHALL CONFORM TO ASTM A36. ALL 3. NORTH ARROW SHOWN ON PLANS REFERS TO TRUE NORTH. CONTRACTOR SHALL STRUCTURAL STEEL PIPES SHALL CONFORM TO ASTM A53 GRADE B. ALL VERIFY NORTH AND NOTIFY CONSULTANT OF ANY DISCREPANCY BEFORE STARTING STRUCTURAL STEEL TUBING SHALL CONFORM TO ASTM A500 GRADE B. ALL CONSTRUCTION. STRUCTURAL STEEL COMPONENTS AND FABRICATED ASSEMBLIES SHALL BE HOT DIP GALVANIZED AFTER FABRICATION. 4. PROVIDE LOCK WASHERS FOR ALL MECHANICAL CONNECTIONS FOR GROUND CONDUCTORS. USE GRADE 304 STAINLESS STEEL HARDWARE THROUGHOUT. 3. WELDING SHALL BE IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY (AWS) 5. THOROUGHLY REMOVE ALL PAINT AND CLEAN ALL DIRT FROM SURFACES D.1.1/D1.1M:2010. STRUCTURAL WELDING CODE -STEEL WELD ELECTRODES SHALL REQUIRING GROUND CONNECTIONS. BE E7OXX. 6. MAKE ALL GROUND CONNECTIONS AS SHORT AND DIRECT AS POSSIBLE. AVOID SHARP BENDS. ALL BENDS TO BE A MIN. OF 8" RADIUS. 7. FOR GROUNDING TO BUILDING FRAME AND HATCH PLATE GROUND BARS, USE A TWO -BOLT HOLE NEPA DRILLED CONNECTOR SUCH AS T&B 32007 OR APPROVED EQUAL 8. FOR ALL EXTERNAL GROUND CONNECTIONS, CLAMPS AND CADWELDS, APPLY A LIBERAL PROTECTIVE COATING OR AN ANTI -OXIDE COMPOUND SUCH AS 'NO -OXIDE A' BY DEARBORN CHEMICAL COMPANY. 9. REPAIR ALL METAL SURFACES THAT HAVE BEEN CUT OR DAMAGED BY REMOVING ANY EXISTING RUST AND APPLYING COLD GALVANIZATION. 10. ANTENNA CABLE LENGTHS HAVE BEEN DETERMINED BASED ON THESE PLANS. CABLE LENGTHS LISTED ARE APPROXIMATED AND ARE NOT INTENDED TO BE USED FOR FABRICATION. DUE TO FIELD CONDITIONS, ACTUAL CABLE LENGTHS VARY. CONTRACTOR MUST FIELD VERIFY ANTENNA CABLE LENGTHS PRIOR TO ORDER. REV DATE DESCRIP1ION A 1/29/19 PRELIMINARY CDs REV 'A' 0 2/4/19 REV 0 CDs MUM USA ENG PROD C NO.: 12190001-11 DRAWN WY: CHECKED W. ML FN q at&t 8601 W SUNRISE BLVD PLANTATION, FL 33322 Cis CROWN v CASTLE 6420 CONGRESS AVE SUITE 2000 BOCA RATON, FL 33487 PREPARED BY: ®IENGINEERING 2818 CYPRESS RIDGE BLVD. sun 110 WESlE1' CHAPEL FL 33544 LFL 3ODA9J3 705 SAD% G r 7���G E •"�' >$ NO 7251$ --; e " S 1- �F ° 00 V, ONAL =EBRUARY 04, 2019 MARC P. MAIER, PE FL PROFESSIONAL ENGINEER UC. # 72513 WFTPIERCE FA #108SO58z CC BU# 813812 8701 ORANGE AVE FT PIERCE, FL 34945 GENERAL NOTES, ABBREVIATIONS SHEEP NUILBER G N-1 NOTES: 1. CONTRACTOR TO FILL ANY EXISTING GRAVEL AREAS THAT ARE DISTURBED DURING THE COURSE OF CONSTRUCTION, GRAVEL TO MATCH EXISTING. 2. THE CONTRACTOR TO ENSURE THAT NO DAMAGE OR DEBRIS OCCURS ON THE ADJACENT PROPERTIES. 3. THE CONTRACTOR SHALL SEED ALL DISTURBED AREAS WITH LOW MAINTENANCE NATIVE GRASS AND COVER WITH APPROVED STRAW. 4. CONTRACTOR SHALL PROVIDE ALL REQUIRED EROSION CONTROL TECHNIQUES AND BEST MANAGEMENT PRACTICES PER LOCAL AND AND STATE REQUIREMENTS AS APPLICABLE. 5. NORTH ARROW SHOWN ON PLANS REFERS TO TRUE NORTH. CONTRACTOR SHALL VERIFY NORTH AND INFORM ARCHITECT/ENGINEER OF ANY DISCREPANCY BEFORE STARTING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR MODIFYING THE RAYCAP INSTALL AT GRADE LEVEL TO ACCOMODATE THE QUANTITY OF RRU'S. THE CONTRACTOR MUST FIELD VERIFY ALL MEASUREMENTS AND FIELD CONDITIONS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL FLORIDA 811 ONE CALL - DIAL 811 CALL 3 WORKING DAYS BEFORE YOU DIG 1-BOD-6384097 NOTE • PROPOSED 700/B14-4478 TO BE INSTALLED AT GROUND LOCATION (1 PER SECTOR, 3 TOTAL) • PROPOSED DIPLEXERS TO BE INSTALLED AT GROUND LOCATION (2 PER SECTOR, 6 TOTAL) EXISTING AT&T WAVEGUIDE BRIDGE EXISTING AT&T GPS ANTENNA- (TYP. OF 2 TOTAL) EXISTING AT&T CABLE ALONG EXISTING WAVEGUIDE BRIDGE ITS ♦ i EXISTING MULTI -METER ♦ � UTILITY FRAME A/C EXISTING GRAVELED AREA EXISTING EXISTING AT&T HANDHOLE (TYP.) EQUIPMENT SHELTER ♦\'= EXISTING TELCO PED TYP. OF 2 �( f♦♦.EQUIPMENT "!.♦ `trV�� o 'IrY h� Y'♦a� /.1rYYLIY��. EXISTING UTILITY � � EXISTING ABANDONED EXISTING CONCRETE PAD - BUILDING EXISTING I _ _ ., GRAVELED AREA - - ..___ SITE PLAN G, SCALE:,^=10' 12' WIDE GATE EXISTING SPRINT TELCO & METER ON CONCRETE POST . EroSL�TSTI NG SPR^NTCQEIIdEFAV®R WAVEGUIDE (TYP. OF 4) VERIZON GEN. EXISTING VERIZON WIRELESS EQUIPMENT SHELTER EXISTING UTILITY H-FRAME EXISTING 6' HIGH CHAIN -LINK FENCE (TYP.) fREV I DATE I DESCRIPTION 1 ��isavcE>.�axAOL•IY,alim�,T� IUS♦ ENG PROJECT NO.: 12190001-11 1 ML 1 FN J at&t 8601 W SUNRISE BLVD PLANTATION, FL 33322 CROWN CCCASTLE 6420 CONGRESS AVE SUITE 2000 BOCA RATON, FL 33487 PREPARED BY: �IENGINEERING MIS CYPRESS RIDGE BLVD. SUITE 110 WESLEY CHAPEL, R 33544 (813) 994-0365 R C0A #31705 4 e Y N0 72513 y ® TJ! ''0%0RIV;r� >olOBp'oNA' FEBRUARY 04, 2019 MARC P. MAIER, PE FL PROFESSIONAL ENGINEER LIC. N 72513 WFTPIERCE FA #zooBoSot CC BU# 813812 8701 ORANGE AVE FT PIERCE, FL 34945 SITE PLAN C-1 V NOTES: 1. A STRUCTURAL ANALYSIS SHALL BE PERFORMED BY THE OWNER'S AGENT TO CERTIFY THAT THE EXISTING/PROPOSED COMMUNICATION STRUCTURE AND COMPONENTS ARE STRUCTURALLY ADEQUATE TO SUPPORT ALL EXISTING AND PROPOSED ANTENNAS, COAXIAL CABLES AND OTHER APPURTENANCES. THE OWNER'S AGENT SHALL FURNISH A CERTIFICATION LETTER SEALED BY A REGISTERED PROFESSIONAL ENGINEER STATING THAT THIS STRUCTURAL ANALYSIS WAS PREPARED IN ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS. ' 2. IF ANY WORK IS PERFORMED AT THIS SITE THAT REQUIRES THE SITE TO BE OFF AIR OR TURNED DOWN, THE SWITCH IS TO BE NOTIFIED 48 HOURS PRIOR TO CONSTRUCTION VIA NCR/CTS. 3. INSTALLATION SHALL BE CONDUCTED BY FIELD CREWS EXPERIENCED IN THE ASSEMBLY AND ERECTION OF RADIO ANTENNAS, TRANSMISSION LINES, AND SUPPORT STRUCTURES. ANTENNA WORK TO BE INSTALLED PER THE REQUIREMENTS OF THE TOWER MANUFACTURER'S SPECIFICATION. 4. ANTENNA AND MOUNT DESIGN MUST COMPLY WITH TIA-EIA-222-G AND ALL LOCAL CODES. 5. CONTRACTOR TO PROVIDE THE PROPER COAX JUMPER SUPPORT ATTACHMENTS TO THE TOWER AND ANTENNA MOUNT. 1. REFER TO RFDS FOR ADDITIONAL INFO. 2. ADJUST ANTENNA MOUNTS AS REQUIRED TO ACHIEVE THE AZIMUTH SPECIFIED AND LIMIT RF SHADOWING 3. UNLESS NOTED OTHERWISE THE CONTRACTOR MUST PROVIDE ALL MATERIAL NECESSARY. 4. CONTRACTOR TO RETURN ALL EXISTING ANTENNAS BEING REMOVED TO AT&T. CONTRACTOR IS RESPONSIBLE FOR MODIFYING THE RAYCAP INSTALLED ON THE TOWER TO ACCOMMODATE THE QUANTITY OF RRU'S. THE CONTRACTOR MUST FIELD VERIFY ALL MEASUREMENTS AND FIELD CONDITIONS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. EXISTING AT&T CABLES ROUTED UP THE TOWER PER STRUCTURAL ANALYSIS. EXISTING SELF SUPPORT TOWER EXISTING AT&T EQUIPMENT SHELTER TOP OF TOWER ELEV. = 250'-0" AGL OTHER CARRIERS OMITTED FROM TOWER TO PROVIDE CLARITY q OF EXISTING & PROPOSED AT&T ANTENNAS ELEV. = 146'-0- AGL C1 TOWER ELEVATION 5-4 SCALE: N.T.S. EXISTING ANTENNA IN POSITIONS #1 TO REMAIN (ALPHA & GAMMA SECTOR, 2 TOTAL) EXISTING RRUS-32 ON BACK TO BACK RRU MOUNT IN POSITION #1 TO REMAIN (1 PER SECTOR, 3 TOTAL) EXISTING ANTENNA IN POSITIONS #3 & #4 TO REMAIN (ALPHA & GAMMA SECTOR, 4 TOTAL) EXISTING RRUS-11 & RRUS-32 B2 ON BACK TO BACK RRU MOUNT IN POSITION #3 TO BE REPLACED (2 PER SECTOR, 6 TOTAL) EXISTING RAYCAP SURGE PROTECTION BOX MODEL #DC6-48-60-18-8F & #DC6-48-60-18-8C TO REMAIN (3 TOTAL) EXISTING ANTENNA IN POSITIONS #1 & #4 TO REMAIN (BETA SECTOR, 2 TOTAL) EXISTING ANTENNA IN POSITIONS #3 TO BE REPLACED (BETA SECTOR, 1 TOTAL) BE7� n EXI: STING ANTENNA CONFIGURATION DETAIL S•t SCALE1 =8' ,A . CONTRACTOR TO ENSURE MINIMUM OF 36' EDGE TO EDGE SEPARATION BETWEEN THE 700 812, B17, B29 NOTESA AND 700 B14 ANTENNAS PER SECTOR AND THE �_ ANTENNA BACKPLANES OF SAME ON DIFFERENT FACE'S REFER TO RFDS FOR ADDITIONAL INFO. n (ADJACENT SECTORS ON SAME RAD CENTER) Al REMAINDER OF ANTENNAS TO BE EQUALLY SPACED NOTE: ro PROPOSED 850/B14-4478 TO BE INSTALLED AT GROUND LOCATION (1 PER SECTOR, 3 TOTAL) PROPOSED DIPLEXERS TO BE INSTALLED AT GROUND LOCATION (2 PER SECTOR, 6 TOTAL) 146'-0' AGL SENOR j IGpMV`F G3 Pti' INSTALL PROPOSED B5/B12-4449 ON BACK TO BACK RRU MOUNT IN POSITION #3 (1 RRU PER SECTOR, 3 TOTAL) INSTALL PROPOSED B2/B66A-8843 ON BACK TO BACK RRU MOUNT IN POSITION #4 (1 RRU PER SECTOR, 3 TOTAL) INSTALL PROPOSED ANTENNA IN POSITION #3 (BETA SECTOR, 1 TOTAL) Sf�OR 2 TTO' PROPOSED ANTENNA CONFIGURATION DETAIL 5-1 SCALE: 1=8' REV DATE DESCRIPTION A 1/29/19 PRELIMINARY CO. REV X 0 2/4/19 REV 0 CDs ISSUED USA END PROTECT NO.: 12190001-11 DRAWN 8Y: CHECKED NY: ML FN e) at&t 8601 W SUNRISE BLVD PLANTATION, FL 33322 CC CROWN CASTLE 6420 CONGRESS AVE SUITE 2000 BOCA RATON. FL 33487 PREPARED BY: ® ENGINEERING 2818 CYPRESS RIDGE BLVD. SUNS 110 WESLEY CHAPEL, FL 33544 (813) 994-0365 FL COA 031705 �r ' [vo 72513 ara a IVAL Wc` Rao =EBRUARV ,, MARC P. MAIER, PE FL PROFESSIONAL ENGINEER LIC. # 72513 WFTPIERCE FA #10080502 CC BU# 813812 8701 ORANGE AVE FT PIERCE, FL 34945 SHEET DESCRIPTON TOWER ELEVATION AND ANTENNA ORIENTATION SHEET NUMBER S-1 C 20.0- n KATNREIN - 80010965 K 8.2 SGpLE: N.T.8. MISCELLANEOUS MATERIALS SCHEDULE DESCRIPTION MODEL NUMBER QUANTITY SNAP -IN RANGER TH496-DG114 - HANGEi ADAPTER GROMMET CX608-RA0711 - HOISRNG GRIP CX051-HG38PL - HOISTNG GRIP CX06-HC12PL - GROUNDING KT - - FIBER OR DC BUNDLE SNAP IN HANGER ROSENBERGER PART NO. TH496—DC114 OR EQUIVALENT HANGER ADAPTER GROMMET — ROSENBFRGER PART NO. CX608—HAOT20 OR EQUIVALENT DOUBLE CLAMP NOTES: 1. REFER TO JSA DOCUMENTS FOR EXACT CAB[ NUMBER AND MANUFACTURER SPECOICANONS FOR PROPER GROMMETS AND HANGER TO SUPPORT THE FIBER AND DC CABLE BUNDLES. 2. REFER TO STRUCTURAL ANALYSIS FOR EXACT CABLE ROUTING AND MOUNTING CONFIGURATION. FIBER BUNDLE HANGER ADAPTER GROM ET — ROSE7IBERGER PART NO. CX608—HAD711 OR EQUIVALENT SUM IN HANGER ROSENBEGER PART NO. TH496—DC114 OR EOAVAUNT SNAP IN HANGER ANTENNA TILT 'ROADED W/ PIPE 'ROWDED W/ AT&T PIPE IROVIDED W/ @ANTENNA MOUNTING DETAIL 8-3 BOLE: N.T.3. KEYN07E LEGEND: 1. SECTOR GROUND BAR 2 COUECWR GROUND BAR. 3. NEW ANIEIM 4. SINGLE PAIR FIBER & DC POWER. 5. JUMPER CABLE. 1/2- (1YP). 6. PIPE MOUNT. 7. DC POWER & FIBER TO RAYCAP UNIT. B. REMOTE RADIO HEAD (Oil{) (IF APPUCABLI7. 9. DC6 RAYCAP SURGE SUPPRESSOR (IF APPUGABLE). 12 SDUD COPPER TINNED IN NMLT (NON—NETAUC LIQUID TIGHT) (TIP) 12 SOLID COPPER TINNED IN NMLT (NON—METAUC LIQUID 71GKO (TYP) 2 1 1 12 SOLID COPPER TINNED PP ((TYNOPN' METRIC LIQUID TOM 1. UfWZE ID SUNG AT&T (ROUND BANS AND GROUNDDNG. 2 ADD GROUND BARS IF THERE ARE INSUFFICIENT LUG POSITIONS. 3. REFERENCE AT&T BONDING & GROUNDDIG PRACTICE TP76416. REV DATE DESCRIPTION A 1/29/19 PREUYINPXf CDs REV 'A' 0 1 2/4/19 1 REV 0 COe ISSUFO IUSA ENO PROJECT NG: 12190001-11 1 \ ML I FN / at&t 8601 W SUNRISE BLVD PLANTATION, FL 33322 CCROWN CASTILE CSTLE 6420 CONGRESS AVE SUITE 2000 BOCA RATON. FL 33487 PREPARED BY: IS ENGINEERING 2818 CYPRESS RIDGE BLVD. SURE 110 WESLEY CHAPEL FL 33544 (813) 994-0365 FL ODA #31705 E No 72513 ao AT OF '�/86111 A16L\\` FEBRUARY 04, 2019 MARC P. MAIER, PE FL PROFESSIONAL ENGINEER UC. # 72513 WFTPIERCE FA #ioosoSot CC BU# 813812 8701 ORANGE AVE F( PIERCE, FL 34945 MISC. DETAILS %IEET L7 n HANGER ADAPTER GROMMET DETAILS 6-2 SCALE: N.TS. @6CALE: N.TS. NTENNA GROUNDING SCHEMATIC S-2 c ERICSSON RRUS-1914 4478 -DIMENSIONS (H x W x D): 16.5' x 13.4' x 7.7' (INCLUDES SUNSHIELD) -WEIGHT: 59.9 LES -CLIMATE -40'C TO +55'C (SELF CONVECTION SILENT, NO FANS, IP55) -POWER CONSUMPTION: 80 WATTS (TYP.) N4 RRUS I:AN oNLi BE PAINTED ON SOLAR SHIELD. n RR u14 4478 DETAIL 53 SCALE: N.T.S. ERICSSON RR - 4 R B66A -DIMENSIONS (H x W x D): 14.96' x 13.19" x 11.1' (INCLUDES SUNSHIELD) -WEIGHT: 75 LDS -CLIMATE: IP65, -4G'C TO +55'C -48 VDC 3 WIRE (2 DC POWER PORTS OF 20A) -32OW OF TOTAL POWER WITH 3 CONFIGURATIONS NOTE: RRUS CAN 4N PAINTED ON S @ map RUS 8843 B2/B66A DETAIL 5-3 SCALE: N.TS. ERICSSON 4449 B5/B12 -DIMENSIONS (H x W x D): 14.96' x 13.19' x 10.43" (INCLUDES SUNSHIELD) -WEIGHT: 73 LBS -CLIMATE: -4YC TO +59C (SELF CONVECTION SILENT, FANS OPT., IP65) -POWER CONSUMPTION: 80 WATTS (TYP.) NOTE: RRUS CAN PAINTED ON SOLAR SHIELD. /1 RRUS 4449 B5/612 DETAIL 9-x S9ALE: N.TS. w ooa�000� � W 0 OQ, awuevmov � o LMIRDAINGUE 1 0 PFOULKi I, oomi. O MB EARTH @K=S DBC0061 F1 V51-1 9J BCALE: N.T.S. IRAN RRU RRU MAST PIPE 1 RRU SUPPORT KIT KK 1250461/1 ROVED EQUAL) 'S REQUIRING A2 SUPPORT T #SXK 1091946/1 & /2 ROVED EQUAL) NOTE: DETAIL IS DIAGRAMMATIC. CONTRACTOR TO INSTALL RRU'S ON RRU MOUNT BEST SUITED FOR ANTENNA CONFIGURATION. BACK VIEW ANTENNA ANTENNA MAST PIPE ERICSSON RRU SUPPORT KIT PART #SXK 1250461/1 (OR APPROVED EQUAL) FOR RRU'S REQUIRING A2 SUPPORT USE PART #SXK 1091946/1 & /2 (OR APPROVED EQUAL) NOTE: DETAIL IS DIAGRAMMATIC. CONTRACTOR TO INSTALL RRU'S ON RRU MOUNT BEST SUITED FOR ANTENNA CONFIGURATION. SECTION A n RRU OUNTING DETAIL 53 SCALE: N.TS.M REV I OATS I DESCRIPTION I OWE- Na•I U54 PROJECT GMG . N0.:12190001-11 DRAWN tiY: CHECKED EY: MIL M at&t 8601 W SUNRISE BLVD PLANTATION, FL 33322 CCCROWN v CASTLE 6420 CONGRESS AVE SUITE 2000 BOCA RATON, FL 33487 PREPARED BY: ®IENGINEERING 2818 CYPRESS RIDGE BLVD. sun 110 WESTEI' CHAPEL FL 3354 9a�e .� P. 4 l � _ a � � TATE OF: m� 'si..ci :ORiV1 =EBRUARY'M! 2019 MARC P. MAIER, PE FL PROFESSIONAL ENGINEER UC.4 72513 WFTPIERCE FA #ioo8o5oz CC RU# 8113812 8701 ORANGE AVE FT PIERCE, FL 34945 SHEET DESCRIPTION MISC. DETAILS S-3 OC / FIBER DEMARCATION BOX avcaPDOReERDEmwunDN BOX cABLEs NOTES M=G 1®GM MODE CITY MODE SItF OlY PER LFNGM NNE 14ST 146'U I DC648NJ88F 1 DC646011SBC 1 2 ROSENBERGEA ]eI PAIR RBERIILIWX -W AWGONNEDMPPFR CONDLCIORS 3/e` ;14° 3 6 200U -3kTU ANTENNA AND COAX SCHEDULE AMFNRAS CABLES RRu A2 DIPJEJE3i MTER TMA PAD ANTE7INA APPROXIMATE OONINDIT 1FNG COLOR SECTOR AZ [EN16t MAN: MODE NICE, TWR GRND qTY) ANTFNNASPE6 9EC MECH MODEL SRE DN (OFT) LINE I CODE MODEL ( MODEL(CITY)MODEL AIPNA JAI) 3W lw-w ANDREW SBNHH-1D8•H 1 WTL7zW' .r.D4.r _ 1-5/8` 2 300?-0• 3RED ROSENMGERFIBERIIWPM(DOSTORRU) 3/9' 1 LRO• 3RED RRUS3] ROSENBERGERSINGLEPNRMCABLE(DOSTORRU) TAT 1 15-01 IRED - ALPHA RRU l/r COA%JU ER MANTENNA 1/r - 6 - W-W - IRM . ALPM(M) 3W I49-V ANDREW SBNHH-IDHSS I H=7L9•z W=lLB`z D-7.r - - - - - - ROSENBERGERFIBERJUNIPER(D06TORRU) 31w 2 W-01 3RED BVBz3 1 ROSENURGERSINGLL PMRDC CAM(DC6TO RRU) 7/16' 2 15'T 3RED - - °COA%JLWTER RRUTO ANTENNA) 11r 6 la-w 3RED AIPHA(M) 3W 14ST ANDREW SBNTM-1D85B 3 lk7LYzW�1.9"zD=]3' 1-Ve• 2 200T 4RFD _ _ ROSFNBER6ERFIBBIIUMPER(ODi1ONRU) 3/6' 2 ISU' ORED •BI440R I - DBausu1VR-1 _ 2 ROSENSERGHt9NGlEPAIRMCABIE(MTORRUI 7/361 2 I9-0' 4RE0 ]/r COMIUMPER RRUMANIEN 2/r 1 4 IVU' 4RED _ BETA(8) I1T LAG-V %MW ET-I(-UMW.14. MiR-AT 1 H=TCz W=lrzD= r _ I -Val 2 2(ID-W SBLUE ROSENBFRGER FIBERIUMPER(DC6T0 RRll) Sir 1 ]5'T 1BLVE ROSENBERGERSINGLEPNRDCC M(DOSTORRU) 7/IC 1 35'-0" 18LUE IMCOAXJUAPER RRUTOANTENNA 1/r 6 WN 18UE BETA(BI) SETA(M) 110' W-0' %ATHREN EmVMSSK 1 N=]S.TZW=2®•z059' - - - - - - ROSE7JBERGERFlBBINAPEI(DTSIORRU) wr 2 19-W 3811E 8VM2J4® 1 ROSENBFRGEi5U1GLEPIUROCCABIF(OC6lDRRU1 1/16• 2 1ST 38UE ]/r 8 10.0' 36LE BETA(84) 110' 146-LP AVN2 EF-%-UM6&1465]AIR-AT 1 H=T2°zW=12°z D�.3' - �A%IUMPERIRRUTOAN1BiN11) 7/e° i 20DT 48UF ROSENMRGERFIBERIUMPER(D MRRU) 3JB' 2 ISU' 4BLUE -81 4 1 - DMO)OSUIVRA - 2 - - ROSENBERGERSINGIEPAIRMCAME(DOSTORXU) 7/2r 2 15'T 4BUIE EZWAAISML3 1 - Vr CO"JUMVERIRRUMANTENNA) 1/r 4 IOU' 4BLUE GAMMA(GI) 229 14ST ANDREW SBNHH-IDSSB 1- H=7LV'z W-11.9'zD-71° _ _ _ 1-5/8° 2 2W-0- IGREEN ROSENBRGER FIBER 1l1MPFR(IXSTO RRU) 3/H• 1 15-V IGREEN ROSENBRGERSINGLLPAIRDCC M(DC6TORRU) 71W 1 JST 1GRFDq GAM3.1A M) I/r COA%IUNRER RRUTOANTENNA 1/2' 6 W-W IGREEN GANO4A(0) 224 g670 ANDREW SBNH141Dfl5H 1 ROSEJBERGERFIBERJUTAER(D STORRE) 3/B° 2 19-01 3GREEN BS1812d 1 - ROSMSERGERSINGIEPAIRDCCAM(DC6TORRU) 711V 2 ISO 3GREEN - - - GANOAA(G4) 213' 146'T ANDREW SBNXIFIO® 3 X=]L9'zW=1L9'zR7.1' 1MCCA%JLMPER(RRUMANTENNA) 1/r 6 I0T 3GREEN _ _ IDF7_x 7/r 2 IIWT 4GREEN _ _ _ _ _ ROSENBFRGERFIBERIUATPER(GO;MRRU) 3AT' 2 ISU' 4GREEN '83441/8 1 - DSCW6MM-1 - 2 - - ROSENBERGERSINGIEPAIRMCABIE(DOSTORRU) 71W 2 15U' 4GRSEN Bt/B6W-8B43 1 - _ _ 1/r COAXJIIMPER(RRUTOANTENNA) ALL-5/8•COA%(ACRVEI - IM 1 4 1 10-0' 4GREEN TOTAL 9 'ANTENNA AND COM INFORMATION PROVIDED FROMTHE LTE SC UMVLDIDATM 12/2R/18 12 24E7T 1T7M1 12 0 IOTAL 0 6 TOTAL O ALl-V8' COA%(WACLLVE) *COMPACT MVEM"UINFOWIIN(EIENTPNORMMNSIRUCRON. ALFl89iNAPER 15 225T •M"UNG06 APPROXIMAIEANDMI MVFRIRMPAORTOCONSIRUCEJON. •REOPOSMSI"47BINSTA1Jl3)ATGMMDLPV (INCWDEDM1 AL1 TOTALMAIMPS1 IS 229T •ALLCOM5H 11ECOLORWDEDATTOPAN BOTIOMIUMPERANDATTOPOFTOWEL AL3%r NMPERS - 6p SOY-0` BOTTUMOFTOWEI,ANDINSIDESHELTERON MAIN COAX ALS/IE RET CA813 3 60DT • FACN MAIN COAXSNAI I HAVF MARMI(1N ...... — ATME PORTANDATTNEANTENNA C1 ANTENNA & COAX SCHEDULE N- SCALE: N.T.S. REV OATS OEISCAPIION A 1/29/19 PRELIMINARY CO. REV A' 0 2/4/19 REV 0 CDs ISSUED USA ENO PROJECT NO.: 12190001-11 DE En: cxEDXm BY: MI. FN 0 at&t 8601 W SUNRISE BLVD PLANTATION, FL 33322 CROWN v CASTLE 6420 CONGRESS AVE SUITE 2000 BOCA RATON. FL 33487 PREPARED BY: ®IENGINEERING 2818 CYPRESS RIDGE BLVD. SUITE 110 WM EY CHAPEL FL 33544 No 72513 -e* 14 T IE OF R% �'Yr�3e`Z019 MARL P. MAIER, PE FL PROFESSIONAL ENGINEER UC. # 72513 WFTPIERCE FA noo8o5o2 CC BU# 83138-12 8701 ORANGE AVE FT PIERCE, FL 34945 ANTENNA SCHEDULE SHEET NUMBER AN-1 -o `E E a Ln 0 N z 0 .`o Ln a 3 vl x V X ~4 I I U U V wl it d W I File: T:\00-2019 PROJECTS\01—Crown\Crown — AT&T LTE\WTFPIECE_7 0 9F®fy27r Invalid reference 0 0 N M I N N O O O_ wl it a 3 J 4d File: T:\00-2019 PROJECTS\01—Crown\Crown — AT&T LTE\WTFPIECE_10080502_81 z ®®to32& invalid reference w ONE -LINE DIAGRAMS N E-1 SCALE: N.T.S. ELECTRICAL SCOPE OF WORK: INSTALLATION OF (3) NEW 814 4478 RADIOS INSIDE THE EQUIPMENT SHELTER ON THE GROUND. THESE RADIOS WILL REQUIRE A NEW DC POWER CABLE PLUGGED FROM THE RADIOS TO THE EXISTING RAYCAP SURGE PROTECTOR INSIDE THE SHELTER. NO NEW A/C ELECTRICAL UPGRADES ARE PROPOSED. ERICSSON RRU BREAI(ER REQUIREMENTS 56 MIC0N RADIO SIZE SRIAKER TECHNOLOGY RRUS 32 B66 30 AMP An (2100) RRUS 32 00 20 AMP =S (2300) RRUS 32 82 30 AMP Pm (1900) RRUS 11 25 AMP VMIJJS BeA)S IWO [0121 , Me [0). 1900 [MI. 21M [B43 RMS12 + A2 25 AMP VMW BN105 ( 650 [01, 19M [021, 2100 (MI) RRU 4415 025 25 AMP 19M RRU 4426 B66 30 AMP 2100 RRU 4478 B14 25 AMP 700 RRU 4478 E5 25 AMP 850 RRUS E2 B29 25 AMP 700 RRUS 4449 35/a12 2x25 AMP 700/650 RRUS 6843 B2/866 2x30 AMP 1900/2100 '19wrig... INCH 10 AMP 850 RRUS 2205 846 10 AMP 5 GH 4 2 5 3 6 ---- ---- — OOMhz RRH ---- ---- — AWS RRH 7 u�l LTE — — — DIGITAL — UNIT B74 RRH 1. —48V DC POWER PLANT. CONTRACTOR TO VERIFY CORRECT BREAKER SIZE IS INSTALLED FOF EACH RRU PER CHART. 2. (1) RACK MOUNTED RAYCAP DC SURGE PROTECTOR (DC6-48-60—RM). 3. RAYCAP FIBER AND DC DISTRIBUTION UNIT (OC6-48-60-18-8F) TOWER MOUNTED. 4. #8 AWG SHIELDED CONDUCTORS (WR—VG82ST—BRDA). &Iri1RR(0WE (2) 6—CONDUCTOR #8 AWG BUNDLES FOR DC POWER FROM RACK MOUNTED RAYCAP SURGE PROTECTION UNIT TO THE RAYCAP FIBER AND DISTRIBUTION UNIT ON TOWER. 6. DC CABLE ROUTED TO RRH UNITS. 7. #12 AWG SHIELDED CONDUCTORS (WR—VG122ST—BRDA). n TYPICAL DC RISER DIAGRAM E•1 SCALE: N.TS. REV DATE DESCRIPTION A 1/29/19 PRELIMINARY Co. REV •A' 0 2/4/19 REV 0 CDs ISSUED USA ENO PROJECT NO.: 12190001-11 DRAWN BY: CHECKED EIY: ML FN at&t 8601 W SUNRISE BLVD PLANTATION, FL 33322 CCCROWN v STLE 6420 CONGRESS AVE SUITE 2000 BOCA RATON. FL 33487 PREPARED BY: ® ENGINEERING 2818 CYPRESS RIDGE BLVD. SUITE 110 WESLEY CHAPEL. FL 3350 (813) 994-0365 FL ODA #31705 P. No 72513 %Y e r R 1 Q.•_ -EBRUARY 04, 2019 MARC P. MAIER, PE FL PROFESSIONAL ENGINEER LTC. a 72513 VV"PIERCE FA noo8om CC BU# 813812 8701 ORANGE AVE F! PIERCE, FL 34945 iY:Na�gb?!:IIMIPIa ANTENNA ONE -LINE DIAGRAM E-1 l4Vda_p>,5y ALPHAd MMA ONE -LINE DIAGRAMS E-T SCALE N.T.S.. rl -`"4 v MAR 0 5 20N Lucie County, Permitting z ELECTRICAL SCOPE OF WORK: INSTALLATION OF (3) NEW Bl4 4478 RADIOS INSIDE THE. EQUIPMENT SHELTER ON THE GROUND. THESE RADIOS WILL REQUIRE A NEW DC POWER CABLE PLUGGED FROM THE RADIOS TO THE EXISTING RAYCAP SURGE PROTECTOR INSIDE THE SHELTER. NO NEW A/C ELECTRICAL UPGRADES ARE -PROPOSED. - FAICSSON RRII BREAKEA RE7151REMENT9 - '-' .. .. EPoCSSON RADID'_ SIZE EMEAKER _... .., -. _ .. .. TECHNOLOGY - RRUS 32 866 30 AMP_ AWS (2100) - TM,32'100 20 AMP WCS.(2300) . MUS 32,82 301 0 PCS (1900) •' Ms 11 - 23 AMP YM0 M WDS D00 [612) . 350 [fish I= JM[ 2100 (84D. WM12 4'A2 25- AW YAM01N WO ( 650 [l51 1960 [9112100 1s) _ - RW4415M. 25-ANP" 1900._.._ ..-. - RRU 4426 B66 3D,.W 21DO _ RU-"M 814 _ 25 AYP 100 - RRU 447R 65 . 25 W am mu-E2.8!!8 25 AMP 700 - - uL,S-4419 85/812- Z n AID TDO/650 ' RiVs 0641',B2/866 b30 AMP 1900/2100 RRU5.220] 6g 10'AYP 650 RNUS 2205,B46' 10-MP 5 Gft - - KMOTELEGE .. 1. EACH RR ('PER CHART. CONDNOfOR TO VERIFY CORRECT BREAKER SIZE IS UlSTALLED FOR EACH RRU PER CW1Rf.- 2.. (1) RACK MOUNTED. RAYCAP DC SURGE PROTECTOR..(OC6-48-60-RM). 3. RAYCAP'FIBER AND DODISTRIBUTIONUNIT (OC6-48-60-18-6F) TOWER MOUNTED. 4. /8.AWG SHEIDED CONDUCTORS (WTI-VG82ST-BRDAV;- 5. PR(MDE (2) 6-CONDUCTOR #8 AWG BUNDLES FOR:OC. POWER. FROM RACK MOUNTED - RAYCAP SURGE PROTECTION UNrT TO THE RAYCAR FIBER -AND DISTRIBUTION UNIT ON TOWER 6. DC. CABLE ROUTED. TO RRH UNITS., - - 7. /12 AwO sNpDED CONDUCTORS (WTI VGi22ST-BRDA); . ATYPICAL. DC RISER DIAGRAM &2 SCALE: N.T.S. - I LV DALE PE5CRIP119N. - 77A 1/29/19 .PREUMKkW CDa REV A7 0 1. - 2 4 S 6 7 USA' ENC PRwwr NO. 12190001'-11 DRAWN BY.. ,;CHECKED Sr.- . ML'. -EN .. at&t 8601, IN SUNRISE BLHD PLANTATION, FL 33322 �CROWN ,CASTL-'E 6420 CONGRESS AVE SUITE 2000- - BOCA RATON. FL-33487 G�USA' ENGINEE ' RING 2BI8 CYPRESS RNGE BLVD. - ilVo- 7LSj3: S 3 8'r-►1TE, OF -0 3 I;ID "PA IC P. NIAIER4 PE ANAL ENGINEER TIC, R 72513 74 TPWACE - FA #166SO502 CC B.U# Sir 38i2 8761 ORANGE AVE Ff PIERCE, FL 34945 ' SHEET PESCRWRON " ANTENNA J6,'dE-LINE DIAGRAM E=1 0 E E M N 0 r t� at&t SCANNED BY St. Lucie County WFTPIERCE FA # 10080502 CROWN CASTLE BU# 813812 CROWN APPLICATION #1482523 8701 ORANGE AVENUE FORT PIERCE, FL 34945 TOWER UPGRADE - 4C/5C/6C/4TX4RX/4TX4RX PACE JOB #: MRSFLO16371 LOCATION MAP APPROVALS DESIGN CRITERIA INDEX OF DRAWINGS - FLORIDAETA/ BUILDING CODE ( PER EDITION) 2017 �--' O yl=a�. ASCEU7 0 222-G (ALLOWED PER EXEMPTION $5 OF 1609.1.1) N�' DESCRIPTION N0. ba�sasAr' q PROPERTY OWNER DATE VULT = 157 MPH (ULTIMATE 3 SECOND GUST) T-1 TITLE SHEET VASD = 122 MPH (NOMINAL 3 SECOND GUST) R RF ENGINEER DATE RISK CATEGORY = II GN-1 GENERAL NOTES, ABBREVIATIONS EXPOSURE = C ARCHITECTURAL / CIVIL PLANS IMPORTANCE FACTOR= 1.0 CONSTRUCTION DATE - NATIONAL ELECTRICAL CODE, 2014 EDITION (NFPA 70-2014) C-1 SITE PLAN `may u 9 - FLORIDA FIRE PREVENTION CODE (2015) STRUCTURAL PLANS ,�, BDE LOCARo SITE ACQUISITION DATE — CONTRACTOR TO CONFIRM THAT THE SITE IS COMPLIANT WITH Dees:Prz.^6� RF WARNING SIGNAGE & EMERGENCY SIGNAGE AS REQUIRED BY S-1 TOWER ELEVATION AND ANTENNA ORIENTATION I ZONING DATE THE FEDERAL GUIDEUNES CONTAINED WITH DIET 65 BULLETIN & AS PER AT&T GUIDELINES S-2 MISCELLANEOUS DETAILS NETWORK DATE CONSTRUCTION NOTES S-3 MISCELLANEOUS DETAILS OPERATIONS DATE 1. CONTRACTOR SI411L VBLFY ALL PLANS AND EXISTING DIMENSIONS AND ANTENNA PLANS COMMONS ON THE JOB SITE AND SH4. IMMEDIATELY NOTIFY THE AN-1 ANTENNA SCHEDULE CONTRACTOR DATE ENGINEER IN WRITING OF AM DISCREPANCIES BEFORE PROCEEDING WITH THE WOW OR BE FESPMG13 E FOR SAME. ELECTRICAL PLANS 2 SITE FEE OR AC EC S3 CONTRACT EQUIT AT TS. IMPLEMENTATION PM OR E-1 ANTENNA RISER DIAGRAM OE VICINITY MAP PROJECT SUMMARY ' THIS WORK.- OFTHE, (3) REPLAATIONCEMENT EME TOWER 1WNd(: (1) NEW ANTETINAS. (3) REPIACD,fNT B5/612-4449, (3) REPI/MENT B2AM-8893, AND ALL ASSOCIATED WOFK t (7 III SITE NAME: WFTPIERCE GROUND WUTGC: (3) OJT B14-4178. (6 ) NEW DIF E)M & ALL ASSOCIATED 15IXLC 2 FA SITE NUMBER: 10080502 � F 4. M40M WILL BE OFF AIR FOR 4-7 Mt5 DURING ANIEFAN MOUNT T ea1 aPARCEL' 2311-320-0000-000/4 INSTALLATION. Com,aa RA --a- _ R,'rI, C (� COUNTY: ST LUCIE F N 'W 6 ,toad JURISDICTION: ST LUCIE COUNTY CONTACTS Gf�T ' 7_;. ) !. 1[ SITE COORDINATES: N 27.4455944' APPLICANT: W 80.41 z79aa• AT&T I B nON �R I 41 SITE TYPE: 4C/5C 6C 4TX4RX 4TX4RX - ^• / / / 8601 W SUNRISE BLVD ^ STRUCTURE TYPE: SELF SUPPORT TOWER PLANTATION. FL 33322 E TOWER HEIGHT: 250'-0" AGL TOWER OWNER: RE R 1 rc s�m� ANTENNA C.L. HEIGHT: 146'-0" AGL CROWN CASTLE S o 6420 CONGRESS AVENUE, SUITE 2000 �r`V• BOCA RATON. FL 33487 _F^, 1 .�...t».r. a ENGINEER:-'- -Pkoc USA ENGINEERING 2818 CYPRESS RIDGE BLVD, SUITE 110 WESLEY CHAPEL,-FL-33544 9ranemaJ CONTACT: MARC P. MAIER, P.E. PHONE: (813) 994-0365 DRIVING DIRECTIONS PROJECT REFERENCES PROJECT INFORMATION DEPM FROM AT&T OFFICE 8601 W. SUNRISE BLVO., PLANTATION, FL 33322 1. Depart SR-838 W / W Sundae Blvd toward! N Pine Island Rd 0.4 mi 1. THESE PLANS WERE COMPLETED PER PREUMINARY/APPROVED 1. THIS IS AN UNMANNED FACILITY AND WILL BE USED FOR THE TRANSMISSION OF RADIO SIGNALS FOR THE PURPOSE OF 2. Tura Hack on SR-838 E / w Sunrise Blvd Pass Mobil/7-0even on the right in 1.0 mi 4.1 m, LTE 5C RFDS ID#: 2591079 V1.00, DATED 01/28/19. PROVIDING PUBUC CELLULAR SERVICE 3. Take ramp left for Ronda s TumpI North toward Orlando Ton road 94.0 mi CONTRACTOR SHALL .REQUEST CURRENT ROS & WORKBOOK 4. At evit 152, take romp right for SRao towam R Pierce / Vera Bch 0.5 ml FROM CONSTRUCTION MANAGER PRIOR TO CONSTRUCTION. 2. AT&T CERTIFIES THAT THIS EQUIPMENT FACILITY WILL BE SERVICED ONLY By AT&T EMPLOYEES AND SUBCONTRACTORS AND 5. Keep straight onto SR-713 / S Kings Hwy Pass Love's Country Store in 2.4 mi 2.4 mi THE WORK ASSOCIATED WITH ANY EQUIPMENT CANNOT BE PERFORMED BY HANDICAPPED PERSONS. THIS FACILITY WILL BE j S. Tura left onto Orange Ave / CR-fie w Love's Count'• Stare on the comer 0.9 m1 FREQUENTED ONLY BY SERVICE PERSONNEL FOR REPAIR PURPOSES ONLY. Aniw at 8701 Orange Avenue Ft Fie,ce FL 34945 V 3. NO POTABLE WATER SUPPLY IS TO BE PROVIDED AT THIS LOCATION. OPYTF[I��T 4. NO WASTEWATER WILL BE GENERATED AT THIS LOCATION. � p 1 / a :s� � 5. NO SOLD WASTE WILL BE GENERATED AT THIS LOCATION. � REV DATE DESCRIPTION A 1/29/19 PREJIJINM CDs REV 'A" 0 2/4/19 REV 0 COB ISSUED USA END PROVECT NO., 12190001-11 DRAWN BY: CNECKED DV: ML FN at&t 8601 W SUNRISE BLVD PLANTATION, FL 33322 CROWN v CASTLE 6420 CONGRESS AVE SUITE 2000 BOCA RATON, FL 33487 I REPARED BY: ®IENGINEERING 2818 CYPRESS RIDGE BLVD. SURE Ito WESLEY CHAPEL FL 33544 (813) 994-0365 FL COA 031705 P. No 72513 o SA' OF -'9D99®B111e1- FEBRUARY 04, 2019 MARC P. MAIER,.PE FL PROFESSIONAL ENGINEER LIC. # 72513 WFTPIERCE FA nooeom CC BU# 83138=2 8701 ORANGE AVE FT PIERCE, FL 34945 TITLE SHEET SHEEP NUMBER T-1 x i GENERAL NOTES: 1. ALL REFERENCES TO OWNER HEREIN SHALL BE CONSTRUED TO MEAN AT&T OR IT'S DESIGNATED REPRESENTATIVE. 2. ALL WORK PRESENTED ON THESE DRAWINGS MUST BE COMPLETED BY THE CONTRACTOR UNLESS NOTED OTHERWISE. THE CONTRACTOR MUST HAVE CONSIDERABLE EXPERIENCE IN PERFORMANCE OF WORK SIMILAR TO THAT DESCRIBED HEREIN. BY ACCEPTANCE OF THIS ASSIGNMENT, THE CONTRACTOR IS ATTESTING THAT HE DOES HAVE SUFFICIENT EXPERIENCE AND ABILITY, THAT HE IS KNOWLEDGEABLE OF THE WORK TO BE PERFORMED AND THAT HE IS PROPERLY LICENSED AND PROPERLY REGISTERED TO DO THIS WORK IN THE STATE AND/OR COUNTY IN WHICH IT IS TO BE PERFORMED. 3. UNLESS SHOWN OR NOTED OTHERWISE ON THE CONTRACT DRAWINGS, OR IN THE SPECIFICATIONS, THE FOLLOWING NOTES SHALL APPLY TO THE MATERIALS LISTED HEREIN, AND TO THE PROCEDURES TO BE USED ON THIS PROJECT. 4. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE TO INSURE THE SAFETY OF THE STRUCTURE AND ITS COMPONENT PARTS DURING ERECTION AND/OR FIELD MODIFICATIONS. THIS INCLUDES, BUT IS NOT LIMITED TO. THE ADDITION OF WHATEVER TEMPORARY BRACING, GUYS OR TIE DOWNS THAT MAY BE NECESSARY. SUCH MATERIAL SHALL BE REMOVED AND SHALL REMAIN THE PROPERTY OF THE CONTRACTOR AFTER THE COMPLETION OF THE PROJECT. 5. ALL DIMENSIONS, ELEVATIONS, AND EXISTING CONDITIONS SHOWN ON THE DRAWINGS SHALL BE FIELD VERIFIED BY THE CONTRACTOR AND THE TESTING AGENCY PRIOR TO BEGINNING ANY MATERIALS ORDERING, FABRICATION OR CONSTRUCTION WORK ON THIS PROJECT. ANY DISCREPANCIES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER AND THE OWNER'S ENGINEER. THE DISCREPANCIES MUST BE RESOLVED BEFORE THE CONTRACTOR IS TO PROCEED WITH THE WORK. THE CONTRACT DOCUMENTS DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. OBSERVATION VISITS TO THE SITE BY THE OWNER AND/OR THE ENGINEER SHALL NOT INCLUDE INSPECTION OF THE PROTECTIVE MEASURES OR THE CONSTRUCTION PROCEDURES. 6. ALL MATERIALS AND EQUIPMENT FURNISHED SHALL BE NEW AND OF GOOD QUALITY, FREE FROM FAULTS AND DEFECTS AND IN CONFORMANCE WITH THE CONTRACT DOCUMENTS. ANY AND ALL SUBSTITUTIONS MUST BE PROPERLY APPROVED AND AUTHORIZED IN WRITING BY THE OWNER AND ENGINEER PRIOR TO INSTALLATION. THE CONTRACTOR SHALL FURNISH SATISFACTORY EVIDENCE AS TO THE KIND AND QUALITY OF THE MATERIALS AND EQUIPMENT BEING SUBSTITUTED. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. THE CONTRACTOR IS RESPONSIBLE FOR INSURING THAT THIS PROJECT AND RELATED WORK COMPLIES WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL SAFETY CODES AND REGULATIONS GOVERNING THIS WORK. B. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE LATEST EDITION OF THE LOCAL BUILDING CODE. 9. ALL PROPOSED CELLULAR EQUIPMENT AND FIXTURES SHALL BE FURNISHED BY OWNER FOR INSTALLATION BY THE CONTRACTOR, UNLESS SPECIFICALLY NOTED OTHERWISE HEREIN. 10. ACCESS TO THE PROPOSED WORK SITE MAY BE RESTRICTED. THE CONTRACTOR SHALL COORDINATE INTENDED CONSTRUCTION ACTIVITY, INCLUDING WORK SCHEDULE AND MATERIALS ACCESS, WITH THE RESIDENT LEASING AGENT FOR APPROVAL 1. STRUCTURAL STEEL SHALL CONFORM TO THE LATEST EDITION OF THE A.I.S.C. SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS- ALLOWABLE STRESS DESIGN AND PLASTIC DESIGN INCLUDING THE COMMENTARY AND THE A.I.S.C. CODE OF STANDARD PRACTICE. 4. ALL COAXIAL CABLE CONNECTORS AND TRANSMITTER EQUIPMENT SHALL BE AS SPECIFIED BY THE OWNER AND IS NOT INCLUDED IN THESE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL FURNISH ALL CONNECTION HARDWARE REQUIRED TO SECURE THE CABLES. CONNECTION HARDWARE SHALL BE GRADE 304 STAINLESS STEEL. 5. ALL REINFORCING STEEL SHALL CONFORM TO ASTM 615 GRADE 60, DEFORMED BILLET STEEL BARS. WELDED WIRE FABRIC REINFORCING SHALL CONFORM TO ASTM A185. 6. THE FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO THE LATEST A.I.S.C. SPECIFICATIONS. 7. ALL CONNECTIONS NOT FULLY DETAILED ON THESE PLANS SHALL BE DETAILED BY THE STEEL FABRICATOR IN ACCORDANCE WITH A.I.S.C. SPECIFICATIONS. 8. HOT -DIP GALVANIZE ITEMS SPECIFIED TO BE ZINC -COATED, AFTER FABRICATION WHERE PRACTICAL. GALVANIZING: ASTM A 123, ASTM, A 153/A 153M OR ASTM A 653/A 653M, G90, AS APPLICABLE. 9. REPAIR DAMAGED SURFACES WITH GALVANIZING REPAIR METHOD AND PAINT CONFORMING TO ASTM A 780 OR BY APPLICATION OF STICK OR THICK PASTE MATERIAL SPECIFICALLY DESIGNED FOR REPAIR OF GALVANIZING. CLEAN AREAS TO BE REPAIRED, AND REMOVE SLAG FROM WELDS. HEAT SURFACES TO WHICH STICK OR PASTE MATERIAL IS APPLIED WITH A TORCH TO A TEMPERATURE SUFFICIENT TO MELT THE METALLICS. IN STICK OR PASTE, SPREAD MOLTEN MATERIAL UNIFORMLY OVER SURFACES TO BE COATED AND WIPE OFF EXCESS MATERIAL. 10. CONTRACTOR SHALL FOLLOW THE MANUFACTURER'S INSTRUCTIONS/SPECIFICATIONS IF NO INFORMATION IS CONTAINED IN THESE PLANS OR IF THE MANUFACTURER'S SPECIFICATIONS ARE STRICTER. PERMITS: 1. CONTRACTOR SHALL SECURE ALL NECESSARY PERMITS FOR THIS PROJECT FROM ALL APPLICABLE GOVERNMENTAL AGENCIES. 2. ANY PERMITS WHICH MUST BE OBTAINED SHALL BE THE CONTRACTOR'S RESPONSIBILITY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ABIDING BY ALL CONDITIONS AND REQUIREMENTS OF THE PERMITS. 3. ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES AND THE ACI 318-14, "BUILDING REQUIREMENTS FOR STRUCTURAL CONCRETE". 4. THE CONTRACTOR SHALL NOTIFY THE APPLICABLE JURISDICTIONAL (STATE, COUNTY OR CITY) ENGINEER 24 HOURS PRIOR TO THE BEGINNING OF CONSTRUCTION. 5. ALL DIMENSIONS SHALL BE VERIFIED WITH THE PLANS (LATEST REVISION) PRIOR TO COMMENCING CONSTRUCTION. NOTIFY THE OWNER IMMEDIATELY IF DISCREPANCIES ARE DISCOVERED. THE CONTRACTOR SHALL HAVE A SET OF APPROVED PLANS AVAILABLE AT THE SITE AT ALL TIMES WHEN WORK IS BEING PERFORMED. A DESIGNATED RESPONSIBLE EMPLOYEE SHALL BE AVAILABLE FOR CONTACT BY GOVERNING AGENCY INSPECTORS. ... i mm 1. ALL THREADED STRUCTURAL FASTENERS FOR ANTENNA SUPPORT ASSEMBLES SHALL CONFORM TO ASTM A307 OR ASTM 36. ALL STRUCTURAL FASTENERS FOR STRUCTURAL STEEL FRAMING SHALL CONFORM TO ASTM A325. FASTENERS SHALL BE 5/8. MIN. DIA. BEARING TYPE CONNECTIONS WITH THREADS EXCLUDED FROM THE PLANE. ALL EXPOSED FASTENERS, NUTS, AND WASHERS SHALL BE GALVANIZED UNLESS OTHERWISE NOTED. ALL ANCHORS INTO CONCRETE SHALL BE STAINLESS STEEL 2. THE CONTRACTOR SHALL FURNISH ALL CONNECTION HARDWARE REQUIRED TO SECURE THE CABLES. CONNECTION HARDWARE SHALL BE STAINLESS STEEL.- 2. STRUCTURAL STEEL PLATES AND SHAPES SHALL CONFORM TO ASTM A36. ALL 3. NORTH ARROW SHOWN ON PLANS REFERS TO TRUE NORTH. CONTRACTOR SHALL STRUCTURAL STEEL PIPES SHALL CONFORM TO ASTM A53 GRADE B. ALL VERIFY NORTH AND NOTIFY CONSULTANT OF ANY DISCREPANCY BEFORE STARTING STRUCTURAL STEEL TUBING SHALL CONFORM TO ASTM A500 GRADE B. ALL CONSTRUCTION. STRUCTURAL STEEL COMPONENTS AND FABRICATED ASSEMBLIES SHALL BE HOT 4. PROVIDE LOCK WASHERS FOR ALL MECHANICAL CONNECTIONS FOR GROUND DIP GALVANIZED AFTER FABRICATION. CONDUCTORS. USE GRADE 304 STAINLESS STEEL HARDWARE THROUGHOUT. 3. WELDING SHALL BE IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY (AWS) 5. THOROUGHLY REMOVE ALL PAINT AND CLEAN ALL DIRT FROM SURFACES D.1.1/D7.1M:2010. STRUCTURAL WELDING CODE -STEEL WELD ELECTRODES SHALL REQUIRING GROUND CONNECTIONS. BE E70XX. 6. MAKE ALL GROUND CONNECTIONS AS SHORT AND DIRECT AS POSSIBLE. AVOID SHARP BENDS. ALL BENDS TO BE A MIN. OF 8" RADIUS. 7. FOR GROUNDING TO BUILDING FRAME AND HATCH PLATE GROUND BARS, USE A TWO -BOLT HOLE NEPA DRILLED CONNECTOR SUCH AS T&B 32007 OR APPROVED EQUAL B. FOR ALL EXTERNAL GROUND CONNECTIONS, CLAMPS AND CADWELDS, APPLY A LIBERAL PROTECTIVE COATING OR AN ANTI -OXIDE COMPOUND SUCH AS 'NO -OXIDE A' BY DEARBORN CHEMICAL COMPANY. 9. REPAIR ALL METAL SURFACES THAT HAVE BEEN CUT OR DAMAGED BY REMOVING ANY EXISTING RUST AND APPLYING COLD GALVANIZATION. 10. ANTENNA CABLE LENGTHS HAVE BEEN DETERMINED BASED ON THESE PLANS. CABLE LENGTHS LISTED ARE APPROXIMATED AND ARE NOT INTENDED TO BE USED FOR FABRICATION. DUE TO FIELD CONDITIONS, ACTUAL CABLE LENGTHS VARY. CONTRACTOR MUST FIELD VERIFY ANTENNA CABLE LENGTHS PRIOR TO ORDER. REV DATE D6CRIPIION A 1/29/19 PRELIMINARY CO. REV -A- 0 2/4/19 REV 0 CO. ISSUED USA ENG PROJECT NO.: 12190001-11 DMWN W. CHECKED BY: ML M 8601 W SUNRISE BLVD PLANTATION, FL 33322 CC CROWN CASTLE 6420 CONGRESS AVE SUITE 2000 BOCA RATON, FL 33487 PREPARED BY: ®IENGINEERING 2818 CYPRESS RIDGE BLVD. sun 110 WESLEY CHAPEL. FL 33544 E IV -- ri�5ym� = NO 72513 i; ohs t o R 1 o p `��C;O goal L�A® eti�a°°e =EBRUA��' 04, 2019 MARC P. MAIER, PE FL PROFESSIONAL ENGINEER LIC. 972513 WFTPIERCE FA #ioosogo2 CC BU# 8313812 8701 ORANGE AVE FT PIERCE, FL 34945 SHEEP DESCWPDON GENERAL NOTES, ABBREVIATIONS SHEEP NUMBER G N-1 6 1. CONTRACTOR TO FILL ANY EXISTING GRAVEL AREAS THAT ARE DISTURBED DURING THE COURSE OF CONSTRUCTION, GRAVEL TO MATCH EXISTING. 2. THE CONTRACTOR TO ENSURE THAT NO DAMAGE OR DEBRIS OCCURS ON THE ADJACENT PROPERTIES. 3. THE CONTRACTOR SHALL SEED ALL DISTURBED AREAS WITH LOW MAINTENANCE NATIVE GRASS AND COVER WITH APPROVED STRAW. 4. CONTRACTOR SHALL PROVIDE ALL REQUIRED EROSION CONTROL TECHNIQUES AND BEST MANAGEMENT PRACTICES PER LOCAL AND AND STATE REQUIREMENTS AS APPLICABLE. 5. NORTH ARROW SHOWN ON PLANS REFERS TO TRUE NORTH. CONTRACTOR SHALL VERIFY NORTH AND INFORM ARCHITECT/ENGINEER OF ANY DISCREPANCY BEFORE STARTING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR MODIFYING THE RAYCAP INSTALL AT GRADE LEVEL TO ACCOMODATE THE QUANTITY OF RRU'S. THE CONTRACTOR MUST FIELD VERIFY ALL MEASUREMENTS AND FIELD CONDITIONS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. ONE CALL - DIAL 811 CALL 3 WORKING DAYS BEFORE YOU DIG 1-800-638-4097 NOTE: • PROPOSED 700/B14-4478 TO BE INSTALLED AT GROUND LOCATION (1 PER SECTOR, 3 TOTAL) • PROPOSED DIPLEXERS TO BE INSTALLED AT GROUND LOCATION (2 PER SECTOR, 6 TOTAL) EXISTING AT&T WAVEGUIDE BRIDGE EXISTING AT&T GPS ANTENNA- (TYP. OF 2 TOTAL) EXISTING AT&T CABLE ALONG EXISTING WAVEGUIDE BRIDGE O ❑ I EXISTING MULTI -METER UTILITY FRAME —• J A/C ' EXISTING AT&T EQUIPMENT SHELTER VENT EXISTING UTILITY Y (RP.P eha� EXISTING ABANDONED CONCRETE PAD ��,.► I�hl �Fh1 I S� I�I�I�-li1J 12' WIDE GATE EXISTING SPRINT TELCO & / 1/ METER ON CONCRETE POST EXISTING GRAVELED - AREA EXISIRM STING SPRINTC86NENTRN&R rnurorrcr�err EXISTING HANDHOLE (TYP.) EXISTING TELCO PED. pTYP. OF 2) EXISTING SPRINT EQUIPMENT SHELTER EXISTING BUILDING jEXISTING GRAVELED - - -- - - - AREA SITE PLAN WAVEGUIDE (TYP. OF 4) VERIZON GEN. EXISTING VERIZON WIRELESS EQUIPMENT SHELTER EXISTING UTILITY H-FRAME EXISTING 6' HIGH CHAIN -LINK FENCE (TYP.) REV DATE DESCRIPTION A 1/29/19 PRELIMINARY CDs REV •A• 0 2/4/19 REV 0 CDs LSSUED USA MG PROJECT NO.: 12190001-11 DRAWN BY: CHECKED W.ML FN 8601 W SUNRISE BLVD PLANTATION, FL 33322 CcCROWN v CASTLE 6420 CONGRESS AVE SUITE 2000 BOCA RATON, FL 33487 PREPARED BY: ® ENGINEERING 2818 CYPRESS RIDGE BLVD. SUITE 110 WESLEY CHAPEL, R 33544 (813) 994-0365 R COA /31705 No 72513 •�T� FEBRUARY 04, 2019 MARC P. MAIER, PE FL PROFESSIONAL ENGINEER UC. 9 72513 WFTPIERCE FA #zooeogoi CC BU# 8138312 8701 ORANGE AVE FT PIERCE, FL 34945 SITE PLAN s EET NUMBER C-1 NOTES CONTRACTOR IS RESPONSIBLE FOR MODIFYING 1. A STRUCTURAL ANALYSIS SHALL BE THE RAYCAP INSTALLED ON THE TOWER TO PERFORMED BY THE OWNER'S AGENT TO ACCOMMODATE THE QUANTITY OF RRU'S. CERTIFY THAT THE EXISTING/PROPOSED COMMUNICATION STRUCTURE AND COMPONENTS ARE STRUCTURALLY THE CONTRACTOR MUST FIELD VERIFY ALL ADEQUATE TO SUPPORT ALL EXISTING MEASUREMENTS AND FIELD CONDITIONS PRIOR AND PROPOSED ANTENNAS, COAXIAL TO THE COMMENCEMENT OF CONSTRUCTION. CABLES AND OTHER APPURTENANCES. THE OWNER'S AGENT SHALL FURNISH A CERTIFICATION LETTER SEALED BY A REGISTERED PROFESSIONAL ENGINEER STATING THAT THIS STRUCTURAL ANALYSIS WAS PREPARED IN ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS. 2. IF ANY WORK IS PERFORMED AT THIS SITE THAT REQUIRES THE SITE TO BE OFF AIR OR TURNED DOWN, THE SWITCH IS TO BE NOTIFIED 48 HOURS PRIOR TO CONSTRUCTION VIA NCR/CTS. G7 3. INSTALLATION SHALL BE CONDUCTED BY FIELD CREWS EXPERIENCED IN THE ASSEMBLY AND ERECTION OF RADIO 7oP OF TOWEL ANTENNAS, TRANSMISSION LINES, AND EHSE ANTENNAWORK ELEV. 250'-O" AGL 3 `GNM713 REQUITO REMENTS ODF PER TSUPPORT SCOW MANUFACTURER'S SPECIFICATION. 4. ANTENNA AND MOUNT DESIGN MUST COMPLY WITH TIA-EIA-222-G AND ALL LOCAL CODES. 5. CONTRACTOR TO PROVIDE THE PROPER COAX JUMPER SUPPORT ATTACHMENTS TO THE TOWER AND ANTENNA MOUNT. 1. REFER TO RFDS FOR ADDITIONAL INFO. 2. ADJUST ANTENNA MOUNTS AS REQUIRED TO ACHIEVE THE AZIMUTH SPECIFIED AND LIMIT RF SHADOWING 3. UNLESS NOTED OTHERWISE THE CONTRACTOR MUST PROVIDE ALL MATERIAL NECESSARY. 4. CONTRACTOR TO RETURN ALL EXISTING ANTENNAS BEING REMOVED TO AT&T. EXISTING AT&T CABLES ROUTED UP THE TOWER PER STRUCTURAL ANALYSIS. EXISTING SELF SUPPORT TOWER EXISTING AT&T EQUIPMENT SHELTER OTHER CARRIERS OMITTED FROM TOWER TO PROVIDE CLARITY rE OF EXISTING & PROPOSED AT&T ANTENNAS /` E1.EV. = 146'-0" AGL TOWER ELEVATION 5-'1 SCALE: N.T.S. 0 A � Al EXISTING ANTENNA IN POSITIONS #1 TO REMAIN (ALPHA & GAMMA SECTOR, 2 TOTAL) EXISTING RRUS-32 ON BACK TO BACK RRU MOUNT IN POSITION #1 TO REMAIN (1 PER SECTOR, 3 TOTAL) EXISTING ANTENNA IN POSITIONS #3 & #4 TO REMAIN (ALPHA & GAMMA SECTOR, 4 TOTAL) 146'-0" EXISTING RAYCAP SURGE PROTECTION BOX AGL MODEL #DC6-48-60-18-8F & #DC6-48-60-18-8C TO REMAIN (3 TOTAL) EXISTING ANTENNA IN POSITIONS #1 & #4 TO REMAIN (BETA SECTOR, 2 TOTAL) '1!EC7OR EXISTING ANTENNA CONFIGURATION DETAIL n 5-1 SCALE: t"=8' T CONTRACTOR TO ENSURE MINIMUM OF 36" EDGE TO o EDGE SEPARATION BETWEEN THE 700 812. B17, B29 NOTES A AND 700 B74 ANTENNAS PER SECTOR AND THE �I �_ ANTENNA BACKPLANES OF SAME ON DIFFERENT FACE'S REFER TO RFDS FOR 9 �9 (ADJACENT SECTORS ON SAME RAD CENTER) ADDITIONAL INFO. REMAINDER OF ANTENNAS TO BE EQUALLY SPACED NOTE: a PROPOSED 850/B74-4478 TO BE INSTALLED AT GROUND LOCATION (1 PER SECTOR, 3 TOTAL) PROPOSED DIPLEXERS TO BE INSTALLED AT GROUND LOCATION (2 PER SECTOR, 6 TOTAL) G7 146'-0" AGL AL_ POSED,&B2 I B66_A=88 BAC O0��BACK RRU AUNT IN POSITION #4 OpM T G3 "`i(1�R60 PERZ SECTOR 3�OTAL') SEcxOF — 250 Sf�OR z qZ a (B TA T10. ) n PROPOSED ANTENNA CONFIGURATION DETAIL 5-1 SCALE: 1-=W REV DALE DESCRIPTION A 1/29/19 PRELIMINARY GO. REV A" 0 2/4/19 REV 0 ON ISSUED USA ENG PROJECT NO, 12190001-11 DRANK BY: CHECKED BY: ML M at&t 8601 W SUNRISE BLVD PLANTATION, FL 33322 CCCROWN CASTLE 6420 CONGRESS AVE SUITE 2000 BOCA RATON, FL 33487 PREPARED BY: ® ENGINEERING 2818 CYPRESS RIDGE BLVD. SUIT_ 110 WESLEY CHAPEL, FL 335" (813) 999-0365 FL COA #317D5 E IV str;' No 72513 *% 7e � n: LSiAPE OF ;#fj EBRUARY 04, 2019 MARC P. MAIER, PE L PROFESSIONAL ENGINEER UC. # 72513 ViFTPIERCE FA #iooso5os CC BU# 83138312 8701 ORANGE AVE FT PIERCE, FL 34945 TOWER ELEVATION AND ANTENNA ORIENTATION SHEEP NUMBER S-1 /REV I OATS I DESCRIPTION i 1. n 20.0- L KATHREIN - 80010965 K 5-2 BWLE: N.T.B. MISCELLANEOUS MATERIALS SCHEDULE DESCRIPTION MODEL NUMBER QUANTITY SNAP -IN HANGER TH496-DC114 - HANGER ADAPTER GROMMET CX608-HA0711 - HOISRNG GRIP CX051-HG38PL - HOISRNG GRIP CX06-HC12PL - GROUNDING KIT - - FIBER OR DC BUNDLE SNAP IN HANGER ROSENBERGER PART NO. TH496-DC114 OR EQUIVALENT HANGER ADAPTER GROMMET — ROSENBERGER PART NO. CX608-HA0120 OR EQUIVALENT NOTES 1. REFER TO JSA DOCUNDOS FOR EXACT CABLE NUMBER AND MANUFACTURER SPECIFICATIONS FOR PROPER GROMMEIS AND HANGER TO SUPPORT THE FIBER AND DC CAME BUNDLES. 2. REFER TO STRUCTURAL ANALYSIS FOR EXACT CABLE ROURNG AND MOUNTING CONFIGURATION. FIBER BUNDLE RANGER ADAPTER GROMMET — ROSDBDRGER PART NO. CX608-HA0711 DR EQUIVALENT SNAP IN HANGER ROSENBERGER PART NO. TH496-DC114 OR EQUIVALENT DOUBLE CLAMP SNAP IN HANGER ANTENNA TILT ROWDED W/ PIPE ROWDED W/ AT&T PIPE 'ROVIDED W/ ANTENNA MOUNTING DETAIL 5-3 BWLE: N.T.3. KEYNOTE LEGEND: 1. SECTOR GROUND BAR (IYP). 2. COLLECTOR GROUND BAR. 3. NEW ANIEMRA 4. SINGLE PAIR FIBER & DC POWER. 5. JUMPER CABLE, 1/2- (TIP). 6. PIPE MOUNT. 7. DC POWER & FIBER TO RAYCAP UNIT. 8. REMOTE RADIO HEAD (RRH) (IF APPUCABW. 9. DC6 RAYCAP SURGE SUPPRESSOR (IF APPLICABLE). #2 SAND COPPER TRORm IN NMLT (NON-MEFANC UQUID TIGHT) (TIP) #2 SOLID COPPER TINNED IN NNLT (NON-METAIIC LIQUID Tom) Y #2 SOLID ICOPPER TINNED N NULTNLT ((NOON) METAUC LIQUID TIGHT) (TYP1. UTL17E DUSIOIG AT&T GROUND BARS AND GROUNDING. 2. ADD GROUND BARS IF THERE ARE INSUFFICIENT LUG POSFIIONS. 3. REFERENCE AT&T BONDING & GROUNDING PRACTICE TP76416. IUSA ENO PROJECT NO.: 12190001-11 1 ML I FN J eatm 8601 W SUNRISE BLVD PLANTATION, FL 33322 CCCROWN v CASTLE 6420 CONGRESS AVE SUITE 2000 BOCA RATON, FL 33487 PREPARED BY: ®IENGINEERING 2818 CYPRESS RIDGE BLVD. sun 110 WESLEY CHAPEL, FL 33544 (813) 994 0365 FL ODA 031705 G E iv '4FAQ' NO 72513 3 A% STATE OF :4 Vj'uNAe as =EBRUARY 04, 2019 MARC P. MAIER, PE FL PROFESSIONAL ENGINEER LIC. # 72513 WFTPIERCE FA #ioo8osoz CC BU# 813812 8701 ORANGE AVE FT PIERCE, FL 34945 SHEET DESCRIPRON MISC. DETAILS HANGER ADAPTER GROMMET DETAILS 5-2 SCALE: N.T.S. 4 ANTENNA GROUNDING SCHEMATIC S2 SCALE: N.T.S. S-2 rn 0 N ERICSSON RRUS-B14 4478 -DIMENSIONS (H x W x D): 16.5" x 13.4" x 7.7" (INCLUDES SUNSHIELD) -WEIGHT: 59.9 LES -CLIMATE: -40'C TO +55'C (SELF CONVECTION SILENT, NO FANS, IP55) -POWER CONSUMPTION: 80 WATTS (TYP.) N9 RRUS CAN ONLY BE PAINTED ON SOLAR SHIELD. n =t14 4478 DETAIL SJ SCALE: N.TS. ERICSSON RRUS-8843 B2/B66A -DIMENSIONS (H x W x D): 14.96" x 13.19" x 11.1" (INCLUDES SUNSHIELD) -WEIGHT: 75 LBS -CUMATE: IP65, -40'C TO +55'C -48 VDC 3 WIRE (2 DC POWER PORTS OF 20A) -32OW OF TOTAL POWER WITH 3 CONFIGURATIONS RRTE US CAN 9i PAINTED ON S n RRUS 8843 B2/666A DETAIL S3 SGALE: N.T.S. ERICSSDN 4449 35/812 -DIMENSIONS (H x W x D): 14.96" x 13.19" x 10.43" (INCLUDES SUNSHIELD) -WEIGHT: 73 LES -CLIMATE: -40'C TO +55'C (SELF CONVECTION SILENT, FANS OPT., IP65) -POWER CONSUMPTION: 80 WATTS (TYP.) NOTE: RRUS CAN.. - PAINTED ON SOLAR SHIELD. � 1 RRUS 4449 65/B12 DETAIL SJ BCALE: N.T.S. oaauom.auL Q 000 000 W EARTH n myS D13C0061 F1 V51-1 SJ SCALE; N.T.S. LOW RRU RRU ANTENNA MAST PIPE ERICSSON RRU SUPPORT KR PART #SXK 1250461/1 (OR APPROVED EQUAL) FOR RRU'S REQUIRING A2 SUPPORT USE PART #SXK 1091946/1 & /2 (OR APPROVED EQUAL) NOTE: DETAIL IS DIAGRAMMATIC. CONTRACTOR TO INSTALL RRU'S ON RRU MOUNT BEST SUITED FOR ANTENNA CONFIGURATION. BACK VIEW ANTENNA ANTENNA MAST PIPE ERICSSON RRU SUPP09T KIT PART #SXK 1250461/1 (OR APPROVED EQUAL) FOR RRU'S REQUIRING A2 SUPPORT USE PART #SXK 1091946/1 & /2 (OR APPROVED EQUAL) NOTE: DETAIL IS DIAGRAMMATIC. CONTRACTOR TO INSTALL RRU'S ON RRU MOUNT BEST SUITED FOR ANTENNA CONFIGURATION. SECTION A n RRU OUNTING DETAIL 53 SCALE: N.TS.M (REV I DATE I DESCRIPPON \ IUSA ENG PROJECT NO.:12190001-11 GRIM W. I CHECKED BY: l ML � N *S at&t 8601 W SUNRISE BLVD PLANTATION, FL 33322 CCCROWN v CASTLE 6420 CONGRESS AVE SUITE 2000 BOCA RATON, FL 33487 PREPARED BY: ®IENGINEERING 2818 CYPRESS RIDGE BLVD. SUITE 110 WESLEY CHAPEL, FL 33544 (813) 994-0385 FL COA #31705 iiO C P ``�ii�Pa• C E �� � �,\ NSF••; Q NO 72513 ®SOSTAT OF •fit S • "�C. pp��� (0r•`•` \�, Saes �TYA�-r `;O ie! IFEBRUARY 04, 2019 MARC P. MAIER, PE FL PROFESSIONAL ENGINEER UC. # 72513 WFTPIERCE FA #iooso5os CC BU# 8i3812 8701 ORANGE AVE FT PIERCE, FL 34945 SHEET DESCRIPRON MISC. DETAILS SHEET NUMBER S-3 DC / FIBER DEMARCATION BOX MTCAP DC FlffRDEMARCATION BO% CABI6 NOTES MOUNTWG HIRGHT MODEL OTT MDRS� Ol'Y 1131GM PER 1ME lw9 1)064BFh18 1 InOSENBERGER ]8 PAIR FlBERIRW% 3/8` 3 2W-0' 1494 DC64B-�]B-8[1 2 -JBAWGTINNEDCOPPMOONDUCTORS 3/4' 1 6 1 ffi-O' ANTENNA AND COAX SCHEDULE ANTENNAS GBIB MU A2 UIPIE1031/FlLTER TAR SECTOR A2 RAD ANTENNA q1Y APPROXIMATE ANIENNAVIKS DOWN Nti MOOR SIZE OTY IENG LINE COLOR CODE MOOR MOD MOOR i1NR GW4D ( MODELIIQMI CFNIELi MAID MOOR EIEC MECH IQIY "MIX) SSW 146'd ANOREW SSNI01-ID6H 1 H+]L7aW=11.9'zD=].1• _ _ 1-S/8- 2 2W-W 1REO ROSENURMILFIRERNP JUER(DUTORRU) 3/8` 1 394 IRED I RRU.S-32 I - - - - - - ROSMMRGERSINGIEPAIflOCCARE(DC6TORRU) 7/16• 1 IV-W IRED 1/TCOAXJUIMER RRUTOANTMNA I/2• 6 lW4' IRM ALPHA AWM(M) 3W 146-P ANDREIN S13NH1410850 1 H=M9'a W=3L9'x D=7.V ROSMMGERFIREAJUMPER(DC6TORRU) 3/8° ROSMMRGER5INGIEPAIRDCaBE(DC6TORRUI 7/IC WCOAXJUJWER(RRUTOANIENNA) 112` 6 10'-(1° 3RED ALPHA (M) 397 1494' ANDREW SBNH1F10856 1 Ik]i7zW�9'zD=].1- - 1-5/8° R05B�IBE3iER FIBELNUMPFR (IXSrOARU) 3AT : 394' 4RE0 •814441a 1 - 08(DOfi]i1V51-1 - 2 _ _ ROSENBERGMSINGIEPAIRDCfABiE(D0670GN) 711V 2 1S4' IRFD 87/W6A-®l3 I COA%JUMPER(MTOANIFNNA) I/Y - - - - BETA(011 UT 1w-P KMW ET-x-UM6&14616-IRAT I H=7Yx W=1TxD3r - _ I 5/a' 3 ffi4Y iBLUE ROSENRRMRFIURJUIWM(DC6TORRU) 3/9' 1 W9 - 18LUE R usm- ROSENRRGERSINGEPAIRDCCARE(DOGTORRU) 7/16- 1 15--0" IBLUE I/YCOAXJUMPER(RRUTOAMENNA) 1/2, 6 W-o" IBLUE 6ETA M BETA(®1 110 116-T mmIlIaN 8m109f9( 1 WMr.W=2Dr.09` NOBENBERGERNBFIYNfW B11DC6 TO RRUI Sle 2 19-T 3RUE 851812IM9 1 ImiRIBER(iER61NG1EPAIROCGBIElOC6TO WN) 71W 2 194' 38LUE - _ 1/T'ODAxIUMPER(RRUTOANTENIw w 8 104• 31AUE BETA(B41 110' W4 KMW U-X-UM-%14$]AIR-AT 1 H-7P•W=1YxD r _ _ wF]-SO RO MMRMRFIRMJUW0(DC6TORRu) 3/8' 2 194' 4BLM •B14M18 1 - DBCOD61FIV -1 - 2 - - ROSENBERGERSINGIEPAIR DCC (DOSTO RRUI 7/36- 2 194' 4BLUE BI/B661E 1/2•COAXJUWER RRUTOANTTNNA) 1/J.' 4 ID4• 4DUA I GAMMA(GII 225- 149-0' ANDR , SBNN IiDBSB 1 Ip lrxlffP .TxD=].1- _ _ _ 1-5/8" 2 2070 IGREEN ROSENBERGERFIBMIJI M(DCSTORRU) 318• 1 194 1CdEQl RRVS32 ROSEN ]/SB I I9-0• IGIIEVY - 1/2'COA%IIRYWER RflUTOANIFNNA I/2" 6 1D-0" IGIEEN - - GAMMA Gzl GAM4N(G3) 22S 149-P ANDflEW 5&JHH-IDHID 1 N=R7'x W=3LD'a D=].1' _ ROSENBERGERFIMJUMPER(DXT0NU) 3/8• 2 194 3GIEEN BS/B12 I - - - - - - ROSMKRMRSINGIEPAIROCCARE(DOGMMN 7/10' 2 19-V 3GREEN _ IMOOAXJUIWER(RRUTOANIQ4NA 6 10-W 3MEEN - GANAAA(G4) ZL4 316'_W ANDREW SBNHK10R58 1 WnTxW=]I.r.a 7.1' _ UDF]_SO 7/8• 2 EI010 4GIEEN _ ROSMBERURFIBERJUATER(DOSTORRU) Sm 2 194' 4GiEEN M4.4478 1 - DBWO61F1V3-1 - 2 - - ROSMURGERSINGEPAIRXCAG.E(DC6TOMq 7/16" 2 194' 4MEEN IIZ( 880 I - - - - - 1/TCOA%JUWER(RRUTOANRNNA) 1/T 4 104' 40M TOTAL 9 •ANIENNAANDCOAXINMO PONPRMIDEOFRWM LTEKUMVLMDATED12/2g118. ALI-5/CCOAIIIACTW 12 zW-W TOTAL ]2 0 TOTAL 0 6 TOTAL 0 ALl-5/!T [OA%(RIACNVE) •CONIRACIORTOVERINUINMWITHNENTPMORTOCONSIRUCRON. • COAX IENGUIS AREAPPROXIMATE AND IMSTU VERIFIED PRIORTOCONSIIIUUION. • AM ODAK SHAR BE COLOR COOED ATTOPAN BOTTOM JUWERANDATTOP OF TOWER 11070MOFTOWER,ANDINSIDESHRTERON MAIN COAX -PROPOS®BIH Ift T Ili)ATGWUNDLEVEL(MMOMINT AL) ALFUIELtIUN®ER 7s 229-0` ALDCIUMPER 15 IS4 SO . 6pp-0" ALS/i6'RETCABlES 3 6m4' ATTHEPORTANDATTHEAUMNNA. (Q.:) ANTENNA 84 COAX SCHEDULE - SCALE: N.T.S. REV DATE DESCRIPTION A 1/29/19 PRELIMINARY CDs REV °A" 0 2/4/19 REV 0 CDs ISSUED USA MG PROTECT NO.: 12190001-11 DRAWN BY: CHECKED RY: NL ilR at&t 8601 W SUNRISE BLVD PLANTATION, FL 33322 CROWN v CASTLE 6420 CONGRESS AVE SUITE 2000 BOCA RATON. FL 33487 PREPARED BY: ®IENGINEERING 2818 CYPRESS RIDGE BLVD. SURE 110 WESLEY CHAPEL, FL 33544 (813) 994-0365 FL COA /31705 •- tT No 72513 ST v � e Vll A =EBRUARY 04, 2019 MARL P. MAIER, PE FL PROFESSIONAL ENGINEER LIC. # 72513 WFTPIERCE FA #ioososoz CC BU# 813812 8701 ORANGE AVE Ff PIERCE, FL 34945 ANTENNA SCHEDULE WM NUMBER AN-1 File: T:\00-2019 PROJECTS\01-Crown\Crown - AT&T LTE\WOYIECE-10080502-81381 Sieefh92W invalid reference File: T:\00-2019 PROJECTS\01-Crown\Crown - AT&T LTE\WTFPIECE- H®tg2& imelid reference ONE -LINE DIAGRAMS E-1 SCALE: N.T.S. ELECTRICAL SCOPE OF WORK: INSTALLATION OF (3) NEW 814 4478 RADIOS INSIDE THE EQUIPMENT SHELTER ON THE GROUND. THESE RADIOS WILL REQUIRE A NEW DC POWER CABLE PLUGGED FROM THE RADIOS TO THE EXISTING RAYCAP SURGE PROTECTOR INSIDE THE SHELTER. NO NEW A/C ELECTRICAL UPGRADES ARE PROPOSED. ERICSSON RRU BREAKER REQUIREMENTS ERICSMN 9AOI0 8¢REAHER TECHNOLOGY RRUS 32 866 M AMP AWS (2100) RRUS 32 830 20 AMP WCS (2300) RRUS 32 82 30 AMP PCS (1900) RRUS 11 25 AMP VMMS RWDS (7M [5121. M [01 19M (MI. 21M [84D MUS12 + A2 25 AMP VMMS BNNS (850 [651 ISM [821. 21M [e4D RRU 4415 825 25 AMP ISM RRU 026 B66 30 MP 21M RRU 4478 B14 25 AMP 700 RRU 4478 B5 25 AMP 850 RRUS E2 B29 25 AMP 700 RRUS 4449 85/B12 2.25 AMP 7M/SM RRUS WU 82/B66 2xM MP ISM/2100 1 •••pdf 10 AMP 850 MUS 2205 846 10 AMP 5 GH 4 2 5 3 6 ---- — — — — — AWS RRH 7 I DIGLTE I - — — ITAL — UNIT B74 RRH KEYNOTE LEGEND: 1. -48V DC POWER PLANT. CONTRACTOR TO VERIFY CORRECT BREAKER SIZE IS INSTALLED FOR EACH RRU PER CHART. 2. (1) RACK MOUNTED RAYCAP DC SURGE PROTECTOR (DC6-48-6G-RM). 3. RAYCAP FIBER AND DC DISTRIBUTION UNIT (DC6-48-60-18-8F) TOWER MOUNTED. 4. /8 AWG SHIELDED CONDUCTORS (WR-VG82ST-BRDA). WIRRgWE (2) 6-CONDUCTOR #8 AWG BUNDLES FOR DC POWER FROM RACK MOUNTED RAYCAP SURGE PROTECTION UNIT TO THE RAYCAP FIBER AND DISTRIBUTION UNIT ON TOWER. 6. DC CABLE ROUTED TO RRH UNITS. 7. 012 AWG SHIELDED CONDUCTORS (WR-VG122ST-BRDA). n TYPICAL DC RISER DIAGRAM E-1 SCALE: N.T.S. REV DATE DESCRIP ON A 1/29/19 PRELIMINARY COB REV 'A' 0 2/4/19 REV 0 CO. ISSUED USA MG PROJECT NO.: 12190001-11 DRAWN BY: CHECKm BY: ML FN at&t 8601 W SUNRISE BLVD PLANTATION, FL 33322 CCCROWN CASTLE 6420 CONGRESS AVE SUITE 2000 BOCA RATON, FL 33487 PREPARED BY: ®IENGINEERING 2818 CYPRESS RIDGE BLVD. SUITE 110 WESLEY CHAPEL, FL 33544 (813) 994-O.T65 FL COA 831705 No 72513 RUARY 04, 2019 MARC P. MAIER, PE FESSIONAL ENGINEER LIC. It 72513 WFTPIERCE FA #10080502 CC BU# Si38I2 8701 ORANGE AVE Ff PIERCE, FL 34945 ANTENNA ONE-UNE DIAGRAM SHEET NUMBER E-1