HomeMy WebLinkAboutSTRUCTURAL ANALYSIS REPORTa
Date: January 23, 2019
Andera Slaughter
Crown Castle
8000 Avalon Blvd Suite 700
Alpharetta, GA 30009
Subject.
Carrier Designation:
Crown Castle Designation:
Engineering Firm Designation:
Site Data:
Dear Andera Slaughter,
SCANNED
St. Lucie County
Structural Analysis Report
AT&T Mobility Co -Locate
Carrier Site Number:
Carrier Site Name:
Crown Castle BU Number:
Crown Castle Site Name:
Crown Castle ME Job Number:
Crown Castle Work Order Number:
Crown Castle Order Number:
B+T Group Project Number:
JFB+T GRP
B+T Group
1717 S. Boulder, Suite300
Tulsa, OK 74119
(918) 587-4630
10080502
WFTPIERCE (FP30)
813812
FI West Fort Pierce
553175
1684679
475131 Rev. 0
77034.008.01
8701 Orange Avenue, Ft Pierce, St. Lucie County, FL
Latitude 27026' 44.54", Longitude -80024' 46.59"
250 Foot - Self Support Tower
B+T Group is pleased to submit this "Structural Analysis Report" to determine the structural integrity_ of the
above -mentioned tower.
The purpose of the analysis is to determine acceptability of the tower stress level. Pased on our analysis we
have determined the tower stress level for the structure and foundation, underthe following load case, to be:
LC5: Proposed Equipment Configuration
Sufficient Capacity
This analysis utilizes an ultimate 3-second gust wind speed of 157 mph as required by the 2017 Florida Building
Code, 6th Edition, Applicable Standard references and design criteria are listed in Section 2 - Analysis Criteria.
Structural analysis prepared by: Jacob Johnson, E.I.T.
Respectfully submitted by: B+T Engineering, Inc.
COA: 27496; Expires: 2/28/2019
NK
�...... E.
.W .
a -
E
STATE OP
N
0/0 AL t'0\
John W. Kelly, P.E.
tnxTower Report - version 8.0.5.0
250 Ft Self Support Tower Structural Analysis
Project Number77034.008.01, Order475131, Revision 0
TABLE OF CONTENTS
1) INTRODUCTION
2) ANALYSIS CRITERIA
Table 1 - Proposed Equipment Configuration
Table 2 - Other Considered Equipment
3) ANALYSIS PROCEDURE
Table 3 - Documents Provided
3.1) Analysis Method
3.2) Assumptions
4) ANALYSIS RESULTS
Table 4 - Section Capacity (Summary)
Table 5 — Tower Component Stresses vs. Capacity - LC5
4.1) Recommendations
5) APPENDIX A
tnxTower Output
6) APPENDIX B
Base Level Drawing
7) APPENDIX C
Additional Calculations
January 23, 2019
CCI BU No 813812
Page 2
tnxTower Report - version 8.0.5.0
250 Ft Self Support Tower Structural Analysis
Project Number77034.008.01, Order475131, Revision
1) INTRODUCTION
January 23, 2019
CCI BU No 813612 +
Page 3
This tower is a 250 ft. Self -Support tower designed by FWT Inc. in June of 1998. The tower was originally
designed for a wind speed of 110 mph per TIA/EIA-222-F. The tower has been modified per reinforcement
Drawings prepared by B&T Engineering, in May of 2008.
2) ANALYSIS CRITERIA
TIA-222 Revision:
TIA-222-H
Risk Category:
II
Wind Speed:
157 mph
Exposure Category:
C
Topographic Factor:
1
Service Wind Speed:
60 mph
Table 1 - Proposed Equipment Configuration
Mounting
Level (ft)
Center
Line
Elevation
Number .
of
Antennas
Antenna
Manufacturer
Antenna Model
:
Number
of Feed
Lines
Feed
Line Size
(in)
143.0
146.0
6
Commscope
I SBNHH-1D85B
12
6
3
1
1-5/8
3/4
3/8
5/16
3
Ericsson
RRUS 32
3
Ericsson
RRUS 4449 135/612
3
Ericsson
RRUS 8843 132/1366A
1
Kathrein
80010965K
2
Kmw Comm.
ET-X-UW-68-14-65-18-IR-AT
2
Raycap
DC6-48-60-18-8C
1
Raycap
DC6-48-60-18-8F
143.0
3
Connect -It
PVFM12-3-3-96-3 Mount
Table 2 - Other Considered Eauipment
Center
Number
Feed
Mounting
Line
Number of
Antenna
Antenna Model
of Feed
Size
L_ Lin(in)
Level (ft)
Elevation
Antennas
Manufacturer
Lines
(in)'
(ft)_
-
6
Commscope
E15R05P19
3
Ericsson
RRUS12/RRUS A2
244.0
12
1-5/8
6
Jma Wireless
X7CQAP-665-VRO
243.0
1
1-1/4
1
Raycap
RXXDC-3315-PF-48
6
Css
DBC-7CAP
243.0
1
--
Sector Mount [SM 402-31
3
Ericsson
800MHZ SMR FILTER
133.0
3
Ericsson
RRUS-11800MHZ
3
Commscope
TTTT65AP-1XR
132.0
3
1-1/32
3
Rfs Celwave
APXVS PP18-C
130.0
131.0
3
nokia
FZHJ-RRH
1
7/8
3
ericsson
RRUS 31 B25
130.0
9
rfs celwave
ACU-A20-N
1
Sector Mount [SM 702-31
tnxTower Report - version 8.0.5.0
250 Ft Self Support Tower Structural Analysis
Project Number77034.008.01, Order475131, Revision 0
3) ANALYSIS PROCEDURE
Table 3 - Documents Provided
January 23, 2019
CCI BU No 813812
Page 4
Document
Remarks
Reference
Source
Online Order Information
AT&T Mobility Co -Locate, Revision # 0
475131
CCI Sites
Tower Manufacturer Drawing
FWT, Design No. S98-0541-A
906968
CCI Sites
Tower Modification Drawing
B&T Engineering, Project No.77034
2271344
CCI Sites
Post Modification Inspection
VSI, Project Number 080878.01
2323138
CCI Sites
Foundation Drawings
Information Not Available
Geotech Report
PSI, Inc. Project No.397-85068-2
115206
CCI Sites
Antenna Configuration
Crown CAD Package
Date: 01/18/2019 1
CCI Sites
3.1) Analysis Method
tnxTower (version 8.0.5.0), a commercially available analysis software package, was used to create a
three-dimensional model of the tower and calculate member stresses for various loading cases.
Selected output from the analysis is included in Appendix A.
3.2) Assumptions
1) The tower and structures were built and have been maintained in accordance with the
manufacturer's specification.
2) The configuration of antennas, transmission cables, mounts and other appurtenances are as
specified in Tables 1 and 2 and the referenced drawings.
3) Mount areas and weights are assumed based on photographs provided.
4) The existing base plate grout was not considered in this analysis.
This analysis may be affected if any assumptions are not valid or have been made in error. B+T
Group should be notified to determine the effect on the structural integrity of the tower.
4) ANALYSIS RESULTS
Table 4 - Section Capacity (Summary)
Section
No.
Elevation
(ft)
Component Type
Size
Critical
Element
P (K)
SF*P_allow (K)
%
Capacity
Pass
/ Fail
T1
250 - 240
I Leg
I 2
I 1
I -3.633
I 51.751
7.0
I Pass
T2
240 - 220
1 Leg
1 2 1/2
19
-30.407
70.833
42.9
Pass
T3
220 - 200
Leg
3
40
-62.513
144.956
43.1
Pass
T4
200 -180
1 Leg
3 1/4
61
-97.541 -
192.479
50.7
Pass
T5
180 - 160
1 Leg
3 1/4
82
-132.221
1 262.734
50.3
Pass
T6
160 - 140
1 Leg
1 3 1/2
121
-173.775
1 321.973
1 54.0
1 Pass
T7
140 -120
1 Leg
1 3 3/4
160
1 -227.087
1 386.416
58.8
Pass
TB
120 -100
1 Leg
4
1 199
-287.506
1 455.948
63.1
Pass
T9
100-80
Leg
41/4
238
-350249
530.481
66.0
Pass
T10
80-60
Leg
41/2
277
-397.527
609.947
65.2
Pass
T11
60 - 40
Leg
4 3/4
328
-461.048
694.293
66.4
Pass
T12
40 - 20
Leg
4 314
379
-524.438
1 694.293
1 75.5
1 Pass
T13
20 - 0
Leg
5
430
-587.351
783.476
75.0
Pass
T1
250-240
Diagonal
L2x2x3/16
7
-2.270
16.441
13.8
15.1 (b)
Pass
T2
240-220
1 Diagonal
L2 1/2x2 1/2x3/16
22
-4.620
18.705
24.7
Pass
tnxTower Report - version 8.0.5.0
250 Ft Self Support Tower Structural Analysis
Project Number 77034.008.01, Order 475131, Revision 0
January 23, 2019
CCI BU No 813812
Page 5
Section
No.
Elevation
(ft)
-
Component Type
-
Size
-
Critical
Element
P(K)
-
SF`P_allow (K)
- -
%
Capacity
Pass
/Fail
I
26.6 (b)
T3
220-200
Diagonal
L21/2x21/2x3/16
43
-5.850
15.126
38.7
Pass
T4
200-180
- Diagonal
L3x3x3/16
64
-7.380
19.745
3.7'4
40.9 (b)
Pass
T5
180-160
Diagonal
2121/2x21/2x3/l6x3/8
86
-9.781
32.930
29.7
Pass
T6
160-140
Diagonal
21-21/2x21/2x3/16x3/8
125
-12.554
27.196
46.2
Pass
T7
140-120
Diagonal
2121/2x21/2x3/16x3/8
164
-17.189
22.693
75.7
Pass
TB
120 - 100
Diagonal
2L&W/18x3/8
203
-18.950
32.178
58.9
Pass
T9
100 - 80
Diagonal
2L3x3x5/16x3/8
242
-21.330
45.167
47.2
Pass
T10
80-60
Diagonal
2L3x3x3/16x3/8
281
-27.609
52.400
62.7
76.4 (b)
Pass
T11
60 -40
Diagonal
2L3x3x3/16x3/8
332
-28.755
49.847
57.7
79.8 (b)
Pass
T12
40-20
Diagonal
2L3x3x1/4x3/8
383
-29.733
63.962
46.5
62.3 (b)
Pass
T13
20 - 0
Diagonal
2L3x3xl/4x3/8
434
-30.387
59.676
50.9
63.9 (b)
Pass
T5
-180-160
Horizontal
L2x2x3/16
85
-2.649
5.536
47.9
Pass
T6
160-140
1 Horizontal
L2 1/2x2 1/2x3/16
124
-3.304
8.292
39.9
Pass
T7
140 - 120
Horizontal
L3x3x3/l6
169
-4.118
11.323
36.4
Pass
TB
1120 - 100
1 Horizontal
L3x3x3/16
202
-4.991
9.073
55.0
Pass
T9
100 - 80
Horizontal
L3x3xl/4
241
-6.074
9.68.7
62.7
Pass
T10
80-60
Horizontal
21-2 l/2x2.1/2x3/l6x3/8
280
-6.894
16.668
41.4
Pass
Tll
60-40
Horizontal
2L21/2x21/2x3ll6x3/8
331
-7.996
14.124
56.6
Pass
T12
40-20
Horizontal
21-21/2x21/2x3/16x3/8
382
-9.095
12.100
75.2
Pass
T13
20-0
Horizontal
2L3x3x3/16x3/8
433
-10.186
17.817
57.2
Pass
T1
250 -240
1 Top Girt
L2x2x3/16
6
-0.206
7.543
2.7
Pass
T10
80 - 60
Redund Horz 1 Bracing
2L2x2x3/l6x3/8
282
-6.896
33.446
20.6
Pass
T11
60-40
Redund Horz l Bracing
2L2x2x3/16x3/8
333
-7.997
29.757
26.9
Pass
T12
40-20
Redund Horz l Bracing
2LWx3/16x3/8
402
-9.097
25.730
35.4
Pass
T13
20-0
Redund Horz l Bracing
2L2x2x3/l6x3/8
435
-10.187
22.329
45.6
Pass
T10
80-60
Redund Diag l Bracing
2L2x2x3/16x3/8
309
-4.684
19.419
24.1
Pass
Ttt
60-40
Redund Diag l Bracing
2L2x2x3/l6x3/8
360
-5.247
17.599
29.8
Pass
T12
40 - 20
Redund Diag 1 Bracing
2L2x2x3/16x3/8
1 411
-5.798
F 15.933
36.4
Pass
T13
20-0
Redund Diag l Bracing
2L2x2x3/16x3/8
462
-6.333
14.506
43.7
Pass
T10
80-60
Redund Hip l Bracing
L2 1/2x2 1/2x3/16
327
-0.039
13.951
0.3
Pass
Tll
60-40
Redund Hip 1 Bracing
L21/2x21/24/16
378
-0.034
11.808
0.3
Pass
T12
40-20
Redund Hip l Bracing
L2 1/2x2 1/2x3/16
429
-0.038
10.124
0.4
(Pass
T13
20-0
Redund Hip l Bracing
L2 1/2x2 1/2x3/16
480
-0.033
6.775
0.4
Pass
T5
180 - 160
1 Inner Bracing
L2x2x3/16
96
-0.003
5.084
0.1
Pass
T6
160 -140
1 Inner Bracing
L2x2x3/16
133
-0.005
3.857
0.2
Pass
n
140 - 120
1 Inner Bracing
L2 1/2x2 1/2x3/16
174
-0.004
6.025
0.2
Pass
TB
120 - 100
1 Inner Bracing
L2 1/2x2 1/2x3/16
213
-0.005
4.852
0.2
Pass
T9
100 - 80
Inner Bracing
L3x3x3/16
252
-0.006
6.992
0.2
Pass
T10
80- 60
Inner Bracing
2L2x2x3/l6x3/8
306
-0.030
8.447
0.4
Pass
Tll
60-40
Inner Bracing
2L2x2x3/16x3/8
357
-0.026
7.155
0.4
Pass
tnxTower Report - version 8.0.5.0
250 Pt Self Support Tower Structural Analysis
Project Number 77034.008.01, Order 475131, Revision 0
January 23, 2019
CC/ BU No 813812
Page 6
Section
No.
Elevation
M
Component Type
Size
critical
Element
P (K)
SF'P=allow (K)
%
Capacity
Pass
/Fail
T12
140 - 20
I Inner Bracing
121_2 1/2x2 1/2x3/16x3/8
1408
-0.032
I 11.751
0.3
I Pass
T13
20-0
Inner Bracing
21-21/2x21/2x3/16x3/8
458
-0.027
10.199
0.3
Pass
Summary
Leg (T12)
75.5
Pass
Diagonal (Ttt)
79.8
Pass
Horizontal (T12)
75.2
Pass
Top Girt (T1)
2.7
Pass
Redund Horz 1
Bracing (T13)
45.6
Pass
_
Redund Diag 1
Bracing (T13)
q3.7
Pass
Redund Hip 1
Bracing (T12)
0.4
Pass
Inner Bracing (T11)
0.4
Pass
Bolt Checks
79.8
Pass
Rating =
79.8
Pass
Table 6 - Tower Component Stresses vs. Capacitv — LC5
Notes
Component
Elevation (ft)
% Capacity
Pass / Fail
1
I Redundant Connections
0-80
I 64.7
Pass
1
Anchor Rods
Base
95.5
Pass
1,3
Base Foundation
Base
69.4
Pass
Structure Rating (max from all components) = 95.5%
Notes:
1) See additional documentation in 'Appendix C —Additional Calculations" for calculations supporting the % capacity
consumed.
2) Rating per TIA-222-H Section 15.5.
3) Foundation capacity determined by comparing analysis reactions to original design reactions.
4.1) Recommendations
The tower and its foundations have sufficient capacity to carry the proposed load configuration. No
modifications are required at this time.
tnxTower Report - version 8.0.5.0
ry
m
C c+
rc
N
Sf
<
�
i
z
:N
�
$i
rc
C
J 4
a a
z
z i
�
�
C
ei
N
�
C
�
N �
rg
� n
�
6�
�0"mmo1aaa
.m. o
S
s
gam
250.0 ftft
240.0 ftft
Moo ftft
2000 ftft
Mon
1600ftft
I��li I I ��ru� iuiin
III uu� III
Moftft
60D ft
SYMBOL LIST
MARK SIZE MARK I SIZE
A L2,PxL16
MATERIAL STRENGTH
TOWER DESIGN NOTES
1. Tower designed for Exposure C to the TIA-222-H Standard.
2. Tower designed for a 157 mph basic wind in accordance with the TIA-222-H Standard.
3. Deflections are based upon a 60 mph wind.
4. Tower Risk Category II.
5. Topographic Category 1 with Crest Height of 0'
6. TIA-222-H Annex S
7. TOWER RATING: 79.8%
60oft
ALL REACTIONS
ARE FACTORED
MAX. CORNER REACTIONSATBASE:
4a.o ft
DOWN: 617 K
SHEAR: 74 K
UPLIFT: -518 K
SHEAR: 64 K
20A ft
AXIAL
99 K
SHEAR MOMENT
'
125 K15176 kip-R
0.0 fl
TORQUE 130 kip-ft
REACTIONS -157 mph WIND
B+T Group
1717 S. Boulder, Suite
3.T GRP Tulsa, OK 74119
Phone: (918) 587-4630
77034.008.01- FL WEST FORT PIERCE
FL (BU# 81381
Plot Plan
Total Area - 0.09 Acres
3.T GRP
B+TGroup
1717 S. Boulder, Suite 300
Tulsa, OK 74119
Phone: (918) 587-4630
°°77034.00t
P�i�.":
CIieM: Cn,. Ca
fie' T(A-222-H
81381
a
Lu
Leg Capacity
I 1 I I
I I I I
1 I I
I
1 I I I
I I I I
I I I 1
I I I I
I I I
I I I I
I I I I
I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I
I
I 1
I I I
I I I I
1 I I
I I I
I I I
I I I
I I I I
I I 1
I I I I
I I I
i 1 I I
I I 1 I
I
I I
I I I 1
I I 1 I
I I I I
I I I
I I 1 I
I I I I
I 1 I
I I I
I I I
1 I
I 1 I
I I
I
1 I
1 i I
-
:.I I
I I
I I
I i 1
I 1 1
I I 1 1
I I I I
I I 1 I
I I I I
I I I I
I I I
I I I
I I
I I I I
1 I I I
I I I I
I I I I
I I I
I I I
I
� I I
I I
I i I t
r1 I I
I I I r
TIA-222-H -157 mph Exposure C
Leg Compression (K)
Soo cMrIMUM-0Marim,
I I I I
I I I
I I I I
I I I I
I I I 1
1 I I 1
1 I I I
I I I
I I I I
I
I I I I
I I I
I I I I
I I I
I I I
I I I I
I I I
I I I
I I
I I
I I
1 I I
I I I
I I I
I 1 1 I
I I I
I I I
I I
1 I I
I
I I I
I I I
1 I I 1
I I I i
I I I 1
I I I
1 I I I I
I I I I
I
F J
I I I I
I I I
I I I
1 1 I
I 1
1 1 I I
I 1 1 I
I I 1 I
I r 1 I
I r r I
I 1 1 I
1 1 I I
1 I I I
r I I I
1 I I I
I I I I
I I I 1
I I I I
r I 1 1
I 1 I I
I I I I
I I I
I I I I
I I I 1
I I I I
I 1 I I
I 1 1
I I 1 I
I I I I
1 1 1 I
1 I 1 I
I ( I
1 I I 1
r I I I
I i I
I I
I i I I
I I I
MIW..->
"TX vroup
1717 S. Boulder, Suite 300
e-T GRP Tulsa, OK 74119
Phone: (918) 587-4630
I I
I I I I
I I 1 1
1 I
I I I 1
I I I I
I 1 I I
I I I
___I
1 I I
I I I I
I I 1 I
I I 1 I
I I 1 I
I I 1 I
I I I I
I I 1 I
I I
I I I
I I I
I I I
I I I
1 I I I
I I I I
I I I I
1 I I
I I I I
I I I 1
1 1 I I
I I I 1
1 I 1 I
1 1 1 1
1 1 I I
I I 1 1
I I I
I I I I
I I I I
I I I I
I I I I
I I I
I I I I
I
1 I
I I I
1 I
1 1
1. 1 I I
1
I 1 i 1
1 1 I 1
I I
I 1 I 1
I 1 1
1 I I 1
1 1 1
1 1 I
1 I I
1 I 1 1
I 1 1 1
I 1 I 1
_J----------
I"""" Crown Castle P"a"" I °'` Kiran I" P.:
FL
(BU# 81381
L
TIA-222-H -157 mph Exposure C Maximum Values
Vx Vz Mx Mz
Global Mast Shear (K) Global Mast Moment (kip-ft)
0
250
50
100
151
2
I 1 I
I I
I
I I I I
I I I
I
I I I I
I I I I
1
I I I I
I I I
I I I I
1 1 I I
I I
1 I
I I I
I I I
I I I
I I I
1 I
I I 1 1
I I I I
11
I I I
220
I
I I I
I I
1 I I I
I-
I I
I I I
I 1 I
I 11
11 1 1
I 1 I
1
I I I
1 I
I I I
i
20
I I
1 I I
1
_J_ L_J _L
I I I I
I I
I I I I
1
I I I
11
I I I I
I I
I I
I I
11
1 I I
I I I
1 I
I I I I
1
I I I
I
18
I I I
I
1
I I I
I I
I 1
4 -F 4 _r
-F-+ -I -4
-+ -I
I I I
I I I I
I I I I
I I I I
11 I 1
I I I
I I I I
I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I 11
I I I I
I I
1fi0
I I
I I I
1 1
I
1 1
-1 -
I' -I - 1
-T -I T 'I--
I I I I
I I I
I I I I
I I I
I I I
I I
I I I
I
I I I
14
I I I
I I I I
_ _L_J_1
I I I
I I I
I I I
I i I i
I I I I
I I I
I I
I I I
_1_J _1_J
I I I I
I I I
I I
I I I
I I I I
I I I
I
I I I I
I I 1
I
I I
I I
11 I
I
120
I I 1 I
I I I I
I I I I
I I
I l l l
I I
1 I
I I I I
1 I
I I I I
I I I I
( 1 I
1 I
I I I I
I I I
100
I I I
1
1 1 I
1 I
1 11
-r-T----r--1--r--1--
I I I I
I I I I
I I l
I I I
I I I
II
I
11 I
I 1 I
i
I I I
I I I I
1 I
a
I I I
I I
I I I I
I I I I
11
I I I I
I
I
I I
1 I
I I I
I
I 11 I
I I I I
I I I
I I I I
I
I I 1
I I I I
I 1
I I
I I
I I I
I 1 11
II I I
I I 1
I I 1 1
I I
I I I
1 11
1 1
I I I
I I
I I I I
1 I i I
I
zo
I
I I
0
1 I I i
I I I
1 I I
I
l
I I I I
I
1
0
50
I I I I
I I I
I I
I I
1
I
I
I,
4tl
--I-- y _I _Y
_1
r I 1
1 1 1
I I I I
1
11 1 1
1 I
11
1
I 11
11 1 I
1 1
11 L
11 1 1
I I
I I I I
I
I I
I 11
1 1
I I I
ng
I I I
I I
1
11 1 1
11
I 1 1
i
t I I
1 1
I
1
1 1
1 1 I 1
I I
1 I
I
1 1 1
I I I I
f 1 I I
I I I I
I I I I
I I
f I
I I
I I I I
I
1 1 1
I I I I
I
11 1
I
I I I I
I I
I I
11
1 I
I I
I I
I I
I I
I I I
I I I
I 1 1
I I I
I I I
I I
I I I
I I I
I I
I 1
I I
I I I
I I I
I
I I I
1
I
I I
I I
fi0_T____T__I__T__I__
__r
I I I
I I I I
I I
I I
I I I
I
I I I I
I I I
11 I
I I
I
I i I
I I I I
I I I I
140
I I I I
I I I I
I I I
I I I
I I I
I
I I I
I
I I I
I I I
I I
I
I I I
I
1 1
I I
I I I
I
1
1 1 1
1 1 1
i
I
1 I
1 1
i
I I I
1 1
I I
1 1
I I 1 1
I
I I I I
1 I
I I I I
100
I I I
1
I l i
I I I I
I
1 I 1
I I I I
I 11
I I I
1 1
11 1
1
I I
1 1
- 1
I
a
I 1
1
1
1
i
1
I
I
I
I I 1
0,
I I
11
I I I I
1 I I
I I I
I I I
I I
I
1 I it I
I 1 I
I I I
1 I
I I
I I
I I
I I I
1
I I I I
I I
I
to
I 1
1 1 I
1 I r
1
1 1
1
1 I
I I
I
I 1
I
I I I I
1 I
I I
1____
I
I I
I I I
1 I 1 1
I
1
I i
I I I
o
I
I I
I I
I 11
1 I 1
1 I
I I I I
1 1 1
1
i i 1
B+T Group
1717 S: Boulder, Suite
a.T GRP Tulsa, OK 74119
Phone: (918) 587-4630
- FL WEST FORT PIERCE, FL (BU# 81381
TIA-222-H - Service - 60 mph
Maximum Values
a
C
O
i+
N
W
Deflection (in)
I � I
24
_. r____I_____r
I I �
1 1 1 1
1 I 1
I I 1
no 1 _J____ L1____
I I 1 1
i I i r
I 1 1
� 1 1
zoo 1 1
1 I
1 I I I
� I I
I I
I
I I I
160
1
1 1
I I 1 1
1
1 �
1 1
60
I 1
I 1 1
� 1
� 1
1 � �
I 1
1 1 I
1
1
� 1
1 � 1
1 I
120
1. 1
1 1
1
1 I �
a6
1 1 I I
1 1 1 1
1 I 1
� I
� 1 �
6 1
1 1 I I
1 I 1 I
1 I
� 1 �
I 1 I
6 1
1 I 1 I
I I �
1 � I
4
---------------------
1 1 1 1
I 1 1 I
I 1 1 1
1 1 1 1
1 1 1
zo 1
1
1
1
I
i 1
i 1 1 1
Tilt (deg)
I I I I
I I I I
I I I I
I I I I
I I J I
I I I I
I I I I
I I I I
_I_ J_ 1_ L___I_
I I I I
I I I I
I I
I I II
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
J_ L_L_
I I I I
I I I I
I I
I I F I
I I I I
I I I I
I I I
I I I I
I I I I
I I I I
I I I I
J_1_L_I_
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I
I I I I
I I I I
I I I I
{-
I I I I
I I I I
I I I I
I
-I-7-rr---I--I-
I I I I
I I I I
I I I I
I t. I I
i I- T-I ---I-
I I I I
I I I I
I I
-r---I-rr-I-
I I I I
I I I I
I I I I
I I I I
I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I
I I I I
I I I I
I I I I
I I I i
I I I I
I I I I
I I I I
_I-J_1_L_
I I I I
I I I I
I I I
I I I I
I I I• I
I I I
I I I I
I I I I
J_1_ L_L__J_1
I I I I
I I I I
I I I I
I I I I
I I I I
I l f l
I I I I
I I I I
_ L _I_
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I
-I-7- -r---ry-r-r--7-r-r-I-
I I I I
I I I I
I I I I
I I I I
I I I I
I I I
I I I I
I I I I
11 1
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
1 1 1 1
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
1717 S. Boulder, Suite
3•T GRP Tulsa, OK 74119
Phone: (918) 5874630
Castle
Twist
I I I I I I I I
T I
I I I I I I I I
I I I I I I I I
I I I I I i I
I I I I I I I I
I I I I I I I I
I I I I I I i I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I
I I I I I I I I
I I I I I I I I
--I- T--r--I----r--I--t--r-
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
--I- T--j `-I-- _-r--I--T--j _
I I I I I I I 1
I I 1 I I I I I
I I i I I I I i
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I
I I I I I I I
I I I I I I I 1
1
I I I I I I I I
I I I I I I I i
I I I I I I I I
-r-r-r--l----r-7--r--r-
I I I I I I I I
I I I I I I I I
I I I I I I 1 1
I I I I I I I i
I I I I I I I I
I I I I I I I 1
I I I I I I I I
I I I I I I I I
1 I I I I I I i
I I I I I I I I
I I I I I I I I
1 I I I I I I I
I I I I I I I I
FL
Feed Line Distribution Chart
0' - 250'
Round Flat APP In Fam f_ APP OO Face , Tmsa Leg
Face A
x
O
d
W
Face B
-4/
6
o
�
j
---------------------------
__
______
V
_____
______
__
B+T Group
1717 S. Boulder, Suite
e-T GRP Tulsa, OK 74119
Phone: (918) 5B7.4830
Face C
----------------------
----------------------
----------------- ---f--
---------------
------------------------
I
v
-FL WESTFOR7
-}
FL
tnxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
1 of 39
Project
Date
B+T Group
1717 S Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle -
Kiran
FAX: (918) 295-0265
Tower Input Data
The main tower is a 3x freestanding tower with an overall height of 250' above the ground line.
The base of the tower is set at an elevation of 0' above the ground line.
The face width of the tower is Gat the top and 30' at the base.
This tower is designed using the TIA-222-H standard.
The following design criteria apply:
Tower base elevation above sea level: 19'.
Basic wind speed of 157 mph.
Risk Category II.
Exposure Category C.
Simplified Topographic Factor Procedure for wind speed-up calculations is used.
Topographic Category: I.
Crest Height: 0'.
Deflections calculated using a wind speed of 60 mph.
TIA-222-H Annex S.
Pressures are calculated at each section.
Tower analysis based on target reliabilities in accordance with Annex S.
Load Modification Factors used: Kes(F,v) = 0.95.
Stress ratio used in tower member design is 1.05.
Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered.
Consider Moments — Legs
Consider Moments - Horizontals
Consider Moments - Diagonals
Use Moment Magnification
Use Code Stress Ratios
Use Code Safety Factors - Guys
Escalate Ice
Always Use Max Kz
Use Special Wind Profile
Include Bolts hi Member Capacity
Leg Bolts Are At Top Of Section
Secondary Horizontal Braces Leg
Use Diamond Inner Bracing (4 Sided)
SR Members Have Cut Ends
SR Members Are Concentric
Options
Distribute Leg Loads As Uniform
Assume Legs Pinned
Assume Rigid Index Plate
Use Clear Spans For Wind Area
Use Clear Spans For KL/r
Retemion Guys To Initial Tension
Bypass Mast Stability Checks
Use Azimuth Dish Coefficients
Project Wind Area of Appurt.
Autocalc Torque Arm Areas
Add IBC .6D+W Combination
Sort Capacity Reports By Component
Triangulate Diamond Inner Bracing
Treat Feed Line Bundles As Cylinder
Ignore KL/ry For 60 Deg. Angle Legs
Use ASCE 10 X-Brace Ly Rules
J Calculate Redundant Bracing Forces
Ignore Redundant Members in PEA
J SR Leg Bolts Resist Compression
All Leg Panels Have Same Allowable
Offset Girt At Foundation
4 Consider Feed Line Torque
J Include Angle Block Shear Check
Use TIA-222-H Bracing Resist. Exemption
Use TIA-222-H Tension Splice Exemption
l- Poles
Include Shear -Torsion Interaction
Always Use Sub -Critical Flow
Use Top Mounted Sockets
Pole Without Linear Attachments
Pole With Shroud Or No Appurtenances
Outside and Inside Comer Radii Are
Known
MxTower
ob
J 77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
2 of 39
Project
Date
14:12:19 01 /23/19
B+T Group
1717 S Boulder, Suite 300
Client
Designed by
Tulsa, OK 74119
Phone: (918)587-4630
FAX. (918) 295-0265
Crown Castle
Kiran
Wind 180
1
r Lea A
Wind 90
Leg C Z Leg B
� r
Face C
Wind Normal
Triangular Tower
Tower Section Geometry
Tower . Tower Assembly Description Section Number Section
Section Elevation Database Width of Length
Sections
T1
250'-240'
6'
1
10,
T2
240'-220'
6'
1
20'
T3
220'-200'
8'
1
20'
T4
200'-180,
10,
1
20'
T5
180'-160'
12'
1
20'
T6
160'-140'
14'
1
20'
T7
140'-120'
16'
1
20'
T8
120'-100'
18'
1
20'
T9
100'-80,
20,
1
20'
T10
80'-60'
2T
1
20'
TI1
60'-40'
24'
1
20,
T12
40'-20'
26'
l
20'
T13
20'-0'
28'
1
20'
Tower Section Geometry cont'd
Tower
Tower
Diagonal
Bracing
Hits
Has
Top Girt
Bottom Girt
Section
Elevation
Spacing
Type
KBrace
Horizontals
Offset
Offset
End
ft
ft
Panels
in
in
TI
250'-240'
5'
XBruce
No
No
0.000
0.000
T2
240'-220'
6'8"
XBruce
No
No
0.000
0.000
MxTower
Job
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
3 of 39
B+T Group
1717 S. Boulder, Suite 300
Project
Date
14:12:19 01 /23/19
Tulsa OK 74119
Phone: (918) 587-4630
FAX.. (918) 295-0265
Client
Crown Castle
Designed by
Kiran
Tower
Tower
Diagonal
Bracing
Has
Has
Top Girt
Bottom Girt
Section
Elevation
Spacing
Type
KBrace
Horizontals
Offset
Offset
End
%t
ft
Panels
in
in
T3
220'-200'
6'8"
X Brace
No
No
0.000
0.000
T4
200'-180'
6'8"
X Brace
No
No
0.000
0.000
TS
180'-160'
5'
Double K
No
Yes
0.000
0.000
T6
160'-140'
5'
Double K
No
Yes
0.000
0.000
T7
140'-120'
5'
Double K
No
Yes
0.000
0.000
T8
120'-I00'
5'
Double K
No
Yes
0.000
0.000
T9
100'-80,
5'
Double K
No
Yes
0.000
0.000
T10
80'-60'
10,
.Double Kl
No
Yes
0.000
0.000
T11
60'40'
10,
Double Kl
No
Yes
0.000
0.000
T12
40'-20'
10,
Double Kl
No
Yes
0.000
0.000
T13
20'-0'
10,
Double KI
No
Yes
0.000
0.000
Tower Section Geometry cont'd
Tower
Leg
Leg
Leg
Diagonal
Diagonal
Diagonal
Elevation
Type
Size
Grade
Type
Site
Grade
ft
T1250'-240'
Solid Round
2
A572-50
Equal Angle
L2x2x3/16
A36
(50 ksi)
(36 ksi)
T2240'-220'
Solid Round
21/2
A572-50
Equal Angle
L21/2x212x3/16
A36
(50 ksi)
(36 ksi)
13.220'-200'
Solid Round
3
A572-50.
Equal Angle
L212x212x3/16
A36
(50 ksi)
(36 ksi)
T4200'-180'
Solid Round
31/4
A572-50
Equal Angle
L3x3x3/16
A36
(50 ksi)
(36 ksi)
T5180'-160'
Solid Round
31/4
A572-50
Double Angle
2L21/2x2120/160/8
A36
(50 ksi)
(36 ksi)
T6160'-140'
Solid Round
31/2
A572-50
Double Angle
2L21/2x212x3/16x3/8
A36
(50 ksi)
(36 ksi)
T7 140'-120'
Solid Round
3 3/4
A572-50
Double Angle
2L2 12x2 12x3/16x3/8
A36
(50 ksi)
(36 ksi)
T8120'-100'
Solid Round
4
A572-50
Double Angle
2L3x3x3/16x3/8
A36
(50 ksi)
(36 ksi)
T9100'-80'
Solid Round
41/4
A572-50
Double Angle
2L30x5/160/8
A36
(50 ksi)
(36 ksi)
T1080'-60'
Solid Round
412
A572-50
Double Angle
2L 00/16x3/8
A36
(50 ksi)
(36 ksi)
T1160'-40'
Solid Round
43/4
A572-50
Double Angle
2L3x3x3/16x3/8
A36
(50 ksi)
(36 ksi)
T1240'-20'
Solid Round
43/4
A572-50
Double Angle
2L3x3xl/4x3/8
A36
(50 ksi)
(36 ksi)
T1320'-0'
Solid Round
5
A572-50
Double Angle
2L3x3xl/4x3/8
A36
(50 ksi)
(36 ksi)
Tower Section Geometry cont'd
Tower
Top Girt
Top Girt
Top Girt
Bottom Girt
Bottom Girt Bottom Girt
Elevation
Type
Size
Grade
Type
Size Grade
ft
TI 250'-240'
Single Angle
L2x2x3/16
A36
Flat Bar
A36
(36 ksi)
(36 ksi)
tnxTower
Job
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
4 of 39
+T Gro
Bup
Project
Date
1717 S. Boulder, Suite 300
14:12:19 Ol /23l19
Client
Designed by
Tulsa, OK 74119
Phone: (918) 587-4630
Crown Castle
Kiran
FAX: (918) 295-0265
Tower Section Geometry cont'd
Tower
No.
Mid Girt
Mid Girt Mid Girt
Horizontal
Horizontal
Horizontal
Elevation
of
Type
Size Grade
Type
Size
Grade
Mid
f
Guts
T5180'-160'
None
Flat Bar
A36
Equal Angle
L2x2x3/16
A36
(36 ksi)
(36ksi)
T6160'-140'
None
Flat Bar
A36
Equal Angle
L212x2120/16
A36
(36 ksi)
(36 ksi)
T7140'-120'
None
Flat Bar
A36
Equal Angle
L3x3x3/16
A36
(36 ksi)
(36 ksi)
T8120'-100'
None
Flat Bar
A36
Equal Angle
L3x3x3/16
A36
(36 ksi)
(36 ksi)
79100'-80'
None
Flat Bar
A36
Equal Angle
L3x3xl/4
A36
(36 ksi)
(36 ksi)
T1080'-60'
None
Flat Bar
A36
Double Angle
2L212x212x3/16x3/8
A36
(36 ksi)
(36 ksi)
T1160'40'
None
Flat Bar
A36
Double Angle
2L212x2120/160/8
A36
(36 ksi)
(36 ksi)
T1240'-20'
None
Flat Bar
A36
Double Angle
2L212x212x3/16x3/8
A36
(36 ksi)
(36 ksi)
T13 20'-0'
None
Flat Bar
A36
Double Angle
2L3x3x3/16x3/8
A36
(36 ksi)
(36 ksi)
Tower Section Geometry cont'd
Tower
Secondary Secondary Horizontal
Secondary
Inner Bracing
Inner Bracing Size
Inner Bracing
Elevation
Horizontal Type Size
Horizontal
Type
Grade
Grade
n
T5180'-160'
Single Angle
A36
Equal Angle
L2x2x3/16
A36
(36 ksi)
(36 ksi)
T6160'-140'
Single Angle
A36
Equal Angle
L2x2x3/16
A36
(36 ksi)
(36 ksi)
17 140'-120'
Single Angle
A36
Equal Angle
L2 12x2 12x3/16
A36
(36 ksi)
(36 ksi)
T8120'-100'
Single Angle
A36
Equal Angle
L21/2x2120/16
A36
(36 ksi)
(36 ksi)
T9100'-80'
Single Angle
A36
Equal Angle
L3x3x3/16
A36
(36 ksi)
(36 ksi)
T10 80'-60'
Single Angle
A36
Double Angle
2L2x2x3/16x3/8
A36
(36 ksi)
(36 ksi)
Tl1 60'40'
Single Angle
A36
Double Angle
2L2x2x3/16x3/8
A36
(36 ksi)
(36 ksi)
T1240'-20'
Single Angle
A36
Double Angle
2L212x212x3/16x3/8
A36
(36 ksi)
(36 ksi)
T1320'-0'
Single Angle
A36
Double Angle
2L211W 1/2x3/16x3/8
A36
(36 ksi)
(36 ksi)
MxToweY
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
5 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23119
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
IClran
FAX (918) 295-0265
Tower Section Geometry cont'd
Tower
Elevation
Redundant
Bracing
Grade
Redundant
Type
Redundant
Size
KFactor
T1080'-60'
A36
Horizontal (1)
Double Angle
2L2x2x3/16x3/8
1
(36 ksi)
Diagonal (1)
Double Angle
2L2x2x3/16x3/8
1
Hip (1)
Equal Angle
L2 1/2x2 1/2x3/16
1
T1160'40'
A36
Horizontal (1)
Double Angle
2L2x2x3/16x3/8
l
(36 ksi)
Diagonal (1)
Double Angle
2L2x2x3/16x3/8
1
Hip (1)
Equal Angle
L2 1/2x2 1/2x3/16
l
T1240'-20'
A36
Horizontal (1)
Double Angle
2L2x2x3/16x3/8
1
(36 ksi)
Diagonal (1)
Double Angle
2L2x2x3/16x3/8
1
Hip (1)
Equal Angle
L2 1/2x2 1/20/16
1
T13 20'-0'
A36
Horizontal (1)
Double Angle
2L2x2x3/16x3/8
1
(36 ksi)
Diagonal (1)
Double Angle
2L2x2x3/16x3/8
1
Hip (1)
Equal Angle
L2 1/2x2 1/2x3/16
1
Tower Section Geometry
cont'd
Double Angle Double Angle Double Angle
Tower
Gusset
Gusset
Gusset Grade Adjust. Factor
Adjust Weight Mult.
Elevation
Area
Thickness
AI
Factor
Stitch Bolt
Stitch Bolt
Stitch Bolt
(perforce)
A,
Spacing
Spacing
Spacing
'
Diagonals
Horizontals
Redundants
ft
flt
in
in
in
in
T1 250'-240'
0.000
0.000
A36
1.05
1
1.05
Mid -Pt
Mid -Pt
Mid -Pt
(36 ksi)
T2 240'-220'
0.000
0.000
A36
1.05
1
1.05
Mid -Pt
Mid -Pt
Mid -Pt
(36 ksi)
T3 220'-200'
0.000
0.000
A36
1.05
1
1.05
Mid -Pt
Mid -Pt
Mid -Pt
(36 ksi)
T4200'-180'
0.000
0.000
A36
1.05
1
1.05
Mid -Pt
Mid -Pt
Mid -Pt.
(36 ksi)
T5 180'-160'
0.000
0.000
A36
1.05
I
1.05
Mid -Pt
Mid -Pt
Mid -Pt
(36 ksi)
T6 160'-140'
0.000
0.000
A36
1.05
1
1.05
Mid -Pt
Mid -Pt
Mid -Pt
(36 ksi)
T7 140'-120'
0.000
0.000
A36
1.05
1
1.05
Mid -Pt
Mid -Pt
Mid -Pt
(36 ksi)
'
T8 120'-100'
0.000
0.000
A36
1.05
1
1.05
Mid -Pt
Mid -Pt
Mid -Pt
(36 ksi)
179100'-80'
0.000
0.000
A36
1.05
1
1.05
Mid -Pt
Mid -Pt
Mid -Pt
(36 ksi)
TO 80'-60'
0.000
0.000
A36
1.05
1
1.05
46.140
Mid -Pt
Mid -Pt
(36 ksi)
T1160'40'
0.000
0.000
A36
1.05
1
1.05
48.460
Mid -Pt'
Mid -Pt
(36 ksi)
T1240'-20'
0.000
0.000
A36
1.05
1
1.05
50.890
Mid -Pt
Mid -Pt
(36 ksi)
T1320'-0'
0.000
0.000
A36
1.05
1
1.05
53.340
Mid -Pt
Mid -Pt
Tower Section Geometry cont'd
KFactors'
MxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
6 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Client
Designed by
Tulsa, OK 74119
Phone: (918) 587-4630
Crown Castle
Kiran
FAX..- (918) 295-0265
Tower Cale
Cale
Elevation K
K
Single
Solid,
Angles
Rounds
Legs X
K
Single
Girts Horiz.
Sec.
Inner
Brace
Brace
Diags
Hariz.
Brace
Diags
Diags
X
X
X
X X
X
X
Y
Y
Y
Y Y
Y
Y
T1250'-240'
Yes
Yes
1
1
1
I
1
I
1
1
I
1
I
1
l
1
1
T2 240'-220'
Yes
Yes
1
1
1
1
I
1
1
1
1
1
1
1
1
1
1
T3 220'-200'
Yes
Yes
l
1
1
1
1
1
I
1
1
1
1
1
1
1
1
T4 200'-180'
Yes
Yes
l
1
1
1
1
1
1
1
1
1
1
1
1
1
1
T5180'-160'
Yes
Yes
1
1
1
1
1
1
1
1
1
1
l
1
1
1
1
T6160'-140'
Yes
Yes
1
1
I
1
l
I
1
I
1
1
1
l
1
1
I
17140'-120'
Yes
Yes
1
1
1
1
1
1
1
1
1
I
1
1
1
1
1
T8120'-I00'
Yes
Yes
1
I
1
1
1
1
1
1
l
1
1
1
1
1
1
T9100'-80'
Yes
Yes
1
I
1
1
1
1
1
1
1
1
1
1
1
1
1
T10 80'-60'
No
Yes
1
1
l
1
1
1
1
I
•
1
0.5
1
1
l
1
1
T1160'-40'
No
Yes
1
1
1
1
1
1
1
1.
I
0.5
1
1
1
1
1
T1240'-20'
No
Yes
1
1
1
1
1
1
I
1
1
0.5
1
I
1
1
1
T13 20'-0'
No
Yes
I
I
1
1
1
1
1
1
I
0.5
1
1
1
1
1 '
'Note: Kfactors are applied to member segment lengths. K-braces without inner supporting members will have the Kfactor in the out -of -plane direction applied to
the overall length
Tower Section Geometry cont'd
Tower
Elevation
i
Leg
Diagonal
Top Girt
Bottom Girt
Mid Girt
Long Horizontal
Short Horizontal
Net Width
U
Net Width
U
Net Width
U
Net
U
Net
U
Net
U
Net
U
Deduct
Deduct
Deduct
Width
Width
Width
Width
in
in
in
Deduct
Deduct
Deduct
Deduct
in
in
in
in
T1 250'-240'
0.000
I
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T2 240'-220'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T3 220'-200'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T4 200'-180'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T5 IW-160'
0.000
1
-0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T6 160'-140'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T7 140'-120'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T8 120'-100'
0.000
I
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T9 100'-80,
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T10 80'-60'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T11 60'40'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T12 40'-20'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T13 20'-0'
1 0.000
1
1 0.000
0.75
1 0.000
0.75
1 0.000
0.75
1 0.000
0.75
1 0.000
0.75
1 0.000
0.75
Mxl owe%'
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
7 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone., (918) 5874630
Crown Castle
Kiran
FAX. (918) 295-0265
Tower Section Geometry cont'd
Tower
Elevation
ft
Leg
Connection
Type
Leg
Bolt Size
No.
Diagonal
Top Girt
Bottom Girt
Mid Girt
Long Horizontal
Short Horizontal
Bolt Size No.
Bolt Size No.
Bolt Size No.
Bolt Size No.
Bolt Size No.
Bolt Size
No.
in
in
in
in
in
in
in
T1 250'-240'
Flange
0.625
4
0.625
2
0.625
1
0.000
0
0.625
0
0.000
0
0.625
0
A325N
A325N
A325N
A325N
A325N
A325N
A325N.
T2 240'-220'
Flange
0.625
6
0.625
2
0.000
0
0.000
0
0.625
0
0.000
0
0.625
0
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T3 220'-200'
Flange
0.875
6
0.625
2
0.000
0
0.000
0
0.625
0
0.000
0
0.625
0
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T4 200'-180'
Flange
1.000
6
0.625
2
0.000
0
0.000
0
0.625
0
0.000
0
0.625
0
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T5 180'-160'
Flange
1.000
6
0.625
2
0.000
0
0.000
0
0.625
0
0.625
1
0.625
1
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T6 160'-140'
Flange
1.000
6
0.625
2
0.000
0
0.000
0
0.625
0
0.625
1
0.625
1
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T7 140'-120'
Flange
1.125
6
0.625
2
0.000
0
0.000
0
0.625
0
0.625
1
0.625
1
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T8 120'-100'
Flange
1.250
6
0.625
2
0.000
0
0.000
0
0.625
0
0.625
1
0.625
1
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T9 100'-80,
Flange
1.250
6
0.625
2
0.000
0
0.000
0
0.625
0
0.625
1
0.625
1
A325N
A325X
A325N
A325N
A325N
A325N
A325N
T10 80'-60'
Flange
1.375
6
0.625
2
0.000
0
0.000
0
0.625
0
0.625
1
0.625
1
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T1160'40'
Flange
1.500
6
0.625
2
0.000
0
0.000
0
0.625
0
0.625
1
0.625.
1
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T12 40'-20'
Flange
1.500
6
0.625
2
0.000
0
0.000
0
0.625
0
0.625
1
0.625
1
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T13 20'-0'
.Flange
2.250
0
0.625
2
0.000
0
0.000
0
0.625
0
0.625
1
0.625
1
A36
I A325N
I A325N
I A325N
I A325N
I A325N
I A325N
Feed Line/Linear Appurtenances - Entered As Round Or Flat
Description Face Allow Exclude Component Placement Face Lateral # # Clear Width or Perimeter Weight
or Shield From Type Offset Offset Per Spacing Diameter
Leg Torque ft in (Frac 1799 Row in in in k1f
LDF7-50A(1- B No
5/8)
(E)
Feedline B No
Ladder (At)
(E)
*rKs-
LCF158-501(1 A No
-5/8)
(E)
LCF158-501(1 A No
-5/8)
(E)
LCF158-501(1 A No
-5/8)
(E)
LCF158-501(1 A No
No
At (CaAa)
243' - 0'
0.000
0.4
13
7
0.850
1.980
0.750
No
Af (CaAa)
243' - 0'
0.000
0.4
1
1
3.000
3.000
No
Ar (CaAa)
143' - 0'
0.000
-0.45
2
2
0.850
2.010
0.750
No
Ar (CaAa)
143' - 0'
0.000
-0.4
5
4
0.850
2.010
0.750
No
At (CaAa)
143' - 0'
0.000
-0.36
3
1
0.850
2.010
0.750
No
At (CaAa)
143' - 0'
0.000
-0.34
2
2
0.850
2.010
0.001
0.008
0.001
0.001
0.001
0.001
tnxTower
ob
d 77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
8 of 39
B+T Group
1717 S. Boulder, Suite 300
Project
Date
14:12:19 01 /23/19
Client
Designed by
Tulsa, OK 74119
Phone: (918)587-4630
FAX.- (918) 295-0265
Crown Castle
Kiran
Description
Face Allow
or Shield
Leg
Exclude
From
Torque
Calculation
Component
Type
Placement
ft
Face
Offset
in
Lateral
Offset
(Frac FW)
#
# Clear Width or Perimeter
Per Spacing Diameter
Row in in in
Weight
klf
-5/8)
0.750
(E)
WR-VG86ST-
A
No
No
At (CaAa)
143'-0'
0.000
-0.32
6
4
0.850
0.795
0.001
BRD(3/4)
0.750
(2E+4P)
FB-L98B-034-
A
No
No
At (CaAa)
143' - 0'
3.000
-0.32
4
4
0.850
0.394
0.000
XXX(3/8)
0.750
(3P+IP(5/16))
Feedlioe
A
No
No
Af (CaAa)
250' - 0'
0.000
-0.38
1
1
3.000
3.000
0.008
Ladder (At)
(E)
ssK««
TSZ 999
A
No
No
At (CaAa)
130' - 0'
0.000
0.4
3
2
0.850
1.039
0.001
066DOOCM-8
0.750
AWG(1-1/32)
FIBER ONLY
A
No
No
At (CaAa)
130' - 0'
0.000
0.39
1
1
0.850
0.867
0.000
CABLE
0.750
48(7/8)
Feedlioe
A
No
No
Af (CaAa)
130' - 0'
0.000
0.42
1
1
3.000
3.000
0.008
Ladder (At)
(E)
Ks -
Climbing
B
No
No
At (CaAa)
250'- 0'
0.000
0
1
1
3.840
3.840
0.005
Ladder ( Flat)
(E)
Safety Line
B
No
No
At (CaAa)
250' - 0'
0.000
0
I
1
0.375
0.375
0.000
3/8
(E)
««K««
Feedline
C
No
No
Af (Caka)
145' - 0'
0.000
-0.4
1
I
3.000
3.000
0.008
Ladder (Af)
(Empty)
Feedline
C
No
No
Af (CaAa)
145' - 0'
0.000
-0.425
1
1
3.000
3.000
0.008
Ladder (At)
(Empty)
««g««
Light Chord
C
No
No
At (CaAa)
12T - 0'
0.000
0.5
2
2
0.500
0.630
0.000
(E)
Light Chord
C
No
No
At (CaAa)
250' - 125'
0.000
0.5
1
1
0.500
0.630
0.000
(E)
Ks -
Feed Line/Linear Appurtenances - Entered As Area
Description Face Allow Exclude Component Placement Total CAS Weight
or Shield From Type Number
Leg Torque ft ftt/ft k1f
Calculation
tnxTower
J°b
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
9 of 39
Project
Date
B+T Group
1717S. Boulder, Suite 300
14:12:19 01/23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 5874630
Crown Castle
Kiran
FAX.- (918) 295-0265
Feed Line/Linear Appurtenances Section Areas
Tower
Tower
Face
Are
Ar
CiAA
Cyla
Weight
Section
Elevation
' In Face
Out Face
jt
S+t
fit,
jt'
Jz=
K
Tl
250'-240'
A
0.000
0.000
5.000
0.000
0.084
B
0.000
0.000
15.997
0.000
0.107
C
0.000
0.000
0.630
0.000
0.002
12
240'-220'
A
0.000
0.000
10.000
0.000
0.168
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
1.260
0.000
0.003
T3
220'-200'
A
0.000
0.000
10.000
0.000
0.168
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
1.260
0.000
0.003
T4
200'-180'
A
0.000
0.000
10.000
0.000
0.168
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
1.260
0.000
0.003
T5
180'-160'
A
0.000
0.000
10.000
0.000
0.168
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
1.260
0.000
0.003
T6
160'-140'
A
0.000
0.000
19.139
0.000
0.212
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
6.260
0.000
0.087
T7
140'-120'
A
0.000
0.000
79.914
0.000
0.571
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
21.575
0.000
0.340
T8
120'-100'
A
0.000
0.000,
88.898
0.000
0.679
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
22.520
0.000
0.342
T9
100'-80,
A
0.000
0.000
88.898
0.000
0.679
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
22.520
0.000
0.342
T10
80'-60'
A
0.000
0.000
88.898
0.000
0.679
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
22.520
0.000
0.342
T11
60'40'
A
0.000
0.000
88.898
0.000
0.679
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
22.520
0.000
0.342
T12
40'-20'
A
0.000
0.000
88.898
0.000
0.679
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
22.520
0.000
0.342
T13
20'-0'
A
0.000
0.000
88.898
0.000
0.679
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
22.520
0.000
0.342
Feed Line Center of Pressure
Section
Elevation
CPx
CPr
CPx
CPi
Ice
Ice
It
in
in
in
in
TI
250'-240'
1.935
1.902
1.935
1.902
- 72
240'-220'
7.981
5.424
7.970
5.417
T3
220'-200'
9.149
6.532
9.042
6.459
T4
200'-180'
9.321
7.002
9.186
6.902
T5
180'-160'
11.094
8A28
10.923
8.301
T6
160'-140'
8.876
10.922
8.717
10.728
T7
140'-120'
-4A76
14.315
-4.404
14.087
T8
120'-100'
-4.982
11.657
-4.897
11.458
T9
100'-80,
-5.225
12.385
-5.124
12.142
tnXTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
10 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Client
Designed by
Tulsa, OK 74119
Phone: (918) 587-4630
Crown Castle
Kiran
FAX (918) 295-0265
Section Elevation CPx CPz CPx CPz
Ice Ice
Tll 60'40' -6.338 15.097 -6.166 14.685
T12 40'-20' -6.596 15.842 -6.444 15.471
T13 20'-0' -6.711 16.272 -6.565 15.911
Shielding Factor Ka
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment El"
K.
No Ice
K.
Ice
TI
2
LDF7-50A(1-5/8)
240100-
0.6000
0.6000
243.00
TI
4
Feedline Ladder (Af)
240.00-
0.6000
0.6000
243.00
T1
16
Feedline Ladder (At)
240.00-
0.6000
0.6000
250.00
TI
22
Climbing Ladder ( Flat)
240.00-
0.6000
0.6000
250.00
TI
23
Safety Line 3/8
240.00-
0.6000
0.6000
250.00
T1
29
Light Chord
240.00-
0.6000
0.6000
250.00
T2
2
LDF7-50A(1-5/8)
220.00-
• 0.6000
0.6000
240.00
T2
4
Feedline Ladder (At)
220.00-
0.6000
0.6000
240.00
72
16
Feedline Ladder (At)
220.00-
0.6000
0.6000
240.00
72
22
Climbing Ladder ( Flat)
220.00-
0.6000
0.6000
240.00
T2
23
Safety Line 3/8
220.00-
0.6000
0.6000
240.00
T2
29
Light Chord
220.00-
0.6000
0.6000
240.00
T3
2
LDF7-SOA(I-5/8)
200.00-
0.6000
0.6000
220.00
73
4
Feedline Ladder (At)
200.00-
0.6000
0.6000
220.00
T3
16
Feedline Ladder (At)
200.00-
0.6000
0.6000
220.00
- T3
22
Climbing Ladder ( Flat)
200.00-
0.6000
0.6000
220.00
T3
23
Safety Line 3/8
200.00-
0.6000
0.6000
220.00
T3
29
Light Chord
200.00-
0.6000
0.6000
220.00
T4
2
LDF7-50A(1-5/8)
180.00-
0.6000
0.6000
200.00
T4
4
Feedline Ladder (At)
180.00 -
0.6000
0.6000
200.00
T4
16
Feedline Ladder (At)
180.00 -
0.6000
0.6000
200.00
T4
22
Climbing Ladder ( Flat)
180.00 -
0.6000
0.6000
200.00
T4
23
Safety Line 3/8
180.00 -
0.6000
0.6000
200.00
MxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
11 of 39
Project -
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX: (918) 295-0265
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment Elev.
Ka
No lee
K.
Ice
T4
29
Light Chord
180.00-
0.6000
0.6000
200.00
TS
2
LDF7-50A(1-5/8)
160.00-
0.6000
0.6000
180.00
T5
4
Feedline Ladder(A0
160.00-
0.6000
0.6000
180.00
T5
16
Feedline Ladder(A0
160.00-
0.6000
0.6000
180.00
T5
22
Climbing Ladder ( Flat)
160.00-
0.6000
0.6000
180.00
T5
23
Safety Line 3/8
160.00-
0.6000
0.6000
180.00
T5
29
Light Chord
160.00-
0.6000
0.6000
180.00
T6
2
LDF7-50A(1-5/8)
140.00-
0.6000
0.6000
160.00
T6
4
Feedline Ladder (At)
140.00-
0.6000
0.6000
160.00
T6
6
LCF158-50J(1-5/8)
140.00-
0.6000
0.6000
143.00
T6
7
LCF158-50J(1-5/8)
140.00-
0.6000
0.6000
143.00
T6
8
LCF158-50J(1-5/8)
140.00-
0.6000
0.6000
143.00
T6
9
LCF158-50J(1-5/8)
140.00-
0.6000
0.6000
143.00
T6
l0
WR-VG86ST-BRD(3/4)
140.00-
0.6000
0.6000
143.00
T6
14
FB-L98B-034-XXX(3/8)
140.00-
0.6000
0.6000
143.00
T6
16
Feedline Ladder (At
140.00-
0.6000
0.6000
160.00
T6
22
Climbing Ladder ( Flat)
140.00-
0.6000
0.6000
160.00
T6
23
Safety Line 3/9
140.00-
0.6000
0.6000
160.00
T6
25
Feedline Ladder (At)
140.00-
0.6000
0.6000
145.00
T6
26
Feedline Ladder (At)
140.00-
0.6000
0.6000
145.00
T6
29
Light Chord
140.00-
0.6000
0.6000
160.00
T7
2
LDF7-50A(1-5/8)
120.00-
0.6000
0.6000
140.00
T7
4
Feedline Ladder (At)
120.00-
0.6000
0.6000
140.00
T7
6
LCF158-50J(1-5/8)
120.00-
0.6000
0.6000
140.00
T7
7
LCF158-50J(1-5/8)
120.00-
0.6000
0.6000
140.00
T7
8
LCF158-50J(1-5/8)
120.00-
0.6000
0.6000
140.00
T7
9
LCF158-50J(1-5/8)
120.00-
0.6000
0.6000
140.00
T7
10
WR-VG86ST-BRD(3/4)
120.00-
0.6000
0.6000
140.00
T7
14
FB-L98B-034-XXX(3/8)
120.00-
0.6000
0.6000
140.00
T7
16
Feedline Ladder (At)
120.00-1
0.60001
0.6000
140.00
T7
18
TSZ 999
120.00 -
0.6000
0.6000
066/XXn1-8AWG(1-l/32)
130.00
MxTOWer
ob
J 77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
12 of 39
Project
Date
B+T Group
7717 S. Boulder, Suite 300
14:12:19 01 /23/19
Client
Designed by
. Tulsa, OK 74119
Phone. (918) 5874630
Crown Castle
Kiran
FAX..- (918) 295-0265
Tower
Section
Feedline
Record No.
Description
Feed Line
Segment Elev.
K.
No lee
K.
lee
T7
19
FIBER ONLY CABLE
120.00-
0.6000
0.6000
48(7/8)
130.00
T7
20
Feedline Ladder (Af)
120.00-
0.6000
0.6000
130.00
T7
22
Climbing Ladder ( Flat)
120.00-
0.6000
0.6000
140.00
T7
23
Safety Line 3/8
120.00-
0.6000
0.6000
140.00
T7
25
Feedline Ladder (At)
120.00-
0.6000
0.6000
140.00
77
26
Feedline Ladder (At)
120.00-
0.6000
0.6000
40.00
T7
28
Light Chord
120.00-
0.6000
0.6000
125.00
T7
29
Light Chord
125.00 -
0.6000
0.6000
140.00
T8
2
LDF7-50A(1-5/8)
100.00-
0.6000
0.6000
120.00
T8
4
Feedline Ladder (At)
100.00-
0.6000
0.6000
120.00
T8
6
LCF158-50J(1-5/8)
100.00-
0.6000
0.6000
120.00
T8
7
LCF158-50J(1-5/8)
100.00-
0.6000
0.6000
120.00
T8
8
LCF158-501(1-5/8)
100.00-
0.6000
0.6000
120.00
T8
9
LCF158-50J(1-5/8)
100.00-
0.6000
0.6000
120.00
T8
10
WR-VG86ST-BRD(3/4)
100.00-
0.6000
0.6000
120.00
T8
14
FB-L98B-034-XXX(3/8)
100.00-
0.6000
0.6000
120.00
T8
16
Feedline Ladder (At)
100.00-
0.6000
0.6000
120.00
T8
18
TSZ 999
100.00-
0.6000
0.6000
066/XXXM-8AWG(1-l/32)
120.00
T8
19
FIBER ONLY CABLE
100.00-
0.6000
0.6000
48(7/8)
120.00
T8
20
Feedline Ladder (At)
100.00-
0.6000
0.6000
120.00
T8
22
Climbing Ladder ( Flat)
100.00-
0.6000
0.6000
120.00
T8
23
Safety Line 3/8
100.00-
0.6000
0.6000
120.00
T8
25
Feedline Ladder (At)
100.00-
0.6000
0.6000
120.00
T8
26
Feedline Ladder (At)
100.00-
0.6000
0.6000
120.00
T8
28
Light Chord
100.00-
0.6000
0.6000
120.00
T9
2
LDF7-50A(1-5/8)
80.00-100.00
0.6000
0.6000
T9
4
Feedline Ladder (At)
80.00 - 100.00
0.6000
0.6000
T9
6
LCF158-50J(1-5/8)
80.00-100.00
0.6000
0.6000
T9
7
LCF158-50J(1-5/8)
80.00 - 100.00
0.6000
0.6000
T9
8
LCF158-50J(1-5/8)
80.00-100.00
0.6000
0.6000
T9
9
LCF158-50J(1-5/8)
80.00- 100.00
0.6000
0.6000
T9
10
WR-VG86ST-BRD(3/4)
80.00-100.00
0.6000
0.6000
T9
14
FB-L98B-034-XXX(3/8)
80.00- 100.00
0.6000
0.6000
T9
16
Feedline Ladder (At)
80.00 - 100.00
0.6000
0.6000
T9
18
TSZ 999
80.00 - 100.00
0.6000
0.6000
066/l XXM-8AWG(1-1/32)
T9
191
FIBER ONLY CABLE
80.00 - 100.00
0.6000
0.6000
tnxToweY
J°b
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
13 of 39
Project
Data
14:12:19 01 /23119
B4Group
1717 S. Boulder, Suite 300
Tulsa, OK 74119
Phone: (918) 5874630
FiLY.. (918) 295-0265
Client
Crown Castle
Designed by
Kiran
Traver
Section
Feed Line
Record No.
Description
Feed Line
Segment Elev.
Ka
No lee
K.
ice
48(7/8)
T9
20
Feedline Ladder (At)
80.00 - 100.00
0.6000
0.6000
T9
22
Climbing Ladder ( Flat)
80.00 - 100.00
0.6000
0.6000
T9
23
Safety Line 3/8
80.00 - 100.00
0.6000
0.6000
T9
25
Feedline Ladder (Af)
80.00 - 100.00
0.6000
0.6000
T9
26
Feedline Ladder (Ai)
80.00 - 100.00
0.6000
0.6000
T9
28
Light Chord
80.00 - 100.00
0.6000
0.6000
T10
2
LDF7-50A(1-5/8)
60.00-80.00
0.6000
0.6000
T10
4
Feedline Ladder (At)
60.00 - 80.00
0.6000
0.6000
T10
6
LCF158-50J(1-5/8)
60.00-80.00
0.6000
0.6000
T10
7
LCF158-50J(1-5/8)
60.00-80.00
0.6000
0.6000
T10
8
LCF158-50J(1-5/8)
60.00 - 80.00
0.6000
0.6000
T10
9
LCF158-50J(1-5/8)
60.00 - 80.00
0.6000
0.6000
T10
10
WR-VG86ST-BRD(3/4)
60.00-80.00
0.6000
0.6000
T10
14
FB-L98B-034-XXX(3/8)
60.00 - 80.00
0.6000
0.6000
T10
16
Feedline Ladder (At)
60.00 - 80.00
0.6000
0.6000
T10
18
TSZ 999
60.00 - 80.00
0.6000
0.6000
066/XXXM-8AWG(l-1/32)
T10
19
FIBER ONLY CABLE
60.00 - 80.00
0.6000
0.6000
48(7/8)
T10
20
Feedline Ladder (Af)
60.00 - 80.00
0.6000
0.6000
T10
22
Climbing Ladder ( Flat)
60.00 - 80.00
0.6000
0.6000
T10
23
Safety Line 3/8
60.00 - 80.00
0.6000
0.6000
T10
25
Feedline Ladder (Af)
60.00 - 80.00
0.6000
0.6000
T10
26
Feedline Ladder (At)
60.00 - 80.00
0.6000
0.6000
T10
28
Light Chord
60.00- 80.00
0.6000
0.6000
Tl1
2
LDF7-50A(1-5/8)
40.00-60.00
0.6000
0.6000
T11
4
Feedline Ladder (Af)
40.00 - 60.00
0.6000
0.6000
Tll
6
LCF158-50J(1-5/8)
40.00-60.00
0.6000
0.6000
TII
7
LCF158-50J(1-5/8)
40.00-60.00
0.6000
0.6000
Tll
8
LCF158-50J(1-5/8)
40.00-60.00
0.6000
0.6000
Till
9
LCF158-50J(1-5/8)
40.00-60.00
0.6000
0.6000
Tll
10
WR-VG86ST-BRD(3/4)
40.00-60.00
0.6000
0.6000
TI1
14
FB-L98B-034-XXX(3/8)
40.00 - 60.00
0.6000
0.6000
Tl 1
16
Feedline Ladder (At)
40.00 - 60.00
0.6000
0.6000
TII
18
TSZ 999
40.00 - 60.00
0.6000
0.6000
066OL OOv1-8AWG(1-I/32)
TII
.19
FIBER ONLY CABLE
40.00 - 60.00
0.6000
0.6000
48(7/8)
TII
20
Feedline Ladder (Af)
40.00 - 60.00
0.6000
0.6000
TII
22
Climbing Ladder ( Flat)
40.00 - 60.00
0.6000
0.6000
TII
23
Safety Line 318
40.00-60.00
0.6000
0.6000
T11
25
Feedline Ladder (Ai)
40.00 - 60.00
0.6000
0.6000
Tl1
26
Feedline Ladder (At)
40.00 - 60.00
0.6000
0.6000
TII
28
Light Chord
40.00 -60.00
0.6000
0.6000
T12
2
LDF7-50A(1-5/8)
20.00-40.00
0.6000
0.6000
T12
4
Feedline Ladder (At)
20.00 - 40.00
0.6000
0.6000
T12
6
LCF158-SOJ(1-5/8)
20.00 -40.00
0.6000
0.6000
T12
7
LCF158-50J(1-5/8)
20.00 -40.00
0.6000
0.6000
T12
8
LCF158-501(1-5/8)
20.00-40.00
0.6000
0.6000
T12
9
LCF158-50J(1-5/8)
20.00-40.00
0.6000
0.6000
T12
10
WR-VG86ST-BRD(3/4)
20.00-40.00
0.6000
0.6000
T12
14
FB-L98B-034-A^O{(3/8)
20.00-40.00
0.6000
0.6000
T12
16
Feedline Ladder (At)
20.00 - 40.00
0.6000
0.6000
T12
18
TSZ 999
20.00-40.00
0.6000
0.6000
066fXXX 4-8AWG(1-l/32)
T12
19
FIBER ONLY CABLE
20.00 - 40.00
0.6000
0.6000
48(7/8)
T12
20
Feedline Ladder (Af)
20.00 - 40.00
0.6000
0.6000
T12
22
Climbing Ladder(Fla[)
20.00 - 40.001
0.60001
0.6000
T12
23
Safety Line 3/8
20.00 - 40.00
0.6000
0.6000
TI2
25
Feedline Ladder (Af)
20.00 - 40.001
0.60001
0.6000
tnxTower
Job
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
14 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 Ol /23/19
Client
Designed by
Tulsa, OK 74119
Phone: (918) 5874630
Crown Castle
Kiran
FAX (918) 295-0265
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment Elev.
K.
No Ice
K.
Ice
T12
26
Feedline Ladder (At)
20.00 - 40.00
0.6000
0.6000
T12
28
Light Chord
20.00 -40.00
0.6000
0.6000
T13
2
LDF7-50A(I-5/8)
0.00-20.00
0.6000
0.6000
T13
4
Feedline Ladder (At)
0.00-20.00
0.6000
0.6000
T13
6
LCF158-50J(1-5/8)
0.00 -20.00
0.6000
0.6000
T13
7
LCF158-50J(1-5/8)
0.00 -20.00
0.6000
0.6000
T13
8
LCF158-501(1-5/8)
0.00 -20.00
0.6000
0.6000
T13
9
LCF158-50J(1-5/8)
0.00 -20.00
0.6000
0.6000
T13
10
WR-VG86ST-BRD(3/4)
0.00-20.00
0.6000
0.6000
T13
14
FB-L98B-034-XXX(3/8)
0.00-20.00
0.6000
0.6000
T13
16
Feedline Ladder (Af)
0.00 - 20.00
0.6000
0.6000
T13
18
TSZ 999
0.00 - 20.00
0.6000
0.6000
066/XXXM-8A WG(1-1/32)
T13
19
FIBER ONLY CABLE
0.00 - 20.00
0.6000
0.6000
48(7/8)
T13
20
Feedline Ladder (Af)
0.00 - 20.00
0.6000
0.6000
T13
22
Climbing Ladder (Flat)
0.00-20.00
0.6000
0.6000
T13
23
Safety Line 3/81
0.00-20.00
0.6000
0.6000
T13
25
Feedline Ladder(Af)
0.00 -20.00
0.6000
0.6000
T13
26
Feedline Ladder (At)
0.00 - 20.00
0.6000
0.6000
T13
28
Light Chord
0.00 - 20.00
0.6000
0.6000
Discrete Tower Loads
Description Face Offset Offsets: Azimuth Placement CFAs CAAA Weight
or Type Horz Adjustment Front Side
Leg Lateral
Vert
jt I+ It' It= K
Flash Beacon Lighting
C
From Leg
U.000
(E)
0'
1'
Side Lighting
A
From Leg
0.500
(E)
0'
0'
Side Lighting
B
From Leg
0.500
(E)
0'
0'
Side Lighting
C
From Leg
0.500
(E)
0'
0'
4' Dipole
B
From Leg
1.000
(E-PER PHOTO AND TIA)
0'
0'
4' Dipole
A
From Leg
1.000
(E-PER PHOTO AND TIA)
0'
0'
4' Dipole
B
From Leg
1.000
(E-PER PHOTO AND TIA)
0'
0'
4' Dipole
A
From Leg
1.000
(E-PER PHOTO AND TIA)
0'
0.000
249'6"
No Ice
2.700
2.700
0.050
0.000
125,
No Ice
0.133
0.133
0.005
0.000
125'
No Ice
0.133
0.133
0.005
0.000
125'
No Ice
0.133
0.133
0.005
0.000
234'
No Ice
1.393
1.393
0.035
0.000
215'
No Ice
1.393
1.393
0.035
0.000
191,
No Ice
1.393
1.393
0.035
0.000
177'
No Ice
1.393
1.393
0.035
Mx4 owed
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
15 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX (918) 295-0265
Description Face Offset Offsets: Azimuth Placement Cy1A CAAAA Weight
or Type Horz Adjustment Front Side
Leg Lateral.
Pert
ft ft ft, ft' K
••K**
(2) X7CQAP-665-VRO
A
From Leg
4.000
0.000
243'
No Ice
9.549
5.458
0.045
(E)
0'
I'
(2) X7CQAP-665-VRO
B
From Leg
4.000
0.000
243'
No Ice
9.549
5.458
0.045
(E)
0'
1'
(2) X7CQAP-665-VRO
C
From Leg
4.000
0.000
243'
No Ice
9.549
5.458
0.045
(E)
0'
1'
(2) E15R05P19
A
From Leg
4.000
0.000
243'
No Ice
0.941
0.608
0.023
(E)
0'
1'
(2) El5R05P19
B
From Leg
4.000
0.000
243'
No Ice
0.941
0.608
0.023
(E)
0'
1'
(2) El5R05P19
C
From Leg
4.000
0.000
243'
No Ice
0.941
0.608
0.023
(E)
0'
1'
RRUS12/RRUS A2
A
From Leg
4.000
0.000
243'
No Ice
3.143
1.835
0.072
(E)
0'
1'
RRUS12/RRUSA2
B
From Leg
4.000
0.000
243'
No Ice
3.143
1.835
0.072
(E)
0'
I
RRUS12/RRUSA2
C
From Leg
4.000
0.000
243'
No Ice
3.143
1.835
0.072
(E)
0'
I
(2) DBC-7CAP
A
From Leg
4.000
0.000
243'
No Ice
0.613
0.116
0.007
(E)
0'
0'
(2) DBC-7CAP
B
From Leg
4.000
0.000
243'
No Ice
0.613
0.116
0.007
(E)
0'
0'
(2) DBC-7CAP
C
From Leg
4.000
0.000
243'
No Ice
0.613
0.116
0.007
(E)
0'
0'
RXXDC-3315-PF-48
B
From Leg
4.000
0.000
243'
No Ice
3.708
2.192
0.032
(E)
0'
1'
6' x 2" Mount Pipe
A
From Leg
4.000
0.000
243'
No Ice
1.425
1.425
0.022
(E)
0'
0'
6' x 2" Mount Pipe
B
From Leg
4.000
0.000
243'
No Ice
1.425
1.425
0.022
(E)
0'
0'
6' x 2" Mount Pipe
C
From Leg
4.000
0.000
243'
No Ice
1.425
1.425
0.022
(E)
0'
0'
Sector Mount ISM 402-3]
C
None
0.000
243'
No Ice
18.910
18.910
0.851
(E-2MP Per Sec)
s•KR-
DC6A8-60-18-8F
A
From Leg
4.000
0.000
143'
No Ice
0.917
0.917
0.019
(E)
0'
3'
(3) SBNHH-ID85B w/
A
From Leg
4.000
0.000
143'
No Ice
8.316
7.004
0.070
MxTower
Job
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
16 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Client
Designed by
Tulsa, OK 74119
Phone. (918) 5874630
Crown Castle
Kiran
FAX (918) 295-0265
Description
Face
Offset
Offsets.
Azimuth
Placement
CAAA
CAAA
Weight
or
Type
Horz
Adjustment
Front
Side
Leg
Lateral
Vert
ft
0
fr
fF
f2
K
ft
R
Mount Pipe
0'
(P)
3'
(3) SBNHH-ID85B w/
C
From Leg
4.000
0.000
143'
No Ice
8.316
7.004
0.070
Mount Pipe
0'
(P)
3'
(2)
B
From Leg
4.000
0.000
143'
No Ice
8.371
6.537
0.069
ET-X-UW-68-14-65-18-IR-A
0'
T w/ Mount Pipe
3'
(P)
80010965K w/ Mount Pipe
B
From Leg
4.000
0.000
143'
No Ice
14.051
7.628
0.125
(P)
0'
3'
RRUS 32
A
From Leg
4.000
0.000
143'
No Ice
2.857
1.777
0.055
(P)
0'
3'
RRUS 32
B
From Leg
4.000
0.000
143'
No Ice
2.857
1.777
0.055
(P)
0'
3'
RRUS 32
C
From Leg
4.000
0.000
143'
No Ice
2.857
1.777
0.055
(P)
0'
3'
RRUS 4449 B5/B12
A
From Leg
4.000
0.000
143'
No Ice
1.969
1.408
0.071
(P)
0'
3,
RRUS 4449 135/1312
B
From Leg
4.000
0.000
143'
No Ice
1.968
1.408
0.071
(P)
0'
3'
RRUS 4449135/1112
C
From Leg
4.000
0.000
143'
No Ice
1.968
1.408
0.071
(P)
0'
3'
RRUS 8843 132B66A
A
From Leg
4.000
0.000
143'
No Ice
1.639
1.353
0.072
(P)
0'
3'
RRUS 8843 B2/B66A
B
From Leg
4.000
0.000
143'
No Ice
1.639
1.353
0.072
(P)
0'
3'
RRUS 8843 B2/1366A
C.
From Leg
4.000
0.000
143'
No Ice
1.639
1.353
0.072
(P)
0'
3'
DC6-48-60-18-8C
B
From Leg
4.000
0.000
143'
No Ice
2.737
2.737
0.026
(P)
0'
3'
DC648-60-18-8C
C
From Leg
4.000
0.000
143'
No Ice
2.737
2.737
0.026
(P)
0'
3'
Sector Mount [SM 502-31
C
None
0.000
143'
No Ice
33.020
33.020
1.673
(E)
•sgss
TTTT65AP-IXR w/ Mount
A
From Leg
4.000
0.000
130'
No Ice
7.218
4.777
0.056
Pipe
0'
(E)
2'
TTTT65AP-1XR w/ Mount
B
From Leg
4.000
0.000
130'
No Ice
7.218
4.777
0.056
Pipe
0'
(E)
2'
TITT65AP-1XR w/ Mount
C
From Leg
4.000
0.000
130'
No Ice
7.218
4.777
0.056
Pipe
0'
(E)
2'
tnxTower
JOb
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
17 of 39
B+T Group
Project
Date
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client -
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX (918) 295-0265
Description
Face
Offset
Offsets.,
Azimuth
Placement
Cyl,,
CAAA
Weight
or
Type
Horz
Adjustment
Front
Side
Leg
Lateral
Vert
1t
It
ft=
fi2
K
S
R
APXVSPPI8-C w/ Mount
A
From Leg
4.000
0.000
130'
No Ice
8.262
6.946
0.083
Pipe
0'
(E)
2'
APXVSPPI8-C w/Mount
B
From Leg
4.000
0.000
130'
No Ice
8.262
6.946
0.083
Pipe
0'
(E)
2'
APXVSPP18-C w/ Mount
C
From Leg
4.000
0.000
130'
No Ice
8.262
6.946
0.083
Pipe
0'
(E)
2-
RRUS 31 B25
A
From Leg
4.000
0.000
130'
No Ice
1.623
1.279
0.056
(E)
0'
0'
RRUS 31 B25
B
From Leg
4.000
0.000
130'
No Ice
1.623
1.279
0.056
(E)
0'
0'
RRUS 31 B25
C
From Leg
4.000
0.000
130'
No Ice
1.623
1.279
0.056
(E)
0'
0'
FZHJ-RRH
A
From Leg
4.000
0.000
130'
No Ice
1262
1.015
0.055
(E)
0'
1'
FZHJ-RRH
B
From Leg
4.000
0.000
130,
No Ice
1.262
1.015
0.055
(E)
0'
I'
FZHJ-RRH
C
From Leg
4.000
0.000
130'
No Ice
1.262
1.015
0.055
(E)
0'
1'
(3) ACU-A20-N
A
From Leg
4.000
0.000
130'
No Ice
0.067
0.117
0.001
(E)
0
0'
(3) ACU-A20-N
B
From Leg
4.000
0.000
130'
No Ice
0.067
0.117
0.001
(E)
0'
0'
(3) ACU-A20-N
C
From Leg
4.000
0.000
130'
No Ice
0.067
0.117
0.001
(E)
0'
0'
RRUS-11800MHZ
A
From Leg
4.000
0.000
130,
No Ice
2.522
1.303
0.054
(E)
0'
3'
RRUS-11800MHZ
B
From Leg
4.000
0.000
130'
No Ice
2.522
1.303
' 0.054
(E)'
0'
3'
RRUS-I1 800MHZ
C
From Leg
4.000
0.000
130'
No Ice
2.522
1.303
0.054
(E)
o'
3'
800MHZ SMR FILTER
A
From Leg
4.000
0.000
130'
No Ice
0.650
0.222
0.009
(E)
0'
3'
800MHZ SMR FILTER
B
From Leg
4.000
0.000
130'
No Ice
0.650
0.222
0.009
(E)
0'
3'
800MHZ SMR FILTER
C
From Leg
4.000
0.000
130'
No Ice
0.650
0.222
0.009
(E)
0'
3'
(2) Tx2" Auterma Mount Pipe
A
From Leg
4.000
0.000
130'
No Ice
1.663
1.663
0.026
(E)
0'
0'
MxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
18 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX..- (918) 295-0265
Description
Face
Offset
Offsets:
Azimuth
Placement
CAAA
CAAA
Weight
or
Type
Horz
Adjustment
Front
Side
Leg
Lateral
Vert
ft
R
f+'
J12
K
ft
R
(2) Tx2" Antenna Mount Pipe
B
From Leg
4.000
0.000
130'
No Ice 1.663
1.663
0.026
(E)
0'
0'
(2) Tx2" Antenna Mount Pipe
C
From Leg
4.000
0.000
130'
No Ice 1.663
1.663
0.026
(E)
0'
0'
Sector Mount [SM 702-31
C
None
0.000
130'
No Ice 37.400
37.400
1.551
Load Combinations
Comb. Description
No.
2
1.2 Dead+1.0 Wind 0 deg -No Ice
3
0.9 Dead+1.0 Wind 0 deg - No Ice
4
1.2 Dead+1.0 Wind 30 deg -No Ice
5
0.9 Dead+1.0 Wind 30 deg -No Ice
6
1.2 Dead+1.0 Wind 60 deg - No Ice
7
0.9 Dead+1.O Wind 60 deg - No Ice
8
1.2 Dea1+1.0 Wind 90 deg - No Ice
9
0.9 Dead+1.0 Wind 90 deg - No Ice
IO
1.2 Dead+1.0 Wind 120 deg -No Ice
11
0.9 Dead+1.0 Wind 120 deg -No Ice
12
1.2 Dead+1.0 Wind 150 deg -No Ice
13
0.9 Dead+1.0 Wind 150 deg - No Ice
14
1.2 Dead+1.0 Wind 180 deg -No Ice
IS
0.9 Dead+1.0 Wind 180 deg -No Ice
16
1.2 Dead+1.0 Wind 210 deg - No Ice
17
0.9 Dead+l.O Wind 210 deg -No Ice
18
1.2 Dead+1.0 Wind 240 deg - No Ice
19
0.9 Dead+1.0 Wind 240 deg - No Ice
20
1.2 Dead+1.0 Wind 270 deg - No Ice
21
0.9 Dead+1.0 Wind 270 deg - No Ice
22
1.2 Dead+1.0 Wind 300 deg -No Ice
23
0.9 Dead+1.0 Wind 300 deg -No Ice
24
1.2 Dead+1.0 Wind 330 deg -No Ice
25
0.9 Dead+1.0 Wind 330 deg -No Ice
26
Dead+Wind 0 deg - Service
27
Dead+Wind 30 deg -Service
28
Dead+Wind 60 deg - Service
29
Dead+Wind 90 deg - Service
30
Dead+Wind 120 deg -Service
31
Dead+Wind 150 deg -Service
32
Dead+Wind ISO deg - Service
33
Dead+Wind 210 deg -Service
34
Dead+Wind 240 deg -Service
35
Dead+Wmd 270 deg -Service
36
Dead+Wind 300 deg -Service
37
Dead+Wind 330 deg -Service
WxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
19 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX (918) 295-0265
Maximum Member Forces
Minor Axis
Section Elevation
Component
Condition
Gov.
Axial
Major Axis
No. ft
Type
Load
Moment
Moment
Comb.
K
kip-t
ktp-
Tl 250 - 240
Leg
Max Tension
7
1.862
-0.691
0.296
Max. Compression
18
-3.633
0.698
-0.300
Max. Mx
8
-3.211
1.302
0.012
Max. My
3
0.587
-0.005
-1.334
Max. Vy
8
-0.987
-0.639
-0.026
Max. Vx
3
1.012
-0.009
0.650
Diagonal
Max Tension
7
2.151
0.000
0.000
Max. Compression
18
-2.270
0.000
0.000
Max. Mx
22
-0.338
0.006
0.000
Max. My
24
-0.003
0.004
0.001
Max. Vy
22
0.006
0.006
0.000
Max. Vx
24
0.000
0.000
0.000
Top Girt
Max Tension
23
0.161
0.000
0.000
Max. Compression
10
-0.206
0.000
0.000
Max. NIX
2
0.060
-0.014
0.000
Max. Vy
2
0.009
0.000
0.000
T2 240 - 220
Leg
Max Tension
7
26.251
-0.130
-0.087
Max. Compression
18
-30.407
0.072
0.082
Max. MX
11
-10.392
0.762
0.002
Max. My
4
-1.075
-0.001
-0.791
Max. Vy
3
0.198
0.754
-0.065
Max. Vx
4
-0.265
-0.001
-0.791
Diagonal
Max Tension
7
4.363
0.000
0.000
Max. Compression
18
-4.620
0.000
0.000
Max. MX
6
3.014
0.020
-0.004
Max. My
18
-4.583
0.003
0.007
Max. Vy
6
0.012
0.020
-0.004
Max. Vx
6
0.002
0.000
0.000
T3 220 - 200
Leg
Max Tension
7
54.723
-0.090
-0.088
Max. Compression
18
-62.513
0.155
0.086
Max. Mx
19
-61.812
0.156
0.086
Max. My
16
-2.918
-0.010
0.226
Max. Vy
19
-0.112
0.153
0.068
Max. Vx
16
-0.163
-0.010
0.226
Diagonal
Max Tension
18
5.624
0.000
0.000 '
Max. Compression
18
-5.850
0.000
0.000
Max. Mx
18
3.667
0.025
0.007
Max. My
18
-5.436
0.006
0.007
Max. Vy
6
0.014
. 0.024
-0.007
Max. Vx
16
-0.002
0.000
0.000
T4 200 - 180
Leg
Max Tension
7
85.264
-0.173
-0.093
Max. Compression
18
-97.541
0.073
0.085
Max. Mx
19
-84.563
0.180
0.093
Max. My
16
-4.842
-0.012
0.331
Max. Vy
19
-0.100
0.180
0.093
Max. Vx
16
0.211
-0.010
0.274
Diagonal
Max Tension
18
7.133
0.000
0.000
Max. Compression
18
-7.380
0.000
0.000
Max. Mx
6
4.238
0.042
-0.009
Max. My
18
-7.302
0.013
0.011
Max. Vy
6
0.020
0.042
-0.009
Max. Vx
18
-0.002
0.000
0.000
T5 180 -160
Leg
Max Tension
7
114.973
0.179
-0.072
Max. Compression
18
-132.221
-0.241
0.066
Max. Mx
18
-132.066
0.479
0.023
tnxTower
ob
J 77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
20 of 39
B+T Group
1717 S. Boulder, Suite 300
Project
Date
14:12:19 01 /23/19
Client
Designed by
Tulsa, OK 74119
Phone. (918) 587-4630
FAX (918) 295-0265
Crown Castle
Kiran
Section Elevation
No. Jt
Component
Type
Condition
Gov.
Load
Comb.
Axial
K
Major Axis
Moment
kip-jl
Minor Axis
Moment
kip- tt
Max. My
16
-5.979
-0.038
0.406
Max. Vy
18
-0.207
0.479
0.023
Max. Vx
16
0.205
-0.038
0.406
Diagonal
Max Tension
18
9.217
0.000
0.000
Max. Compression
18
-9.781
0.000
0.000
Max. Mx
2
7.456
0.058
0.000
Max. My
2
1.263
0.000
-0.002
Max. Vy
2
-0.027
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Horizontal
Max Tension
18
2.649
0.000
0.000
Max. Compression
18
-2.649
0.018
-0.001
Max. Mx
6
1.324
0.019
-0.001
Max. My
2
-0.154
0.016
-0.001
Max. Vy
6
-0.013
0.019
-0.001
Max. Vx
2
0.000
0.016
-0.001
Inner Bracing
Max Tension
1
0.000
0.000
0.000
Max. Compression
24
-0.003
0.000
0.000
Max. Mx
2
-0.003
-0.017
0.000
Max. Vy
2
0.010
0.000
0.000
T6 160 - 140
Leg
Max Tension
7
148.161
0.412
-0.074
Max. Compression
18
-173.775
OA54
0.097
Max. Mx
22
127.062
1.714
0.010
Max. My
24
-8.733
-0.045
-1.858
Max. Vy
22
-1.507
-1.250
0.010
Max. Vx
24
1.245
0.018
0.589
Diagonal
Max Tension
19
11.873
0.000
0.000
Max. Compression
18
-12.553
0.000
0.000
'
Max: Mx
2
7.691
0.073
0.000'
Max. My
2
1.290
0.000
-0.002
Max. Vy
2
-0.031
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Horizontal
Max Tension
18
3.304
0.000
0.000
Max. Compression
18
-3.304
0.030
0.001
Max. Mx
22
-0.466
0.030
0.003
Max. My
10
0.516
0.028
-0.005
Max. Vy
22
0.019
0.030
0.003
Max. Vx
10
-0.001
0.028
-0.005
IrmerBmeing
Max Tension
1
0.000
0.000
0.000
Max. Compression
22
-0.005
0.000
0.000
Max. Mx
2
-0.004
-0.023
0.000
Max. Vy
2
0.012
0.000
0.000
T7 140 - 120
Leg
Max Tension
7
192.784
0.233
-0.078
Max. Compression
18
-227.087
-0.416
0.088
Max. N4x
18
-226.843
.. 0.727
0.002
Max. My
16
-10.205
-0.069
1.297
Max. Vy
22
-1.722
0.170
0.050
Max. Vx
16
1.910
-0.060
0.219
Diagonal
Max Tension
20
16.532
0.000
0.000
Max. Compression
18
-17.189
0.000
0.000
Max. Mx
2
13.287
0.089
0.000
Max. My
2
1.485
0.000
-0.003
Max. Vy
2
-0.035
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Horizontal
Max Tension
18
4.118
0.000
0.000
Max. Compression
18
-4.118
0.042
-0.001
Max. Mx
18
-0.496
0.050
-0.001
Max. My
6
-2.021
0.042
-0.002
Max. Vy
18
-0.026
0.050
-0.001
Max. Vx
6
-0.001
0.042
-0.002
Inner Bracing
Max Tension
1
0.000
0.000
0.000
Max. Compression
12
-0.004
0.000
0.000
WxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
21 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone. (918) 587-4630
Crown Castle
Kiran
FAX: (918) 295-0265
Section Elevation
Component
Condition
Gov.
Axial
Major Axis
Minor Axis
No. jl
Type
Load
Moment
Moment
Comb.
K
kin-ft
kip-jt
Max. Mx
2
-.0.004
-0.037
0.000
Max. Vy
2
0.017
0.000
0.000
T8 120 -100
Leg
Max Tension
7
244.389
0.309
-0.071
Max. Compression
18
-287.505
-0.404
0.121
Max. Mx
18
-287.243
0.988
-0.014
Max. My
16
-16.004
-0.083
1.061
Max. Vy
18
-0.334
0.888
-0.014
Max. Vx
18
-0.346
0.081
1.029
Diagonal
Max Tension
20
18.592
0.000
0.000
Max. Compression
18
-18.950
0.000
0.000
Max. Mx
2
14.627
0.131
0.000
Max. My
2
1.133
0.000
-0.004
Max. Vy
2
-0.047
0.000
0.000
Max. Vx
2
0.002
0.000
0.000
Horizontal
Max Tension
18
4.991
0.000
0.000
Max. Compression
18
4.991
0.053
-0.002
Max. Mx
18
-0.633
0.059
-0.001
Max. My
6
2.499
0.051
-0.002
Mae. Vy
18
-0.029
0.059
-0.001
Max. Vx
6
-0.001
0.051
-0.002
Inner Bracing
Max Tension
1
0.000
0.000
0.000
Max. Compression
18
-0.005
0.000
0.000
Max. Mx
2
-0.005
-0.046
0.000
Max. Vy
2
0.019
0.000
0.000
T9 100 - 80
Leg
Max Tension
7
296.943
0.517
-0.065
Max. Compression
'18
-350.249
-3.076
-0.125
Max. Mx
18
-350249
-3.076
-0.125
Max. My
16
-16.815
-0.083
1.061
Max. Vy
18
1.029
1.730
0.032
Max. Vx
18
0.349
0.081
1.029
Diagonal
Max Tension
21
20.871
0.000
0.000
Max. Compression
20
-21.330
0.000
0.000
Max. Mz
2
16.560
0.253
0.000
Max. My
2
0.711
0.000
-0.008
Max. Vy
2
-0.084
0.000
0.000
Max. Vx
2
-0.003
0.000
0.000
Horizontal
Max Tension
18
6.074
0.000
0.000
Max. Compression
18
-6.074
0.085
-0.002
Max. Mx
18
-0.758
0.094
-0.003
Max. My
18
-0.758
0.094
-0.003
Max. Vy
18
-0.042
0.094
-0.003
Max. Vx
18
0.001
0.094
-0.003
Inner Bracing
Max Tension
1
0.000
0.000
0.000
Max. Compression
6
-0.008
0.000
0.000
Max. Mx
2
-0.008
-0.068
0.000
Max. Vy
2
0.025
0.000
0.000
T10 80 - 60
Leg
Max Tension
7
336.485
2.581
0.118
Max. Compression
18
-397.527
-4.536
0.103
Max. Mx
18
-397.527
-4.536
0.103
'
Max. My
16
-22.708
-0.406
2.078
Max. Vy
18
-1.486
4.028
0.236
Max. Vx
16
-0.771
-0.406
2.078
Diagonal
Max Tension
20
26.664
-0.197
0.101
Max. Compression
18
-27.609
0.000
0.000
Max. Mx
18
25.353
-0.216
0.125
Max. My
18
18.714
-0.205
-0.125
Max. Vy
18
-0.055
-0.216
0.125
Max. Vx
18
0.018
0.000
0.000
Horizontal
Max Tension
18
6.894
0.000
0.000
Max. Compression
18
-6.894
-0.121
0.003
Max. Mx
18
-0.634
-0.136
0.005
WxTower
'°b
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
22 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX..- (918) 295-0265
Section Elevation Component Condition Gov. Axial Major Axis Minor Axis
No. ft Type Load Moment Moment
Max. My
18
-0.634
-0.136
0.005
Max. Vy
18
0.056
-0.136
0.005
Max. Vx
18
-0.002
-0.136
0.005
Redund Horz 1
Max Tension
18
6.896
0.000
0.000
Bmcing
Max. Compression
18
-6.896
0.000
0.000
Max. Mx
2
6.237
0.025
0.000
Max. My.
2
0.141
0.000
-0.001
Max. Vy
2
0.018
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Redund Ding 1
Max Tension
18
4.684
0.000
0.000
Bracing
Max. Compression
18
-4.684
0.000
0.000
Max. Mx
2
1.051
0.036
0.000
Max. My
2
0.413
0.000
-0.001
Max. Vy
2
-0.018
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Redund Hip
Max Tension
19
0.036
0.000
0.000
Bracing
Max. Compression
6
-0.039
0.000
0.000
Max. Mx
2
-0.008
-0.016
0.000
Max. Vy
2
-0.011
0.000
0.000
Inner Bracing
Max Tension
7
0.018
0.000
0.000
Max. Compression
18
-0.030
0.000
0.000
Max. Mx
2
0.004
0.101
0.000
Max. Vy
2
-0.035
0.000
0.000
Tll 60-40 Leg
Max Tension
7
389.519
3.586
-0.117
Max. Compression
18
-461.048
-3.503
0.209
Max. Mx
18
-458.755
4.976
0.240
Max. My
16
-23.799
-0.406
2.078
Max. Vy
18
-1.965
4.976
0.240
Max. Vx
19
-0.595
1.445
1.077
Diagonal
Max Tension
20
27.870
-0.197
0.088
Max. Compression
18
-28.755
0.000
0.000
Max. Mx
18
26.393
-0.213
0.110
Max. My
18
20A32
-0.201
-0.110
Ma,t. Vy
18
-0.055
-0.213
0.110
Max. Vx
18
0.015
0.000
0.000
Horizontal
Max Tension
18
7.996
0.000
0.000
Max. Compression
18
-7.996
-0.157
0.005
Max. Mx
6
-1917
-0.161
0.005
Max. My
6
-3.917
-0.161
0.005
Max. Vy
6
0.061
-0.161
0.005
Max. Vx
6
-0.002
-0.161
0.005
Redund Hom I
Max Tension
18
7.997
0.000
0.000
Bracing
Max. Compression
18
-7.997
0.000
0.000
Max. Mx
2
0.441
0.030
0.000
Max. My
2
-0.512
0.000
-0.001
Max. Vy
2
-0.019
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Redund Diag 1
Max Tension
18
5.247
0.000
0.000
Bracing
Max. Compression
18
-5.247
0.000
0.000
Max. Mx
2
0.897
0.041
0.000
Max. My
2
0.794
0.000
-0.001
Max. Vy
2
-0.020
0.000
0.000
Max. Vx
2
-0.001
0.000
0.000
Redund I -lip 1
Max Tension
19
0.029
0.000
0.000
Bracing
Max. Compression
6
-0.034
0.000
0.000
tnxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
23 of 39
Project
Date
B+T Group
1717S Boulder, Suite 300-
14:12:19 01/23/19
Tulsa, OK 74119
Client
Designed by
Phone., (918)587-4630
Crown Castle
Klran
FAX: (918) 295-0265
Section Elevation
Component
Condition
Gov.
Axial
Major Axis
Minor Axis
No. jf
Type
Load
Moment
Moment
Comb.
K
kip ft
kip Jt
Max. Mx
2
-0.007
-0.019
0.000
Max. Vy
2
0.012
0.000
0.000
Eimer Bracing
Max Tension
7
0.014
0.000
0.000
Max. Compression
18
-0.026
0.000
0.000
Max. Mx
2
0.003
0.120
0.000
Max. Vy
2
0.038
0.000
0.000
T12 40-20
Leg
Max Tension
7
442.381
2.873
-0.209
Max. Compression
18
-524.438
-5.689
0.094
Max. Mx
18
-524.438
-5.689
0.094
Max. My
16
-29.970
-0.536
2.957
Max. Vy
18
1.811
3.084
-0.218
Max. Vx
16
-0.968
-0.536
2.957
Diagonal
Max Tension
20
29.006
-0.249
0.104
Max. Compression
18
-29.733
0.000
0.000
Max. Na
18
27.731
-0.271
0.130
Max. My
18
21.671
-0.259
-0.130
Max. Vy
18
0.073
-0.271
0.130
Max. Vx
18
0.017
0.000
0.000
Horizontal
Max Tension
18
9.095
0.000
0.000
Max. Compression
18
-9.095
-0.168
0.005
Max. Mx
18
-0.927
-0.186
0.006
Max. My
2
-0.874
-0.185
0.006
Max. Vy
i8
0.066
-0.186
0.006
Max. Vx
2
0.002
-0.185
0.006
Redund Horz 1
Max Tension
18
9.097
0.000
0.000
Bracing
Max. Compression
18
-9.097
0.000
0.000
Max. Mx
2
0.706
0.035
0.000
Max. My
2
-0.067
0.000
-0.001
Max. Vy
2
0.021
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Redund Diag l
Max Tension
18
5.798
0.000
0.000
Bracing
Max. Compression
18
-5.798
0.000
0.000
Max. Mx
2
0.960
0.046
0.000
Max. My
2
0.674
0.000
-0.002
Max. Vy
2
-0.021
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Redund Hip 1
Max Tension
19
0.032
0.000
0.000
Bracing
Max. Compression
6
-0.038
0.000
0.000
Max. Mx
2
-0.011
-0.022
0.000
Max. Vy
2
0.013
0.000
0.000
Inner Bracing
Max Tension
7
0.017
0.000
0.000
Max. Compression
18
-0.032
0.000
0.000
Max. Mx
2
0.003
0.176
0.000
Max. Vy
2
-0.052
0.000
0.000
T13 20-0 Leg
Max Tension
7
493.063
4.434
-0.1I1
Max. Compression
18
-587.351
0.000
-0.000
Max. Mx
18
-584.062
-5.689
0.094
Mini. My
16
-31.272
-0.536
2.957
Max. Vy
18
-2.317
5.655
0.226
Max. Vx
16
0.486
-0.536
2.957
Diagonal
Max Tension
20
29.754
-0.249
0.089
Max. Compression
18
-30.387
0.000
0.000
Max. Mx
18
26.643
-0.266
0.112
Max. My
18
27.922
-0.266
0.112
Max. Vy
18
-0.074
-0.266
0.112
Max. Vx
18
-0.015
0.000
0.000
Horizontal
Max Tension
18
10.186
0.000
0.000
Max. Compression
18
-10.186
-0.259
0.008
InxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
24 of 39
B+T Group
Project
Date
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Client
Designed by
Tulsa, OK 74119
Phone: (918) 587-4630
Crown Castle
Kiran
FAX.. (918) 295-0265
Section Elevation Component Condition Gov. Axial MajorAsis Minor Axis
No. ft Type Load Moment Moment
Max. Mx
6
-4.992
-0.269
0.008
Max. My
6
-4.992
-0.269
0.008
Max. Vy
6
0.086
-0.269
0.008
Max. Vx
6
-0.003
-0.269
0.008
Redund Hoa 1
Max Tension
18
10.187
0.000
0.000
Bracing
Max. Compression
18
-10.187
0.000
0.000
Max. Mx
2
0.575
0.040
0.000
Max. My
2
0.013
0.000
-0.001
Max. Vy
2
-0.022
0.000
0.000
'
Max. Vx
2
0.001
0.000
0.000
Redund Diag 1 1
Max Tension
18
6.333
0.000
0.000
Bracing
Max. Compression
18
-6.333
0.000
0.000
Max. Mx
2
0.878
0.052
0.000
Max. My
2
1.031
0.000
-0.002
Max. Vy
2
-0.023
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Redund Hip I
Max Tension
19
0.026
0.000
0.000
Bracing
Max. Compression
6
-0:033
0.000
0.000
Max. Mx
2
-0.010
-0.025
0.000
'Max. Vy
2
0.014
0.000
0.000
Inner Bracing
Max Tension
7
0.012
0.000
0.000
Max. Compression
18
-0.029
0.000
0.000
-
Max. Mx
2
0.000
0.203
0.000
Max. Vy
2
-0.056
0.000
0.000
Maximum Reactions
Location Condition Gov. [vertical Horizontal, X Horizontal, Z
Load K K K
Leg
Max. Vert
18
617.063
65.742
-35.013
Max. H,
18
617.063
65.742
-35.013
Max. H.
7
-517.835
-57.012
30.029
Min. Vert
7
-517.835
-57.012
30.029
Min. H.
7
-517.835
-57.012
30.029
Min. H.
18
617.063
65.742
-35.013
Leg
Max. Vert
10
567.591
-60.088
-33.156
Max. H.
21
-440.939
51.681
21.434
Max. H,
25
-394.177
41.681
28.170
Min. Vert
23
464.501
51.323
28.112
Min. H.
10
567.591
-60.088
-33.156
Min. H,.
10
567.591
-60.088
-33.156
Leg
Max. Vert
2
561.871
-0.106
68.247
Max. H„
20
32.772
8.904
2.654
Max. H,
2
561.871
-0.106
68.247
Min. Vert
15
464.153
0.140
-58.219
Min. H.
9
22.765
-8.869
1.822
Min. H.
15
464.153
0.140
-58.219
Tower Mast Reaction Summary
c
1
WxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
25 of 39
B+T Group
Project
Date
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX' (918) 295-0265
Load
Vertical
Shear,
Shear,
Overturning
Overturning
Torque
Combination
Moment, M.
Moment, M.
K
K
K
kip-jt
kip-jt
kip-jt
Dead Only
82.616
0.000
0.000
28.385
-27.588
0.000
1.2 Dead+l.O Wind O deg -No
99.140
-0.161
-114.691
-13739.261
-6.177
-7.098
Ice
0.9 Dead+l.O Wind O deg -No
74.355
-0.161
-114.691
-13747.776
2.099
-7.098
Ice
1.2 Dead+1.0 Wind 30 deg -No
99.140
55.979
-96.959
-11821.643
-6878.000
105.265
Ice
0.9 Dead+1.0 Wind 30 deg -No
74.355
55.979
-96.959
-11830.158
-6869.723
105.265
Ice
1.2 Dead+1.0 Wind 60 deg -No
99.140
100.168
-57.646
-6987.097
-12247.965
130.411
Ice
0.9 Dead+1.0 Wind 60 deg -No
74.355
100.168
-57.646
-6995.612
-12239.688
130.411
Ice
1.2 Dead+1.0 Wind 90 deg -No
99.140
115.563
0.161
60.990
-14028.859
98.793
Ice
0.9 Dead+1.0 Wind 90 deg -No
74.355
115.563
0.161
52.474
-14020.583
98.793
Ice
1.2 Dead+1.0 Wind 120 deg-
99.140
99.811
57.626
6955.149
-12020.781
68.681
No Ice
0.9 Dead+1.0 Wind 120 deg-
74.355
99.811
57.626
6946.634
-12012.504
69.681
No Ice
1.2 Dead+1.0 Wind 150 deg -
99.140
52.655
90.879
10926.356
-6352.868
71.565
No Ice
0.9 Dead+1.0 Wind 150 deg -
74.355
52:655
90.879
10917.841
-6344.592
71.565
No Ice
1.2 Dead+1.0 Wind 190 deg -
99.140
0.161
104.911
12711.499
-60.033
7.098
No Ice
0.9 Dead+1.0 Wind 180 deg -
74.355
0.161
104.911
12702.984
-51.757
7.098
No Ice
1.2 Dead+1.0 Wind 210 deg -
99.140
-55.979
96.959
11889.766
6811.789
-105.265
No Ice
0.9 Dead+l.O Wind 210 deg-
74.355
-55.979
96.959
11881.251
6820.065
-105.265
No Ice
1.2 Dead+1.0 Wind 240 deg-
99.140
-109.638
62.536
7603.163
13130.818
-130.411
No Ice
0.9 Dead+1.0 Wind 240 deg-
74.355
-108.638
62.536
7594.647
13139.095
-130.411
No Ice
1.2 Dead+l.O Wind 270 deg-
99.140
-115.563
-0.161
7.134
13962.648
-98.793
No Ice
0.9Dead+1.0 Wind 270 deg-
74.355
-115.563
-0.161
-1.382
13970.925
-98.793
No Ice
1.2 Dead+1.O Wind 300 deg -
99.140
-91.341
-52.736
-6339.083
11005.506
-68.681
No Ice
0.9 Dead+1.0 Wind 300 deg-
74.355
-91.341
-52.736
-6347.599
11013.782
-68.681
No Ice
1.2 Dead+1.0 Wind 330 deg -
99.140
-52.655
-90.879
-10858.233
6286.658
-71.565
No Ice
0.9 Dead+1.0 Wind 330 deg -
74.355
-52.655
-90.879
-10866.749
6294.934
-71.565
No Ice
Dead+Wind 0 deg - Service
82.616
-0.025
-17.632
-2089.090
-23.448
-1.091
Dead+Wind 30 deg - Service
82.616
8.606
-14.906
-1794.281
-1079.904
16.183
Dead+Wind 60 deg - Service
92.616
15.400
-9.862
-1051.030
-1905.469
20.049
Dead+Wind 90 deg -Service
82.616
17.766
0.025
32.524
-2179.259
15.188
Dead+Wind 120 deg -Service
82.616
15.345
8.859
1092.415
-1870.542
10.559
Dead+Wind 150 deg - Service
82.616
8.095
13.971
1702.938
-999.172
11.002
Dead+Wind ISO deg - Service
82.616
0.025
16.129
1977.381
-31.728
1.091
Dead+Wind 210 deg - Service
82.616
-8.606
14.906
1851.050
1024.729
-16.183
Dead+Wind 240 deg -Service
82.616
-16.702
9.614
1192.039
1996.200
-20.049
Dead+Wind 270 deg -Service
82.616
-17.766
-0.025
24.245
2124.083
-15.188
Dead+Wind 300 deg -Service
82.616
-14.042
-8.107
-951.406
1669,460
-10.559
tnxTower
ob
J 77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
26 of 39
B+T Group
1717 S. Boulder, Suite 300
Project
Date
14:12:19 Ol /23/19
Client
Designed by
Tulsa, OK 74119
Phone: (918) 587-4630
FAX.- (918) 295-0265
Crown Castle
Kiran
Load Vertical Shear, Shear: Overturning Overturning Torque
Combination Moment, M. Moment, M
K K K kipft kipft kio-ft
Dead+Wind 330 deg - Service 82.616 -8.095-13.971-1646.169 943.996 -11.002
Solution Summary
Sum of Applied Forces
Sum of Reactions
Load
PX
PY
PZ
PX
PY
PZ
%Error
Comb.
K
K
K
K
K
K
1
0.000
-82.616
0.000
-0.000
82.616
-0.000
0.000%
2
-0.161
-99.140
-114.691
0.161
99.140
114.691
0.000%
3
-0.161
-74.355
-114.691
0.161
74.355
114.691
0.000%
4
55.979
-99.140
-96.959
-55.979
99.140
96.959
0.000%
5
55.979
-74.355
-96.959
-55.979
74355
96.959
0.000%
6
100.168
-99.140
-57.646
-100.168
99.140
57.646
0.000%
7
100.168
-74.355
-57.646
-100.168
74.355
57.646
0.000%
8
115.563
-99.140
0.161
-115.563
99.140
-0.161
0.000%
9
115.563
-74.355
0.161
-115.563
74.355
-0.161
0.000%
10
99.811
-99.140
57.626
-99.911
99.140
-57.626
0.000%
11
99.811
-74.355
57.626
-99.811
74.355
-57.626
0.000%
12
52.655
-99.140
90.879
-52.655
99.140
-90.979
0.000%
13
52.655
-74.355
90.879
-52.655
74.355
-90.879
0.000%
14
0.161
-99.140
104.911
-0.161
99.140
-104.911
0.000%
15
0.161
-74.355
104.911
-0.161
74.355
-104.911
0.000%
16
-55.979
-99.140
96.959
55.979
99.140
-96.959
0.000%
17
-55.979
-74.355
96.959
55.979
74.355
-96.959
0.000%
18
-108.638
-99.140
62.536
108.638
99.140
-62.536
0.000%
19
-108.638
-74.355
62.536
108.638
74.355
-62.536
0.000%
20
-115.563
-99.140
-0.161
115.563
99.140
0.161
0.000%
21
-115.563
-74.355
-0.161
115.563
74.355
0.161
0.000%
22
-91.341
-99.140
-52.736
91.341
99.140
52.736
0.000%
23
-91.341
-74.355
-52.736
91.341
74.355
52.736
0.000%
24
-52.655
-99.140
-90.879
52.655
99.140
90.879
0.000%
25
-52.655
-74.355
-90.879
52.655
74.355
90.879
0.000%
26
-0.025
-82.616
-17.632
0.025
82.616
17.632
0.000%
27
8.606
-82.616
-14.906
-8.606
82.616
14.906
0.000%
28
15.400
-82.616
-8.862
-15.400
82.616
8.862
0.000%
29
17.766
-82.616
0.025
-17.766
82.616
-0.025
0.000%
30
15.345
-82.616
8.859
-15.345
82.616
-8.859
0.000%
31
8.095
-82.616
13.971
-8.095
82.616
-13.971
0.000%
32
0.025
-82.616
16.129
-0.025
82.616
-16.129
0.000%
33
-8.606
-82.616
14.906
8.606
82.616
-14.906
0.000%
34
-16.702
-82.616
9.614
16.702
92.616
-9.614
0.000%
35
-17.766
-82.616
-0.025
17.766
82.616
0.025
0.000%
36
-14.042
-82.616
-8.107
14.042
82.616
8.107
0.000%
37
-8.095
-82.616
-13.971
8.095
82.616
13.971
0.000%
Maximum Tower Deflections - Service Wind
Section
Elevation
Hon.
Gov.
Tilt
Twist
No.
Deflection
Load
J
in
Comb.
T1
250 -240
3.565
34
0.115
0.035
T2
240 -220
3.323
34
0.114
0.034
T3
220 - 200
2.840
34
0.109
0.031
tnxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
27 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01123/19
Tulsa, OK 74119
Client
Designed by
Phone. (918)587-4630
Crown Castle
Kiran
FAX.- (918) 295-0265
Section
No.
Elevation
ft
Horz.
Deflection
in
Gov.
Load
Comb.
Tilt
Twist
T4
200 -180
2.381
34
0.102
0.027
T5
180 - 160
1.953
34
0.094
0.022
T6
160 - 140
1.570
34
0.083
0.019
T7
140 -120
1.229
34
0.072
0.016
T8
120 - 100
0.923
34
0.062
0.013
T9
100- 80
0.662
34
0.051
0.010
TIO
80-60
0.452
34
0.040
0.008
T11
60-40
0.271
34
0.030
0.006
T12
40-20
0.137
34
0.020
0.003
T13
20-0
0.042
34
0.010
0.002
Critical Deflections and Radius of Curvature - Service Wind
Elevation Appurtenance Gov. Deflection Tilt Twist Radius of
Load Curvature
ft Comb. in of1
243'
(2)X7CQAP-665-VRO
34
3.396
0.115
0.035
906124
234'
4'Dipole
34
3.177
0.114
0.034
866558
215'
4'Dipole
34
2.723
0.108
0.030
156720
191,
4'Dipole
34
2.183
0.099
0.024
128641
177'
34
1.892
0.092
0.021
98182
143'
.4'Dipole
DC6-48-60-18-8F
34
1.278
0.074
0.016
142673
130'
TTTT65AP-IXR w/Mount Pipe
34
1.072
0.067
0.014
130232
125'
Side Lighting
34
0.996
0.064
0.013
122065
Maximum Tower Deflections - Design Wind
Section
Elevation
Hon.
Gov.
Tilt
Twist
No.
Deflection
Load
ft
in
Comb.
°
Tl
250-240
23.320
19
0.753
0.226
T2
240 - 220
21.733
19
0.750
0.224
T3
220-200
18.569
19
0.718
0.203
T4
200 - 180
15.560
19
0.670
0.172
T5
180- 160
12.757
19
0.613
0.142
T6
160 - 140
10.250
19
0.542
0.123
T7
140-120
8.022
19
OA71
0.103
T8
120-100
6.026
19
OA02
0.081
T9
100 - 80
4.319
19
0.332
0.064
T10
80-60
2.950
19
0.262
0.053
T11
60-40
1.766
19
0.195
0.037
T12
40 -20
0.891
19
0.132
0.022
T13
20 - 0
0.275
18
0.063
0.011
Critical Deflections and Radius of Curvature - Design Wind
tnxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
28 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone., (918)587-4630
Crown Castle
Kiran
FAX: (918) 295-0265
Elevation
ft
Appurtenance
. Gov.
Load
Comb.
Deflection
in
Tilt
Twist
0
Radius of
Curvature
ft
249'6"
Flash Beacon Lighting
19
23.241
0.753
0.226
196871
243'
(2) X7CQAP-665-VRO
19
22.210
0.752
0.225
144530
234'
4'Dipole
19
20.778
0.744
0.220
159737
215'
4'Dipole
19
17.799
0.706
0.196
24702
191,
4'Dipole
19
14.268
0.646
0.158
19547
177'
4'Dipole
19
12.361
0.603
0.139
14954
143'
DC648-60-18-8F
19
8.341
0.482
0.106
21649
130'
TTTT65AP-1XR w/Mount Pipe
19
6.994
OA37
0.092
19821
125'
Side Liahtine
19
6.502
OA20
0.087
18604
Bolt Design Data
Criteria
Section
Elevation
Component
Bolt
BoltSize
Number
Maximum
Allowable
Ratio
Allowable
No.
Type
Grade
Of
Load
Load
Load
Ratio
f}
in
Bolts
per Bolt
per Bolt
Allowable
K
K
TI
250
Leg
A325N
0.625
4
0.466
20.340
'0.023
1.05
Bolt Tension
Diagonal
A325N
0.625
2
1.075
6.785
1.05
Member Block
0158
Shear
Top Girt
A325N
0.625
1
0.161
7.875
1.05
Member Block
0.020
Shear
T2
240
Leg
A325N
0.625
6
4.375
20.340
1.05
Bolt Tension
0.215
Diagonal
A325N
0.625
2
2.182
7.805
1.05
Member Block
0.280
Shear
T3
220
Leg
A325N
0.875
6
9.121
41.556
1.05
Bolt Tension
0.219
t✓
Diagonal
A325N
0.625
2
2.812
7.805
1.05
Member Block
0.360
Shear
T4
200
Leg
A325N
1.000
6
14.211
54.517
1.05
Bolt Tension
0.261
//
Diagonal
A325N
0.625
2
3.567
8.314
/
"05
Member Block
0.429
Shear
T5
180
Leg
A325N
1.000
6
19.138
54.517
1.05
Bolt Tension
0.351
Diagonal
A325N
0.625
2
4.609
15.609
1.05
Member Block
0.295
Shear
Horizontal
A325N
0.625
1
2.649
7.875
1.05
Member Block
0.336
Shear
T6
160
Leg
A325N
1.000
6
24.663
54.517
1.05
Bolt Tension
0.452
l/
Diagonal
A325N
0.625
2
5.936
15.609
1.05
Member Block
0.380
Shear
Horizontal
A325N
0.625
l
3.304
9.914
1.05
Member Block
0.333
Shear
T7
140
Leg
A325N
1.125
6
32.034
68.695
1.05
Bolt Tension
0.466
Diagonal
A325N
0.625
2
8.266
15.609
1.05
Member Block
0.530
Shear
Horizontal
A325N
0.625
1
4.118
10.934
"05
Member Block
0.377
�/
Shear
T8
120
Leg
A325N
1.250
6
40.691
87.220
"05
Bolt Tension
0.467
l/
Diagonal
A325N
0.625
2
9.296
16.629
1.05
Member Block
0.559
Shear
Horizontal
A325N
0.625
1
4.991
10.934
1.05
Member Block
0.457
Shear
T9
100
Leg
A325N
1.250
6
49.436
87.220
1.05
Bolt Tension
0.567
tnxTower
d°b
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
29 of 39
B+T Group
Project
Date
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX (918) 295-0265
Section
Elevation
Component
Bolt
Bolt Size
Number
Maximum
Allowable
Ratio
Allowable
Criteria
No.
Type
Grade
Of
Load
Load
Load
Ratio
ft
in
Bolts
per Bolt
per Bolt
Allowable
K
K
Diagonal
A325X
0.625
2
10.436
25.658
1.05
Member Block
0.407
t✓
Shear
Horizontal
A325N
0.625
1
6.074
13.806
1.05
Bolt Shear
0.440
�/
T10
80
Leg
A325N
1.375
6
55.916
103.939
1.05
Bolt Tension
0538
i/
Diagonal
A325N
0.625
2
13.332
16.629
1.05
Member Block
0802
1/
Shear
Horizontal
A325N
0.625
1
6.894
19.828
1.05
Member Block
0348
i/
Shear
Tll
60
Leg
A325N
1.500
6
64.786
126.472
LOS
Bolt Tension
0.512
Diagonal
A325N
0.625
2
13.935
16.629
1.05
Member Block
0838
Shear
Horizontal
A325N
0.625
1
7.996
19.828
1.05
Member Block
0.403
Shear
T12
40
Leg
A325N
1.500
6
73.514
126A72
1.05
Bolt Tension
0581
i/
Diagonal
A325N
0.625
2
14.503
22.172
V
1.05
Member Block
0.654
Shear
Horizontal
A325N
0.625
1
9.095
19.828
V
1.05
Member Block
0459
Shear
T13
20
Diagonal
A325N
0.625
2
14.877
22.172
V
"05
Member Block
0.671
Shear
Horizontal
A325N
0.625
1
10.186
21.867
V
1.05
Member Block
0.466
Shear
Compression Checks
Leg Design Data (Compression)
Section Elevation Size L L. KUr A P. rSp" Ratio
No. P.
jt ft ft in' K K Op"
T2
240-220
21/2
73
220 - 200
3
T4
200 - 180
3 114
T5
180 - 160
3 114
T6
160 - 140
3 1/2
77
140 - 120
3 3/4
T8
120 - 100
4
T9
100 - 80
4 1/4
10,
5'
120.0
3.142
-3.633
49.286
0.074 '
K=1.00
P/
20'13/32
6'8-1/8"
128.2
4.909
-30.407
67.460
0.4511
"
K=1.00
v
20'13/32
6'8-1/8"
106.8
7.069
-62.513
138.053
0.453 '
"
K=1.00
✓
20'13/32
6'8-1/8"
98.6
8.296
-97.541
183.313
0.532 '
"
K=1.00
(/
20'13/32
5'3/32"
74.0
8.296
-132.221
250.223
0.5281
"
K=1.00
✓
20'13/32
5'3/32"
68.7
9.621
-173.775
306.641
0.567 '
I.
K=1.00
P/
20'13/32
5'3/32"
64.1
11.045
-227.087
368.015
0.617'
It
K=1.00
1/
2013/32
5'3/32"
60.1
12.566
-287.506
434.236
0.662'
"
K=1.00
101
20tl3/32
5'3/32"
56.6
14.186
-350.249
505.220
0.6931
tnxxTower
ob
J 77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
30 of 39
B+T Group
Project
Date
1717 S. Boulder, Suite 300
14:12:19 Ol /23/19
Client
Designed by
Tulsa, OK 74119
Phone: (918) 587-4630
Crown Castle
Kiran
FAX (918) 295-0265
Section
Elevation
Size
L
L.
K11r
A
P.
�P,
Ratio
No.
P"
ft
ft
ft
in2
K
K
gyp"
"
K=1.00
TIO
80-60
41/2
20'13/32
5'3/32"
53A
15.904
-397.527
580.902
0.684'
"
K=1.00
T11
60-40
43/4
20'13/32
5'3/32"
50.6
17.721
-461.048
661.231
0.697'
"
K=1.00
T12
40-20
43/4
20'13132
5'3/32"
50.6
17.721
-524.438
661.231
0.793'
"
K=1.00
1,/
T13
20-0
5
20'13/32
5'3/32"
48.1
19.635
-587.351
746.168
0.787'
"
K=1.00
`/
1 P, l �P" controls
Diagonal. Des i n Data . (Compression)
Section Elevation Size L L" K11r A P. ✓aP, Ratio
No. P.
ft it ft In' K K 16p_
Tl
250-240
L2x2x3/16
7'9-23/3
3'6-7/8"
111.6
0.715
-2.270
15.658
0.145'
2"
K=1.03
v
12
240-220
L21/2x21/2x3/16
10'1-15/
4'11-9/3
119.8
0.902
-4.620
17.814
0.259'
16"
2"
K=1.00
T3
220-200
L21/2x212x3/16
11'8-15/
5'8-3/8"
133.9
0.902
-5.850
14.405
0.406'
16"
K=0.97
T4
200 - 180
L3x3x3/16
13'5-1/4'
66-3/8"
128.8
1.090
-7.380
18.804
0.392'
'
K=0.98
I
v
T5
180 - 160
2L2 12x2 1/2x3/l6x3/8
87-1/4"
T11-7/8'
126.4
1.800
-9.781
31.362
0.312'
'
K=1.00
2L'a'> 45.287 in - 86
T6
160-140
2L212x212x3/16x3/8
9'5-7/32'
8'9-25/3
139.5
1.800
-12.554
25.901
0.485'
'
2"
K=1.00
t/
2L'a' > 48.196 in - 125
T7
140-120
2L212x21/20/160/8
10'3-9/1
9'8-1/32'
153.0
1.800
-17.189
21.613
0.795'
6"
K=1.00
2L'a' > 51.206 in - 164
T8
120 - 100
2L3x3x3/16x3/8
1 V2-3/1
10'6-9/1
140.3
2.180
-18.950
30.645
0.618'
6"
6"
K-1.00
2L'a' > 57.705 in - 203
19
100-80
2L3x3x5/16x3/8
12'1"
11'5-15/
153.0
3.550
-21.330
43.016
0.496'
16"
K=1.00
2L'a'> 61.049 in - 242
T10
80-60
2L3x3x3/16x3/8
15'7-15/
15'4-9/1
102.3
2.180
-27.609
49.905
0.553 '
32"
6"
K=0.50
2L'a'> 44.623 in - 281
T11
60 -40
2L3x3x3/16x3/8
16'4-27/
16'1-27/
107.4
2.180
-28.755
47.474
0.606'
32"
32"
K4.50
t/
2L'a' > 46.853 in - 332
T12
40-20
2L3x3xl/4x3/8
17'2-15/
16'11-9/
112.9
2.880
-29.733
60.916
0.488'
32"
16"
K=0.50
2L'a'>49.290 in-383
T13
20-0
2L3x3xl/4x3/8
18'3/8"
17'9-3/8'
118.4
2.880
-30.387
56.834
0.535'
K=0.50
tnxTower
Jeb
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
31 of 39
B+T Group
Project
Date
1717S. Boulder, Suite 300
14:12:19 01/23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAR: (918) 295-0265
Section Elevation Size L L„ KUr A P. Ratio
No. P.
ft f1 ft inz K K AP_
1 P„ / �P„ controls
2L'a' > 51.647 in - 434
Horizontal Design Data (Compression)
Section
Elevation
Size
L
L„
KUr
A
P.
r P"
Ratio
No.
P.
ft
fJ
f1
in,
K
K
�P"
T5
180-160
L2x2x3/16
13'6'
65-5/8"
197.0
0.715
-2.649
5.272
0.502'
K=1.00
`/
T6
160-140
L21/2x212x3/16
15'6"
7'5-1/2"
180.8
0.902
-3.304
7.897
0.418'
K=1.00
11/
T7
140- 120
L3x3x3/16
17'6"
8'5-3/8"
170.1
1.090
-4.118
10.783
0.3821
K=1.00
T8
120-100
L3x3x3/16
19'6"
9'5-1/4"
190.0
1.090
-4.991
8.641
0.578'
K=1.00
v
T9
100 - 90
L3x3xl/4
21'6"
10'5-1/8'
211.4
1.440
-6.074
9.226
0.658'
K=1.00
T10
80-60
2L212x212x3/16x3/8
23'
111-3/4'
179.0
1.800
-6.894
15.874
0.434'
'
K=1.00
6/
2L'a'> 64.778 in - 280
Tit
60-40
2L2.. 12x21/2x3/16x3/8
25,
12'3-5/8'
194.6 1.800
-7.996
13.451
0.594'
'
K=1.00
2L'a'> 70.444 in-331
T12
40-20
2L21/2x21/20/160/8
27'
13'3-5/8'
210.5 1.900
-9.095
11.524
0.789'
'
K=1.00
2L'a'> 76.171 in-382
T13
20-0
2L3x3x3/16x3/8
29'
141-1/2'
190.1 2.180
-10.186
16.969
0.600'
'
K=1.00
2L'a'> 81.641 in-433
1 P" / ✓aP„ controls
Top Girt Design Data (Compression)
Section Elevation
Size L
L. KUr
A
P.
�P„
Ratio
No.
P.
ft
f1
ft
in'
K
K
4P
Tl 250-240
L2x2x3/l6 6'
A-12" 168.8
0.715
-0.206
7.184
0.029'
K=1.00
1/
' P„ / �P„ Controls
MxTower
J 77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
32 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Client
Designed by
Tulsa, OK 74119
Phone: (918) 587-4630
Crown Castle
Kiran
FAX: (918) 295-0265
Redundant Horizontal 1 Design Data (Compression)
Section Elevation Size L L" K11r A P. r P" Ratio
No. P.
R fr fr in? K K AP_
TIO
80-60
2L2x2x3/16x3/8
5'9"
56-3/4"
108.8
1.430
-6.896
31.854
0.216'
K=1.00
-
2L'a'> 31.969 in - 282
Tll
60-40
2L2x2x3/16x3/8
6'3"
6'5/8"
118.4
1.430
-7.997
28.340
0.282'
K=1.00
2L'a' > 34.782 in - 333
T12
40-20
2L2x2x3/16x3/8
69"
66-5/8"
128.2
1.430
-9.097
24.504
0.371'
K=1.00
t/
2L'a' > 37.656 in- 384
T13
20-0
2L2x2x3/16x3/8
73"
7-1/2"
137.8
1.430
-10.187
21.265
0.479'
K=1.00
2L'a'> 40.470 in - 435
1 P" /V. controls
Redundant Diagonal
1 Design Data'
Com
ression
Ratio
Section
Elevation
Size
L
L.
K11r
A
P.
�Pn
No.
P.
ft
ft
Jt
in
K
K
V.
T10
80-60
2L2x2x3/16x3/8
79-3/4"
7'6-11/1
147.9
1.430
-4.684
18.494
0.253'
6"
K=1.00
�f
2L'a' > 43.438 in - 309
Tll
60-40
2L2x2x3/16x3/8
8'2-7/16'
Tl1-511
155.4
1A30
-5.247
16.761
0.313'
'
6"
K=1.00
2L'a'> 45.657 in - 360
T12
40-20
2L2x2x3/16x3/8
8'7-1/4"
8'4-1/4"
163.4
1.430
-5.798
15.174
0.382'
K=1.00
2L'a'>48.011 in-411
T13
20-0
2L2x2x3/16x3/8
93/16"
8'9-3/32'
171.4
1.430
-6.333
13.815
0.458'
'
K=1.00
2L'a'> 50.340 in-462
1 P" / �P" ccxntrOIS
Redundant Hi 1 Design Data (Compression)
Section Elevation Size L L. K11r A P. �P" Ratio
No. P.
fr it fr int K K AP_
T10 80-60 L21/2x21/2x3/16
519"
519"
139.4
0.902
-0.039
13.287
0.003'
K=1.00
`/
Tll 60-40 L212x21/2x3/16
6'3"
6'3"
151.5
0.902
-0.034
11.246
0.003'
K=1.00
T12 40-20 L21/2x21/2x3/16
6'9"
6'9"
163.6
0.902
-0.038
9.642
0.004'
xTvwer
M
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
33 of 39
B+T Group
Project
Date
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone. (918) 5874630
Crown Castle
Kiran
FAX (918) 295-0265
Section Elevation Size L L. K11r A P. op„ Ratio
No. P.
i ft ft in, K K 6P.
T13 20-0 L21/2x21/20/16 73" 73" 175.8. 0.902 -0.033 8.357 0.004
K=1.00 `/
1 P. / �P" controls
Inner Bracing Design Data (Compression)
Section
Elevation
Size
L
L.
KUr
A
P.
gyp„
Ratio
No.
P.
ft
f1
ft
in'
K
K
6P"
T5
180 - 160
L2x2x3/16
6'9"
6'9"
205.6
0.715
-0.003
4.842
0.001'
K=1.00
T6
160 - 140
L2x2x3/l6
79"
7'9"
236.0
0.715
-0.005
3.673
0.001'
K=L00
v
77
140 - 120
L2 12x2 1/2z3/16
819"
8.9"
212.1
0.902
-0.004
5.738
0.001'
K=L00
T8
120 - 100
L2 12x2 1/2x3/16
919"
9.9"
236.4
0.902
-0.005
4.621
0.001'
K=1.00
1,/
T9
100-80
L3x3x3/16
10,9"
10,9"
216.4
1.090
-0.008
6.659
0.001 �
K=L00
P/
Tl0
80-60
2L2x2x3/16x3/8
11-6"
11'6"
225.0
1.430
-0.030
8.045
0.004'
K=I.00
1,/
2L'a' > 66.092 in - 306
T11 60-40
2L2x2x3/16x3/8
176"
12'6"
244.6 1.430
-0.026
6.815 0.004'
K=1.00
2L'a' > 71.840 in - 357.
T12 40-20
2L21/2x2 I/W/160/8
13'6"
13'6"
213.6 1.800
-0.032
11.192 0.003'
K=1.00
2L'a' > 77.304 in - 408
T13 20-0
2L21/2x2120/160/8
14'6"
14'6"
229.4 1.800
-0.029
9.713 0.003'
K=1.00
2L'a' > 83.030 in - 459
'P. /V COntrOIS
Tension Checks
Leg Design Data Tension
Section
Elevation
Size L
L.
KUr A
P.
Ratio
No.
P.
f1
ft
ft
in'
K
K
' 6p
Tl
250-240
2 10,
5'
120.0 3.142
1.862
141.372
0.013'
V
NxTow&
ob
J 77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
34 of 39
B+T Group
Project
Date
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Client
Designed by
Tulsa, OK 74119
Phone: (918)5874630
Crown Castle
Kiran
FAX (918) 295-0265
Section
No.
Elevation
ft
Size
L
ft
L"
fl
KUr
A
in'
P.
K
�P"
K
Ratio
P.
�P"
T2
240-220
2112
20'13/32
08-1/8"
128.2
4.909
26.251
220.993
0.119,
T3
220-200
3
20'13/32
68-1/8"
106.8
7.069
54:723
318.086
0.172'
T4
200-180
31/4
20'13/32
68-1/8"
98.6
8.296
85.264
373.310
0.228'
T5
180 - 160
3 1/4
20'13/32
5'3/32"
74.0
8.296
114.973
373.310
0.308'
T6
160 - 140
3 1/2
20'13/32
5'3/32"
68.7
9.621
148.161
432.951
0.342'
T7
140 - 120
3 3/4
20'13/32
51/32"
64.1
11.045'
192A24
497.010
0.387'
T8
120-100
4
20'13/32
5-3/32"
60.1
12.566
244.389
565.497
0.432'
T9
100-80
4114
20'13/32
5'3/32"
56.6
14.186
296.943
638.381
0.465'
T10
80-60
41/2
20'13/32
5'3/32"
53.4
15.904
336.485
715.694,
0.470'
T11
60-40
43/4
20'13/32
5'3/32"
50.6
17.721
389.519
797.425
0.488'
T12
40-20
43/4
20'13/32
53/32"
50.6
17.721
442.381
797.425
0.555'
T13
20 -0
5
20'13/32
5'3/32"
48.1
19.635
493.063
883.573
0.558'
' P" / V. controls
Diagonal
Design
Data
Tension
Ratio
Section
Elevation
Size
L
L"
K11r
A
P.
�P"
No.
P.
ft
ft
ft
in,
K
K
kp"
Tl
250-240
L2x2x3/16
7'9-23/3
3'6-7/8"
73.8
0.431
2.151
18.739
0.115'
2"
72
240-220
L2 1/2x2 1/2x3/16
10'1-15/
4111-9/3
79.6
0.571
4.363
24.840
0.176'
16"
2"
v
T3
220 -200
L2 1/2x2 1/2x3/16
11'8-15/
5'8-3/8"
91.4
0.571
5.624
24.840
0.226 '
16"
T4
200-180
L3x3x3/16
13'5-1/4'
6'6-3/8"
86.3
0.712
7.133
30.973
0.230'
T5
180-160
2L21/2x212x3/160/8
8'2-7/16'
7'7-1/16'
123.9
1.139
9.217
49.549
0.186'
1
-♦
21,'a'> 43.448 in - 97
T6
160-140
2L21/2x2120/160/8
9'5-7/32'
8'9-25/3
142.9
'
2"
2L'a'>48.196 in- 126
T7
140 - 120
2L2 12x2 1/20/160/8
9'10-11/
92-27/3
149.4
32"
2"
2L'a'> 49.677 in- 175
Ts
i20-100
2L300/160/8
10'8-27/
101-7/3
134.8
1.139 11.873
49.549
0.240 '
1.139 16.532
49.549
0.334'
1.424 18.592
61.947
0.300'
a�
taxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
35'of 39
Project
Date
B+T Group
1717 S..Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX.- (918) 295-0265
Section Elevation Size L L. KI/r A P. r P„ Ratio
No. P.
ft , ft Ji int K K d,n
2L'a' > 56.142 in - 214
T9
100-80
2L3x3x5/16x3/8
12'1"
11'5-15/
154.7
2.311
20.871
100.526
0.208'
16"
✓
2L'a' > 61.049 in - 243
T10
80 -60
2L3x3x3/16x3/8
14'10-7/
147-1/2'
127.2
1.424
26.664
61.947
0.430'
16"
2L'a' > 42.469 in - 307
Tll
60-40
2L3x3x3/16x3/8
15'7-15/
154-15/
133.7
1.424
27.871
61.947
0.450'
32"
32"
2L'a' > 44.623 in - 358
T12
40 -20
2L3x3xl/4x3/8
16'4-27/
16'1-15/
139.5
1.879
29.006
81.726
0.355 '
32"
16"
✓
2L'a' > 46.989 in - 409
T13
20-0
2L3x3xl/4x3/8
172-15/
16'11-15
146.4
1.879
29.753
81.726
0.364'
32"
/32"
2L'a' > 49.290 in - 460
1 P„ l �P controls
Hofizontal Design Da'ta Tension
Section Elevation Size L L„ Ki/r A P„ �P" Ratio
No. P.
ft Jt Jt in' K K �P"
T5
190- 160
L2x2x3/16
13'6"
65-5/8"
128.6
0.431
2.649
18.739
0.141'
T6
160-140
L212x212x3/16
15'6"
7'5-12"
117.3
0.571
3.304
24.840
0.133'
T7
I40-120
L3x3x3/16
17'6"
8'5-3/8"
109.8
0.712
4.118
30.973
0.133'
T8
120 - 100
L3x3x3/16
19'6"
9'5-1/4"
122.5
0.712
4.991
30.973
0.161 '
T9
100-80
L3x3x1/4
21'6"
10'5-1/8'
136.4
0.939
6.074
40.863
0.149'
1
101
TIO
80-60
2L21/2x21/20/160/8
23'
11'3-3/4'
174.5
1.139
6.894
49.549
0.139'
2L'a' > 64.778 in - 290
T11
60-40
2L212x21/20/160/8
25'
12'3-5/8'
189.7
1.139
7.996
49.549
0.161'
2L'a' > 70.444 in - 331
T12
40-20
2L21/2x2120/160/8
27'
13'3-5/8'
205.2
1.139
9.095
49.549
0.184'
21,'a' > 76.171 in - 397
T13
20-0
21,300/160/8
29'
14'3-12'
182.6
1.424
10.186
61.947
0.164'
2L'a' > 81.641 in - 448
1 P„ / ✓ . controls
MxTower
ob
J 77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
36 of 39
B+T Group
Project
Date
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Client
Designed by
Tulsa, OK 74119
Phone: (918)587-4630
Crown Castle
Kiran
FAX (918) 295-0265
Top Girt'Desi
n Data
Tension
Ratio
Section Elevation
Size L L"
KUr
A P„
r P"
No.
P.
ft
p ft
in' K
K
�Pn
Tl 250 -240
L2x2x3/16 6' 5'6-1/2"
113.5
0.431 0.161
18.739
0.009,
I,
1 P" / �P" controls
Redundant Horizontal 1
Design
Data Tension
- Ratio
Section
Elevation
Size
L
L"
KUr
A
P.
�P"
No.
P.
ft
ft
ft
in'
K
K
V.
T10
80 -60
2L2x2x3/16x3/8
519"
5'6-34'
108.2
1.430
6.896
46.332
0.149 '
2L'a'> 31.969 in - 300
'
T11
60-40
2L2x2x3/16x3/8
63"
6'5/8"
117.7
1.430
7.997
46.332
0.173'
2L'a' > 34.782 in - 351
T12
40-20
2L2x2x3/16x3/8
6"
66-5/8"
127.4
1.430'
9.097
46.332
0.196'
2L'a' > 37.656 in - 384
T13
20-0
2L2x2x3/16x3/8
73"
7'1/2"
137.0
1.430
10.187
46.332
0.2201101
2L'a' > 40.470 in - 453
i P" / �P" controls
Redundant Diagonal 1
Design
Data Tension
Ratio
Section
Elevation
Size
L
L.
KUr
A
P.
rpP"
No.
P.
ft
Jt
ft
in,
K
K
�P"
TIO
80 -60
2L2x2x3/16x3/8
79-3/4"
T6-11/1
147.0
1.430
4.684
46.332
0.101' ,
6"
t/
2L'a'> 43.438 in - 325
T11
60-40
2L2x2x3/16x3/8
8'2-7/16'
T11-5/1
154.5
1.430
5.247
46.332
0.113'
1
6"
✓
2L'a'> 45.657 in - 376
T12
40-20
2L2x2x3/l6x3/8
87-1/4"
8'4-1/4"
162.5
1.430
5.798
46.332
0.125'
2L'a' > 48.011 in - 411
T13
20 - 0
2L2x2x3/16x3/8
9'3/16"
8'9-3/32'
170A
IA30
6.333
46.332
0.137'
2L'a'> 50.340 in - 478
tnxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
37 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX (918) 295-0265
1 P„ / W. controls
Redundant Hi 1 Design Data Tension
Section
Elevation
Site
L
L.
K11r
A
P„
Ratio
No.
P.
ft
ft
ft
in
K
K
W.
T10
80-60
L2 1/2x2 1/2x3/16
519"
5'9"
88.7
0.902
0.036
29.225
0.001'
Tll
60-40
L212x21/2x3/16
6'3"
6'3"
96.4
0.902
0.029
29.225
0.0�/01'
10
T12
40-20
L21/2x212x3/16
6.9"
6'9"
104.1
0.902
0.032
29.225
0.001'
l/
T13
20 - 0
L2 12x2 1/2x3/16
7'3"
7'3"
111.8
0.902
0.026
29.225
0.001 '
1 P" / �P„ controls
Inner Bracing Design Data Tension
Section
Na.
Elevation
ft
Size
L
,/t
L.
ft
Kl/r
A
in'
P.
K
¢P„
K
Ratio
P.
Apr
T10
80-60
2L2x2x3/16x3/8
11'6"
11'6"
223.7
1.430
0.018
46.332
0.000'
2L'a' > 66.092 in - 306
Tll
60-40
2L2xW/16x3/8
12'6"
12'6"
243.1
1.430
0.014
46.332
0.0001
2L'a' > 71.840 in - 357
T12
40-20
2L2 12x2 1/20/160/8
13'6"
13'6"
208.2
1.800
0.017
58.320
0.000'
21,'a'>77.304 in-408
T13
20 - 0
2L2 1/2x2 1/2x3/16x3/8
14'6"
14'6"
223.6
1.800
0.012
58.320
0.000,
2L'a' > 83.030 in - 459
1 P" / �P" controls
Section Capacity Table
Section
Elevation
Component
Size
Critical
P
Opal..
%
Pass
No.
ft
Type
Element
K
K
Capacity
Fail
TI
250-240
Leg
2
1
-3.633
51.751
7.0
Pass
T2
240 -220
Leg
2 12
19
-30.407
70.833
42.9
Pass
13
220 - 200
Leg
3
40
-62.513
144.956
43.1
Pass
T4
200 -180
Leg
3 1/4
61
-97.541
192.479
50.7
Pass
T5
180 -160
Leg
3 1/4
82
-132.221
262.734
50.3
Pass
T6
160 - 140
Leg
3 1/2
121
-173.775
321.973
54.0
Pass
tnxTower
ob
d 77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
38 of 39
B+T Group
1717 S. Boulder, Suite 300
Project
Date
14:12:19 01 /23/19
Client
Designed by
Tulsa, OK 74119
Phone: (918) 587-4630
FAX.. (918) 295-0265
Crown Castle
Kiran
Section
Elevation
Component
Size
Critical
P
¢Pdio„
%
Pass
No
,Jt
Type
Element
K
K
Capacity
Fail
T7
140 - 120
Leg
3 3/4
160
-227.097
386.416
58.8
Pass
T8
120 - 100
Leg
4
199
-287.506
455.948
63.1
Pass
T9
100 - 80
Leg
4 114
238
-350.249
530A81
66.0
Pass
TIO
80-60
Leg
41/2
277
-397.527
609.947
65.2
Pass
TH
60 - 40
Leg
4 3/4
328
461.048
694.293
66.4
Pass
T12
40 -20
Leg
4 3/4
379
-524.438
694.293
75.5
Pass
T13
20-0
Leg
5
430
-587.351
783.476
75.0
Pass
Tl
250-240
Diagonal
L2x2x3/16
7
-2.270
16.441
13.8
Pass
15.1 (b)
T2
240-220
Diagonal
L212x21/2x3/16
22
-4.620
18.705
24.7
Pass
26.6 (b)
T3
220-200
Diagonal
L2 I/W 1/2x3/16
43
-5.850
15.126
38.7
Pass
T4
200-180
Diagonal
L3x3x3/16
64
-7.380
19.745
37A
Pass
40.9 (b)
T5
180 - 160
Diagonal
2L2 12x2 12x3/16x3/8
86
-9.781
32.930
29.7
Pass
. T6
160 - 140
Diagonal
2L2 12x2 12z3/16x3/8
125
-12.554
27.196
46.2
Pass
T7
140-120
Diagonal
2L212x21/20/160/8
164
-17.189
22.693
75.7
Pass
T8
120- 100
Diagonal
2L3x3x3/16x3/8
203
-18.950
32.178
58.9
Pass
T9
100 - 80
Diagonal
2L3x3x5/16x3/8
'242
-21.330
45.167
47.2
Pass
TIO
80-60
Diagonal
2L3x3x3/16x3/8
281
-27.609
52AOO
52.7
Pass
76.4 (b)
Tll
60 -40
Diagonal
2L3x3x3/16x3/8
332
-28.755
49.847
57.7
Pass
79.8 (b)
T12
40-20
Diagonal
2L3x3xl/4x3/8
383
-29.733
63.962
46.5
Pass
62.3 (b)
T13
20 -0
Diagonal
2L3x3xl/4x3/8
434
-30.387
59.676
50.9
Pass
63.9 (b)
T5
180 - 160
Horizontal
L2x2x3/16
85
-2.649
5.536
47.9
Pass
T6
160-140
Horizontal
L21/2x212x3/16
124
-3.304
8.292
39.9
Pass
T7
140- 120
Horizontal
L3x3x3/16
169
4.118
11.323
36A
Pass
T8
120- 100
Horizontal
L3x3x3/16
202
-4.991
9.073
55.0
Pass
T9
100 - 80
Horizontal
L3x3xl/4
241
-6.074
9.687
62.7
Pass
TIO
80-60
Horizontal
2L212x21/2x3/16x3/8
280
-6.894
16.668
41.4
Pass
TH
60-40
Horizontal
2L212x212x3/16x3/8
331
-7.996
14.124
56.6
Pass
T12
40-20
Horizontal
2L212x21/2x3/16x3/8
382
-9.095
12.100
75.2
Pass
T13
20-0
Horizontal
2L3x3x3/16x3/8
433
-10.186
17.817
57.2
Pass
T1
250 - 240
Top Girt
L2x2x3/l6
6
-0.206
7.543
2.7
Pass
TIO
80 - 60
Redund Harz 1
2L2x2x3/16x3/8
282
-6.896
33.446
20.6
Pass
Bracing
Tl l
60 - 40
Redund Horz I
Bracing
T12
40 - 20
Berland Horz 1
Bracing
T13
20 - 0
Redund Horz 1
Bracing
TIO
'80-60
Redund Ding
Bracing
T11
60 - 40
Redund Diag 1
Bracing
T12
40 - 20
Redund Diag 1
Bracing
T13
20 - 0
Redund Diag 1
Bracing
TIO
80 - 60
Redund Hip 1
Bracing
Tit
60 - 40
Redund Hip I
Bracing
T12
40-20
Redund Hip 1
Bracing
T13
20 - 0
Redund Hip I
Bracing
2L2x2x3/16x3/8
333
-7.997
29.757
26.9
Pass
2L2x2x3/l6x3/8
402
-9.097
25.730
35.4
Pass
2L2x2x3/l6x3/8
435
-10.187
22.329
45.6
Pass
2L2x2x3/16x3/8
309
4.684
19.419
24.1
Pass
2L2x2x3/16x3/8
360
-5.247
17.599
29.8
Pass
2L2x2x3/16x3/8
411
-5.798
15.933
36.4
Pass
2L2x2x3/16x3/8
462
-6.333
14.506
43.7
Pass
L212x212x3/16
327
-0.039
13.951
0.3
Pass
L212x212x3/16
378
-0.034
11.808
0.3
Pass
L2 1/2x2 120/16
429
-0.038
10.124
0.4
Pass
L2 1/2x2 12x3/16
480
-0.033
8.775
0.4
Pass
MxToweY
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
39 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01123119
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FiLY.' (918) 295-0265
Section
Elevation
Component
Size
Critical
P
oParm•.
%
Pass
No.
ft
Type
Element
K
K
Capacity
Fail
TS
180 - 160
Inner Bracing
L2x2x3/16
96
-0.003
5.084
0.1
Pass
T6
160 - 140
Inner Bracing
L2x2x3/16
133
-0.005
3.857
0.2
Pass
T7
140-120
hmer Bracing
L2 1/2x2 1/2x3/16
174
-0.004
6.025
0.2
Pass
T8
120 - 100
Inner Bracing
L2 12x2 1/2x3/16
213
-0.005
4.852
0.2
Pass
T9
100-80
Inner Bracing
L3x3x3/16
252
-0.008
6.992
0.2
Pass
T10
80 - 60
Inner Bracing
2L2x2x3/16x3/8
306
-0.030
8.447
0.4
Pass
I'll
60 - 40
honer Bracing
2L2x2x3/16z3/8
357
-0.026
7.155
0.4
Pass
T12
40-20
Inner Bracing
2L21/2x212x3/16x3/8
408
-0.032
11.751
0.3
Pass
T13
20-0
Inner Bracing
2L212x21/20/160/8
458
-0.027
10.199
0.3
Pass
Summary
Leg (T12)
75.5
Pass
Diagonal
79.8
Pass
(TI1)
Horizontal
752
Pass
(TI2)
Top Girt
2.7
Pass
(Tl)
Redund
45.6
Pass
Horz 1
Bracing
(T13)
Redund
43.7
Pass
Diag I
Bracing
(T13)
Redund Hip
0.4
Pass
•
I Bracing,
(T12)
Inner
0.4
Pass
Bracing
(Till
Bolt Checks
79.8
Pass
aaTmrr_—
Ios
P...
Program Version 8.0.5.0
APPENDIX B
BASE LEVEL DRAWING
1 s� ro 1]0
1-1/]1' ro
s YN 4
s/o• m lu
e 1-s/a•ro Jro to
tl9 1-
Doan wxsmlx
I) 6/6 TO 80
BUSINESS UNIT : 813812
APPENDIX C
ADDITIONAL CALCULATIONS
PROJECT 813812 - FL WEST FORT PIERCE FL
SUBJECT 475131 Rev. 0 f B+T GRP
DATE O1123/19 TIA-222-H Tulsa, K 7g11170 S. 95uite 300
(918) 587-4630
UTPmj.No.: 77034.008.01
Redundant Connection Analvsis
Elevation Member Size
Member Block Shear
TeadngBMember Bead
Soft Shear
%Capacity
tPn
Loatl
Rn
Laatl
Rm
Load
Redundant Horzontal (1) Design Data (Compression)
80-60 2L212x3/l6x3/8
26.10
6.896
27.61
6.90
26.4%
Pass
60-40 2L2x2x3tl6x3/8
26.10
7.997
27.61
8.00
30.6%
Pass
40-20 2L2>QX3/l6x3/8
26.10
9.097
27.61
9.10
34.9%
Pass
20-0 2L2x2x3ll6x3/8
26.10
10.187
27.61
10.19
39.0%
Pass
Redundant Diagonal (1) Design Data (Compression)
80-60 2L2x2x3/16x3/8
26.10
4.684
27.61
4.68
17.9%
Pass
60-40 2L2)(Wtl6a3/8
26.10
5.247
27.61
525
20.1%
Pass
40-20 2LW01160/8
26.10
5.798
27.61
5.80
22.2%
Pass
20-0 2L2)2x3/i6x3/8
26.10
6.333
27.61
6.33
24.3%
Pass
Redundant Hip (1) Design Data (Compression)
80-60 L21/HQ 112x3/16
13.05
0.039
13.81
0.04
0.3%
Pass
60-40 L211W 1/2x3/16
13.05
0.034
13.81
0.03
0.3%
Pass
40-20 L21/W 1/20/16
13.05
0.038
13.81
0.04
0.3%
Pass
20-0 L21021/Dc3116
13.05
0.033
13.81
0.03
0.3%
Pass
Redundant Horizontal (1) Design Data (Tension)
80-60 21DQY3/16x3/8
15.75
6.90
22.19
6.896
27.61
6.90
418%
Pass
60-40 2L2x2x3tl6x3/8
15.75
8.00
22.19
T997
27.61
8.00
50.8%
Pass
40-20 2L2 3/16018
15.75
9.10
22.19
9.097
27.61
9.10
57.8%
Pass
20-0 2L2x2x3tl6x3/8
15.75
10.19
22.19
10.187
27.61
10.19
64.7%
Pass
Redundant Diagonal (1) Design Data (Tension)
80-60 2L2x2x3tl6x3/8
15.75
4.68
22.19
4.684
27.61
4.68
29.7%
Pass
60-40 2L2x2x3/16x3/8
15.75
5.25
22.19
5.247
27.61
5.25
33.3%
Pass
40-20 2L2x2x3tl6x3/8
15.75
5.80
2.2.19
5.798
27.61
5.80
36.8%
Pass
20-0 2L2x2x3/l6x3/8
15.75
E33
22.19
6.333
27.61
6.33
40.2%
Pass
Redundant Hip (1) Design Data (Tension)
80-60 L212R 1/20/16
9.91
0.04
11.09
0.036
13.81
0.04
0.4%
Pass
60-40 L21/2x21/2x3/16
9.91
0.03
11.09
0.029
13.81
0.03
0.3%
Pass
40-20 L21/2ti21/2z3116
9.91
0.03
11.09
0.032
13.81
0.03
0.3%
Pass
20-0 L21 W1¢ 3/16
9.91
0.03
11.09
0.026
13.81
0.03
0.3%
Pass
Ccop ft
Project 1 1
BU # 813812
Site Namel FL WEST FORT•PIERCE, FL
Order # 475131, 'Rev 0
Jow.er Information
TowerTypel Self _Support _
TIA-222 RevJ H _ ❑✓ Apply TIA-222-H Section 15.5
Applied Loads
Comp. I uplift
Axial k 617.00 518.00
Shear k 74.00 64.00
Anchor Rod Data
Quantity:
6
Diameter (in):
2.25
Material Grade:
A36
Grout Considered
= No
I., (In).
2
Eta Factor, q
Thread T e:
.tion:
N-Included
Confi ur
Symmetrical
�Anchor • 1 1 Results
Axial, Pu_c (kips)102.83
Shear, Vu kips
12.33
Moment, Mu kip -in
-
Axial Cap., Pn_c (kips)
117.00
Shear Cap., (tVn (kips)
35.10
Moment Cap., 4)Mn (kip -in)
-
Stress Rating
95.5%
Fy=36 ksi Fu=58 ksi
Not Considered, lar<=1(d)
Pass
Mplate - version 3.5.0 Analysis Date: 1/23/2019
PROJECT 77034.008.01 - FL West Fort Pierce, FL
SUBJECT Foundation Comparison
DATE 01/23/19 PAGE 1 OF 1
SST
JfB+T GRP
1717 S. Boulder, Suite 300
Tulsa, OK 74119
(918)587-4630
Initials
Factored TnxTowers Reactions
Down = 617 k
Uplift = 518 k
Un-Factored Original Design Reactions
Down = 627.5 k
Uplift = 542.1 k
Percent Capacity
Down = 69.4% Pass
Uplift = 67.4% Pass
ASCE
W MIM SOCIEW OF OM' ENOWr90
Address:
No Address at This
Location
ASCE 7 Hazards Report
Standard: ASCE/SEI 7-10 Elevation: 18.55 ft (NAVD 88)
Risk Category: II Latitude: 27.445706
Soil Class: D - Stiff Soil Longitude: -80.412942
BMp x
21
�
}
y
-
• a
-
l0
s
rY•,`2i
9
\\Itl� �
�
\.a
1
Wind
Results:
Wind Speed:
157 Vmph
10-year MRI
87 Vmph
25-year MRI
105 Vmph
50-year MRI
117 Vmph
100-year MRI
129 Vmph
Data Source:
ASCE/SEI 7-10, Fig. 26.5-1A and Figs. CC-1—CC-4, incorporating errata of
March 12, 2014
Date Accessed:
Tue Jan 22 2019
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear
interpolation between contours. Wind speeds are interpolated in accordance with the 7-10 Standard. Wind speeds
correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability =
0.00143, MRI = 700 years).
Site is in a hurricane -prone region as defined in ASCE/SEI 7-10 Section 26.2. Glazed openings shall be protected
against wind-borne debris as specified in Section 26.10.3.
Mountainous terrain, gorges, ocean promontories, and special wind regions should be examined for unusual wind
conditions.
hitos://asce7hazardtooLonline/ Page 1 of 3 Wed Jan 23 2019
ASCE
AMDIIC SOCIETYOF DN MUNEEAS
Seismic
Site Soil Class:
D - Stiff Soil
Results:
Ss :
0.057
SDs
0.061
S,
0.029
SW
0.047
Fa
1.6
TL
8
F
2.4
PGA:
0.027
SMs
0.091
PGA M :
0.043
SM1
0.07
FPGA
1.6
le
1
Seismic Design Category A
0:1n
a.o
0.0
0.0
00
a.a
0.0
0.0
0.0
U
MCER Response Spectrum
Sa(g) vs T(s)
0V
a.a
a.o
o.p
0.9
9.a
o.a
Desiqn Response Spectrum
Sa(9) vs T(s)
Data Accessed: Tue Jan 22 2019
Date Source: USGS Seismic Design Maps based on ASCE/SEI 7-10, incorporating
Supplement 1 and errata of March 31, 2013, and ASCE/SEI 7-10 Table 1.5-2.
Additional data for site -specific ground motion procedures in accordance with
ASCE/SEI 7-10 Ch. 21 are available from USGS.
httos:/Iasce7hazardtool. online/
Page 2 of 3
Wed Jan 23 2019
ASCE
Ice
Results:
Ice Thickness:
Concurrent. Temperature:
Gust Speed:
Data Source:
Date Accessed:
0.00 in.
25 F
30 mph
Standard ASCEISEI 7-10, Figs. 10-2 through 10-8
Tue Jan 22 2019
Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys
and gorges may exceed the mapped values.
Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds,
for a 50-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain.
Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice
thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may
exceed the mapped values.
The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided "as is" and without warranties of
any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers;
or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from
reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability,
currency, or quality of any data provided herein. Any third -party links providedby this Tool should not be construed as an endorsement,
affiliation, relationship, or sponsorship of such third -party content by or from ASCE.
ASCE does not intend,. nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent
professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of rare required of such
professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard.
In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors,
employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential
damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by
law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data
provided by the ASCE 7 Hazard Tool.
httos://asce7hazardtool.online/ Page 3 of 3 Wed Jan 23 2019
Date: January 23, 2019
Andera Slaughter
Crown Castle
8000 Avalon Blvd Suite 700
Alpharetta, GA 30009
Subject.
Carrier Designation:
Crown Castle Designation:
Engineering Firm Designation:
Site Data:
Dear Andera Slaughter,
SCANNED
BY
St. Lucie County
Structural Analysis Report
AT&T Mobility Co -Locate
Carrier Site Number:
Carrier Site Name:
Crown Castle BU Number:
Crown Castle Site Name:
Crown Castle JDE Job Number:
Crown Castle Work Order Number:
Crown Castle Order Number:
B+T Group Project Number:
Jf3 B+T GRP
B+T Group
1717 S. Boulder, Suite 300
Tulsa, OK 74119
(918)587-4630
10080502
WFTPIERCE (FP30)
813812
FI West Fort Pierce
553175
1684679
475131 Rev. 0
VVIRY'Killer-III
8701 Orange Avenue, Ft Pierce, St. Lucie County, FL
Latitude 270 26' 44.54", Longitude -800 24' 46.59"
250 Foot - Self Support Tower
B+T Group is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the
above -mentioned tower.
The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we
have determined the tower stress level for the structure and foundation, under the following load case, to be:
L05: Proposed Equipment Configuration
Sufficient Capacity
This analysis utilizes an ultimate 3-second gust wind speed of 157 mph as required by the 2017 Florida Building
Code, 6th Edition, Applicable Standard references and design criteria are listed in Section 2 - Analysis Criteria.
Structural analysis prepared by: Jacob Johnson, E.I.T.
Respectfully submitted by: B+T Engineering, Inc.
COA: 27496; Expires: 2/28/2019
20039108010n1H00
3H1 JO W1181SHOdS3d 3H13dy
SININ IV do Sd3H31Sbd 031730H00,.�```�IN.. i 1KQ,,4j
� \C
EN
FILE --* �A At
w�
F�
ST. LUCfE COUP
BUILDING DIVIS
FOR
MUST BE 10EPTON JOB Op
> INSPECTION wILL BE MADE
tA811 1=LAWarjD au. t�HQPOSfiG,t�te��.,
r�r=����rroa►�Yc�la�s.� s
hLA/�J_1mG9 iY F11:6D INSPE.. RS TiiiiT
MAYDO. NECES3ARYlN0i4
John W. Kelly, P.E.
tnxTower Report -version 8.0.5.0
250 Ft Self Support Tower Structural Analysis
Project Number 77034.008.01, Order 475131, Revision 0
TABLE OF CONTENTS
1) INTRODUCTION
2) ANALYSIS CRITERIA
Table 1 - Proposed Equipment Configuration
Table 2 - Other Considered Equipment
3) ANALYSIS PROCEDURE
Table 3 - Documents Provided
3.1) Analysis Method
3.2) Assumptions
4) ANALYSIS RESULTS
Table 4 - Section Capacity (Summary)
Table 5 — Tower Component Stresses vs. Capacity - LC5
4.1) Recommendations
5) APPENDIX A
tnxTower Output
6) APPENDIX B
Base Level Drawing
7) APPENDIX C
Additional Calculations
January 23, 2019
CCI BU No 813812
Page 2
tnxTower Report - version 8.0.5.0
250 Ft Self Support Tower Structural Analysis
Project Number 77034.008.01, Order 475131, Revision 0
1) INTRODUCTION
January23, 2019
CC/ BU No 81381�
Page 3
This tower is a 250 ft. Self -Support tower designed by FWT Inc. in June of 1998. The tower was originally
designed for a wind speed of 110 mph per TIA/EIA-222-F. The tower has been modified per reinforcement
Drawings prepared by B&T Engineering, in May of 2008.
2) ANALYSIS CRITERIA
TIA-222 Revision:
TIA-222-H
Risk Category:
II
Wind Speed:
157 mph
Exposure Category:
C
Topographic Factor:
1
Service Wind Speed:
60 mph
Table 1 - Proposed Equipment Configuration
Mounting
Level (ft)
Center
Line
Elevation
(ft)
Number
of
Antennas
Antenna
-Manufacturer
Antenna Model
Number
of Feed
Lines
Feed
Line Siie
(in)
6
Commscope
SBNHH-1D85B
3
Ericsson
RRUS 32
3
Ericsson
RRUS 4449 B5/B12
12
1-5/8
3
Ericsson
RRUS 8843 B2/1366A
143.0
146.0
6
3
3/4
318
1
Kathrein
80010965K
2
Kmw Comm.
ET-X-UW-68-14-65-18-IR-AT
1
5/16
2
Raycap 7
DC6 48-60-18-8C
1
Raycap
DC6-48-60-18-8F
143.0
3
Connect -It
PVFM12-3-3-96-3 Mount
Table 2 - Other Considered Equipment
Mounting
Level (ft)
Center
Line
Elevation
Number of
Antennas
Antenna
Manufacturer
Antenna Model
NumberWLimSize
of Feed(ft) Lines
6
Commscope
E15R05P19
243.0
244.0
12
1
1-5/8
1-1/4
3
Ericsson
RRUS12/RRUS A2
6
Jma Wireless
X7CQAP-665-VRO
1
Raycap
RXXDC-3315-PF-48
243.0
6
Css
DBC-7CAP
1
Sector Mount [SM 402-3]
133.0
3
Ericsson
80OMHZ SMR FILTER
3
Ericsson
RRUS-1180OMHZ
130.0
132.0
3
Commscope
TTTT65AP-1XR
3
1-1/32
3
Rfs Celwave
APXVSPP18-C
131.0
3
nokia
FZHJ-RRH
1
7/8
3
ericsson
RRUS 31 B25
130.0
9
rfs celwave
I ACU-A20-N
1
I Sector Mount ISM 702-3]
tnxTower Report - version 8.0.5.0
250 Ft Self Support Tower Structural Analysis
Project Number77034.008.01, Order475131, Revision 0
3) ANALYSIS PROCEDURE
Table 3 - Documents Provided
January 23, 2019
CCI BU No 813812
Page 4
Document
Remarks
Reference
Source
Online Order Information
AT&T Mobility Co -Locate, Revision # 0
475131
CCI Sites
Tower Manufacturer Drawing
FWT, Design No. S98-0541-A
906968
CCI Sites
Tower Modification Drawing
B&T Engineering, Project No.77034
2271344
CCI Sites
Post Modification Inspection
VSI, Project Number 080878.01
2323138
CCI Sites
Foundation Drawings
Information Not Available
Geotech Report
PSI, Inc. Project No.397-85068-2
1 115206
CCI Sites
Antenna Configuration
Crown CAD Package
I Date: 01/18/2019
CCI Sites
3.1) Analysis Method
tnxTower (version 8.0.5.0), a commercially available analysis software package, was used to create a
three-dimensional model of the tower and calculate member stresses for various loading cases.
Selected output from the analysis is included in Appendix A.
3.2) Assumptions
1) The tower and structures were built and have been maintained in accordance with the
manufacturer's specification.
2) The configuration of antennas, transmission cables, mounts and other appurtenances are as
specified in Tables 1 and 2 and the referenced drawings.
3) Mount areas and weights are assumed based on photographs provided.
4) The existing base plate grout was not considered, in this analysis.
This analysis may be affected if any assumptions are not valid or have been made in error. B+T
Group should be notified to determine the effect on the structural integrity of the tower.
4) ANALYSIS RESULTS
Table 4 - Section Capacity (Summary)
Section
No.
Elevation
(ft)
Component Type
Size
Critical
Element
P (K)
SF•P_allow (K)
�o
Capacity
Pass
/ Fail
T1
1250 - 240
I Leg
1 2
1
-3.633
I 51.751
I 7.0
Pass
T2
240-220
1 Leg
1 21/2
1 19
1 -30.407
1 70.833
1 42.9
1 Pass
T3
220-200
1 Leg
3
1 40
1 -62.513
1 144.956
1 43.1
1 Pass
T4
200 - 180
1 Leg
3 114
61
1 -97.541
1 192.479
1 50.7
1 Pass
T5
180 -160
1 Leg
3 114
82
1 -132.221
1 262.734
50.3
Pass
T6
1 160-140
Leg
31/2
121
1 -173.775
321.973
54.0
Pass
T7
140 -120
1 Leg
1 3 3/4
1 160
1 -227.087
1 386.416
58.8
Pass
TS
120 -100
1 Leg
4
1 199
-287.506
1 455.948
1 63.1
1 Pass
T9
100-80
Leg
41/4
238
-350.249
530.481
66.0
Pass
T10
80 - 60
Leg
4 112
277
-397.527
609.947
65.2
Pass
T11
60 - 40
Leg
4 3/4
328
-461.048
1 694.293
66.4
Pass
T12
40 - 20
Leg
4 3/4
1 379
-524.438
1 694.293
1 75.5
1 Pass
T13
20 - 0
Leg
5
430
-587.351
783.476
75.0
Pass
T1
250 - 240
Diagonal
L2x2x3/l6
7
-2.270
16.441
138
Pass
T2
240-220
1 Diagonal
I L2 1/2x2 1/2x3/16
22
-4.620
18.705
24.7
Pass
tnxTower Report -version 8.0.5.0
250 Ft Self Support Tower Structural Analysis
Project Number77034.008.01, Order475131, Revision 0
January 23, 2019
CC/ BU No 81381 �
Page 5
Section.
No.
Elevation
(g)
Component Type..
Size,
Critical
Element
P(K)
SF`P_allow (K)
%
Capacity
Pass.
/Fail
26.6 (b)
T3
220-200 1
Diagonal
I L2 1/2x2 1/2x3/16
43
-5.850
15.126
38.7
Pass
T4
200 -180
Diagonal
L3x3x3/l6
64
-7.380
19.745
37.4
40.9 (b)
Pass
TS
180-160 1
Diagonal
1 21-21/2x21/24/164/8
86
-9.781
32.930
29.7
Pass
T6
160 - 140 1
Diagonal
1 21-2 112x2 1/2x3/16x3/8
125
-12.554
27.196
46.2
Pass
T7
140-120 1
Diagonal
1 21-21/2x21/24/164/8
164
-17.189
22.693
75.7
Pass
TB
120 - 100
1 Diagonal
I 2L3x3x3/16x3/8
203
-18.956
32.178
58.9
Pass
T9
100 - 80
Diagonal
2L3x3x5/16x3/8
242
-21.330
45.167
47.2
Pass
T10
80-60
Diagonal
2L3x3x3/16x3/8
281
-27.609
52.400
5
76.42.7(b)
Pass
T11
60-40.
Diagonal
2L3x3x3/16x3/8
332
-28.755
49.847
57.7
79.8 (b)
Pass
T12
40-20
Diagonal
2L3x3xl/4x3/8
383
-29.733
63.962
46.5
62.3 (b)
Pass
T13
20 - 0
Diagonal
2L3x3xl/4x3/8
434
-30.387
59.676
50.9
63.9 (b)
Pass
T5
180 - 160
1 Horizontal
I L2x2x3/16
1 85
1 -2.649
1 6.536
1 47.9
Pass
T6
160 - 140
1 Horizontal
I L2 I1W 1/2x3/16
1 124
1 -3.304
1 8.292
1 39.9
Pass
T7
140 - 120
1 Horizontal
I L3x3x3116
1 169
1 -4.118
1 11.323
1 36.4
1 Pass
T8
120 - 100
1 Horizontal
L3x3x3/16
202
-4.991
9.073
55.0
T9
100 - 80
Horizontal
L3x3xl/4
241
-6.074
9.687
62.7
T10
80-60
Horizontal
2121/2x21/2x3/16x3/8
280
-6.894
16.668
41.4
HPa�
T11
60-40
Horizontal
2L21/2x21/2x3/16x3/8
331
-7.996
14.124
56.6
T12
40-20.
Horizontal
2121/2x21/2x3/16x3/8
382
-9.095
12.100
.75.2
T13
20-.0
Horizontal
2L3x3x3/16x3/8
433
-10.186
17.817
57.2
Pass
T1
250-240
1 Top Girt
L2x2x3/16
6
-0.206
7.543
2.7
Pass
T10
80-60
Redund Horz 1 Bracing
2L2x2x3/16x3/8
282
-6.896
33.446
20.6
Pass
T11
60-40
Redund Horz l Bracing
2L2x2x3/16x3/8
333
-7.997
29.757
26.9
Pass
T12
40 - 20
Redund Horz 1 Bracing
2L2x2x3/16x3/8-
402
-9.097
25.730
35.4
Pass
T13
20 - 0
Redund Horz 1 Bracing
2L2x2x3/16x3/8
435
-10.187
22.329
45.6
Pass
T10
80 - 60
Redund Diag 1 Bracing
2L2x2x3/16x3/8
309
-4.684
19.419
24.1
Pass
T11
60-40
Redund Diag 1 Bracing
2L2x2x3/l6x3/8
360
-5.247
17.599'
1 29.8
Pass
T12
40 - 20
Redund Diag 1 Bracing
2L2x2x3/16x3/8
411
-5.798
15.933
36.4
Pass
T13
20 - 0
Redund Diag 1 Bracing
2L2x2x3ll6x3/8
462
-6.333
14.506
43.7
Pass
T10
80-60
Redund Hip l Bracing
L21/2x21/2x3/16
327
-0.039
13.951
0.3
Pass
T11
60-40
Redund Hip l Bracing
L2 1/2x2 1/2x3/16
378
-0.034
11.808
0.3
Pass
T12
40 - 20
Redund Hip 1 Bracing
L2 1/2x2 1/2x3/16
429
-0.038
10.124
0.4
Pass
T13
20 - 0
Redund Hip 1 Bracing
L2 112x2 1/2x3/16
480
-0.033
8.775
0.4
Pass
T5
180 - 160
1 Inner Bracing
L2x2x3/16
96
-0.003
5.084
0.1
Pass
T6
160 - 140
1 Inner Bracing
L2x2x3/16
133
-0.005
3.857
0.2
T7
140 - 120
Inner Bracing
L2 112x2 1/2x3/16
174
-0.004
6.025
0.2
PJ
TS
120 - 100
Inner Bracing
L2 112x2 112x3/16
213
-0.005
4.852
0.2
T9
100- 80
Inner Bracing
L3x3x3/16
252
-0.008
6.992
0.2
Pass
T10
80- 60
Inner Bracing
2L2x2x3/16x3/8
306
-0.030
8.447
0.4
Pass
T11
60 - 40
Inner Bracing
2L2x2x3/l6x3/8
357
-0.026
7.155
0.4
Pass
tnxTower Report - version 8.0.5.0
250 Ft Self Support Tower Structural Analysis
Project Number 77034.008.01, Order 475131, Revision 0
January 23, 2019
CCI BU No 813812
Page 6
Section
No.
Elevation
(h)
Component Type
Size
Critical
Element
P (K)
SF`P_allow (K)
%
Capacity
Pass
/ Fail
T12
140-20
I Inner Bracing
121.21/2x21/2x3/16x3/8
I 408
I -0.032
I 11.751
I 0.3
IPass
T13
20-0
Inner Bracing
21-21/2x21/2x3/16x3/8
458
-0.027
10.199
0.3
Pass
Summary
Leg (T12)
75.5
Pass
Diagonal (T1 1)
79.8
Pass
Horizontal (T12)
75.2
Pass
Top Girt(T1)
2.7
Pass
Redund Horz 1
Bracing (T13)
45.6
Pass
Redund Diag 1
Bracing (T13)
43.7
Pass
Redund Hip 1
Bracing (T12)
0.4
Pass
Inner Bracing (T11)
0.4
Pass
Bolt Checks
79.8
Pass
Rating =
79.8
Pass
Table 6 - Tower Component Stresses vs. Capacity - LC5
Notes
Component
Elevation (ft)
% Capacity
Pass / Fail
1
Redundant Connections
0-80
64.7
Pass
1
Anchor Rods
Base
95.5
Pass
1,3
Base Foundation
Base
69.4
Pass
Structure Rating (max from all components) = 95.5%
Notes:
1) See additional documentation in "Appendix C - Additional Calculations" for calculations supporting the % capacity
consumed.
2) Rating per TIA-222-H Section 15.5.
3) Foundation capacity determined by comparing analysis reactions to original design reactions.
4.1) Recommendations
The tower and its foundations have sufficient capacity to carry the proposed load configuration. No
modifications are required at this time.
tnxTower Report - version 8.0.5.0
:rct
C
a
61
®
e
F
r+
Na{
Sl�
}
d
2
Q
z
Frc
rc
E
m
i z
d
i m
a
N
a5
N-
F
N n
m
d �
C
F
w
It
e
7
m
�
�
F
�
m
�
A
r
2500ft
2400 ft
nao a
2500 nft
160_0 ft
1600 ftft
1400 ft L'1N
W Q
1200 ft
1000 ftft
60_0ft
60_0ft
SYMBOL LIST
MARK SIZE MARK SIZE
A lSQx3nfi
TOWER DESIGN NOTES
1. Tower designed for Exposure C to the TIA-222-H Standard.
2. Tower designed for a 157 mph basic wind in accordance with the TIA-222-H Standard.
3. Deflections are based upon a 60 mph wind.
4. Tower Risk Category II.
5. Topographic Category 1 with Crest Height of 0'
6. TIA-222-H Annex S
7. TOWER RATING: 79.8%
ALL REACTIONS
AREFACTORED
ao.o ft MAX. CORNER REACTIONS AT BASE:
DOWN: 617 K
SHEAR: 74 K
UPLIFT.: -518K
SHEAR: 64 K
20.0 n AXIAL
99I1KK
SHEAR/ /J \ MOMENT
125 K ��� ���,,, ` 15176 kip-H
0.0 n
TORQUE 130 kip-ft
REACTIONS -157 mph lMND
B+T Group
1717 S. Boulder, Suite
3-T GRP Tulsa, OK 74119
Phone: (918) 587-4630
rO34.00&01 -
Crown Castle
jc�e' TIA-222-H oate:0123/19 ISCa1a: NTS
Plot Plan
Total Area - 0.09 Acres
Base Elewg
67
77034.008.01- FL WEST FORT PIERCE, FL (BU# 81381
1717 S. Boulder, Suite
s-T GRP Tulsa, OK 74119
Phone: (918) 587-4630
C
O
d
W
TIA-222-H - 157 mph Exposure C
Leg Capacity Leg Compression (K)
1000 500 Minimum 4 Mmdmum-> -500 -1000
250 259
1 I I I I I 1 I 1 I I I I I I I
I I I 1 I I I I I I
240 240
—I —--1 —r —r —I
1 1 1 1 1 1 I 1 1 I 1 1 1
1 1 1 1 1 I 1 1 1 1 1
1 I 1 I 1 1 1 1 1 1
I I I I I I I I I I I
I I I I I I I I I I
1 I I
I I 1 I I I I I I I
I I I I I I I I I I I 1 I I
I I I I I I I I I I 1 I I
I I I I I I I I I I I I I I
I I I I 1 I I I I I I I I I 1
1 1 Oa
1 1 I 1 I 1 1 1 1 1 I
1 I 1 1 f I 1 I 1 1 1
1 1 1 1 1 I 1 1 1 1
I I I I I I I I I
160 1 1 1 1 1 1 1 1 1 1 1 1 ISO
I I I I I 1 I I I I I
I I I I I I I I
I I I I I I I I I
I I I I I I 1 I
1 I
1 1 1 1 1 1 1 1 1 1 160
I I 1 I I I
1 1 1 1 1 1 I I I I
1 1 I I I I 1 1 1 I 1 I 1 1
I I I I
1 1 1 1 1 1 1
120 1 ___,___1120
1 1 1 1 1 1 1 1
top 1 1 1 1 1 1 100
-1___r _ ___r___r _1___r___ ___r__l__-.�-__r_ _�___r_.__r
1 I 1 1 1 1 I 1 1 I 1 1 I
t I 1 1 1 1 i 1
1 1 1 1 1 1 1 I I 1 1 1
1 1 1 1 1 1 1 I I 1 1 1
1 1 1 1 1 1 I 1 1 1
60 I I 1 1 1 1 1 a•
1 1 1 1 I 1 1 1 1 1 1
1 1 i i i i I
I I 1
1 1 1 1 1 I 1 I 1 1 1 1 1 1 1 I
I I b I 1 I I 1 I
I I 1 I I I I I I I I I
I I I I I 1 I I I I I
I 1 I I I 1 I I I I I
I I 1 I I I I I 1 I I I
I I I I I I I I I I I I
1 0'
I I I
1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 i 1 1 1 1 1 I
1 1 I 1 1 1 1 1 1 r 1 1 I
1 1 1 1 1 1 I 1 1 I
1 1 1 1 1 1
20 1 1 I I I
I I I I I 1 I I
I I I I 1 I I I I 1 I I
I I I I I I I I I 1 I I
I I I I I I I I I 1 I I
I I I I I I I I I I I I I I
I I I I I 1 I I I
n
1000 500-Mminum AMuimum-> -500 -1000
oTI vruup
1717 S. Boulder, Suite
3.T GRP Tulsa, OK 74119
Phone: (918) 587-4630
' - FL WEST FORT PIERCE, FL (BU# 81381
C
O
d
W
TIA-222-H - 157 mph Exposure C
Vx Vz
r
Global Mast Shear (K)
150
25
_
2a
I I I
1 I
I I I
I I
I I 1 1
I
11 I 1
11 I 1
I I I I
1 I 1
I I I
11 I 1
I I
I I
I I I I
I 1 I
11 1
1 1 I
I I I I
I I I I
I I I I
I I I I
1 1
1 1 1
1 1 I
$20
1 I 1 1
I I 1 I
I
I i 1
1 1
I I I I
I
i 1 1 1
I 1 1
I I I I
11 I 1
I I I I
1 1 1 1
1 1
1 1 I i
20
1 1
I I
I I
I I I
I I
1 1 1
I
I I I I
I I I
I
1 1 I 1
I
I I I
I I
I I I
I I
I I
I I
I I I I
I I I I
I I
I I I I
I I I
180
I
1 I
I I I I
I I
I
I I
I I I
I I I I
I I I
I I I I
I I I I
I I I I
I I I I
I
160
I
I I
I I
I
I I I I
I I
1 1 1
1 1
I I
I ( 1
1 i i
i
1 1
i
i I i I
i
1 1
I I I I
I
I I I I
r I
I I I a
11 I 1
I 11
1 1 I
1 I I
I I I I
I I I I
1zo
I
I I I I
I 1
i li i
I r
i i I
1 1 1
I I I
I I I
I I I I
I 11
I I I I
I I I
I I I
I I I
1 I I
I I
I I I I
I I
I I I
I I I I
1 I
I I I I
I I
I I I I
10
1
{
I
I I
1 I
I I 1
I 1 I
I I I I
1 I 1 1
I
I I I I
I I I I
I I I I
I I 1 1
I I I I
I I I I
1
I I I I
I I I I
I I I I
I I I I
I I
I I I I
I I I
I I I
I I
I I I I
I I
I
I I I I
I I I
I I I
If
I
I I I
I I I
I I I
I I
I I
00
I I I
I I I I
I
I I I
I I 'I I
I I I I
I I I I
1 I
1 1 1
I I I
1 1 1
I I I
I I
1 1 I 1
1 I
I I
I I
I I I
I
I 1
I I I I
I I
I I I I
I I
I I
I I I I
I I I
I I
I
I
1 1 1
11
11 I 1
11 I 1
I I I I
1 1 I
1 1 I
11 I 1
11 1
1 I 1
I I I I
1 I
1 1 1
28
1 I 1 1
I 1 1
1 1 I
1I
I I I
I I I
1 I
I I I I
I I
I-
I
I
I
0
I I I
I I
I I I
I 1
I I I I
1
Maximum Values
Mx Mz
r
Global Mast Moment (kip-ft)
50'
I I I I
I I I
I
I I I
I I
1 1 1
I I
I I
I
1 1
I I
aO•
I
I 1 I
1
I i 1
1 1
1 I 1
I I I I
I I I
1 I
I 1 1
I I I I
I I I I
I I I I
I I I I
I 1 I
I I 1 1
I I I I
a
11
11 1 1
I I I
I I
i I I
1 I
1 1 I
1 1 1
i 1
i 1
1 1 I
1
I
I
I I I I
I I
fia
I I I
I I
I I
I
I
I 1 I
I I I I
I
I I
I I I I
I I
I I I
I
I
I I I I
I I I
I I I I
I I I I
I I I
I I
I I
I I I
11
I I I
I
I I I
I I
1 i
I I 1 1
1 I I I
68'
1 1 1
1 I 1
I 1
1
1
1 1 1
1
1 1 1
1 1 1
I I
1
I I
1 1 1
ao
1
l l
I 1 I
I I I I
I 1 i
1 1 I
I I I I
I 1
f I I I
1
I I
i I
I I I
I 1
I
I
I I
I I I
1 I
I
I I
I I I
I
I I
I I I
I 1
I
I I
ma.
I I I I
1 I 1
1 I
I I I
I 1
I
I I I
I I I
i
I
I I I I
1 I
I I I
8'
1 1
______
I I
I I
1 1 I
I I
I 1
1
I I I
I
1 I
I I I
I
1
I
I
I I I
I I
I I I I
I I I I
I I I I
_J _L_J _L
_I _.I_ I _1
_ 1 _I _1 _I
O•
1
I 1 1
1
I
1 1
I
1 I
I 1 1
I I I
I I I I
I
I I I
I I I
I
1 I
I I I
I I I I
1 1
1 I
I I I I
I I I
l i l
I I I I
I I I
I I
I I
I 1
I
1 I
I I I I
1 r 1
I 1
I I 1
_ _
I I 1 1
__ I I I
1 I
11
I
I
I
I I
1 I
I I I
I I
I I I I
1 I
I I I I
I I I
I
I I I I
11
I I
I I
I I
I I
r DTI l](u"P
1717 S. Boulder, Suite
3-T GRR Tulsa, OK 74119
Phone: (918) 587-4630
NITS
TIA-222-H - Service - 60 mph
Maximum Values
c
0
m
d
W
Deflection (in)
I I I I
I I I
24
I I
� I �
I I I I
I � I
i
200 _1 _J _L _1
I I
I I I I
I I I
I I i
1fi0 '
I I
I I I I
I I I
� I �
fi0
I
I i I I
� I I
I I
I i i I
� I I
� I
120
I � I
I � I
100
80
I I �
� I �
I � �
I i I I
I I I
I I I
� I
I � I
I I I
I I I I
---------------------
I
I I I I
I I I
I i
I
I I I
I I I I
I i i
z 1 1
I � I
Tilt (deg)
I
7_r___I.7_r_r__�
I I I I
I I I I
I I I I
I I I I
I I
I I I I
I I I I
I I I I
I I I I
I
I I 1 1
I I I I
I I I
III
I I I I
I III
I I I I
iii"11111
I I I I
I I I I
I I I I
-1_4_F_
I I I I
I I I I
I I I I
I I I I
-4_4_F_
I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
-1-7-r-r---I-r-
I I I I
I I I I
I I I I
I I I I
-r--7-r-r-r
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
11 1
_r I_7_r___I_
I I I I
I I I I
I I I I
I I I I
I I
� r_r__7_r_r_r
I I I I
I I I
I I I I
I I I I
I
I I I I
I I I I
I I I I
I I I I
I I I I
_I_J_1_L_
I I I I
I I I I
I I I I
I I I I
J_J_L_L__J_L_L
I I I I
I I I I
I I I I
I I I I
_I_
I I I I
I I I I
I I I I
I I I I
4_ __�_.{_F_F__�_}_F
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I
I I I I
I I I I
I I I I
I I
_r _I 7_r___1_7_r_r__
I I I
I I I I
I I I I
I I I I
I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I
�_r_r_r
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
1717 S. Boulder, Suite
3-T GRP Tulsa, OK 74119
Phone: (918) 587-4630
0.15
Twist
--,--7--r -,-- --r--,
L_J__ __L_J__1__L_
I I I I I I I I
I I I 1 I I I I
I I I I I I I I
I I I I I I I I
__1__{
I I I I I I I 1
I I I I I I I
I I I I I I I I
I I I I I I I I
--1- r--r--1----r--I--r--r-
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I 1 I I
I I I I I I I I
I I I 1 I I I I
I I I I I I I I
I 1 1 I I 1 I
I I I I I I I
I I I I I I I I
I I I I I I I I
_1__4 _._F_-1__
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
-1--r--r-7-- --r --I--r--r-
I
I I I I I I I I
I I I I I I I I
I I I I
I 1 I I 1 I I I
I I• I I I I I I
I I I I I I I 1
1 I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
77034.008.01- FL WEST FORT PIERCE, FL (BU# 81381
Rountl FW
Feed Line Distribution Chart
0' - 250'
MPIn Face AWe Out Face - _ _. _ Truss Leg
W
Face A
---------------
________________
________
a
ffi
--
-
--
--
-
--
--
-
--
Ya
w'
w
w^
w
m
m
O
j
v
N
ri
F
( Face B
--
--
---
__
------
------
______
______
-----
-----
_____
____
------
------
______
------
--
---
__
__
?
m
^
�
U
Y 3
Face C
---------------
---- - - ---------L
---------------------- --
E
u
____W
_________
m
m
c
i
p5
V
B+T Gldrouite 300
p 77034.008.01- FL WEST FORT
1717 S. Bouer, SuPr?-
3•T G.v Tulsa, OK 74119 o"en` Crown Castle IDiawn trj Kiren
Phone: (918) 587-4630 CO4e' TIA-222-H oale:0123119
Nib
' tnxTower
d
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
1 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
%Clran
FAX..- (918) 295-0265
Tower Input Data
The main tower is a 3x free standing tower with an overall height of 250' above the ground line.
The base of the tower is set at an elevation of 0' above the ground line.
The face width of the tower is 6' at the top and 30' at the base.
This tower is designed using the TIA-222-H standard.
The following design criteria apply:
Tower base elevation above sea level: 19'.
Basic wind speed of 157 mph.
Risk Category H.
Exposure Category C.
Simplified Topographic Factor Procedure for wind speed-up calculations is used.
Topographic Category: 1.
Crest Height: 0'.
Deflections calculated using a wind speed of 60 mph.
TIA-222-H Annex S.
Pressures are calculated at each section.
Tower analysis based on target reliabilities in accordance with Annex S.
Load Modification Factors used: ICes(F,) = 0.95.
Stress ratio used in tower member design is 1.05.
Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered.
Consider Moments - Legs
Consider Moments - Horizontals
Consider Moments - Diagonals
Use Moment Magnification
Use Code Stress Ratios
Use Code Safety Factors - Guys
Escalate Ice
Always Use Max Kz
Use Special Wind Profile
Include Bolts In Member Capacity
Leg Bolts Are At Top Of Section
Secondary Horizontal Braces Leg
Use Diamond Inner Bracing (4 Sided)
SR Members Have Cut Ends
SR Members Are Concentric
Options
Distribute Leg Loads As Uniform
Assume Legs Pinned
Assume Rigid Index Plate
Use Clem Spans For Wind Area
Use Clear Spans For KL/r
Retension Guys To Initial Tension
Bypass Mast Stability Checks
Use Azimuth Dish Coefficients
Project Wind Area of Appurt.
Autocalc Torque Ann Areas
Add IBC .6D+W Combination
Sort Capacity Reports By Component
Triangulate Diamond Inner Bracing
Treat Feed Line Bundles As Cylinder
Ignore KL/ry For 60 Deg. Angle Legs
Use ASCE 10 X-Brace Ly Rules
J Calculate Redundant Bracing Forces
Ignore Redundant Members in FEA
4 SR Leg Bolts Resist Compression
All Leg Panels Have Same Allowable
Offset Girt At Foundation
J Consider Feed Line Torque
4 Include Angle Block Shear Check
Use TIA-222-H Bracing Resist. Exemption
Use TIA-222-H Tension Splice Exemption
I Poles I
Include Shear -Torsion Interaction
Always Use Sub -Critical Flow
Use Top Mounted Sockets
Pole Without Linear Attachments
Pole With Shroud Or No Appurtenances
Outside and Inside Comer Radii Are
Known
tnxTower
Job
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Project
B+T Group
1717 S. Boulder, Suite 300
Client
Tulsa, OK 74119
Phone: (918) 587-4630
Crown Castle
Wind 180
Lea A
Wind 90 QaoP e�
Leg C Z Leg B
Face C
Wind Normal
Triangular Tower
2 of 39 r
Date
14:12:19 01/23/19
Designed by
Kiran
Tower Tower Assembly Description Section Number Section
Section Elevation Database Width of Length
Sections
T1
250'-240'
6'
1
10,
12
240'-220' -
6'-
1
20,
T3
220'-200'
8'
1
20'
T4
200'-180'
10,
1
20'
T5
180'-160'
12'
1
20'
T6
160'-140'
14'
1
20'
T7
140'-120'
16'
1
20'
T8
120'-I00'
18,
1
20'
T9
100'-80'
20'
1
20'
T10
80'-60'
22'
1
20'
Tll
60'40'
24'
1
20'
TI2
40'-20'
26
1
20'
T13
20'-0'
28'
1
20'
Tower Section Geometry cont'd
Tower
Tower
Diagonal
Bracing
Has
Has
Top Girt
Bottom Girt
Section
Elevation
Spacing
Type
KBrace
Horizontals
Offset
Offset
End
ft
ft
Panels
in
in
Tl
250'-240'
5'
XBrace
No
No
0.000
0.000
T2
240'-220'
6'8"
X Brace
No
No
0.000
0.000
t MJob
xTower
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
3 of 39
B+T Group
Project
Date
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone., (918)587-4630
Crown Castle
Kiran
FAX.- (918) 295-0165
Tower
Tower
Diagonal
Bracing
Has
Has
Top Girt
Bottom Girt
Section
Elevation
Spacing
Type
KBrace
Horizontals
Offset
Offset
End
Jt
11
Panels
in
in
T3
220'-200'
6'8"
XBrace
No
No
0.000
0.000
T4
200'-180'
68"
XBrace
No
No
0.000
0.000
T5
180'-160'
5'
Double K
No
Yes
0.000
0.000
T6
160'-140'
5'
Double K
No
Yes
0.000
0.000
'17
140'-120'
5'
Double K
No
Yes
0.000
0.000
T8
120'-100'
5'
Double K
No
Yes
0.000
0.000
T9
100'-80'
5'
Double K
No
Yes
0.000
0.000
T10
80'-60'
10,
Double Kl
No
Yes
0.000
0.000
Tit
60'40'
10,
Double Kl
No
Yes
0.000
0.000
T12
40'-20'
to,
Double Kl
No
Yes
0.000
0.000
T13
20'-0'
10,
Double Kl
No
Yes
0.000
0.000
Tower Section Geometry cont'd
Tower
Leg
Leg
Leg
Diagonal
Diagonal
Diagonal
Elevation
ft
Type
Sue
Grade
Type
Size
Grade
Tl 250'-240'
Solid Round
2
A572-50
Equal Angle
L2x2x3/16
A36
(50 ksi)
(36 ksi)
T2 240'-220'
Solid Round
2 1/2
A572-50
Equal Angle
L2 1/2x2 1/2x3/16
A36
(50 ksi)
(36 ksi)
T3 220'-200'
Solid Round.
3
A572-50
Equal Angle
L2.1/2x2 1/20/16
A36
(50 ksi)
(36 ksi)
T4 200'-180'
Solid Round
3 1/4
A572-50
Equal Angle
L3x3x3/16
A36
(50 ksi)
(36 ksi)
T5180'-160'
Solid Round
31/4
A572-50
Double Angle
2L21/2x2120/16x3/8
A36
(50 ksi)
(36 ksi)
T6160'-140'
Solid Round
31/2
A572-50
Double Angle
2L212x2120/160/8
A36
(50 ksi)
(36 ksi)
T7 140'-120'
Solid Round
3 3/4
A572-50
Double Angle
2L2 12x2 12x3/16x3/8
A36
(50 ksi)
(36 ksi)
T8 120'-100'
Solid Round
4
A572-50
Double Angle
21,300/160/8
A36
(50 ksi)
(36 ksi)
T9100'-80'
Solid Round
4IA
A572-50
Double Angle
21,30x5/160/8
A36
(50 ksi)
(36 ksi)
T10 80'-60'
Solid Round
4 12
A572-50
Double Angle
21,300/160/8
A36
(50 ksi)
(36 ksi)
T11 60'-40'
Solid Round
4 3/4
A572-50
Double Angle
2L3x3x3/16x3/8
A36
(50 ksi)
(36 ksi)
T1240'-20'
Solid Round
43/4
A572-50
Double Angle
2L3x3xl/4x3/8
A36
(50 ksi)
(36 ksi)
T1320'-0'
Solid Round
5
A572-50
Double Angle
2L3x3xl/4x3/8
A36
(50 ksi)
(36 ksi)
Tower Section Geometry cont'd
Tower Top Girt
Top Girt
Top Girt Bottom Girt
Bottom Girt Bottom Girt
Elevation Type
ft
Site
Grade Type
Size Grade
T1250'-240' Single Angle
L2x2x3/16
A36 Flat Bar
A36
(36 ksi)
(36 ksi)
mxTower
Job
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
4 of 39 r
B+T Group
Project
Date
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Client
Designed by
Tulsa, OK 74119
Phone: (918) 5874630
Crown Castle
Kiran
FAX.- (918) 295-0265
Tower Section Geometry cont'd
Tower
No.
Mid Girt
Mid Girt Mid Girt
Horizontal
Horizontal
Horizontal
Elevation
of
Type
Size Grade
Type
Size
Grade
Mid
Jl
Girts
T5 I80'-160'
None
Flat Bar
A36
Equal Angle
L2x2x3/16
A36
(36 ksi)
(36 ksi)
T6160'-140'
None
Flat Bar
A36
Equal Angle
L212x212x3/16
A36
(36 ksi)
(36 ksi)
'17140'-120'
None
Flat Bar
A36
Equal Angle
L3x3x3/16
A36
(36 ksi)
(36 ksi)
T8120'-100'
None
Flat Bar
A36
Equal Angle
L3x3x3/16
A36
(36 ksi)
(36 ksi)
T9100'-80'
None
Flat Bar
A36
Equal Angle
L3x3xl/4
A36
(36 ksi)
(36 ksi)
T1080'-60'
None
Flat Bar
A36
Double Angle
2L2 1/2x2 1/2x3/16x3/8
A36
(36 ksi)
(36 ksi)
T1160'40'
None
Flat Bar
A36
Double Angle
2L212x212x3/16x3/8
A36
(36 ksi)
(36 ksi)
T1240'-20'
None
Flat Bar
A36
Double Angle
2L212x2120/160/8
A36
(36 ksi)
(36 ksi)
T1320'-0'
None
Flat Bar
A36
Double Angle
2L3x3x3/16x3/8
A36
(36 ksi)
(36 ksi)
Tower Section Geometry cont'd
Tower
Secondary Secondary Horizontal
Secondary
Inner Bracing
Inner Bracing Size
Inner Bracing
Elevation
Horizontal Type Sue
Horizontal
Type
Grade
Grade
T5 180'-160'
, Single Angle
A36
Equal Angle
L2x2x3/16
A36
(36 ksi)
(36 ksi)
T6160'-140'
Single Angle
A36
Equal Angle
L2x2x3/16
A36
(36 ksi)
(36 ksi)
T7140'-120'
Single Angle
A36
Equal Angle
L212x212x3/16
A36
(36 ksi)
(36 ksi)
T8120'-100'
Single Angle
A36
Equal Angle
L2 1/2x2 1/2x3/16
A36
(36 ksi)
(36 ksi)
T9100'-80'
Single Angle
A36
Equal Angle
L3x3x3/16
A36
(36 ksi)
(36 ksi)
T10 80'-60'
Single Angle
A36
Double Angle
2L2x2x3/16x3/8
A36
(36 ksi)
(36 ksi)
T1160'30'
Single Angle
A36
Double Angle
2L2x2x3/16x3/8
A36
(36 ksi)
(36 ksi)
T1240'-20'
Single Angle
A36
Double Angle
.2L212x21/20/160/8
A36
(36 ksi)
(36 ksi)
T13 20'-0'
Single Angle
A36
Double Angle
21,2 12x2 12x3/16x3/8
A36
(36 ksi)
(36 ksi)
' tnxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
5 of 39
Project
Date
B+T Group
1717S. Boulder, Suite300
14:12:19 01/23/19
Client
Designed by
Tulsa, OK 74119
Phone: (918) 587-4630
Crown Castle -
f(If2n
FAX.. (918) 295-0265
Tower Section Geometry cont'd
Tower Redundant Redundant Redundant KFactor
Elevation Bracing Type Size
Grade
(36 ksi)
Diagonal (1)
Double Angle
2L2x2x3/16x3/8
1
Hip (1)
Equal Angle
L2 1/2x2 1/2x3/16
1
T11 60'-40' A36
Horizontal (1)
Double Angle
2L2x2x3/16x3/8
l
(36 ksi)
Diagonal (1)
Double Angle
2L2x2x3/16x3/8
1
Hip (1)
Equal Angle
L2 1/2x2 1/2x3/16
1
T1240'-20' A36
Horizontal (1)
Double Angle
2L2x2x3/16x3/8
1
(36 ksi)
Diagonal (I)
Double Angle
2L2x2x3/16x3/8
1
Hip (1)
Equal Angle
L21/2x2120/16
1
T1320'-0' A36
Horizontal (1)
Double Angle
2L2x2x3/16x3/8
I
(36 ksi)
Diagonal (1)
Double Angle
2L2x2x3/16x3/8
I
Hip (1)
Equal Angle
L212x212x3/16
1
Tower Section Geometry cont'd
Tower
Gusset
Gusset
Gusset Grade Adjust. Factor
Adjust.
Weight Mult.
Double Angle Double Angle Double Angle
Elevation
Area
Thickness
Aj
Factor
Stitch Bolt
Stitch Bolt
Stitch Bolt
(perface)
A,
Spacing
Spacing
Spacing
Diagonals
Horizontals
Redundant,
R
liein
in
in
in
T1250'-240'
0.000
0.000
A36
1.05
1
1.05
Mid -Pt
Mid -Pt
Mid -Pt
(36 ksi)
T2 240'-220'
0.000
0.000
A36
1.05
1
1.05
Mid -Pt
Mid -Pt
Mid -Pt
(36 ksi)
T3 220'-200'
0.000
0.000
A36
1.05
1
1.05
Mid -Pt
Mid -Pt
Mid -Pt
(36 ksi)
T4200'-180'
0.000
0.000
A36
1.05
1
1.05
Mid -Pt
Mid -Pt
Mid -Pt
(36 ksi)
T5 180'-160'
0.000
0.000
A36
1.05
1
1.05
Mid -Pt
Mid -Pt
Mid -Pt
(36 ksi)
T6 160'-140'
0.000
0.000
A36
1.05
1
1.05
Mid -Pt
Mid -Pt
Mid -Pt
(36 ksi)
T7140'-120'
0.000
0.000
A36
1.05
1
1.05
Mid -Pt
Mid -Pt
Mid -Pt
(36 ksi)
T8 120'-100'
0.000
0.000
A36
1.05
1
1.05
Mid -Pt
Mid -Pt
Mid -Pt
(36 ksi)
T9100'-80,
0.000
0.000
A36
1.05
1
1.05
Mid -Pt
Mid -Pt
Mid -Pt.
(36 ksi)
T10 80'-60'
0.000
0.000
A36
1.05
1
1.05
46.140
Mid -Pt
Mid -Pt
(36 ksi)
T1160'40'
0.000
0.000
A36
1.05
1
1.05
48A60
Mid -Pt
Mid -Pt
(36 ksi)
TI240'-20'
0.000
0.000
A36
1.05
1
1.05
50.890
Mid -Pt
Mid -Pt
(36 ksi)
T13 20'-0'
0.000
0.000
A36
1.05
I
1.05
53.340
Mid -Pt
Mid -Pt
(36 ksi)
Tower Section Geometry cont'd
KFactors'
tnxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
6 of 39 .
B+T Group
Project
Date
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone. (918) 587-4630
Crown Castle
Klran
FAX: (918) 295-0265
Tower
Elevation
fit
Cale
K
Single
Angles
Cale
K
Solid
Rounds
Legs
X
Brace
Diags
X
Y
K
Brace
Diags
X
Y
Single
Diags
X
Y
Girts
X
Y
Hark.
X
Y
Sec.
Horiz.
X
Y
Inner
Brace
X
Y
T1250'-240'
Yes
Yes
1
1
1
1
1
1
I
1
1
1
1
l
1
I
1
T2 240'-220'
Yes
Yes
1
1
1
1
1
1
I
I
1
1
1
l
1
I
l
T3 220'-200'
Yes
Yes
1
1
1
1
l
1
I
I
1
1
1
1
I
I
l
T4200'-180'
Yes
Yes
1
1
1
1
1
1
I
l
1
1
1
1
1
I
l
T5180'-160'
Yes
Yes
11
1
1
1
1
1
1
I
1
1
I
1
1
I
l
T6160'-140'
Yes
Yes
1
1
1
I
1
1
1
I
1
1
1
1
I
1
1
T7140'-120'
Yes
Yes
1
I
1
I
1
I
I
1
1
1
1
1
I
I
1
T8120'-100'
Yes
Yes
1
1
1
I
1
1
I
1
1
1
I
1
1
I
1
T9100'-80,
Yes
Yes
1
l
1
I
1
I
1
1
l
I
I
1
I
1
1
T10 80'-60'
No
Yes
1
1
L
1
1
1
1
1
1
0.5
1
1
1
1
1
T1160'-40'
No.
Yes
I
1
1
1
I
1
1
1
1
0.5
1
1
1
1
1
T1240'-20'
No
Yes
I
1
1
1
1
1
1
I
1
0.5
1
1
1
1
I
T1320'-0'
No
Yes
1
1
1
1
1
1
1
1
1
0.5
1
1
1
1
I
'Note., Kfactors are applied to member segment lengths. K-braces without inner supporting members will have the Kfactor in the out -of --plane directi
the overall length
Tower Section Geometry conf'd
Tower
Elevation
n
Leg
Diagonal
Top Girt
Bottom Girt
Mid Girt
Long Horizontal
Short Horizontal
Net Width
U
Net Width
U
Net Width
U
Net
U
Net
U
Net
U
Net
U
Deduct
Deduct
Deduct
Width
Width
Width
Width
in
in
in
Deduct
Deduct
Deduct
Deduct
'
in
in
in
in
TI 250'-240'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T2 240'-220'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T3 220'-200'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T4 200'-180'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T5 180'-160'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T6 160'-140'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T7 140'-120'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T8 120'-100'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T9 100'-80'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
TIO 80'-60'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T11 60'40'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T12 40'-20'
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T13 20'-0'
1 0.000
1
1 0.000
0.75
1 0.000
0.75
1 0.000
0.75
1 0.000
0.75
1 0.000
0.75
1 0.000
0.75
r
tnxTower
ob
d 77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page 7 of 39
B+T Group
1717 S. Boulder, Suite 300
Project
Date
14:12:19 01 /23119
Tulsa, OK 74119
Phone., (918) 587-4630
FAX: (918) 295-0265
Client
Crown Castle
Designed by
Kiran
Tower Section Geometry cont'd
Tower
Elevation
ft
Leg
Connection
Type
Leg
Bolt Size
No.
Diagonal
Top Girt
Bottom Girt
Mid Girt
Long Horizontal
Short Horizontal
Bolt Size No.
Bolt Size Na
Bolt Size No.
Bolt Size No.
Bolt Size No.
Bolt Size
No..
in
in
in
in
in
in
in
T1 250'-240'
Flange
0.625
4
0.625
2
0.625
1
0.000
0
0.625
0
0.000
0-
0.625
0
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T2 240'-220'
Flange
0.625
6
0.625
2
0.000
0
0.000
0
0.625
0
0.000
0
0.625
0
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T3 220'-200'
Flange
0.875
6
0.625
2
0.000
0
0.000
0
0.625
0
0.000
0
0.625
0
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T4 200'-180'
Flange
1.000
6
0.625
2
0.000
0
0.000
0
0.625
0
0.000
0
0.625
0
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T5 180'-160'
Flange
1.000
6
0.625
2
0.000
0
0.000
0
0.625
0
0.625
1
0.625
1
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T6 160'-140'
Flange
1.000
6
0.625
2
0.000
0
0.000
0
0.625
0
0.625
1
0.625
1
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T7 140'-120'
Flange
1.125
6
0.625
2
0.000
0
0.000
0
0.625
0
0.625
1
0.625
1
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T8 120'-100'
Flange
1.250
6
0,625
2
0.000
0
0.000
0
0.625
0
0.625
1
0.625
1
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T9 100'-80,
Flange
1.250
6
0.625
2
0.000
0
0.000
0
0.625
0
0.625
I
0.625
1
A325N
A325X
A325N
A325N
A325N
A325N
A325N
TIO 80'-60'
Flange
1.375
6
0.625
2
0.000
0
0.000
0
0.625
0
0.625
1
0.625
I
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T11 60'-40'
Flange .
1.500
6
0.625
2
0.000
0
0.000
0
0.625
0
0.625
10.625
I
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T1240'-20'
Flange
1.500
6
0.625
2
0.000
0
0.000
0
0.625
0
0.625
I
0.625
I
A325N
A325N
A325N
A325N
A325N
A325N
A325N
T13 20'-0'
Flange
2.250
0
0.625
2
0.000
0
0.000
0
0.625
0
0.625
I
0.625
I
A36
A325N
A325N
A325N
A325N
I A325N
A325N
Feed Line/Linear Appurtenances - Entered As Round Or Flat
Description Face Allow Exclude Component Placement Face Lateral # 4 Clear Width or Perimeter Weight
or Shield From Type Offset Offset Per Spacing Diameter
Leg Torque ft in (Frac FW) Row in in in ldf
Calculation
LDF7-50A(1- B No
5/8)
(E)
Feedline B No
Ladder(At)
(E)
s*K--
LCF158-50J(1 A No
-5/8)
(E)
LCF158-50J(1 A No
-5/8)
(E)
LCF158-50J(1 A No
-5/8)
(E)
LCF158-50J(1 A No
No
At (CaAa)
243' - 0'
0.000
0.4
13
7
0.850
1.980
0.750
No
Af (CaAa)
243' - 0'
0.000
0.4
1
1
3.000
3.000
No
At (CaAa)
143' - 0'
0.000
-0.45
2
2
0.850
2.010
0.750
No
At (CaAa)
143' - 0'
0.000
-0.4
5
4
0.850
2.010
0.750
No
Ar (CaAa)
143' - 0'
0.000
-0.36
3
1
0.850
2.010
0.750
No
At (CaAa)
143' - 0'
0.000
-0.34
2
2
0.850
2.010
0.001
0.008
0.001
0.001
0.001
0.001
tnxTower
Job
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
8 of 39
Project
Date
j3+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Client
Designed by
Tulsa, 0K74119
Phone: (918) 5874630
Crown Castle
Kiran
FAX (918) 295-0265
Description Face Allow Exclude Component Placement Face Lateral # 4 Clear Width or Perimeter Weight
or Shield From Type Q$set Offset Per Spacing Diameter
Leg Torque ft in (Frac FW) Row in in in k!f
WR-VG86ST-
A
No
No
At (CaAa)
143'-0'
0.000
-0.32
6
4
0.850
0.795
0.001
BRD(3/4)
0.750
(2E+4P)
FB-L98B-034-
A
No
No
Ar (CaAa)
143' - 0'
3.000
-0.32
4
4
0.850
0.394
0.000
XXX(3/8)
0.750
(3P+1P(5/16))
Feedline
A
No
No
Af (CaAa)
250' - 0'
0.000
-0.38
1
1
3.000
3.000
0.008
Ladder (At)
(E)
•rKtr
TSZ 999
A
No
No
At (CaAa)
130'- 0'
0.000
0.4
3
2
0.850
1.039
0.001
066/.XXXA4-8
0.750
AWG(1-1/32)
FIBER ONLY
A
No
No
Ar (CaAa)
130' - 0'
0.000
0.39
1
1
0.850
0.867
0.000
CABLE
0.750
48(7/8)
(E)
Feedline
A
No
No
Af (CaAa)
130' - 0'
0.000
0.42
1
1
3.000
3.000
0.008
Ladder (At)
'
(E)
•rK**
Climbing
B
No
No
Af (CaAa)
250' - 0'
0.000
0
1
1
3.840
3.840
0.005
Ladder ( Flat)
(E)
Safety Line
B
No
No
Ar (CaAa)
250' - 0'
0.000
0
1
1
0.375
0.375
0.000
3/8
(E)
RtK**
Feedline
C
No
No
At (CaAa)
145' - 0'
0.000
-0.4
1
1
3.000
3.000
0.008
Ladder (At)
(Empty)
Feedline
C
No
No
At (CaAa)
145'-0'
0.000
-0.425
1
1
3.000
3.000
0.008
Ladder (At)
(Empty)
ssK**
Light Chord
C
No
No
At (CaAa)
125' - 0'
0.000
0.5
2
2
0.500
0.630
0.000
(E)
Light Chord
C
No
No
At (CaAa)
250' - 125'
0.000
0.5
1
1
0.500
0.630
0.000
(E)
ssKia
Feed Line/Linear Appurtenances - Entered As Area
Description Face Allow Exclude Component Placement Total CAAA Weight
or Shield From Type Number
Leg Torque ft fr=/ft klf
Calculation
♦sKsa
tnxTower
Job
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
9 of 39
Project
Date
14:12:19 01 /23/19
B+T Group
1717 S. Boulder, Suite 300
Tulsa, OK 74119
Phone: (918) 5874630
FAX. (918) 295-0165
Client
Crown Castle
Designed by
Kiran
Feed Line/Linear Appurtenances Section Areas
Tower
Tower
Face
AR
AF
CAAA
CAAA
Weight
Section
Elevation
In Face
Out Face
ft
ft:
fP
fJY
it,
K
Tl
250'-240'
A
0.000
0.000
5.000
0.000
0.084
B
0.000
0.000
15.997
0.000
0.107
C
0.000
0.000
0.630
0.000
0.002
T2
240'-220'
A
0.000
0.000
10.000
0.000
0.168
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
1.260
0.000
0.003
73
220'-200'
A
0.000
0.000
10.000
' 0.000
0.168
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
1.260
0.000
0.003
T4
200'-180'
A
0.000
0.000
10.000
0.000
0.168
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
1.260
0.000
0.003
T5
180'-160'
A
0.000
0.000
10.000
0.000
0.168
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
1.260
0.000
0.003
T6
160'-140'
A
0.000
0.000
19.139
0.000
0.212
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
6.260
0.000
0.087
T7
140'-120'
A
0.000
0.000
79.914
0.000
0.571
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
21.575
0.000
0.340
T8
120'-100,
A
0.000
0.000
88.898
0.000
0.679
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
22.520
0.000
0.342
T9
100'-90,
A
0.000
0.000
88.898
0.000
0.679
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
22.520
0.000
0.342
T10
80'-60'
A
0.000
0.000
88.898
0.000
0.679
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
22.520
0.000
0.342
T11
60'40'
A
0.000
0.000
88.898
0.000
0.679
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
22.520
0.000
0.342
T12
40'-20'
A
0.000
0.000
88.898
0.000
0.679
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
22.520
0.000
0.342
T13
20'-0'
A
0.000
0.000
88.898
0.000
0.679
B
0.000
0.000
75.030
0.000
0.482
C
0.000
0.000
22.520
0.000
0.342
Feed Line Center of Pressure
Section
Elevation
CPx
Cps
CPx
CPe
Ice
ice
11
in
in
in
in
TI
250'-240'
1.935
1.902
1.935
1.902
72
240'-220'
7.981
5.424
7.970
5.417
T3
220'-200'
9.149
6.532
9.042
6.459
T4
200'-180'
9.321
7.002
9.186
6.902
T5
180'-160'
11.094
8.428
10.923
8.301
T6
160'-140'
8.876
10.922
8.717
10.728'
T7
140'-120'
-4.476
14.315
4.404
14.087
T8
120'-100'
-4.982
11.657
4.897
11.458
T9
100'-80'
-5.225
12.385
-5.124
12.142
tnxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
10 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23119
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX.' (918) 295-0165
Section
Elevation
CPx
CPz
CPx
CPz
Ice
Ice
JT
in
in
in ,
in
T10
80'-60'
-6.055
14.293
-5.902
13.932
T11
60'-40'
-6.338
15.097
-6.166
14.685
T12
40'-20'
-6.596
15.842
-6.444
15.471
T13
20'-0'
-6.711
16.272
-6.565
15.911
Shielding Factor Ka
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment Elev.
Kv
No Ice
Kv
Ice
Tl
2
LDF7-50A(1-5/8)
240.00-
0.6000
0.6000
243.00
T1
4
Feedline Ladder(Af)
240.00-
0.6000
0.6000
243.00
T1
16
Feedline Ladder (All
240.00-
0.6000
0.6000
250.00
T1
22
Climbing Ladder (Flat)
240.00-
0.6000
0.6000
250.00
T1
23
Safety Line 318
240.00-
0.6000
0.6000
250.00
Tl
29
Light Chord
240.00-
0.6000
0.6000
250.00
T2
2
• LDF7-50A(1-5/8)
220.00-
0.6000
6.6000
240.00
T2
4
Feedline Ladder(Af)
220.00-
0.6000
0.6000
240.00
T2
16
Feedline Ladder (Al)
220.00-
0.6000
0.6000
240.00
72
22
Climbing Ladder ( Flat)
220.00-
0.6000
0.6000
240.00
T2
23
Safety Line 3/8
220.00-
0.6000
0.6000
240.00
T2
29
Light Chord
220.00-
0.6000
0.6000
240.00
T3
2
LDF7-50A(1-5/8)
200.00-
0.6000
0.6000
220.00
T3
4
Feedline Ladder(Af)
200.00-
0.6000
0.6000
220.00
T3
16
Feedline Ladder (At)
200.00-
0.6000
0.6000
220.00
T3
22
Climbing Ladder (Flat)
200.00-
0.6000
0.6000
220.00
T3
23
Safety Line 3/8
200.00-
0.6000
0.6000
220.00
T3
29
Light Chard
200.00-
0.6000
0.6000
220.00
T4
2
LDF7-50A(1-5/8)
180.00-
0.6000
0.6000
200.00
T4
4
Feedline Ladder (Al)
180.00 -
0.6000
0.6000
200.00
Ti
16
Feedline Ladder (Al)
180.00 -
0.6000
0.6000
200.00
T4
22
Climbing Ladder ( Flat)
180.00 -
0.6000
0.6000
200.00
T4
23
Safety Line 3/8
180.00 -
0.6000
0.6000
200.00
MxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
11 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK74119
Client
Designed by
Phone: (918) 5874630
Crown Castle
Kiran
FAX: (918) 295-0265
Traver
Section
Feed Line
BecordNo.
Description
Feed Line
Segment El".
K.
No Ice
K.
Ice
T4
29
Light Chord
180.00-
0.6000
0.6000
200.00
TS
2
LDF7-50A(1-5/8)
160.00-
0.6000
0.6000
180.00
T5
4
Feedline Ladder (At)
160.00-
0.6000
0.6000
180.00
T5
16
Feedline Ladder (At)
160.00-
0.6000
0.6000
180.00
T5
22
Climbing Ladder ( Flat)
160.00-
0.6000
0.6000
180.00
T5
23
Safety Line 318
160.00-
0.6000
0.6000
180.00
T5
29
Light Chord
160.00-
0.6000
0.6000
180.00
T6
2
LDF7-50A(1-5/8)
140.00-
0.6000
0.6000
160.00
T6
4
Feedline Ladder (At)
140.00-
0.6000
0.6000
160.00
T6
6
LCF158-50J(1-5/8)
140.00-
0.6000
0.6000
143.00
T6
7
LCF158-50J(1-5/8)
140.00-
0.6000
0.6000
143.00
T6
8
LCF158-SOJ(1-5/8)
140.00-
0.6000
0.6000
143.00
T6
9
LCF158-50J(1-5/8)
140.00-
0.6000
0.6000
143.00
T6
10
WR-VG86ST-BRD(3/4)
140.00-
0.6000
0.6000
143.00
T6
14
FB-L98B-034-XXX(3/8)
140.00-
0.6000
0.6000
143.00
T6
16
Feedline Ladder (Af)
140.00-
0.6000
0.6000
160.00
T6
22
Climbing Ladder ( Flat)
140.00-
0.6000
0.6000
160.00
T6
23
Safety Line 3/8
140.00-
0.6000
0.6000
160.00
T6
25
Feedline Ladder (At)
140.00-
0.6000
0.6000
145.00
T6
26
Feedline Ladder (At)
140.00-
0.6000
0.6000
145.00
T6
29
Light Chord
140.00-
0.6000
0.6000
160.00
T7
2
LDF7-50A(1-5/8)
120.00-
0.6000
0.6000
140.00
T7
4
Feedline Ladder (At)
120.00-
0.6000
0.6000
140.00
T7
6
LCF158-50J(1-5/8)
120.00-
0.6000
0.60,00
140.00
17
7
LCF158-SOJ(1-58)
120.00-
0.6000
0.6000
140.00
T7
8
LCF158-50J(1-5/8)
120.00-
0.6000
0.6000
140.00
T7
9
LCF158-50J(1-5/8)
120.00-
0.6000
0.6000
140.00
17
10
WR-VG86ST-BRD(3/4)
120.00-
0.6000
0.6000
140.00
T7
14
FB-L98B-034-XXX(3/8)
120.00-
0.6000
0.6000
140.00
T7
16
Feedline Ladder (At)
120.00-1
0.60001
0.6000
140.00
T7
18
TSZ 999
120.00 -
0.6000
0.6000
066/)
130.00
'
tnxTower
Job
Page
1
77034.008.0.1 - FL WEST FORT PIERCE, FL (BU# 813812)
12 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone. (918) 5874630
Crown Castle
Kiran
FAX.- (918) 295-0265
Tower
Section
Feed Line
Record No.
Description
Feed Line
SegmentElev.
K.
No Ice
K.
Ice
T7
19
FIBER ONLY CABLE
120.00-
0.6000
0.6000
48(7/8)
130.00
17
20
Feedline Ladder (At)
120.00-
0.6000
0.6000
130.00
T7
22
Climbing Ladder ( Flat)
120.00-
0.6000
0.6000
140.00
T7
23
Safety Line 3/8
120.00-
0.6000
0.6000
140.00
T7
25
Feedline Ladder (At)
120.00-
0.6000
0.6000
140.00
T7
26
Feedline Ladder (Ali
120.00-
0.6000
0.6000
140.00
T7
28
Light Chord
120.00-
0.6000
0.6000
125.00
T7
29
Light Chord
125.00 -
0.6000
0.6000
140.00
T8
2
LDF7-50A(1-5/8)
100.00-
0.6000
0.6000
120.00
T8
4
Feedline Ladder (At)
100.00-
0.6000
0.6000
120.00
T8
6
LCF158-50J(1-5/8)
100.00-
0.6000
0.6000
120.00
T8
7
LCF158-50J(1-5/8)
100.00-
M000
0.6000
120.00
T8
8
LCF158-50J(1-5/8)
100.00-
0.6000
0.6000
120.00
T8
9
LCF158-50J(1-5/8)
100.00-
0.6000
0.6000
120.00
T8
10
WR-VG86ST-BRD(3/4)
100.00-
0.6000
0.6000
120.00
T8
14
FB-L98B-034-XXX(3/8)
100.00-
0.6000
0.6000
120.00
T8
16
Feedline Ladder(Af)
100.00-
0.6000
0.6000
120.00
T8
18
TSZ 999
100.00-
0.6000
0.6000
066/X7CGt4-8AWG(1-l/32)
120.00
T8
19
FIBER ONLY CABLE
100.00-
0.6000
0.6000
48(7/8)
120.00
T8
20
Feedline Ladder(At)
100.00-
0.6000
0.6000
120.00
T8
22
Climbing Ladder ( Flat)
100.00-
0.6000
0.6000
120.00
T8
23
Safety Line 3/8
100.00-
0.6000
0.6000
120.00
T8
25
Feedline Ladder (At)
100.00-
0.6000
0.6000
120:00
T8
26
Feedline Ladder (An
100.00-
0.6000
0.6000
120.00
T8
28
Light Chord
100.00-
0.6000
0.6000
120.00
T9
2
LDF7-50A(1-5/8)
80.00 - 100.00
0.6000
0.6000
T9
4
Feedline Ladder (Af)
80.00 - 100.00
0.6000
0.6000
T9
6
LCF158-50J(1-5/8)
80.00 - 100.00
0.6000
0.6000
T9
7
LCF158-50J(1-5/8)
80.00 - 100.00
0.6000
0.6000
T9
8
LCF158-50J(1-5/8)
80.00-100.00
0.6000
0.6000
T9
9
LCF158-50J(1-5/8)
MOO-100.00
0.6000
0.6000
T9
10
WR-VG86ST-BRD(3/4)
80.00-100.00
0.6000
0.6000
T9
14
FB-L98B-034-XXX(3/8)
80.00-100.00
0.6000
0.6000
T9
16
Feedline Ladder(Af)
80.00-100.00
0.6000
0.6000
T9
18
TSZ 999
80.00-100.00
0.6000
0.6000
066/,ND0C 4-8AWG(1-1/32)
T9
19
FIBER ONLY CABLE
80.00 - 100.00
0.6000
0.6000
b-
t% x oweN
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
13 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX (918)295-0265
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment Elev.
K
No Ice
&
Ice
48(7/8)
T9
20
Feedline Ladder (At)
80.00- 100.00
0.6000
0.6000
T9
22
Climbing Ladder ( Flat)
80.00 - 100.00
0.6000
0.6000
T9
23
Safety Line 3/8
90.00- 100.00
0.6000
0.6000
T9
25
Feedline Ladder (At)
80.00 - 100.00
0.6000
0.6000
T9
26
Feedline Ladder (At)
90.00 - 100.00
0.6000
0.6000
T9
28
Light Chord
80.00 - I00.00
0.6000
0.6000
T10
2
LDF7-50A(1-5/8)
60.00-80.00
0.6000
0.6000
T10
4
Feedline Ladder (Af)
60.00 - 80.00
0.6000
0.6000
T10
6
LCF158-50J(1-5/8)
60.00-80.00
0.6000
0.6000
T10
7
LCFI58-50J(1-5/8)
60.00-80.00
0.6000
0.6000
T10
8
LCF158-50J(1-5/8)
60.00-80.00
0.6000
0.6000
T10
9
LCF158-50J(1-5/8)
60.00-80.00
0.6000
0.6000
T10
10
WR-VG86ST-BRD(3/4)
60.00-80.00
0.6000
0.6000
T10
14
FB-L98B-034-XXX(3/8)
60.00- 80.00
0.6000
0.6000
T10
16
Feedline Ladder (At)
60.00 - 90.00
0.6000
0.6000
TIO
18
TSZ 999
60.00 - 80.00
0.6000
0.6000
066/XXXM-8AWG(1-1132)
TI O
19
FIBER ONLY CABLE
60.00 - 80.00
0.6000
0.6000
48(7/8)
T10
20
Feedline Ladder (At)
60.00 - 80.00
0.6000
0.6000
Tl0
22
Climbing Ladder ( Flat)
60.00 - 80.00
0.6000
0.6000
TI O
23
Safety Line 3/8
60.00 - 80.00
0.6000
0.6000
T10
25
Feedline Ladder (At)
60.00 - 80.00
0.6000
0.6000
T10
26
Feedline Ladder (Af)
60.00 - 80.00
0.6000
0.6000
T10
28
Light Chord
60.00 -80.00
0.6000
0.6000
Tit
2
LDF7-50A(1-5/8)
40.00 - 60.00
0.6000
0.6000
Tl1
4
Feedline Ladder (Af)
40.00 - 60.00
0.6000
0.6000
Tit
6
LCFI58-50J(1-5/8)
40.00-60.00
0.6000
0.6000
Tit
7
LCF158-50J(1-5/8)
40.00-60.00
0.6000
0.6000
Tit
8
LCF158-50J(1-5/8)
40.00-60.00
0.6000
0.6000
Tit
9
LCF158-50J(1-5/8)
40.00-60.00
0.6000
0.6000
Tit
10
WR-VG86ST-BRD(3/4)
40.00-60.00
0.6000
0.6000
Tit
14
FB-L98B-034-XXX(3/8)
40.00-60.00
0.6000
0.6000
Tit
16
Feedline Ladder (At)
40.00 - 60.00
0.6000
0.6000
Tit
18
TSZ 999
40.00 - 60.00
0.6000
0.6000
066/XXXM-8AWG(1-1/32)
Tl l
19
F113ER ONLY CABLE
40.00 - 60.00
0.6000
0.6000
48(7/8)
Tl1
20
Feedline Ladder (At)
40.00 - 60.00
0.6000
0.6000
Tl l
22
Climbing Ladder ( Flat)
40.00 - 60.00
0.6000
0.6000
Tl I
23
Safety Line 3/8
40.00 - 60.00
0.6000
0.6000
Tl l
25
Feedline Ladder (Ai)
40.00 - 60.00
0.6000
0.6000
Tl I
26
Feedline Ladder (Af)
40.00 - 60.00
0.6000
0.6000
T11
28
Light Chord
40.00 -60.00
0.6000
0.6000
T12
2
LDF7-50A(1-5/8)
20.00-40.00
0.6000
0.6000
T12
4
Feedline Ladder (Af)
20.00-40.00
0.6000
0.6000
T12
6
LCFI58-50J(1-5/8)
20.00-40.00
0.6000
0.6000
T12
7
LCFI58-50J(1-5/8)
20.00-40.00
0.6000
0.6000
T12
8
LCFI58.50J(1-5/8)
20.00-40.00
0.6000
0.6000
T12
9
LCFI58-50J(1-5/8)
20.00-40.00
0.6000
0.6000
T12
10
WR-VG86ST-BRD(3/4)
20.00-40.00
0.6000
0.6000
T12
14
FB-L98B-034-XXX(3/8)
20.00-40.00
0.6000
0.6000
T12
16
Feedline Ladder (At)
20.00 - 40.00
0.6000
0.6000
T12
18
TSZ 999
20.00-40.00
0.6000
0.6000
066/XXXM-8A WG(1-1/32)
T12
19
FIBER ONLY CABLE
20.00 - 40.00
0.6000
0.6000
48(7/8)
T12
20
Feedline Ladder (At)
20.00 - 40.00
0.60001
0.6000
T12
22
Climbing Ladder (Flat)
20.00 - 40.00
0.60001
0.6000
T12
23
Safety Line 3/8
20.00 - 40.00
0.60001
0.6000
T12
25
Feedline Ladder (Af)
20.00 - 40.001
0.60001
0.6000
tnxTower
Job
Page
'
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
14 of 39
B+T Grotip
Project
Date
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Client
Designed by
Tulsa, OK 74119
Phone: (918)587-4630
Crown Castle
Kiran
FAX (918) 295-0265
Tower
Section
Feed Line
Record No.
Description
Feed Line
Segment Elev.
K.
No Ice
K.
Ice
T12
26
Feedline Ladder (Al)
20.00 - 40.00
0.6000
0.6000
T12
28
Light Chord
20.00-40.00
0.6000
0.6000
T13
2
LDF7-50A(1-5/8)
0.00-20.00
0.6000
0.6000
T13
4
Feedline Ladder (Ai)
0.00 - 20.00
0.6000
0.6000
T13
6
LCF158-50J(1-5/8)
0.00-20.00
0.6000
0.6000
T13
7
LCF158-50J(1-5/8)
0.00-20.00
_ 0.6000
0.6000
T13
8
LCF158-50J(1-5/8)
0.00 -20.00
0,6000
0.6000
T13
9
LCF158-50J(1-5/8)
0.00 -20.00
0.6000
0.6000
T13
10
WR-VG86ST-BRD(3/4)
0.00-20.00
0.6000
0.6000
T13
14
FB-L98B-034-XXX(3/8)
0.00-20.00
0.6000
0.6000
T13
16
Feedline Ladder(Af)
0.00-20.00
0.6000
0.6000
T13
18
TSZ 999
0.00-20.00
0.6000
0.6000
066/XRXM-8AW G(I-1/32)
T13
19
FIBER ONLY CABLE
0.00 - 20.00
0.6000
0.6000
48(7/8)
T13
20
Feedline Ladder (At)
0.00 - 20.00
0.6000
0.6000
T13
22
Climbing Ladder ( Flat)
0.00 - 20.00
0.6000
0.6000
T13
23
Safety Line 3/81
0.00 - 20.00
0.6000
0.6001
T13
25
Feedline Ladder (A0
0.00 - 20.00
0.6000
0.6000
T13
26
Feedline Ladder (Af)
0.00 - 20.00
0.6000
0.6000
T131
28
LightChordl
0.00 - 20.00
0.6000
0.6000
Discrete Tower Loads
Description
Face
Offset
Offsets:
Azimuth
Placement
CAAA
CAAA
Weight
or
Type
Hom
Adjustment
Front
Side
Leg
Lateral
Vert
it
op
ft'
ft'
K
n
R
Flash Beacon Lighting
C
From Leg
0.000
0.000
249'6"
No Ice
2.700
2.700
0.050
(E)
0'
1'
Side Lighting
A
From Leg
0.500
0.000
125'
No Ice
0.133
0.133
0.005
(E)
0'
0'
Side Lighting
B
From Leg
0.500
0.000
125'
No Ice
0.133
0.133
0.005
(E)
0'
0'
Side Lighting
C
From Leg
0.500
0.000
125'
No Ice
0.133
0.133
0.005
(E)
0'
0'
"K"
4' Dipole
B
From Leg
1.000
0.000
234'
No Ice
1.393
1.393
0.035
(E-PER PHOTO AND TIA)
0'
0'
4' Dipole
A
From Leg
1.000
0.000
215'
No Ice
1.393
1.393
0.035
(E-PER PHOTO AND TIA)
0'
0'
4' Dipole
B
From Leg
1.000
0.000
191,
No Ice
1.393
1.393
0.035
(E-PER PHOTO AND TIA)
0'
0'
4' Dipole
A
From Leg
1.000
0.000
177'
No Ice
1.393
1.393
0.035
(E-PER PHOTO AND TIA)
0'
tnxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
15 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX (918) 295-0265
Description
Face
Offset
Offsets:
Azimuth
Placement
CAA.
CAAA
Weight
or
Type
Hors
Adjustment
Front
Side
Leg
Lateral
Vert
ft
ft
fF
ftr
K
R
R
0'
(2)X7CQAP-665-VRO
A
From Leg
4.000
0.000
243'
No Ice
9.549
5.458
0.045
(E)
0'
(2)X7CQAP-665-VRO
13
From Leg
1'
4.000
0.000
243'
No Ice
9.549
5.458
0.045
(E)
0'
1'
(2)X7CQAP-665-VRO
C
From Leg
4.000
0.000
243'
No Ice
9.549
5.458
0.045
(E)
0,
1'
(2) E15R05P19
A
From Leg
4.000
0.000
243'
No Ice
0.941
0.608
0.023
(E)
0'
1'
(2) E15R05PI9
B
From Leg
4.000
0.000
243'
No Ice
0.941
0.608
0.023
(E)
0,
1'
(2) E15R05PI9
C
From Leg
4.000
0.000
243'
No Ice
0.941
0.608
0.023
(E)
0'
1'
RRUS12/RRUSA2
A
From Leg
4.000
0.000
243'
No Ice
3.143
1.835
0.072
(E)
0'
1'
RRUS12/RRUS A2
B
From Leg
4.000
0.000
243'
No Ice
3.143
1.835
0.072
(E)
0'
1'
RRUS12/RRUS A2
C
From Leg
4.000
0.000
243'
No Ice
3.143
1.835
0.072
(E)
0'
l'
(2) DBC-7CAP
A
From Leg
4.000
0.000
243'
No Ice
0.613
0.116
0.007
(E)
0'
0'
(2) DBC-7CAP
B
From Leg
4.000
0.000
243'
No Ice
0.613
0.116
0.007
(E)
0'
0'
(2) DBC-7CAP
C
From Leg
4.000
0.000
243'
No Ice
0.613
0.116
0.007
(E)
0'
0'
RXXDC-3315-PF-48
B
From Leg
4.000
0.000
243'
No Ice
3.708
2.192
0.032
(E)
0'
1'
6' is 2" Mount Pipe
A
From Leg
4.000
0.000
243'
No Ice
1A25
1.425
0.022
(E)
0'
0'
6' x 2" Mount Pipe
B
From Leg
4.000
0.000
243'
No Ice
1.425
1A25
0.022
(E)
0'
o'
6' x 2" Mount Pipe
C
From Leg
4.000
0.000
243'
No Ice
1.425
LA25
0.022
(E)
0'
0'
Sector Mount ISM 402-3]
(E-2MP Per Sec)
•�X*r
DC6-48-60-18-8F
(E)
(3) SBNHH-ID85B w/
C None
A From Leg 4.000
0'
3'
A From Leg 4.000
0.000
243'
No Ice
18.910
18.910
0.851
0.000
143'
No Ice
0.917
0.917
0.019
0.000
143'
No Ice
8.316
7.004
0.070
� r i
tnxTower
Job
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
16 of 39 '
B+T Group
Project
Date
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Client
Designed by
Tulsa, OK 74119
Phone: (918)587-4630
Crown Castle
Kiran
FAX.' (918) 295-0265
Description
Face
Offset
Offsets:
Azimuth
Placement
CAAA
CAAA
Weight
or
Type
Horz
Adjustment
Front
Side
Leg
Lateral
Vert
ft
f1
ft'
fl=
K
f1
ft
Mount Pipe
0'
(P)
3'
(3) SBNHH-1D85B w/
C
From Leg
4.000
0.000
143'
No Ice
8.316
7.004
0.070
Mount Pipe
0'
(P)
3'
(2)
B
From Leg
4.000
0.000
143'
No Ice
8.371
6.537
0.069
ET-X-UW-68-14-65-18-IIL-A
0'
T w/ Mount Pipe
3'
(P)
80010965K w/ Mount Pipe
B
From Leg
4.000
0.000
143'
No Ice
14.051
7.628
0.125
(P)
0'
3'
RRUS 32
A
From Leg
4.000
0.000
143'
No Ice
2.857
1.777
0.055
(P)
0'
3'
RRUS 32
B
From Leg
4.000
0.000
143'
No Ice
2.857
1.777
0.055
(P)
0'
3'
RRUS 32
C
From Leg
4.000
0.000
143'
No Ice
2.857
1.777
0.055
(P)
0'
3'
RRUS 4449 135B12
A
From Leg
4.000
0.000
143'
No Ice
1.968
1.408
0.071
(P)
0'
3'
.
RRUS 4449 135/1312
B
From Leg
4.000
0.000
143'
No Ice
1.968
1.408
0.071
(P)
0'
3'
RRUS 4449 135B12
C
From Leg
4.000
0.000
143'
No Ice
1.968
IA08
0.071
(P)
0'
3'
RRUS 8843 132B66A
A
From Leg
4.000
0.000
143'
No Ice
1.639
1.353
0.072
(P)
0'
3'
RRUS 8843 132/1366A
B
From Leg
4.000
0.000
143'
No Ice
1.639
1.353
0.072
(P)
0'
3'
RRUS 8843 132/1366A
C
From Leg
4.000
0.000
143'
No Ice
1.639
1.353
0.072
(P)
0'
3'
DC6-48-60-18-8C
B
From Leg
4.000
0.000
143'
No Ice
2.737
2.737
0.026
(P)
0'
3'
DC6-48-60-18-8C
C
From Leg
4.000
0.000
143'
No Ice
2.737
2.737
0.026
(P)
0'
3'
Sector Mount ISM 502-31
C
None
0.000
143'
No Ice
33.020
33.020
1.673
(E)
w�Kt.
TTTT65AP-IXRw/Mount
A
From Leg
4.000
0.000
130'
No Ice
7.218
4.777
0.056
Pipe
0'
(E)
T
=65AP-1XRw/Mount
B
From Leg
4.000
0.000
130'
No Ice
7.218
4.777
0.056
Pipe
0'
(E)
2'
TTTT65AP-lXR w/ Mount
C
From Leg
4.000
0.000
130'
No Ice
7218
4.777
0.056
Pipe
0'
(E)
2'
I)Z.. Tower
J
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
17 of 39
Project
Date
B+T Group
1717S. Boulder, Suite 300
14:12:19 01/23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX (918) 295-0265
Description
Face
Offset
Offsets:
Azimuth
Placement
CAAA
CAAA
Weight
or
Type
Harz
Adjustment
Front
Side
Leg
Lateral
Vert
ft
ft
fi2
f+t
K
ft
R
APXVSPP l8-C w/ Mount
A
From Leg
4.000
0.000
130'
No Ice
8.262
6.946
0.083
Pipe
0'
(E)
2'
APXVSPPI8-Cw/Mount
B
From Leg
4.000
0.000
130'
No Ice
8.262
6.946
0.083
Pipe
0'
(E)
2'
APXVSPP19-C w/ Mount
C
From Leg
4.000
0.000
130'
No Ice
8.262
6.946
0.083
Pipe
0'
(E)
2'
RRUS 31 B25
A
From Leg
4.000
0.000
130'
No Ice
1.623
1.279
0.056
(E)
0'
0'
RRUS 31 B25
B
From Leg
4.000
0.000
130'
No Ice
1.623
1.279
0.056
(E)
0'
0'
RRUS 31 B25
C
From Leg
4.000
0.000
130'
No Ice
1.623
1.279
0.056
(E)
0'
0'
FZHJ-RRH
A
From Leg
4.000
0.000
130'
No Ice
1.262
1.015
0.055
(E)
0'
I'
FZHJ-RRH
B
From Leg
4.000
0.000
130'
No Ice
1.262
1.015
0.055
(E)
0'
1'
FZHJ-RRH
C
From Leg
4.000
0.000
130'
No Ice
1.262
1.015
0.055
(E)
0'
1'
(3) ACU-A20-N
A
From Leg
4.000
0.000
130'
No Ice
0.067
0.117
0.001
(E)
0'
0'
(3) ACU-A20-N
B
From Leg
4.000
0.000
130'
No Ice
0.067
0:117
0.001
(E)
0'
0'
(3) ACU-A20-N
C
From Leg
4.000
0.000
130'
No Ice
0.067
0.117
0.001
(E)
0'
0'
RRUS-11 800MHZ
A
From Leg
4.000
0.000
130'
No Ice
2.522
1.303
0.054
(E)
0'
3'
RRUS-11 800MIlZ
B
From Leg
4.000
0.000
130'
No Ice
2.522
1.303
0.054
(E)
0'
3'
RRUS-11800NUIZ
C
From Leg
4.000
0.000
130'
No Ice
2.522
1.303
0.054
(E)
0'
3'
800MHZ SMR FILTER
A
From Leg
4.000
0.000
130'
No Ice
0.650
0.222
0.009
(E)
0'
3'
800MHZ SMR FILTER
B
From Leg
4.000
0.000
130'
No Ice
0.650
0.222
0.009
(E)
0'
3'
80OMHZ SMR FILTER
C
From Leg
4.000
0.000
130'
No Ice
0.650
0.222
0.009
(E)
0,
3'
(2) 7'x2" Antenna Mount Pipe
A
From Leg
4.000
0.000
130'
No Ice
1.663
1.663
0.026
(E)
U'
0'
tnxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
18 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01/23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX. (918) 295-0265
Description
Face
Offset
Offsets:
Azimuth
Placement
C,ytA
Cptq
Weight
or
Type
Hum
Adjustment
Front
Side
Leg
Lateral
Pert
R
o
F
lt,
JP
K
R
h
(2) Tx2" Antenna Mount Pipe
B
From Leg
4.000
0.000
130'
No Ice 1.663
1.663
0.026
(E)
0'
0'
(2) Tx2" Antenna Mount Pipe
C
From Leg
4.000
0.000
130'
No Ice 1.663
1.663
0.026
(li)
0'
0'
' Sector Mount ISM 702-31
C
None
0.000
130'
No Ice 37.400
37.400
1.551
Load Combinations
Comb. Description
2 1.2 Dead+1.0 Wind 0 deg -No Ice
3 0.9 Dead+1.0 Wind 0 deg -No Ice
4 12 Dead+1.0 Wind 30 deg - No Ice '
5 0.9 Dead+1.0 Wind 30 deg - No Ice
6 1.2 Dead+1.0 Wind 60 deg - No Ice
7 0.9 Dead+1.0 Wind 60 deg - No Ice
8 1.2 Dead+1.0 Wind 90 deg - No Ice ,
9 0.9 Dead+1.0 Wind 90 deg -No Ice
10 1.2 Dead+1.0 Wind 120 deg -No Ice
11 0.9 Dead+I.0 Wind 120 deg -No Ice
12 1.2 Dead+LO Wind 150 deg - No Ice
13 0.9 Dead+LO Wind 150 deg - No Ice
14 1.2 Dead+LO Wind 180 deg - No Ice
15 0.9 Dead+LO Wind 180 deg -No Ice
16 12 Dead+LO Wind 210 deg - No Ice
17 0.9 Dead+LO Wind 210 deg - No Ice
18 1.2 Dead+1.0 Wind 240 deg - No Ice
19 0.9 Dead+LO Wind 240 deg - No Ice
20 12 Dead+LO Wind 270 deg - No Ice
21 0.9 Dead+LO Wind 270 deg - No Ice
22 1.2 Dead+1.0 Wind 300 deg - No Ice
23 0.9 Dead+I.0 Wind 300 deg - No Ice
24 1.2 Dead+1.0 Wind 330 deg - No Ice
25 0.9 Dead+LO Wind 330 deg - No Ice
26 Dead+Wind 0 deg - Service
27 Dead+Wind 30 deg - Service
28 Dead+Wind 60 deg - Service
29 Dead+Wind 90 deg - Service
30 Dead+Wind 120 deg - Service
31 .Dead+Wind 150 deg- Service
32 Dead+Wind 180 deg - Service
33 Dead+Wind 210 deg -Service
34 Dead+Wind 240 deg - Service
35 Dead+Wind 270 deg -Service
36 Dead+Wind 300 deg - Service
37 Dead+Wind 330 deg- Service
tnxTower
J
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
19 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX.- (918) 295-0265
Maximum Member Forces
Section
Elevation
Component
Condition
Gov.
Axial
Major Axis
Minor Axis
No.
fr
Type
Load
Moment
Moment
Comb.
K
kip-jl
kip-Jt
TI
250-240
Leg
Max Tension
7
1.862
-0.691
0.296
Max. Compression
18
-3.633
0.698
-0.300
Max. Mx
8
-3.211
1.302
0.012
Max. My
3
0.587
-0.005
-1.334
Max. Vy
8
-0.987
-0.639
.-0.026
Max. Vx
3
1.012
-0.009
0.650
Diagonal
Max Tension
7
2.151
0.000
0.000
Max. Compression
is
-2.270
0.000
0.000
Max. Mx
22
-0.338
0.006
0.000
Max. My
24
-0.003
0.004
0.001
Max. Vy
22
0.006
0.006
0.000
Max. Vx
24
0.000
0.000
0.000
Top Girt
Max Tension
23
0.161
0.000
0.000
Max. Compression
10
-0.206
0.000
0.000
Max. Mx
2
0.060
-0.014
0.000
Max. Vy
2
0.009
0.000
0.000
T2
240 - 220
Leg
Max Tension
7
26.251
-0.130
-0.087
Max. Compression
18
-30A07
0.072
0.082
Max. Mx
11
-10.392
0.762
0.002
Max. My
4
-1.075
-0.001
-0.791
'
Max. Vy
3
0.198
0.754
-0.065
Max. Vx
4
-0.265
-0.001
-0.791
Diagonal
Max Tension
7
4.363
0.000
0.000
Max. Compression
18
-4.620
0.000
0.000
Max. Mx
6
3.014
0.020
-0.004
Max. My
18
-4.583
0.003
0.007
Max. Vy
6
0.012
0.020
-0.004
Max. Vx
6
0.002
0.000
0.000
T3
220-200
Leg
Max Tension
7
54.723
-0.090
-0.088
Max. Compression
18
-62.513
0.155
0.086
Max. Mx
19
-61.812
0.156
0.086
Max. My
16
-2.918
-0.010
0.226
Max. Vy
19
-0.112
0.153
0.068
Max. Vx
16
-0.163
-0.010
0.226
Diagonal
Max Tension
18
5.624
0.000
0.000
Max. Compression
18
-5.850
0.000
0.000
Max. Mx
18
3.667
0.025
0.007
Max. My
18
-5A36
0.006
0.007
Max. Vy
6
0.014
0.024
-0.007
Max. Vx
16
-0.002
0.000
0.000
T4
200 -180
Leg
Max Tension
7
85.264
-0.173
-0.093
Max. Compression
18
-97.541
0.073
0.085
Max. Mx
19
-84.563
0.180
0.093
Max. My
16
-4.842
-0.012
0.331
Max. Vy
19
-0.100
0.180
0.093
Max. Vx
16
0.211
-0.010
0.274
Diagonal
Max Tension
18
7.133
0.000
0.000
Max. Compression
18
-7.380
0.000
0.000
Max. Mx
6
4.238
0.042
-0.009
Max. My
18
-7.302
0.013
0.011
Max. Vy
6
0.020
0.042
-0.009
Max. Vx
18
-0.002
0.000
0.000
TS
180 - 160
Leg
Max Tension
7
114.973
0.179
-0.072
Max. Compression
18
-132.221
-0.241
0.066
Max. Mx
18
-132.066
0.479
0.023
tnx ower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
20 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23119
Tulsa, OK 74119
Client
Designed by
Phone. (918) 587-4630
Crown Castle
Kiran
FAX.. (918) 295-0265
Section Elevation Component Condition Gov. Axial Major Axis Minor Axis
No. jt Type Load Moment - Moment
Comb. K kip-jt kipJt
Max. Vy
18
-0.207
0.479
0.023
Max. Vx
16
0.205
-0.038
0.406
Diagonal
Max Tension
18
9.217
0.000
0.000
Max. Compression
18
-9.781
0.000
0.000
Max. Mx
2
7.456
0.058
0.000
Max. My
2
1.263
0.000
-0.002
Max. Vy
2
-0.027
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Horizontal
Max Tension
18
2.649
0.000
0.000
Max. Compression
18
-2.649
0.018
-0.001
Max. Mx
6
1.324
0.019
-0.001
Max. My
2
-0.154
0.016
-0.001
Max. Vy
6
-0.013
0.019
-0.001
Max. Vx
2
0.000
0.016
-0.001
Inner Bracing
Max Tension
1
0.000
0.000
0.000
Max. Compression
24
-0.003
0.000
0.000
Max. Mx
2
-0.003
-0.017
0.000
Max. Vy
2
0.010
0.000
0.000
T6 160 - 140 Leg
Max Tension
7
148.161
0.412
-0.074
Max. Compression
18
-173.775
0.454
0.097
Max. Mx
22
127.062
1.714
0.010
Max. My
24
-8.733
-0.045
-1.858
Max. Vy
22
-1.507
-1.250
0.010
Max. Vx
24
1.245
0.018
0.589
Diagonal
Niter Tension
19
11.873
0.000
0.000
Max. Compression
18
-12.553
0.000
0.000
Max. Mx
2
7.691
0.073
0.000
Max. My
2
1290
0.000
-0.002
Max. Vy
2
-0.031
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Horizontal
Max Tension
18
3.304
0.000
0.000
Max. Compression
18
-3.304
0.030
0.001
Max. Mx
22
-0.466
0.030
0.003
Max. My
10
0.516
0.028
-0.005
Max. Vy
22
0.019
0.030
0.003
Max. Vx
10
-0.001
0.028
-0.005
Inner Bracing
Max Tension
1
0.000
0.000
0.000
Max. Compression
22
-0.005
0.000
0.000
Max. Mx
2
-0.004
-0.023
0.000
Max. Vy
2
0.012
0.000
0.000
T7 140 - 120 Leg
Max Tension
7
192.784
0.233
-0.078
Max. Compression
18
-227.087
-0.416
0.088
Max. Mx
18
-226.843
0.727
0.002
Max. My
16
-10.205
-0.069
1.297
Max. Vy
22
-1.722
0.170
0.050
Max. Vx
16
1.910
-0.060
0.219
Diagonal
Max Tension
20
16.532
0.000
0.000
Max. Compression
18
-17.189
0.000
0.000
Max. Mx
2
13.287
0.089
0.000
Max. My
2
1.485
0.000
-0.003
Max. Vy
2
-0.035
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Horizontal
Max Tension
18
4.118
0.000
0.000
Max. Compression
18
4.118
0.042
-0.001
Max. Mx
18
-0.496
0.050
-0.001
Max. My
6
-2.021
0.042
-0.002
Max. Vy
18
-0.026
0.050
-0.001
Max. Vx
6
-0.001
0.042
-0.002
Inner Bracing
Max Tension
1
0.000
0.000
0.000
Max. Compression
12
-0.004
0.000
0.000
tnxTowes'
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
21 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone. (918) 587-4630
Crown Castle
Kiran
FAX (918) 295-0265
Section Elevation
Component
Condition
Gov.
Axial
Major Axis
Minor Axis
No. .R
Type
Load
Moment
Moment
Comb.
K
kipn
kip-t
Max. Mx
2
-0.004
-0.037
0.000
Max. Vy
2
0.017
0.000
0.000
T8 120-100
Leg
Max Tension
7
244.389
0.309
-0.071
Max. Compression
18
-287.505
-0.404
0.121
Max. Mx
18
-287.243
0.888
-0.014
Max. My
16
-16.004
-0.083
1.061
Max. Vy
18
-0.334
0.888
-0.014
Max. Vx
18
-0.346
0.081
1.029
Diagonal
Max Tension
20
18.592
0.000
0.000
Max. Compression
18
-18.950
0.000
0.000
Max. Mx
2
14.627
0.131
0.000
Max. My
2
1.133
0.000
-0.004
Max. Vy
2
-0.047
0.000
0.000
Max. Vx
2
0.002
0.000
0.000
Horizontal
Max Tension
18
4.991
0.000
0.000
Max. Compression
18
-4.991
0.053
-0.002
Max. Mx
18
-0.633
0.059
-0.001
Max. My
6
2.499
0.051
-0.002
Max. Vy
18
-0.029
0.059
-0.001
Max. Vx
6
-0.001
0.051
-0.002
Inner Bracing
Max Tension
1
0.000
0.000
0.000
Max. Compression
18
-0.005
0.000
0.000
Max. Mx
2
-0.005
-0.046
0.000
Max. Vy
2
0.019
0.000
0.000
T9 100 - 80
Leg
Max Tension
7
296.943
0.517
-0.065
Max. Compression
18
-350.249
-3.076
-0.125
Max. Mx
18
-350.249
-3.076
-0.125
Max. My
16
-16.815
-0.083
1.061
Max. Vy
18
1.029
1.730
0.032
Max. Vx
18
0.349
0.081
1.029
Diagonal
Max Tension
21
20.871
0.000
0.000
Max. Compression
20
-21.330
0.000
0.000
Max. Mx
2
16.560
0.253
0.000
Max. My
2
0.711
0.000
-0.008
Max. Vy
2
-0.084
0.000
0.000
Max. Vx
2
-0.003
0.000
0.000
Horizontal
Max Tension
18
6.074
0.000
0.000
Max. Compression
18
-6.074
0.085
-0.002
Max. Mx
18
-0.758
0.094
-0.003
Max. My
18
-0.758
0.094
-0.003
Max. Vy
18
-0.042
0.094
-0.003
Max. Vx
18
0.001
0.094
-0.003
Inner Bracing
Max Tension
1
0.000
0.000
0.000
Max. Compression
6
-0.008
0.000
0.000
Max. Mx
2
-0.008
-0.068
0.000
Max. Vy
2
0.025
0.000
0.000
T10 80 - 60
Leg
Max Tension
7
336.485
2.581
0.118
Max. Compression
18
-397.527
-4.536
0.103
Max. Mx
18
-397.527
4.536
0.103
Max. My
16
-22.708
-0.406
2.078
Max. Vy
18
-1.486
4.028
0.236
Max. Vx
16
-0.771
-0.406
2.078
Diagonal
Max Tension
20
26.664
-0.197
0.101
Max. Compression
18
-27.609
0.000
0.000
Max. Mx
18
25.353
-0.216
0.125
Max. My
18
18.714
-0.205
-0.125
Max. Vy
18
-0.055
-0.216
0.125
Max. Vx
18
0.018
0.000
0.000
Horizontal
Max Tension
18
6.894
0.000
0.000
Max. Compression
18
-6.894
-0.121
0.003
Max. Mx
18
-0.634
-0.136
0.005
WxTower
Job
Page
'
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 613812)
22 of 39
B+T Group
Project
Date
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone. (918) 587-4630
Crown Castle
Kiran
FAX (918) 295-0165
Section Elevation
Component
Condition
Gov.
Axial
Major Axis
MinorAsis
No. ft
Type
Load
Moment
Moment
Comb.
K
kio-ft
kip-jt
Max. My
18
-0.634
-0.136
0.005
'
Max. Vy
18
0.056
-0.136
0.005
Max. Vx
18
-0.002
-0.136
0.005
Redund Hors I
Max Tension
18
6.896 "
0.000
0.000
Bracing
Max. Compression
18
-6.896
0.000
0.000
Max. Mx
2
6.237
0.025
0.000
'
Max. My
2
0.141
0.000
-0.001
Max. Vy
2
0.018
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Redund Ding 1
Max Tension
18
4.684
0.000
0.000
Bracing
Max. Compression
18
-4.684
0.000
0.000
Max. Mx
2
1.051
0.036
0.000
Max. My
2
OA13
0.000
-0.001
Max. Vy
2
-0.018
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Redund Hip I
Max Tension
19
0.036
0.000
0.000
Bracing
Max. Compression
6
-0.039
0.000
0.000
Max. Mx
2
-0.008
-0.016
0.000
Max. Vy
2
-0.011
0.000
0.000
Inner Bracing
Max Tension
7
0.018
0.000
0.000
Max. Compression
18
-0.030
0.000
0.000
Max. Mx
2
0.004
0.101
0.000
Max. Vy
2
-0.035
0.000
0.000
TI1 60-40
Leg
Max Tension
7
389.519
3.586
-0.117
Max. Compression
18
-461.048
-3.503
0.209
Max. Mx
18
458.755
4.976
0.240
Max. My
16
-23.799
-0.406
2.078
Max. Vy
18
-1.965
4.976
0.240
Max. Vx
19
-0.595
1.445
I.077
Diagonal
Max Tension
20
27.870
-0.197
0.088
Max. Compression
18
-28.755
0.000
0.000
Max. Mx
18
26.393
-0.213
0.110
Max. My
18
20.432
-0.201
-0.110
Max. Vy
18
-0.055
-0.213
0.I10
Max. Vx
19
0.015
0.000
0.000
Horizontal
Max Tension
18
7.996
0.000
0.000
Max. Compression
18
-7.996
-0.157
0.005
Max. Mx
6
-3.917
-0.161
0.005
Max. My
6
-3.917
-0.161
0.005
Max. Vy
6
0.061
-0.161
0.005
Max. Vx
6
-0.002
-0.161
0.005
Redund Horz 1
Max Tension
18
7.997
0.000
0.000
Bracing
Max. Compression
19
-7.997
0.000
0.000
Max. Mx
2
0.441
0.030
0.000
Max. My
2
-0.512
0.000
-0.001
Max. Vy
2
-0.019
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Redund Ding I
Max Tension
18
5.247
0.000
0.000
Bracing
Max. Compression
18
-5.247
0.000
0.000
Max. Mx
2
0.897
0.041
0.000
Max. My
2
0.794
0.000
-0.001
•
Max. Vy
2
-0.020
0.000
0.000
Max. Vx
2
-0.001
0.000
0.000
Redund Hip 1
Max Tension
19
0.029
0.000
0.000
Bracing
Max. Compression
6
-0.034
0.000
0.000
tnxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
23 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01/23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX (918) 295-0265
Section
Elevation
Component
Condition
Gov.
Axial
Major Axis
Minor Axis
No.
ft
Type
Load
Moment
Moment
Comb.
K
kipJt
kip-ft
Max. Mx
2
-0.007
-0.019
0.000
Max. Vy
2
0.012
0.000
0.000
Inner Bracing
Max Tension
7
0.014
0.000
0.000
Max. Compression
18
-0.026
0.000
0.000
Max. Mx
2
0.003
0.120
0.000
Max. Vy
2
0.038
0.000
0.000
T12
40-20
Leg
Max Tension
7
442.381
2.873
-0.209
Max. Compression
18
-524.438
-5.689
0.094
Max. Mx
18
-524.438
-5.689
0.094
Max. My
16
-29.870
-0.536
2.957
Max. Vy
18
1.811
3.084
-0.218
Max. Vx
16
-0.968
-0.536
2.957
Diagonal
Max Tension
20
29.006
-0.249
0.104
Max. Compression
18
-29.733
0.000
0.000
Max. Mx
18
27.731
-0.271
0.130
Mani. My
18
21.671
-0.259
-0.130
Max. Vy
18
0.073
-0.271
0.130
Max. Vx
18
0.017
0.000
0.000
Horizontal
Max Tension
18
9.095
0.000
0.000
Max. Compression
18
-9.095
-0.168
0.005
Max. Mx
18
-0.927
-0.186
0.006
Max. My
2
-0.874
-0.185
0.006
Max. Vy
18
0.066
-0.186
0.006
Max. Vx
2
0.002
-0.185
0.006
Redund Hoa 1
Max Tension
18
9.097
0.000
0.000
Bracing
Max. Compression
18
-9.097
0.000
0.000
Max. Mx
2
0.706
0.035
0.000
Max. My
2
-0.067
0.000
-0.001
Max. Vy
2
0.021
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Redund Diag 1
Max Tension
18
5.798
0.000
0.000
Bmcing
Max. Compression
18
-5.798
0.000
0.000
Max. Mx
2
0.960
0.046
0.000
Max. My
2
0.674
0.000
-0.002
_
Max. Vy
2
-0.021
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Redund Hip 1
Max Tension
19
0.032
0.000
0.000
Bracing
Max. Compression
6
-0.038
0.000
0.000
Max. Mx
2
-0.011
-0.022
0.000
Max. Vy
2
0.013
0.000
0.000
Inner Bracing
Max Tension
7
0.017
0.000
0.000
Max. Compression
18
-0.032
0.000
0.000
Max. Mx
2
0.003
0.176
0.000
Max. Vy
2
-0.052
0.000
0.000
T13 20-0 Leg
Max Tension
7
493.063
4.434
-0.111
Max. Compression
18
-587.351
0.000
-0.000
Mai. Mx
18
-584.062
-5.689
0.094
Max. My
16
-31.272
-0.536
2.957
Max. Vy
18
-2.317
5.655
0.226
Max. Vx
16
0.486
-0.536
2.957
Diagonal
Max Tension
20
29.754
-0,249
0.089
Max. Compression
18
-30.387
0.000
0.000
Max. Mx
18
26.643
-0.266
0.112
Max. My
18
27.922
-0.266
0.112
'
Max. Vy
18
-0.074
-0.266
0.112
Max. Vx
18
-0.015
0.000
0.000
Horizontal
Max Tension
18
10.186
0.000
0.000
Max. Compression
18
-10.186
-0.259
0.008
tnxToweY
Jab
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
24 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX.. (918) 295-0265
Section Elevation Component
No. Jt Type
Condition
Gov.
Load
Comb.
Axial
K
Major Axis
Moment
kip J1
Minor Axis
Moment
k4 -jt
Max. Mx
6
-4.992
-0.269
0.008
Max. My
6
-4.992
-0.269
0.008
Max. Vy
6
0.086
-0.269
0.008
Max Vx
6
-0.003
-0.269
0.008
Redund Horz I
Max Tension
18
10.187
0.000
0.000
Bracing
Max. Compression
l8
-10.187
0.000
0.000
Max. Mx
2
0.575
0.040
0.000
Max. My
2
0.013
0.000
-0.001
•
Max. Vy
2
-0.022
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Redund Dias 1
Max Tension
18
6.333
0.000
0.000
Bracing
Max. Compression
18
-6.333
0.000
0.000
Max. Mx
2
0.878
0.052
0.000
Max. My
2
1.031
0.000
-0.002
Max. Vy
2
-0.023
0.000
0.000
Max. Vx
2
0.001
0.000
0.000
Redund Hip 1
Max Tension
19
0.026
0.000
0.000
Bracing
Max. Compression
6
-0.033
0.000
0.000
Max. Mx
2
-0.010
-0.025
0.000
'
Max. Vy
2
0.014
0.000
0.000
Inner Bracing
Max Tension
7
0.012
0.000
0.000
Max. Compression
18
-0.029
0.000
0.000
Max. Mx
2
0.000
0.203
0.000
Max. Vy
2
-0.056
0.000
0.000
Maximum Reactions
Location
Condition
Gov.
Load
Comb.
Vertical
K
Horizontal, X
K
Horizontal, Z
K
Leg
Max. Vert
18
617.063
65.742
-35.013
Max. H.
18
617.063
65.742
-35.013
Max. Hz
7
-517.835
-57.012
30.029
Min. Vert
7
-517.835
-57.012
30.029
Min. H.
7
-517.835
-57.012
30.029
Min. H.
18
617.063
65.742
-35.013
Leg
Max. Vert
10
567.591
-60.088
-33.156
'
Max. H,
21
-440.939
51.681
21.434
Max. H.
25
-394.177
41.681
28.170
Min. Vert
23
464.501
51.323
28.112
Min. H.
10
567.591
-60.088
-33.156
Min. H,
10
567.591
-60.088
-33.156
Leg
Max. Vert
2
561.871
-0.106
68.247
Max. H.
20
32.772
8.904
2.654
Max. H,
2
561.871
-0.106
68.247
Min. Vert
15
464.153
0.140
-58.219
Min. H.
9
22.765
-8.869
1.822
Min. H.
15
-464.153
0.140
-58.219
Tower Mast Reaction Summary
MxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
25 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX (918)295-0265
Load
Combination
Vertical
K
Shear,
K
Shear,
K
Overturning
Moment, M.
kip-ft
Overturning
Moment, M.
ktp-ft
Torque
kip-ft
Dead Only
82.616
0.000
0.000
28.385
-27.588
0.000
1.2 Dead+1.0 Wind 0 deg - No
99.140
-0.161
-114.691
-13739.261
-6.177
-7.098
Ice
0.9 Dead+1.0 Wind 0 deg -No
74.355
-0.161
-114.691
-13747.776
2.099
-7.098
Ice
1.2 Dead+1.0 Wind 30 deg -No
99.140
55.979
-96.959
-11821.643
-6878.000
105.265
Ice
0.9 Dead+1.0 Wind 30 deg -No
74.355
55.979
-96.959
-11830.158
-6869.723
105.265
Ice
1.2 Dead+1.0 Wind 60 deg -No
99.140
100.168
-57.646
-6987.097
-12247.965
130.411
Ice
0.9 Dead+1.0 Wind 60 deg -No
74.355
100.168
-57.646
-6995.612
-12239.688
130.411
Ice
1.2 Dcad+1.0 Wind 90 deg -No
99.140
115.563
0.161
60.990
-14028.859
98.793
Ice
0.9 Dead+1.0 Wind 90 deg -No
74.355
115.563
0.161
52.474
-14020.583
98.793
Ice
1.2 Dead+1.0 Wind 120 deg-
99.140
99.811
57.626
6955.149
-12020.781
68.681
No Ice
0.9 Dead+1.0 Wind 120 deg-
74.355
99.811
57.626
6946.634
-12012.504
68.681
No Ice
1.2 Dead+1.0 Wind 150 deg-
99.140
52.655
90.879
10926.356
-6352.868
71.565
No Ice
0.9 Dead+1.0 Wind 150 deg -
74.355
52.655
90.879
10917.841
-6344.592
71.565
No Ice
1.2 Dead+1.0 Wind 180 deg-
99.140
6.161
104.911
12711.499
-60.033
7.098
No Ice
0.9 Dead+1.0 Wind 180 deg-
74.355
0.161
104.911
12702.984
-51.757
7.098
No Ice
1.2 Dead+1.0 Wind 210 deg-
99.140
-55.979
96.959
11889.766
6811.789
-105.265
No Ice
0.9 Dead+1.0 Wind 210 deg-
74.355
-55.979
96.959
11881.251
6820.065
-105.265
No Ice
1.2 Dead+1.0 Wind 240 deg-
99.140
-108.638
62.536
7603.163
13130.818
-130.411
No Ice
0.9 Dead+1.0 Wind 240 deg-
74.355
-108.638
62.536
7594.647
13139.095
-130.411
No Ice
1.2 Dead+1.0 Wind 270 deg-
99.140
-115.563
-0.161
7.134
13962.648
-98.793
No Ice
0.9 Dead+1.0 Wind 270 deg-
74.355
-115.563
-0.161
-1.382
13970.925
-98.793
No Ice
1.2 Dead+1.0 Wind 300 deg-
99.140
-91.341
-52.736
-6339.083
11005.506
-68.681
No Ice
0.9 Dead+1.0 Wind 300 deg-
74.355
-91.341
-52.736
-6347.599
11013.782
-68.681
No Ice
1.2 Dead+1.0 Wind 330 deg-
99.140
-52.655
-90.879
-10858.233
6286.658
-71.565
No Ice
0.9 Dead+1.0 Wind 330.deg -
74.355
-52.655
-90.879
-10866.749
6294.934
-71.565
No Ice
Dead+Wind 0 deg - Service
82.616
-0.025
-17.632
-2089.090
-23.448
-1.091
Dead+Wind 30 deg -Service
82.616
8.606
-14.906
-1794.281
-1079.904
16.183
Dead+Wind 60 deg- Service
82.616
15.400
-8.862
-1051.030
-1905.469
20.049
Dead+Wind 90 deg- Service
82.616
17.766
0.025
32.524
-2179.259
15.188
Dead+Wind 120 deg- Service
82.616
15.345
8.859
1092.415
-1870.542
10.559
Dead+Wind 150 deg- Service
82.616
8.095
13.971
1702.938
-999.172
11.002
Dead+Wind 180 deg- Service
82.616
0.025
16.129
1977.381
-31.728
1.091
Dead+Wind 210 deg - Service
' 82.616
-8.606
14.906
1851.050
1024.729
-16.183
Dead+Wind 240 deg -Service
82.616
-16.702
9.614
1192.039
1996.200
-20.049
Dead+Wmd 270 deg - Service
82.616
-17.766
-0.025
24.245
2124.083
-15.188
Dead+Wind 300 deg - Service
82.616
-14.042
-8.107
-951.406
1669A60
-10.559
tnxTower
Job --
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
26 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 5874630
Crown Castle
Kiran
FAX (918) 295-0265
Load Vertical Shear, Shear, Overturning Overturning Torque
Combination Moment M. Moment, M
Dead+Wind 330 dee- Service 82.616 -8.095-13.971-1646.169 943.996 -11.002
Solution Summary
Sum of Applied Forces
Sum of Reactions
Load
PX
PY
PZ
PX
PY
PZ
%Error
Comb.
K
K
K
K
K
K
1
0.000
-82.616
0.000
-0.000
82.616
-0.000
0.000%
2
-0.161
-99.140
-114.691
0.161
99.140
114.691
0.000%
3
-0.161
-74.355
-114.691
0.161
74.355
114.691
0.000%
4
55.979
-99.140
-96.959
-55.979
99.140
96.959
0.000%
5
55.979
-74.355
-96.959
-55.979
74.355
96.959
0.000%
6
100.168
-99.140
-57.646
-100.168
99.140
57.646
0.000%
7
100.168
-74.355
-57.646
-100.169
74.355
57.646
0.000°%
8
115.563
-99.140
0.161
-115.563
99.140
-0.161
0.000%
9
115.563
-74.355
0.161
-115.563
74.355
-0.161
0.000%
10
99.811
-99.140
57.626
-99.811
99.140
-57.626
0.000%
11
99.811
-74.355
57.626
-99.811
74.355
-57.626
0.000%
12
52.655
-99.140
90.879
-52.655
99.140
-90.879
0.000%
13
52.655
-74.355
90.879
-52.655
74.355
-90.879
0.000%
14
0.161
-99.140
104.911
-0.161
99.140
-104.911
0.000%
15
0.161
-14.355
104.911
-0.161
74.355
-104.911
0.000%
16
-55.979
-99.140
96.959
55.979
99.140
-96.959
0.000%
17
-55.979
-74.355
96.959
55.979
74.355
-96.959
0.000%
18
•-108.638-99.140
62.536
108.638
99.140
'62.536
0.000%
19
-108.638
-74.355
62.536
108.638
74.355
-62.536
0.000%
20
-115.563
-99.140
-0.161
115.563
99.140
0.161
0.000%
21
-115.563
-74.355
-0.161
115.563
74.355
0.161
0.000%
22
-91.341
-99.140
-52.736
91.341
99.140
52.736
0.000%
23
-91.341
-74.355
-52.736
91.341
74.355
52.736
0.000%
24
-52.655
-99.140
-90.879
52.655
99.140
90.879
0.000%
25
-52.655
-74.355
-90.879
52.655
74.355
90.879
0.000%
26
-0.025
-82.616
-17.632
0.025
82.616
17.632
0.000%
27
8.606
-82.616
-14.906
-8.606
82.616
14.906
0.000%
28
15.400
-82.616
-8.862
-15.400
82.616
8.862
0.000%
29
17.766
-82.616
0.025
-17.766
82.616
-0.025
0.000%
30
15.345
-82.616
8.859
-15.345
82.616
-8.859
0.000%
31
8.095
-82.616
13.971
-8.095
82.616
-13.971
0.000%
32
0.025
-82.616
16.129
-0.025
82.616
-16.129
0.000%
33
-8.606
-82.616
14.906
8.606
82.616
-14.906
0.000%
34
-16.702
-82.616
9.614
16.702
82.616
-9.614
0.000%
35
-17.766
-82.616
-0.025
17.766
82.616
0.025
0.000%
36
-14.042
-92.616
-8.107
14.042
82.616
8.107
0.000%
37
-8.095
-82.616
-13.971
8.095
82.616
13.971
0.000%
Maximum Tower Deflections - Service Wind
Section
Elevation
Hon.
Gov.
Tilt
Twist
No.
Deflection
Load
fl
in
Comb.
0°
TI
250 - 240
3.565
34
0.115
0.035
T2
240 - 220
3.323
34
0.114
0.034
T3
220-200
2.840
34
0.109
0.031
MxTowel'
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
27 of 39
B+T Group
Project
Date
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX (918) 295-0265
Section
Elevation
Horz.
Gov.
Tilt
Twist
No.
Deflection
Load
R
in
Comb.
T4
200-180
2.381
34
0.102
0.027
T5
180-160
1.953
34
0.094
0.022
T6
160-140
1.570
34
0.083
0.019
17
140 - 120
1.229
34
0.072
0.016
T8
120-100
0.923
34
0.062
0.013
T9
100 - 80
0.662
34
0.051
0.010
T10
80 - 60
0.452
34
0.040
0.008
TI1
60-40
0.271
34
0.030
0.006
T12
40-20
0.137
34
0.020
0.003
T13
20-0
0.042
34
0.010
0.002
Critical Deflections and Radius of Curvature - Service Wind
Elevation
_ ft
Appurtenance
Gov.
Load
Comb.
Deflection
in
Tilt
o
Twist
oft
Radius of
Curvature
249'6"
Flash Beacon Lighting
34
3.553
0.115
0.035
Inf
243'
(2)X7CQAP-665-VRO
34
3.396
0.115
0.035
906124
234'
4' Dipole
34
3.177
0.114
0.034
866558
215'
4' Dipole
34
2.723
0.108
0.030
156720
191,
4' Dipole
34
2.183
0.099
0.024
128641
177'
4' Dipole
34
1.892
0.092
0.021
98192
143'
DC648-60-18-8F
34
1.278
0.014
0.016
142673
130'
TTIT65AP-1XR w/Mount Pipe
34
1.072
0.067
0.014
130232
125'
Side Liehfine
34
0.996
0.064
0.013
122065
Maximum Tower Deflections - Design Wind
Section
Elevation
Horz.
Gov.
Tilt
Twist
No.
Deflection
Load
(1
in
Comb.
o
Tl
250-240
23.320
19
0:753
0.226
T2
240-220
21.733
19
0.750
0.224
T3
220 -200
18.569
19
0.718
0.203
T4
200 -180
15.560
19
0.670
0.172
T5
ISO- 160
12.757
19
0.613
0.142
T6
160 - 140
10.250
19
0.542
0.123
T7
140 - 120
8.022
19
0,471
0.103
T8
120 - 100
6.026
19
0.402
0.081
T9
100 - 80
4.319
19
0.332
0.064
T10
80 - 60
2.950
19
0.262
0.053
Tll
60-40
1.766
19
0.195
0.037
T12
40-20
0.891
19
0.132
0.022
T13
20 - 0
0.275
18
0.063
0.011
Critical Deflections and Radius of Curvature - Design Wind
WxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
28 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 5874630
Crown Castle
Kiran
FAX (918) 295-0265
Elevation
Appurtenance
Gov.
Deflection
Tilt
Twist
Radius of
Load
Curvature
fl
Comb.
in
oR
249V
Flash Beacon Lighting
1.9
23.241
0.753
0.226
196871
243'
(2)X7CQAP-665-VRO
19
22.210
0.752
0.225
144530
234'
4' Dipole
19
20.778
0.744
0.220
159737
215'
4'Dipole
19
17.799
0.706
0.196
24702
191,
4' Dipole
19
14.268
0.646
0.158
19547
177'
4' Dipole
19
12.361
0.603
0.139
14954
143'
DC648-60-18-SF
19
8.341
0.482
0.106
21649
130'
TTTT65AP-1XR w/Mount Pipe
19
6.994
0.437
0.092
19821
125'
Side Lighting
19
6.502
0.420
0.087
18604
Bolt Design Data
Criteria
Section
Elevation
Component
Bolt
Bolt Size
Number
Maximum
Allowable
Ratio
Allowable
No.
Type
Grade
Of
Load
Load
Load
Ratio
ft
in
Bolts
per Bolt
per Bolt
Allowable
K
K
T1
250
Leg
A325N
0.625
4
OA66
20.340
�
"05
Bolt Tension
0.023
Diagonal
A325N
0.625
2
1.075
6.785
1.05
Member Block
0158
Shear
Top Girt
A325N
0.625
1
0.161
7.875
1.05
Member Block
0.020
f✓
Shear
T4
240
Leg
A325N
0.625
6
4.375
20.340
"05
Bolt Tension
0215
�/
Diagonal
A325N
0.625
2
2.182
7.805
1.05
Member Block
0280
Shear
73
220
Leg
A325N
0.875
6
9.121
41.556
LOS
Bolt Tension
0219
Diagonal
A325N
0.625
2
2.812
7.805
1.05
Member Block
0.360
Shear
T4
200
Leg
A325N
1.000
6
14.211
54.517
1.05
Bolt Tension
0.261
�/
Diagonal
A325N
0.625
2
3.567
8.314
1.05
Member Block
0.429
t✓
Shear
T5
180
Leg
A325N
1.000
6
19.138
54.517
1.05
Bolt Tension
0.351
Diagonal
A325N
0.625
2
4.609
15.609
1.05
Member Block
0295
y/
Shear
Horizontal
A325N
0.625
I
2.649
7.875
1.05
Member Block
0.336
Shear
T6
160
Leg
A325N
1.000
6
24.663
54.517
1.05
Bolt Tension
0.452
Diagonal
A325N
0.625
2
5.936
15.609
1.05
Member Block
0380
�/
Shear
Horizontal
A325N
0.625
1
3.304
9.914
1.05
Member Block
0.333
Shear
T7
140
Leg
A325N
1.125
6
32.034
68.695
1.05
Bolt Tension
0.466
f�
Diagonal
A325N
0.625
2
8,266
15.609
1.05
Member Block
0.530
Shear
Horizontal
A325N
0.625
1
4.118
10.934
1.05
Member Block
0377
i/
Shear
T8
120
Leg
A325N
1.250
6
40.691
87.220
"05
Bolt Tension
0.467
Diagonal
A325N
0.625
2
9.296
16.629
1.05
Member Block
0.559
Shen
Horizontal
A325N
0.625
1
4.991
10.934
1.05
Member Block
0.457
Shear
T9
100
Leg
A325N
1.250
6
49.436
87.220
"05
Bolt Tension
0.567
tnxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
29 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 5874630
Crown Castle
Kiran
FAX (918) 295-0265
Section
Elevation
Component
Bolt
Bolt Size
Number
Maximum
Allowable
Ratio
Allowable
Criteria
No.
Type
Grade
Of
Load
Load
Load
Ratio
ft
in
Bolts
per Bolt
per Bolt
Allowable
K
K
'
Diagonal
A325X
0.625
2
10.436
25.658
1.05
Member Block
0407
1/
Shear
Horizontal
A325N
0.625
1
6.074
13.806
/
1.05
Bolt Shear
0.440
T10
80
Leg
A325N
1.375
6
55.916
103.939
1.05
Bolt Tension
0.538
Diagonal
A325N
0.625
2
13.332
16.629
i/
1.05
Member Block
0802
Shear
Horizontal
A325N
0.625
1
6.894
19.828
1.05
Member Block
0348
Shear
Tit
60
Leg
A325N
1.500
6
64.786
126.472
L0'
Bolt Tension
0512
//
Diagonal
A325N
0.625
2
13.935
16.629
1.15
Member Block
0.838
l/
Shear
Horizontal
A325N
0.625
1
7.996
19.828
1.05
Member Block
0.403
Shear
T12
40.
Leg
A325N
1.500
6
73.514
126.472
1.15
Bolt Tension
0.581
i/
Diagonal
A325N
0.625
2
14.503
22.172
LOS
Member Block
0.654
Shear
Horizontal
A325N
0.625
1
9.095
19.828
1.05
Member Block
0.459
Shear
T13
20
Diagonal
A325N
0.625
2
14.877
22.172
1'05
Member Block
0.671
Shear
Horizontal
A325N
0.625
1
10.186
21.867
"05
Member Block
0.466
Shear
Compression Checks
Leg Design Data (Compression)
Section Elevation Size L L. Kl/r A P. gyp" Ratio
No. P.
ft ft ft in K K hP-
K=1.00
v
T2
240-220
21/2
20'13/32
68-1/8"
128.2
4.909
-30.407
67.460
0.451'
"
K=1.00
`/
T3
220-200
3
20'13/32
6'8-1/8"
106.8
7.069
-62.513
139.053
0.453'
_
K=1.00
`/
T4
200-180
31/4
20'13/32
6'8-1/8"
98.6
8.296
-97.541
183.313
0.532'
"
K=1.00
`/
T5
180-160
31/4
20'13/32
5'3/32"
74.0
8.296
-132.221
250.223
0.528'
"
K=1.00
T6
160-140
31/2
20'13/32
5'3/32"
68.7
9.621
-173.775
306.641
0.567'
"
K=1.00
v
T7
140- 120
3 3/4
20'13/32
5'3/32"
64.1
11.045
-227.097
368.015
0.617'
K=1.00
T8
120-100
4
20'13/32
5'3/32"
60.1
12.566
-287.506
434.236
0.662'
"
K=1.00
T9
100-80
41/4
20'13/32
5'3/32"
56.6
14.186
-350.249
505.220
0.693'
MxTower
B+T Group
1717 S. Boulder, Suite 300
Tulsa, OK 74119
Phone. (918) 587-4630
Job
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Project
Crown Castle
30 of 39 .
14:12:19 01/23/19
Designed by
Kiran
Section
Elevation
Size
L
L.
K11r
A
P.
Ratio
No.
P.
ft
ft
ft
in2
K
K
gyp"
"
K=1.00
T10
.80 - 60
4 1/2
20'13/32
5'3/32"
53.4
15.904
-397.527
580.902
0.684 '
"
K=1.00
V/
T11
60-40
43/4
20'13/32
5'3/32"
50.6
17.721
-461.048
661.231
0.697'
"
K=1.00
`/
T12
40-20
43/4
20'13/32
5'3/32"
50.6
17.721
-524.438
661.231
0.793'
"
K=1.00
101
T13
20-0
5
20'13/32
5'3/32"
48.1
19.635
-587.351,
746.168
0.787'
"
K=1.00
v
1 P„ / �P" contrOIS
Dia' onal Design Data Com ression
Section Elevation Size - L L. Kl/r A P. �P„ Ratio
No. P.
ft ft f1 - in' K K $p'
2"
K=L03
v
T2
240-220
L212x21/2x3/16
10'1-15/
411-9/3
119.8
0.902
-4.620
17.814
0.259'
16",
2"
K=1.00
. v
T3
220-200
L21/2x21/2x3/16
11'8-15/
5'8-3/8"
133.9
0.902
-5.850
14.405
0.406'
16"
K4.97
v
T4
200-180
L3x3x3/16
13'5-1/4'
66-3/8"
128.8
1.090
-7.380
18.804
0.392'.
K=0.98
v
T5
180-160
2L212x2120/16x3/8
8'7-1/4"
7-11-7/8'
126.4
1.800
-9.781
31.362
0.312'
K=1.00
2L'a' > 45.287 in - 86
T6
160-140
2L2 1/2x2 1/2x3/16x3/8
9'5-7/32'
8'9-25/3
139:5
1.800
-12.554
25.901
0.485'
'
2"
K=1.00
2L'e> 48.196 in - 125
T7
140-120
2L212x21/20/160/8
101-9/1
9'8-1/32'
153.0
1.800
-17.189
21.613
0.795'
6"
K=1.00
2L'a' > 51.206 in - 164
T8
120-100
2L3x3x3/16x3/8
11'2-3/1
10'6-9/1
140.3
2.180
-19.950
30.645
0.618'
6"
6"
K=1.00
2L'a'> 57.705 in-203
T9
100 - 80
2L3x3x5/16x3/8
12'1"
11'5-151
153.0
3.550
-21.330
43.016
0.496'
16"
K=1.00
2L'a' > 61.049 in - 242
T10
80-60
2L3x3x3/16x3/8
157-15/
15'4-9/1
102.3
2.180
-27.609
49.905
0.563'
32"
6"
K=0.50
2L'a' > 44.623 in - 281
T11
60-40
2L3x3x3/16x3/8
16'4-27/
16'1-27/
107A
2.180
-28.755
47.474
0.6061
32"
32"
K-0.50
2L'a' > 46.853 in - 332
T12
40-20
2L3x3xl/4x3/8
172-15/
16'11-9/
112.9
2.890
-29.733
60.916
0.488'
32"
16"
K=0.50
'
2L'a'>49.290 in-383
T13
20-0
2L3x3xl/4x3/8
18'3/8"
17'9-3/8'
118.4
2.880
-30.387
56.834
0.535'
'
K=0.50
MxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
31 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23119
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX (918) 295-0265
Section Elevation Size L L. K11r A P. laP„ Ratio
No. P.
Jt ft ft in, K K 8P-
1 P„ / �P, controls
2L'a'> 51.647 in - 434
Horizontal Design Data (Compression)
Section
Elevation
Size
L
L„
K11r
A
P.
�P"
Ratio
No.
P.
ft
ft
ft
in'
K
K
�P"
T5
180 - 160
L2x2x3/16
13'6"
65-5/8"
197.0
0.715
-2.649
5.272
0.502 '
K=1.00
`/
T6
160 -140
L2 11W 1/20/16
15'6"
7'5-1/2"
180.8
0.902
-3.304
7.897
0.418'
K=1.00
v
T7
140-120
L3x3x3/16
17'6"
8'5-3/8"
170.1
1.090
-4.118
10.783
0.382'
K=L00
v
T8
120- 100
L3x3x3/16
19'6"
9'5-1/4"
190.0
1.090
4.991
8.641
0.578'
K=L00
t/
T9
100-80
L3x3xl/4
21'6"
10'5-1/8'
211.4
1.440
-6.074
9.226
0.658'
K=1.00 •
v
T10
80-60
2L21/2x2120/160/8
23'
11'3-3/4'
179.0
1.800
-6.894
15.874
0.434'
'
K=1.00
`/
2L'a' > 64.778 in - 280
Tll 60-40 2L21/2x2120/160/8
25' 12'3-5/8' 194.6 1.800
-7,996
13.451 0.594'
' K=1.00
I/
2L'a' > 70.444 in - 331
T12 40-20 2L2 1/2x2 1/2x3/16x3/8
27' 13'3-5/8' 210.5 1.800
-9.095
11.524 0.789'
' K=1.00
2L'a' > 76.171 in - 382
T13 20 -0 2L3x3x3/16x3/8
29' 14'3-12' 190.1 2.180
-10.186
16.969 0.6001
' K=1.00
2L'a' > 81.641 in - 433
' P. / V. Controls
Top Girt Design Data (Compression)
Section Elevation Size
L
L.
KUr
A
P.
gyp"
Ratio
No.
P.
ft
ft
ft
in'
K
K
V.
Tl 250-240 LWx3/16
6'
5'6-12"
168.8
0.715
-0.206
7.184
0.029'
K=I.00
t/
1 P„ / �P" controls
tnx owe%
Job --
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
32 of 39 '
B+T Group
Project
Date
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Client
Designed by
Tulsa, OK 74119
Phone: (918) 587-4630
Crown Castle
Kiran
FAX (918) 295-0265
Redundant Horizontal 1 Design Data (Compression)-
Section
No.
Elevation
ft
Size
L
ft
L.
ft
KI/r
A
in'
P.
K
K
Ratio
P.
V.
T10
80-60
2L2x2x3/16x3/8
5'9"
5'6-3/4"
108.8
1.430
-6.896
31.854
0.216'
K=1.00
2L'a' > 31.969 in - 282
Tll
60-40
2L2x2x3/16x3/8
6'3"
65/8"
118.4
1.430
-7.997
28.340
0.282'
K=1.00
2L'a' > 34.782 in - 333
T12
40-20
2L2x2x3/16x3/8
6'9"
6'6-5/8"
128.2
1.430
-9.097
24.504
0.371'
K=1.00
2L'a' > 37.656 in - 384
T13
20-0
2L2x2x3/16x3/8
7'3"
T12"
137.8
1.430
-10.187
21.265
0.479'
K=1.00
2L'a'> 40.470 in - 435
1 P" / OP" controls
Redundant Diagonal
1
Design Data
(Compression)
Ratio
Section Elevation
Site
L
L.
KUr A
P.
r P"
No.
P.
Jj
ft
jt
in'
K
K
�P"
TIO 80-60
2L2x2x3/16x3/8
79-3/4"
7'6-11/1 147.9 1.430
-4.684
18.494
0.253 '
6"
K=1.00
k/
2L'a'> 43.438 in - 309
Tit 60-40
2L2x2x3/16x3/8
82-7/16'
T11-5/1
155A
IA30
-5.247
16.761 0.3131
'
6"
K=1.00
t%
2L'a'> 45.657 in - 360
T12 40-20
2L2x2x3/16x3/8
8'7-1/4"
8'4-1/4"
163.4
1.430
-5.798
15.174 0.382'
K=1.00
2L'a'> 48.011 in - 411
T13 20 -0
2L2x2x3/16x3/8
9'3/16"
8'9-3/32'
171.4
1.430
-6.333
13.815 0.4581
'
K=1.00
2L'a' > 50.340 in - 462
1P. / �P" controls
Redundant Hi
1
Design
Data (Compression)
Ratio
Section
Elevation
Site
L
L"
KUr A P.
rpP,
No.
P.
f
ft
ft
in' K
K
gyp"
TIO
80-60
L212x21/2x3/16
519"
519"
139.4 0.902 -0.039
13.287
0.003'
K=1.00
Tll
60-40
L2 1/2x2 1/2x3/16
69"
69"
151.5 0.902 -0.034
11.246
0.003'
K=1.00
T12
40-20
L212x212x3/16
6'9"
6'9"
163.6 0.902 -0.038
9.642
0.004'
t
' tnxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
33 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX: (918) 295-0265
Section Elevation Size L L. KUr A P. OP" Ratio
No. P.
ft ft ft in K K op.
V
T13 20-0 L212x2120/16 TY TY 175.8 0.902 -0.033 8.357 0.004'
K=1.00 11/
1 P " / r P. controls
Inner Bracing Design Data (Compression)
Section Elevation Size L L" KUr A P. rpP„ Ratio
No. P.
Jf ft ft in' K K �P"
15
18U - 160
L2x2x3/16
6'9"
6'9"
205.6
0.715
-0.003
4.942
0.001 '
K=1.00
P/
T6
160- 140
L2x2x3/16
7'9"
7'9"
236.0
0.715
-0.005
3.673
0.001'
K=1.00
Il/
'17
140-120
L2 1/2x2 1/2x3/16
8'9"
8'9"
212.1
0.902
-0.004
5.738
0.001'
K=1.00
I/
T8
120-100
L212x21/2x3/16
9.9"
919"
236A
0.902
-0.005
4.621
0.001�
K=1.00
li/
T9
100-80
L3x3x3/16
10'9"
10,9"
216.4
1.090
-0.008
6.659
0.001'
K=1.00
V
TIO
80-60
2L2x2x3/16x3/8
11'6"
1IV-
225.0
1.430
-0.030
8.045
0.0041
K=1.00
2L'a' > 66.092 in - 306
T11
60-40
2L2x2x3/16x3/8
12'6"
12'6"
244.6
1.430
-0.026
6.815
0.0041
K=1.00
2L'a'> 71.840 in - 357
T12
40-20
21,212x212x3/16x3/8
13'6"
13'6"
213.6
1.900
-0.032
11.192
0.003'
K=1.00
2L'a'> 77.304 in-408
T13
20-0
2L21/2x2120/160/8
14'6"
14'6"
229.4
1.800
-0.029
9.713
0.003'
K=1.00
2L'a'> 83.030 in-459
1 P" /V. controls
Tension Checks
Leg Design
Data
Tension
Ratio
Section
Elevation
Size L
Lu K11r
A
P.
No.
P.
ft
ft
ft
in'
K
K
�P"
Tl
250-240
2 10,
5' 120.0
3.142
1.862
141.372
0.013'
MxToweP
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
34 of 39 .
B+T Group
Project
Date
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX.- (918) 295-0265
Section
Elevation
Sue
L
L.
KUr
A
P.
rbp"
Ratio
No.
P.
ft
ft
ft
int
K
K
gyp"
T2
240-220
212
20'13/32
68-1/8"
128.2
4.909
26.251
220.893
0.119,
T3
220-200
3
20.13/32
68-1/8"
106.8
7.069
54.723
318.086
0.172'
T4
200 - 180
3 1/4
20'13/32
68-1/8"
98.6
8.296
85.264
373.310
0.2281
T5
180-160
31/4
20'13/32
5'3/32"
74.0
8.296
114.973
373.310
0.308'
T6
160-140
312
20'13/32
5'3/32"
68.7
9.621
148.161
432.951
0.342'
T7
140-120
3 3/4
20'13/32
5'3/32"
64.1
11.045
192.424
497.010
0.387'
T8
120-100
4
20'13/32
5'3/32"
60.1
12.566
244.389
565.487
0.432'
T9
100-80
41/4
20'13/32
5'3/32"
56.6
14.186
296.943
638.381
0.465'
T10
80-60
412
20'13/32
5'3/32"
53.4
15.904
336.485
715.694
0.470'
11
T11
60-40
43/4
20'13/32
5'3/32"
50.6
17.721
389.519
797.425
0.488'
1.
T12
40-20
43/4
20'13/32
5'3/32"
50.6
17.721
442.381
797.425
0.555'
T13
20-0
5
20'13/32
53/32"
48.1
19.635
493.063
883.573
0.558'
1 P„ / r P. controls
Diagonal
Design
Data
Tension
Ratio
Section
Elevation
Size
L
L.
KUr
A
P.
No.
P.
ft
ft
ft
int
K
K
4p"
Tl
250-240
L2x2x3/16
7'9-23/3
3'6-7/8"
73.8
0.431
2.151
18.739
0.115'
2"
101
T2
240-220
L212x212x3/16
10'1-15/
4'11-9/3
79.6
0.571
4.363
24.840
0.176'
16"
2"
T3
220-200
L212x21/2x3/16
11'8-15/
5'8-3/8"
91.4
0.571
5.624
24.840
0226'
16"
T4
200 - 180
L3x3x3/16
13'5-1/4'
66-3/8"
86.3
0.712
7.133
30.973
0.230 '
v
TS
180-160
2L212x212x3/16x3/8
8-2-7/16'
7-7-1/16'
123.9
1.139
9.217
49.549
0.186'
2L'a'> 43.448 in - 97
T6
160 - 140
2L2 1/2x2 120/160/8
9'5-7/32'
8'9-25/3
142.9
1.139
11.873
49.549
0.240'
2
✓
2L'a'> 48.196 in - 126
T7
i40 -120
21,2 12x2 120/160/8
9'10-11/
9'2-27/3
149.4
1.139
16.532
49.549
0.334'
32"
2"
2L'a'>49.677 in-175
T8
120 -100
2L3x3x3/16x3/8
10'8-27/
101-7/3
134.8
1.424
18.592
61.947
0.300'
I
MxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
35 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 5874630
Crown Castle
Kiran
FAX (918) 295-0265
Section Elevation Size L L„ Kt/r A P. gyp„ Ratio
No. P.
ft ft ft in' K K Ap
2L'a'> 56.142 in - 214
T9
100-80
2L3x3x5/16x3/8
12'1"
11'5-15/
154.7
2.311
20.871
100.526
0.208'
16"
2L'a' > 61.049 in - 243
TIO
80-60
2L3x3x3/16x3/8
14'10-7/
147-1/2'
127.2
1.424
26.664
61.947
0.4301
16"
2L'a'> 42A69 in - 307
T11
60-40
2L3x3x3/16x3/8
15'7-15/
15'4-15/
133.7
1.424
27.871
61.947
0.450'
32"
32"
2L'a'> 44.623 in - 358
T12
40-20
2L3x3xl/4x3/8
16'4-27/
16'1-15/
139.5
1.879
29.006
81.726
0.355'
32"
16"
-
2L'a'>46.989 in-409
T13
20-0
2L3x3xl/4x3/8
17'2-15/
16'11-15
146.4
1.879
29.753
81.726
0.364'
32"
/3T'
2L'a'> 49.290 in - 460
' P„ / �P„ controls
'
'Horizontal Desi
h Data Tension
Ratio
Section
Elevation
Size
L
L.
K1/r
A
P.
No.
P.
ft
ft
ft
in'
K
K
6p"
T5
180.160
L2x2x3/16
13'6"
65-5/8"
128.6
0.431
2.649
18.739
0.141'
T6
160-140
L21/2x2 1/20/16
15'6"
7'5-1/2"
117.3
0.571
3.304
24.840
0.133'
T7
140-120
1,300/16
176"
8'5-3/8"
109.8
0.712
4.118
30.973
0.133'
T8
120- 100
L3x3x3/16
19'6"
9'5-1/4"
122.5
0.712
4.991
30.973
0.161'
T9
100-80
L3x3x1/4
21'6"
10'5-1/8'
136.4
0.939
6.074
40.863
0.149'
T10
80-60
2L2 1/2x2 1/2x3/16x3/8
23'
11'3-3/4'
174.5
1.139
6.894
49.549
0.139'
2L'a'> 64.778 in - 280
T11 60-40
2L2 1/2x2 1/2x3/16x3/8
25'
12'3-5/8' 189.7 1.139
7.996
49.549
0.161'
Y
2L'a'> 70.444 in - 331
T12 40 -20
2L2 1/2x2 1/2x3/160/8
27'
13'3-5/8' 205.2 1.139
9.095
49.549
0.184 '
2L'a'> 76.171 in - 397
T13 20-0
2L3x3x3/16x3/8
29'
14'3-1/2' 182.6 1.424
10.186
61.947
0.164'
2L'a'> 81.641 in - 448
' P. / r P„ controls
tnxTower
Job 77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
36 of 39 "
B+T Group
Project
Date
1717 S. Boulder, Suite 300
14:12:19 01/23/19
Client -
Designed by
Tulsa, OK 74119
Phone: (918) 587-4630
Crown Castle
Kiran
FAX.. (918) 295-0265
Top Girt Design
Data
Tension
Ratio
Section Elevation
Size L L„
Kl/r
A P.
OP„
No.
P.
fr
Jt ft
in' K
K
P.
TI 250-240
L2x2x3/16 6' 5'6-1/2"
113.5
0.431 0.161
18.739
0.009,
1 P" / �P" controls
Redundant Horizontal 1 Design. Data Tension
Section Elevation Site L L„ KOr A P. Ratio
No. P.
jt Jt Jt in' K K e.
T10
80-60
2L2x2x3/16x3/8
5'9"
5'6-3/4"
108.2
1.43U
6.896
45.332
U.149'
2L'a'> 31.969 in - 300
Tll
60-40
2L2x2x3/16x3/8
6'3"
6'5/8"
117.7
1.430
7.997
46.332
0.173'
2L'a'>34.782in-351
T12
40-20.
2L2x2x3/16x3/8
6'9"
66-5/8"
127.4
1.430
9.097
46.332
0.196'
2L'a'> 37.656 in - 384
T13
20-0
2L2x2x3/16x3/8
TY
7'1/2"
137.0
1.430
10187
46.332
0.220'
2L'a' > 40.470 in - 453
I P„ / ¢P" controls
Redundant Diagonal 1
Design
Data (Tension)
Ratio
Section
Elevation
Size
L
L.
KI/r
A
P.
4iP.
No.
P.
ft
ft
,Jt
in'
K
K
�P"
TIO
80-60
2L2x2x3/16x3/8
T9-3/4"
7'6-11/1
147.0
1.430
4.684
46.332
0.101'
6"
2L'a'> 43.438 in - 325
Tll
60-40
2L2x2x3/16x3/8
8'2-7/16'
T11-5/1
154.5
1.430
5.247
46.332
0.113 '
6„
Y
2L'e > 45.657 in - 376
T12
40-20
2L2x2x3/16x3/8
8'7-1/4"
84-1/4"
162.5
1.430
5.798
46.332
0.125'
2L'a' > 48.011 in - 411
T13
20-0
2L2x2x3/16x3/8
9'3/16"
8'9-3/32'
170.4
1.430
6.333
46.332
0.137'
2L'a'> 50.340 in - 478
tnxTower
Job
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
37 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone: (918) 587-4630
Crown Castle
Kiran
FAX.- (918) 295-0265
1 P" / ¢P" controls
Redundant Hi 1 Design Data Tension
Section
Elevation
Site
L
L„
Kbr
A
P.
�P,
Ratio
No.
P.
ft
ft
ft
in'
K
K
�P"
T10
80-60
L21/2x212x3/16
519"
5'9"
88.7
0.902
0.036
29.225
0.001'
Tll
60-40
L2 1/2x2 1/2x3/16
6'3"
65"
96.4
0.902
0.029
29.225
0.001'
T12
40-20
L212x212x3/16
6'9"
69"
104.1
0.902
0.032
29.225
0.001'
kl
T13
20-0
L21/2x212x3/16
TY
TY
111.8
0.902
0.026
29.225
0.001'
1 P„ / r P. controls
Inner Bracing Design Data Tension
Section Elevation Size L L. KUr A P. �P„ Ratio
No. P.
ft
ft
ft
in"
K
K
V.
T10
80-60
2L2x2x3/16x3/8
11'6"
11'6"
223.7
1.430
0.018
46.332
0.000,
2L'a' > 66.092 in - 306
Tll
60-40
2L2x2x3/16x3/8
12'6"
12'6"
243.1
1.430
0.014
46.332
0.000,
Y
2L'a'> 71.840 in-357
T12
40-20
2L212x21/20/160/8
13'6"
13'6"
208.2
1.800
0.017
58.320
0.000'
2L'a'> 77.304 in - 408
T13
20-0
2L21/2x21/20/160/8
14'6"
14'6"
223.6
1.800
0.012
58.320
0.000'
2L'a'> 83.030 in-459
i P„ / r P" controls
Section Capacity Table
Section
Elevation
Component
Size
Critical
P
op.11-
%
.Pass
No.
ft
Type
Element
K
K
Capacity
Fail
T1
250-240
Leg
2
1
-3.633
51.751
7.0
Pass
12
240 -220
Leg
2 1/2
19
-30.407
70.833
42.9
Pass
T3
220 - 200
Leg
3
40
-62.513
144.956
43.1
Pass
T4
200 -180
Leg
3 1/4
61
-97.541
192.479
50.7
Pass
T5
180 - 160
Leg
3 1/4
82
-132.221
262.734
50.3
Pass
T6
160 - 140
Leg
3 12
121
-173.775
321.973
54.0
Pass
tnxTOwer
Job
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
Page
38 of 39 4'
B+T Group
Project
Date
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Client
Designed by
Tulsa, OK 74119
Phone: (918) 5874630
Crown Castle
Kiran
FAX.. (918) 295-0265
Section
Elevation
Component
Size
Critical
P
oP,nm.
%
Pass
No.
ft
Type
Element
K
K
Capacity
Fail
T7
140 -120
Leg
3 3/4
160
-227.087
386.416
58.8
Pass
T8
120 -100
Leg
4
199
-287.506
455.948
63.1
Pass
T9
100-80
Leg
4 1/4
238
-350.249
530.481
66.0
Pass
TIO
80-60
Leg
41/2
277
-397.527
609.947
65.2
Pass
T11
60 - 40
Leg
4 3/4
328
-461.048
694.293
66A
Pass
T12
40-20
Leg
43/4
379
-524.438
694.293
75.5
Pass
T13
20-0
Leg
5
430
-587.351
783.476
75.0
Pass
T1
250-240
Diagonal
L2x2x3/16
7
-2.270
16.441
13.8
Pass
15.1 (b)
T2
240-220
Diagonal
L212x2120/16
22
-4.620
18.705
24.7
Pass
26.6 (b)
T3
220-200
Diagonal
L212x212x3/16
43
-5.850
15.126
38.7
Pass
T4
200 - 180
Diagonal
L3x3x3/16
64
-7.380
19.745
37.4
Pass
40.9 (b)
T5
180 - 160
Diagonal
2L2 12x2 12x3/16x3/8
86
-9.781
32.930
29.7
Pass
T6
160- 140
Diagonal
2L2 1/2x2 1/20/160/8
125
-12.554
27.196
46.2
Pass
T7
140-120
Diagonal
2L212x212x3/16x3/8
164
-17.189
22.693
75.7
Pass
T8
120 -100
Diagonal
2L3x3x3/16x3/8
203
-18.950
32.178
58.9
Pass
T9
100-80
Diagonal
2L3x3x5/16x3/8
242
-21.330
45.167
47.2
Pass
T10
80-60
Diagonal
2L3x3x3/16x3/8
281
-27.609
52AOO
52.7
Pass
76.4 (b)
T11
60 -40
Diagonal
2L3x3x3/16x3/8
332
-28.755
49.847
57.7
Pass
79.8 (b)
T12
40 -20
Diagonal
2L3x3xl/4x3/8
383
-29.733
63.962
46.5
Pass
62.3 (b)
T13
20-0
Diagonal
2L3x3xl/4x3/8
434
-30.387
59.676
50.9
Pass
63.9 (b)
T5
180- 160
Horizontal
L2x2x3/16
85
-2.649
5.536
47.9
Pass
T6
160 - 140
Horizontal
L2 12x2 1/20/16
124
-3.304
8.292
39.9
Pass
T7
140-120
Horizontal
L3x3x3/16
169
4.118
11.323
36.4
Pass
T8
120- 100
Horizontal
L3x3x3/16
202
4.991
9.073
55.0
Pass
T9
100- 80
Horizontal
L3x3xl/4
241
-6.074
9.687
62.7
Pass
TIO
80-60
Horizontal
2L2 1/2x2 1/20/160/8
280
-6.894
16.668
41A
Pass
TH
60-40
Horizontal
2L21/2x2120/160/8
331
-7.996
14.124
56.6
Pass
T12
40-20
Horizontal
2L2 1/2x2 120/160/8
382
-9.095
12.100
75.2
Pass
T13
20-0
Horizontal
2L3x3x3/16x3/8
433
-10.186
17.817
57.2
Pass
TI
250 - 240
Top Girt
L2x2x3/16
6
-0.206
7.543
2.7
Pass
T10
80 - 60
Redund Horz 1
2L2x2x3/16x3/8
282
-6.896
33.446
20.6
Pass
Bracing
T11
60 - 40
Redund Horz 1
2L2x2x3/16x3/8
333
-7.997
29.757
26.9
Pass
Bracing
T12
40 -20
Redund Horz 1
2L2x2x3/16x3/8
402
-9.097
25.730
35.4
Pass
Bracing
T13
20-0
Redund Horz1
2L2x2x3/16x3/8
435
-10.187
22.329
45.6
Pass
Bracing
'T10
80-60
Redund DiagI
2L2x2x3/16x3/8
309
-4.684
19.419
24.1
Pass
Bracing
T11
60-40
Redund DiagI
2L2x2x3/16x3/8
360
-5.247
17.599
29.8
Pass
Bracing
T12
40-20
Redund Diag1
2L2x2x3/16x3/8
411
-5.798
15.933
36.4
Pass
Bracing
T13
20 -0
Redund Ding 1
2L2x2x3/16x3/8
462
-6.333
14.506
43.7
Pass
Bracing
TIO
80-60
Redund Hip
L21/2x212x3/16
327
-0.039
13.951
0.3
Pass
Bracing
T11
60-40
Redund Hip
L212x212x3/16
378
-0.034
11.808
0.3
Pass
Bracing
T12
40-20
Redund Hip
L21/2x212x3/16
429
-0.039
10.124
0.4
Pass
Bracing
T13
20-0
Redund Hip
L21/2x21/20/16
480
-0.033
8.775
0.4
Pass
Bracing
` tnxTower
J ob
Page
77034.008.01 - FL WEST FORT PIERCE, FL (BU# 813812)
39 of 39
Project
Date
B+T Group
1717 S. Boulder, Suite 300
14:12:19 01 /23/19
Tulsa, OK 74119
Client
Designed by
Phone. (918) 5874630
Crown Castle
Kiran
FAX.. (918) 295-0265
Section
Elevation
Component
Size
Critical
P
opmta.
%
Pass
No.
ii
Type
Element
K
K
Capacity
Fail
T5
180-160
InnerBracing
L2x2x3/16
96
-0.003
5.084
0.1
Pass
T6
160-140
Inner Bracing
L2x2x3/16
133
-0.005
3.857
0.2
Pass
T7
140-120
Inner Bracing
L212x21/20/16
174
-0.004
6.025
0.2
Pass
T8
120-100
Inner Bracing
L21/2x212x3/16
213
-0.005
4.852
02
Pass
T9
100-80
Inner Bracing
L3x3x3/16
252
-0.008
6.992
0.2
Pass
T10
80 -60
Inner Bracing
2L2x2x3/16x3/8
306
-0.030
8.447
0.4
Pass
Tll
60 -40
Inner Bracing
2L2x2x3/16x3/8
357
-0.026
7.155
0.4
Pass
T12
40 -20
Inner Bracing
21,2 I/W 120/160/8
408
-0.032
11.751
0.3
Pass
T13
20-0
Inner Bracing
2L212x21/2x3/16x3/8
458
-0.027
10.199
0.3
Pass
Summary
Leg (T12)
75.5
Pass
Diagonal
79.8
Pass
(TI1)
Horizontal
752
Pass
(T12)
Top Girt
2.7
Pass
(TI)
Redund
45.6
Pass
Hons 1
Bracing
(T13)
Redund
43.7
Pass
Diag I
Bracing
(T13)
Redund Hip
0.4
Pass
1 Bracing
(T12)
Inner
0.4
Pass
Bracing
(T11)
Bolt Checks
79.8
Pass
RATING =
79.8
Pass
Program Version 8.0.5.0
APPENDIX B
BASE LEVEL DRAWING
V.m i
vi 0 w
yie ro
n/n' m IQ
iu
R) I`�lU I
E
rams/ wM
i n/n• a
BUSINESS UNIT : 813812
APPENDIX C
ADDITIONAL CALCULATIONS
a
PROJECT
813812 - FL WEST FORT PIERCE FL
SUBJECT
475131 Re, 0
DATE
01/23/19
TIA-222-H
Redundant Connection Analvsis
J13 B+T GRP
1717 S. Boulder, Suite 300
Tulsa, OK 74119
(918) 587-4630
BBTPro1.No, 7/034.008.01
Elevason Member Size
Member Block Shear
Tearing 8 Member Bead
Bob Shear
% Capacity
iPn
Loatl
Rn
Load
Rnv
Load
Redundant Horizontal (1) Design Data (Compression)
80-60 2L24z3ll6x3/8
26.10
6.896
27.61
6.90
26.4%
Pass
60-40 21-21Qx3/16"it
26.10
7.997
27.61
8.00
30.6%
Pass
40-20 2L2tQx3/16x3/8
26.10
9.097
27.61
9.10
34.9%
Pass
20-0 2L24x3/16x3/8
26.10
10.187
27.61
10A9
39.0%
Pass
Redundant Diagonal (1) Design Data (Compression)
'
80-60 2L2x2x3/16x3/8
26.10
4.684
27.61
4.68
17.9%
Pass
60-40 2L2DQx3/160/8
26.10
5.247
27.61
5.25
20.1%
Pass
40-20 2L24x3/l6x3/8
26.10
5.798
27.61
5.80
22.2%
Pass
20-0 2124x3/16x3/e
26.10
6.333
27.61
6.33
24.3%
Pass
Redundant Hip (1) Design Data (Compression)
80-60 L212410016
13.05
0.039
13.81
0.04
0.3%
Pass
60-40 L21241/2x3/16
13.05
0.034
13.81
0.03
0.3%
Pass
40-20 L211W 106116
13.05
0.038
13.81
0.04
0.3%
Pass
20-0 L21/2x2 M20116
13.05
0.033
13.81
0.03
0.3%
Pass
Redundant Horizontal (1) Design Data (Tension)
80-60 212)(WI164/8
15.75
6.90
22.19
6.896
27.61
6.90
43.8%
Pass
60-40 21.2441160/8
15.75
8.00
22.19
7.997
27.61
8.00
50.B%
Pass
40-20 212)Q13/16418
15.75
9.10
22.19
9.097
27.61
9.10
57.8%
Pass
20-0 2L24K3/16x3/8
15.75
10.19
22.19
10.187
27.61
10.19
64.7%
Pass
Redundant Diagonal (1) Design Data (Tension)
80-60 2L2x2x3/16x3/8
15.75
4.68
22.19
4.684
27.61
4.68
29.7%
Pass
60-40 21241C3/16x3/8
15.75
5.25
22.19
5.247
27.61
5.25
33.3%
Pass
40-20 21L24Y3/16x3/8
15.75
5.80
22.19
5.798
27.61
5.80
36.8%
Pass
20-0 2L2x2x3/16x3/8
15.75
6.33
22.19
6.333
27.61
6.33
40.2%
Pass
Redundant Hip (1) Design Data (Tension)
80-60 L212412X3/16
9.91
0.04
11.09
0.036
13.81
0.04
0.4%
Pass
60-40 L212412X3/16
9.91
0.03
11.09
0.029
13.81
0.03
0.3%
Pass
40-20 L212412x3/16
9.91
0.03
11.09
0.032
13.81
0.03
0.3%
Pass
20-0 L212IQ 1/2x3H6
9.91
0.03
11.09
0.026
13.81
0.03
0.3%
Pass
Ccuphle
Project Information
BU # 813812
Site Name FL WEST FORT PIERCE; FI
Order # 475131, Rev 0
Jower Information
TowerTypel Self Support
TIA-222 Rev] H Q Apply TIA-222-H Section 15.5
,Applied Loads
Comp. Uplift
Axial k 617.00 518.00
Shear k 74.00 64.00
Anchor Rod 1 Data
Quantity:
6_.
Diameter (in):
2.25
Material Grade:
A36
Grout Considered:
No
la, (in):
21.
Eta Factor, 9:
0i5-
Thread T e:
N-Included
Confi uration:
Symmetrical
,Anchor• 1 1 Results
Axial, Pu c kips
102.83
Shear, Vu (kips)
12.33
Moment, Mu (kip -in)
-
Axial Cap., (pPn c(kips)_117.00
Shear Cap., 4)Vn (kips)
35.10
Moment Cap., (�Mn (kip -in)
-
Stress Rating
95.5%
Fy=36 ksi Fu=58 ksi
Not Considered, lar<=1(d)
Pass
CClplate - version 3.5.0 Analysis Date: 1/23/2019
PROJECT 77034.008.01 - FL West Fort Pierce, FL r
SUBJECT Foundation Comparison B+T GRP
1717 S. Boulder, Suite 300
DATE 01/23/19 PAGE 1 OF 1 Tulsa, OK 74119
(918)587-4630
Initials
SST
Factored TnxTowers Reactions
Down =
617 k
Uplift =
518 k
Un-Factored Original Design Reactions
Down =
627.5 k
Uplift =
542.1 k
Percent Capacity
Down =
69.4% Pass
Uplift =
67.4% IPass
j
ASCE
AMGUMS ORYU MLBJGNHLS
Address:
No Address at This
Location
ASCE 7 Hazards Report
Standard: ASCE/SEI 7-10 Elevation: 18.55 ft (NAVD 88)
Risk Category: II Latitude: 27.445706
Soil Class: D - Stiff Soil Longitude:-80.412942
I
t
!
—aed
Wind
Results:
Wind Speed:
10-year MRI
25-year MRI
50-year MRI
100-year MRI
Data Source:
Date Accessed:
a
157 Vmph
87 Vmph
105 Vmph
117 Vmph
129 Vmph
ASCE/SEI 7-10, Fig. 26.5-1A and Figs. CC-1—CC-4, incorporating errata of
March 12, 2014
Tue Jan 22 2019
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear
interpolation between contours. Wind speeds are interpolated in accordance with the 7-10 Standard. Wind speeds
correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability =
0.00143, MRI = 700 years).
Site is in a hurricane -prone region as defined in ASCE/SEI 7-10 Section 26.2. Glazed openings shall be protected
against wind-borne debris as specified in Section 26.10.3.
Mountainous terrain, gorges, ocean promontories, and special wind regions should be examined for unusual wind
conditions.
httos,//asce7hazardtool online/ Page 1 of 3 Wed Jan 23 2019
ASCE
AM90CM SOOM DF CR rNGIN9M
Seismic
Site Soil Class:
D - Stiff Soil
Results:
SS :
0.057
St
0.029
Fa
1.6
F
2.4
SMS
0.091
SM1 :
0.07
Seismic Design Category A
0.10 MCEg _Response Spectrum, _
0.09��g
0.08 I `
0.07 t
0.05
0.05
0.04
0.03
0.02
0.01
0 1 2
Sa(9) vs T(S) 5 6 7 8 9
SDS
Sol
TL
PGA:
PGA M
F PGA
la :
0.07
0.0
0.0
0.0
0.0
0.0
0.0
0.061
0.047
8
0.027
0.043
1.6
1
Desiqn Response Spectrum
Sa (9) vs T(s)
Data Accessed: Tue Jan 22 2019
Date Source: USGS Seismic Design Maps based on ASCE/SEI 7-10, incorporating
Supplement 1 and errata of March 31, 2013, and ASCE/SEI 7-10 Table 1.5-2.
Additional data for site -specific ground motion procedures in accordance with
ASCE/SEI 7-10 Ch. 21 are available from USGS.
https:/Iasce7hamrdtool.online/ Page 2 of 3 Wed Jan 23 2019
ASCE
AMMM GOCIE FY OF COL ENGWOM
Ice
Results:
Ice Thickness:
0.00 in.
Concurrent Temperature:
25 F
Gust Speed:
30 mph
Data Source:
Standard ASCE/SEI 7-10, Figs. 10-2 through 10-8
Date Accessed:
Tue Jan 22 2019
Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys
and gorges may exceed the mapped values.
Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds,
for a 50-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain.
Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice
thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may
exceed the mapped values.
The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided 'as is" and without warranties of
any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers;
or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from
reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability,
currency, or quality of any data provided herein. Any third -party links provided by this Tool should not be construed as an endorsement,
affiliation, relationship, or sponsorship of such third -party content by or from ASCE.
ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent
professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such
professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard.
In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors,
employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential
damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by
law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data
provided by the ASCE 7 Hazard Tool
https�//asce7hamrdtool.online/ Page 3 of 3 Wed Jan 23 2019