EVALUATION REPORT
Polyglass USA, Inc. Evaluation Report P12060.02.09-R24
1111 West Newport Center Drive FL5259-1128
Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009
(954) 233-1230 Revision 24: 01/24/2018
SCOPE:
This Evaluation Report is issued under Rule 61G203 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the & Edition (2017) Florida Building Code sections noted
herein.
DESCRIPnON: Polyglass Roof Underlayments
LAeEuNG: labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nleminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility lodation(s). NEMOIetc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADvEignsEMENr: The Evaluation Report number preceded by the words "NEMO)etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then It shall be done In its entirety. '
INsPEatoN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for Inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by: Ay�,mqa,a
gF°3 1..:rZory
=
Robert J.M.Nieminen,P.E ; .,°a': ;�'.T` The facsimile seal appearingwes authorized by Robert Nieminen,
Florida Registration No. 59166, Florida DCA ANE190 ya °-A^'g�4ygs P.E. an 01124/201E. This does not serve as an electronically
5={b atis"e. signed dowmeft
CERnnrATION OF INDEPENDENCE:
1. NEMDIetc. does not have, nor does it Intend to acquire or will it acquire, a financial interest In any company manufacturing or
distributing products it evaluates.
2. NEMOIair— is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nleminen, P.E. does not have nor will acquire, a financial Interest in any company manufacturing or distributing products for
which the evaluation reports are being Issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest In any other entity involved in the approval process of the
product.
S. This Is a building code evaluation. Neither NEMOI etc. nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used fur permitting or design guidance unless retained
specifically for that purpose
ROOFING COMPONENT EVALUATmN,.
1. SCOPE:
Product Category: Roofing
Sub -Category: Undedayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 6th Edition (2017) Florida Building Code through testing In accordance with the following Standards.
Compliance Is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. SrANDAROS:
Section
Prop env
Standard
year
1504.3.1
Wind Uplift
FM 4474
2011
1504.3.1
Wind Uplift
U11897
2012
1507.2.3 / 1507.L7
Physical Properties
ASTM D226
2009
1507.2.4 / 1507.L1, 1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSAIM April 2012
2012
1507AL2
Physical Properties
ASfM D6164
2011
1507.1L2
Physical Properties
ASTM D6222
2011
TAS 110
Accelerated Weathering
ASTM D4798
2021
3. REFERENCES:
Entity
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/22/20DD
PRI (TSr5978)
Physical Properties
PRI01111
04/08/20M
PRI M75878)
Physical Properties
PUSA-005-02-01
02/31/2002
.PRI CM 5878)
Physical Properties
PUSH-013-02-01
12/23/2002
PRI (TSTSIDE)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI CM 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST587S)
Physical Properties
PUSA-018-02-01
07/14/2003
PRI (TST587S)
Physical Properties
PUSA-028-02-01
07/13/2005
PRI (TST5878)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI(7ST5878)
Physical Properties
PUSA-035-02-01
09/29/2005
PRI MT 5878)
Physical Properties
PUSA-USS42-02
12/10/2007
PRI UST 5878)
Physical Properties
PUSM061-02-02
01/28/200H
PRI (TST 5878)
Physical Properties
PUSA-076-02-01
02/22/2008
PRI MS878)
Physical Properties
PUSA-083-02-01
04/14/2008
" PRI(TST5878)
Physical Properties
PUSA1088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
1X201-17A
04/01/2008
MTI (757 2508)
Physical Properties
RX14EBA
01/29/2009
ERB OW 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERB (TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERB (TST 6049)
Wind Uplift
22776.05.02
01/16/2003
ERB (T5j 6D49)
Physical Properties
02200.07.03
07/14/2003
ERB (TST 6049)
Wind Uplift
P1740.0L07
01/04/2007
ERB (TST 6049)
Physical Properties
P5110.04.07-1
04/12/2007
ERB (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD=6049)
Physical Properties
.P13450.08.09
08/13/2009
ERB MT 6049)
Wind Uplift
P30540.11.09-R1
11/30/2009
ERB M6049)
Physical Properties
P11030.11.09.1
11/30/2009
ERB(M 6049)
Wind Uplift
P71030.11.09-2
11/36/2009
ERB (TST6049)
Physical Properties
P11030.11.09-3
11/30/2009
ERB (TST 6049)
Physical Properties
P33360.06.10
06/25/2010
ERD(M76049)
Physical Properties
P33370.03.11
03/02/2021
ERB (TST 6049)
Physical Properties
P33370.04.11
04/26/2011
ERB UST 6049)
Physical Properties
P37300.10.31
10/19/2011
Evaluation Report P32060.02A9-1124
NEMO Err- LIL
o,rWM QfAYM"affWnx32Q55.
a-EMTION(2o17) FBC NO&HVHZEVALUATION
FL5259M
Revision 24:01/24/2018
Poiyglass Roof Underlayments:
(954) 233-t230
Page 2 of 14
4.
Entity
ERD (TST 6D49)
ERD (M 6049)
ERD (TSr W49)
ERD (TST 6049)
ERD (TSr 6049)
ERD (TST 6049)
ERD (Wfi%9)
ERD OW 6049)
ERD (m6049)
ERD (TST 6049)
ERD (TST 6D49)
ERD (TST 6049)
ERD (W 6649)
ERD (TST 6049)
ERD (TST 6D49)
ERD (M 6049)
ERD (TST 5049)
ERD (TST 6049)
ERD OW 6049)
ERD (TST GD49)
ERD (TS76049)
ERD (TST 6049)
ERD MT 6049)
ERD (TST6049)
ERD (TSr6049)
ERD (TST6049)
ERD (TS76049)
ERD tW 6049)
ERD CYST 6049)
ICC,ES (EVL 2396)
Miami -Dade (CER 1592)
Polyglass USA
PolygMss USA
Polyglass USA
UL, LLC. (QUA9625)
PRODUCT DESCRIPDON:
Examination .
Physical Properties
Physical Properties
Physical Properties
Wind Uplift
Physical Properties
Wind Uplift
Wind Uplift
Wind Uplift
Wind Uplift
Wind Uplift
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
wind Uplift
Physical Properties
wind Uplift
Physical Properties
Physical Properties
Physical Properties
ISCCompliance
HVHZ Compliance
Manufacturing Affidavit
PA Affidavit
Materials Affidavit
Quality Control
Reference
P40390.08.12-1
KIN190.08.12-2
C41420.09.12-3
P396=03.13
P45370.04.13
P1738.02.07-R2
11757.04.01-1-R3
P41630.08.13
P117SLOS.03-Ri
P217SLIL03-RI
P45270.0&3.4
6MO.07.14.1
6020.09.24-2
6020.09.14-3
6020.09.14-4
6020.0914-5
602D.09.14-6
P46520.10.24
P43290.10.14
PLYG-SC7550.03.15
P40390.04AS
P44360.10.14-R1
PLYG-SC6080.05.15-1
PLYG-SC8905.0516-1
PLYG-SC808f1.07.16
PLYG-SC12025.10.16
PLYG.SG13040.12.16
PLYG-SM1900.03.17
PLYG-SC12115.08.17
ESR-1697
NOA 14-0717.08
Products Current
Mule -Hide Cross L%
P0lystic k SA Compound
Service Confirmation
4.L1 Elastobase Is a fiberglass reinforced, 58S modified bitumen base sheet
4,L2 Elastobase Pisa polyester -reinforced, SB.S modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet
4.L4 Polygbm APP Base is a fiberglass -reinforced, APP modified bitumen base sheet
ONEMOletc.
Date
08/06/2012
OBIU712032
09/11/2012
03/04/2013
04/26/2013
04/29/2013
04/30/2013
08/06/2013
11/26/2013
W26/2013
05/12/2014
C9/08/2014
09/OS/2024
09/08/2014
09/08/2024
09/08/2024
09/08/2014
10/03/2014
10/17/2014
03/24/2015
04/03/2015
OSA8/20ss
05/20/2015
05/17/2016
07/16/2015
10/12/2016
12/27/2016
03/20/2017
09/09/2017
11/02/2014
01/22/20Ls
02/18/2009
03/01/2008
08/18/2012
Exp.10/05/2018
4.2.1 Polystiek MTS or Polystlek MTS PLUS is a nominal 60-mll thick rubberized asphalt waterproohng memorane, glass
fiber reinforced, surfaced with polyolefinie film surface; meets FRSA/TRI April 2022.
422 Polysdck IR Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
42.3 Polystick TU Pius Is a nominal 80•mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012.
NWO ETr.LLC. Evaluation Report P12060.02D9-1124
QUWx2WOAurlmrRokbnd324W 6'a EDMON(2017) FRC NON-UVRL EVAWATION FL5259-M
Potygtass Roof UndedaymeMs; 19%] 233-1230 Revision 24: M/24/2018
Page 3 of 14
ONEMOJetc.
42.4 Polystick TU P Is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface; meets FRSA/TRI April 2012.
4.2.S Polystkk TU Max Is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m= polyester
fabric surface; meets ASTM D1970 and FRSA/TRI April 2012.
4,2.6 Potyflex SAP,. Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester.
reinforced, APP modified bitumen cap sheets; meet FRSA/TRI April 2012.
4.23 Polystkk Dual Pro`• is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyesterfabricsurrace; meets ASTM D3970.
4.2.8 Polystick Tile ProM is a nominal 60-mill thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyesterfabricsurface; meets ASTM 01970 and FRSA/TRI April 2012.
4.2.9 Polystirh MU-X is a nominal 54-mil thick. dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D2970 (See Section
5.8).
4.3.1 Elanciflex 6 TU is a polyester -reinforced, modified bitumen the underlayment composed of a. sand -surfaced SBS
modified bitumen back -side and granule -surfaced APP modified bitumen topside. Elastoflex 6 1 U is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the `Single Ply System" from FRSA/rRi April
2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheer in the 'Two Ply
System" from FRSA/iRl April 2012 (04-12) beneath mechanically fastened or adhered the roof systems.
4.32 Elastoflex S6 6 and Elastoffex 56 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164.
Elastoflex S6 6 and Elastoflex S6 G FR are for use as an alternate to "Mineral SurfaceeRoll Roofing" (ASrM D6380,
Gass M) in the "Single Ply System" from FRSA/Ml April 2012 (04-12) beneath mechanially.fastened tile roof systems.
Elastoflex S6 G Is for use as an alternate to Hot Asphalt applied "Cap Sheer in the "Two Ply System" from FRSA/rRI
April 2012 (04-12) beneath mechanically fastened or adhered file roof systems. Elastoflex S6 G FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet' in the 'Two Ply System" from FRSAITRLApril 2012 (04-12) beneath
mechanically fastened tile roof systems.
4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM 06222.
Polyflex G Is for use as an alternate to Heat Applied "Cap Sheer in the "Two Ply System" from FRSAfM April 2012
(0442) beneath mechanically fastened. or adhered tile roof systems. Polyflex G FR Is for use as an alternate to Heat
Applied "Cap Sheer in the "Two Ply System' from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the
roof systems.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMOletc nor Robert Nleminen, P.E. are, In any way, the Designer of
Record for any project on which.this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ
53 Fire Classification Is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Undedayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. if not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering..
NEMo etr, u.C. Evaluation Report P32060.02A9-R24
cyWoteufAetaonrenenM455 eEDMON 12022) FHC NON•NVHZEVAWATION Revlsion?A: 01/24/2018
Polyglm Roof underieyments; (95e) 233.1210
Page 4 of 14
ONEMO etc.
5.5 Mlowible Roof Covers:
�A
Undedayment
Asphalt Shingles
Na"nIlle
Foam -On Ylle
metal
woad Shakes
& Shingles
slate
Elaslabase
Yes
Yes
hasp She lnzplyspumj
Yes
(BnasheetIn2-olysV0,,m)
Yes
Yes
Yes
Elastobase p
Yes
Yes
MmShmjn2-ptV+namj
yes
(avx5heerin2-plyws )
Yes
Yes
Yes
Polyeass G2 Base
No
Yes
(gam Slx:etln2-pNsysmm)
Yes
loam shretin2-pNrysmm)
NO
No
No
Falyglass AFF) Base
No
Yes
Yes
No
No
No
Po[Wck NITS a MTS PWS
Yes
Yes
No
Yes
Yes
Yes
PoWckIR-Xe
Yes
No
NO
No
Yes
Yes
PolystidcTU P
No
Yes
Yes (See 5.5-11
No
No
No
PoWdcTUPlus
Yes
Yes
Yes (sees-1.1)
Yes
yes
Yes
PolystickTUMax
No —
Yes
Yes (See55.1)
Yes
No
No
PoIy0dcDualPro
Yes
No
No
Yes
Yes
Yes
PoN5ti&THePro
Yes
Yes
Yes (See 53.11
Yes
Yes
yes
PdystickMU-X
Yes
No
No
Yes
Yes
Yes
Elastoflex 56 G
Y.
Yes
Yes (See 5.5.1)
No
Yes
Yes
_Yes
klastallex S5 G FR
Yes
Yes
No
No
iw--
ElastallEx GTU
Yes
Yes
Yes (see 5.S_1)
No
Yes
Yes
PaWexG
Yes
Yes
Yes (See 551)
No
Yes
Yes
Pow"GFR
Yes
Yes
No
No
Yes
Yes
PcNfIexSAPorSAPFR
Yes
Yes
Yes (See S.S.
No
—yes
Yes
NluleHIde SA-APP Cap Sheet
orSa-APP cap Sheet IFR)
Yes
Yes
Ym (Sea55.1)
No
Yes
Yes
S.&J "Foam -On TileP is limited to use of the following Approved tile adhesives / underlayment combinations.
7777��..
Ile PERIAYMENICIm qloiw�
Florlda Product Underiallnuents
Adhesive
Approval
DAP Foam Touch 'n Sea[ StannBond Roof
FL14506
PolystickTU Plus, PoWckTU Max
Tile Adhesive
Dow'nlelilondn
FL22525
Poiystick Tu P, PclystickTU Plus, Polyffex SAP or Tile Pro
polystick TU p, polysfick TU Plus, Polystick TU Max, Polysticknia Pro,
ICP Adhesives Polyseto AH-160
FL6332
ElasWflex G TU, Ejastofea S6 6, Polyflex G, Polyflex SAP, POW" SA Cap FR.
L
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polystidc TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
po
ICP Adhesives Polyset" RTA-I
276
FL6276
Elestoflex G TU, Elastaflex 56 G, PoWm 6, Polyflex SAP, PDJYHEX SA Cap K
1!1 C
MZI I=Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Refer to We Manufacturer's or Adhesive Manufacturer's Florida Product Approval far Overturning Moment Resistance Performance
NEMO ETC, LLC.
Evaluation Report P12060.0209-R24
FL5259-P2B
eEDMON(2G17)FBCNON4WHZEVAWATlON Revision 24:01/24/2018
PoWass Roof UndedayaneaW (954) 233-1230 Page 5 of 14
ONEMOletc.
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Decic
Polystick (all variations), Dual Pro, Tile P% Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR) self -adhered to:
D New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, unprlmed OSB; ASTM D41 primed OSB, Southern Yellow Pine; ASTM D42 primed
Southern Yellow Pine, ASTM D41 primed structural concrete; Huber Engineered Woods '21P System Panels
(designed and installed to meet wind loads for project).
Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should he cleaned of all dirt and dehrk prior to application of Polystick membranes.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
D ASTM D41 primed structural mnati .
Polyflex G or Polyflex G FR torch -applied to:
D ASTM D41 primed structural concrete.
5.6.2 Band-talnsulation:
Polystick (all variations), Polyflex SAP or SAP Fit, Mule -Hide SA-APP tap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
D ASTM C12g6, Type 11, Gass 1 polyisccyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime, arSECUROCK Gypsum -Fiber Roof Board.
Elastoflex GTU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK Gypsum -fiber Roof Board.
Polyflex G or Polyflex G FR torch -applied to:
D ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For Installation under mechanically attached prepared roof coverings, Insulation shall be attached per minimum
requirements of the prepared roof covering manufacturers Product Approval. For installations under foam -on tile
systems, Insulation attachment shall be designed by a qualified design professional and Installed based on testing of
the insulation/underlayment system in accordance with FBC Section 3.50431.
5.63 Bond to Mechanically Attached Base Laver.
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
D ASTM D226, Type or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base.
Elastoflex G TU, Elastoflex S6 G or Elastoflex SG G FR in hot asphalt to:
D ASTM D226, Type I or II felt; Elastabase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex GFR torch -applied to:
D Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam -an file systems, base layer shall be attached per minimum
requirements ofFRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 15043.1.
NEMO ETC, U.C. Evaluatlon Report P12060.02.04-R24
Certyi4 VfA.thwmtbeMOS a"EDMON(2017)FOCNONi1VRZEVAWAMON F `�-i2`'9'RZB
pdvgt 59 Raof Umierlaymears; ism) 233-1230 Rev1s1m 24: W24/201a
Page 6 cf 14
ONEMOletc.
5.6.4 Wind Resistance for Underlavment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all undedayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure Is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 15049 has already been applied). Refer to FRSA/iRI April 2012 (04-
12), Appendix A, Table >A or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure =-90osF.
Deck Min.35/324neh plywood to meet project requirements to satisfaction of Authority HavingJurisdicdon.
Primer. None
Use Ply: (Optional) Polystick MTS or Polystick MTS PLUS, seH-adhered.
Underiayment: Polystick TU P, PalystickTU Plus, PolyAck TU Max, Polyflex SAP, Poyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self-
adhered.
#2 Maximum Design Pressure - -97.5 osf.
Deck: MIn 25/324ndi plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Undedaymem: PoWck TU P,Polystick TU Plus, Polystle kTu Max, Polyilex SAP, Polyflex SAP FR, Mule -Hide SA•APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
136'ring shank nails through 32 ga., 1-SW illametertin caps spaced 12-Inch o.c.
#3 Maximum DEsum Pressure =-105 oaf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer WB-3000
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlaymem: Polystick TU P, PoWck TU Plus, Polystiek TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), selfadhered and back -nailed within the selvedge edge side laps using 12 ga. x
2W ring shank nails through 32 ga.,1-5/g' diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure --135 Bsf:
Deck: Min.15/324nch plywood to meet project requirements to satisfaction of Authority Havinglurisdiction.
Primer. lOptlonal) PG100 orASrM D42
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, selfadhered.
Joints: Min. 4-Inch wide strips of Elastoflex SA-V over all plywood joints
Undedayment: Polystick TU'P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, PoWec.SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP. Cap Sheet (FR), selfadhered.
#5 Maximum Design Pressure=-315 tisf•.
'Deck: - Structural concrete to meet pmject requirements to satisfaction of Authority Having Jurisdiction.
Primer. PG300 or ASTM D41
Base Ply. (Optional) Polystidk MTS or PoWck MTS PLUS, self -adhered.
Underiaymehth Polystick TU P, Polystick TU Plus, Polystick: TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR,, Mule -Hide SA-APP Cap
Sheet and Mule-Hlde SA -ARP Cap Sheet (FR), selfadhered.
#6 maxim uinDeslanPressure = -MS
pAf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction..
Primer. PG100 or ASTM D41
UndedaymenC Elastoflex G TU orElastoflexS6 G, applied in full mapping of hot asphalt or Polyflex G, torch -applied.
#7 Maximum Design Pressure =-30Attsf*
Deck: Min 15/32-Inch OSB to meet project requirements to satisfaction of Authority Having lurisdiction.
Base Sheet: Elastobase or Mule -Hide Nall Base (poly -film top surface)
Fasteners: 1t ga. x 1:75-Inch bngx 3-inch head diameter round metal cap nails
.Spacing: 64nch o.c at the 3-inch wide side laps and 64ndh o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Palyetidk MTS or Polystick MIS PLUS, self -adhered.
Underiayment: Polystick TU P, PolysddkTU Plus, Polysttck TU Max, Polyflex SAP, Potyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP. Cap Sheet (FR), self -adhered.
NEMO EIS U.C. Evaluation Report P32060.(Z094M
@,affmh OfAuthoMatim 0=40 do ERMON (2017) F13C NON-HVHZ EVALUATION FL3299'11211
Porygla8 Roof underiaya mts: (964) Z33-lao Revision 24: M/Z4/Z019
Pagel of 14
ONEMOJetc.
#8 Max)murnDesignPressure=-37Sosf':
Dedr Min. 3S/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet Elastahase or Mule -Hide Nall Base (poly-fllm top surface)
Fasteners: 31 Be. x 1.254mh longx ltinch head diameter round metal cap nails
Spacing: 6-inch ac at the 3-inch wide side laps and 6-Inch o.c. at two (2) equally spaced staggered center rows
Base Ply: (Optional) Potystick MTS or Polystick MTS PLUS, self -adhered.
Underayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP rap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), selfadhered
#9. Maximum Design Pressure = -37.5 W '
Deck: Min.19/324ndh plywood to meet project requirements to satisfaction of Authority HaNingJurisdidlon.
Base Sheet: One (1) or Two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch long 1-inch head diameter round metal cap nails
Spadng: 6-Inch mc. at the }inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Undedayment: Elastofiex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt
#20 Maximum Design Pressure =-45 psP:
Deck: Min.19/324nch plywood to meet project requirements to satisfaction of Authority Havirg.lurisdiction.
Base Sheet. One (1) layerASIM D226, Type II felt
Fasteners: 11 ge.x 125-Inchx3/8-Inch head diameter annular ring shank roofing nails at 2-5/8-Inch diametertincaps
Spacing- 4-inch o.c atthe 2-Inch wide side laps and flinch o.c. at two (2) equally spaced staggered center rows
Base Ply: (Optional; for use with self -adhering underlaymem only) Polystick MTS or Potystick MTS PLUS, selfadhered.
Underiaymertt: Polysdck TU P, PatystickTU Plus, Polystick TU Max, Polyflex SAP, Potyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastofiex G TU, applied In full mapping of hot asphalt.
#21 Maximum Design Pressure =-0S psP:
Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction..
Base Sheet: Two (2) layers ASiM. D226, Type II felt
Fasteners: 11 ga. x 1.254mb long x 3/84nch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps
Spacing. 9-Inch o.c at the 24nch wide side laps and 94nch o.c. at two (2) equally spaced staggered center rows
Base W. (Optional; for use with self -adhering underlayment only) Potystick MTS or Polystick MTS PLUS, self -adhered.
Underayment: Polystick TU P, Polystick TU Plus, PolystickTU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SJ1-APP Cap Sheet (FR), self -adhered or Elastoflex G TU or Etasmflex 56 G, applied in full mapping of hot
asphalt.
#22 Maximum Design Pressure =AS psf:
Deck: Min.25/32-Inch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction.
Base Sheet: Elastohase(sanded top sorfacefor hotasphaltor torch-applled cap or poly -film surface for torch -applied rap)
Fasteners: Simplex MA)OC Cap Fasteners
Spacing: 9-inch o.o at the 24nch wide side laps and 18-inch o.c. attum (2) equally spaced staggered center rows.
Underayment Elastoflex G TU or Elasto8ex S6 G, applied In fullmopping of hot asphalt or Pclyflex G, torch-applled.
#13 MaWinumDesign Pressure=-52.5psF.
Deck Mim 15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastohase(sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-Inchor at the 2-Inch wide side laps and 12-Inch o.e attwo (2) equally spaced staggered center rows.
Undedayment• Eiastaflex G TU or Elastoflex 55 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#14 Maximum Design Pressure=-52Spsf:
Deck Min.15/324nch plywood to meet project requirements to satisfaction of Authority, Having Jurisdiction.
Base Sheet: Elastohase or Mule -Hide Nail Base (poly -film topsurface)
Fasteners Simplex Original Cap Nails
Spacing: &inchme. atthe 34nch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows
Base Ply. (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlaymem: Polystick TU P, Polystick TU Plus,.PolysUdcTU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered. ,
NDMO ETC, LLC. Evaluation Report P12060.02.09-1124
CvtWJW CfAUMonmt= 03245S IPEDITION (M17) FBC NOUt-NVI42EVALUATION FL5259-M
Polyglass Roof Undedayments; (951) 233-WO Rmisian 24:01/24/2018
Page 8 of 24
ONEMOletc.
#15 Maximum Design Pressure = -525 Dsf:
Deck: Min. 115/32-inch plywood to meet project requirements to satisfaction of Authority Having.ludsdiction.
Base Sheet: Elastobase lsanded top surface for hotasphalt or torch -applied cep or poly -film surface for torch -applied cap)
Fasteners: Simplex CrlginalCap.Nails
Spacing: 64neh o.c. at the 3-inch wide side laps and &Inch o c at four (4) equally spaced staggered center rows.
Underlayment Elastofiex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#16 Maximum Design Pressure =-60 psi:
Deck. Min. 19/32-Intl[ plywood to meet project requirements to sausfactlonofAuthority Havingludsdiction.
Base Sheet: Elastolase(sanded top surface for hot -asphalt or torch -applied rap or poly -film surface fortorchapplled cap)
Fasteners: 11 ga. x L25-inch long 3/84nch head diameter annular ring shank raoflng nails at 1-5/8-Inch diameter tin caps
Spacing. 8-inch o.c at the flinch wide side laps and 8-Inch o.e at three (3) equally spaced staggered Center rows.
Underlayment: Elastoflex G TU or Elaswflex 55 G, applied in full mopping of hot asphalt or Polyflex G, torch-applled.
#17 Maximum Design Pressure=-60 Dsf:
Deck Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet. Elanobase(sanded top surface for hot -asphalt or torch -applied cap or poly -film surface fortorchapplied sup)
Fasteners: OMG#12 Standard Roefgdp with OMG Flat Bottom Metal Plates
Spacing. 12-Inch a.e at the 4-Inch wide side laps and 12-inch o.c at two (2) equally spaced staggered terrier rows.
Underlayment. Elastoflex GTU or Elastallm S6 G, applied in full mopping of hot asphalt or Polyflex 6, torch -applied.
#18 Maximum Design Pressure=-67.5Dsf:
Deck Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisiiction.
Base Sheet: Polyglass G2 Base orPolyglas APP Base (requires use of torch-oppiled underfayment)
Fasteners: 12 ga. x 1.2541nch fmgx 3/84nch head diameterannular ring shank roofing nails at 1-5/8-inch diametertin caps
Spacing: 8-inch o.c at the flinch wide side laps and B-Inch o c at four (4) equallyspaced staggered center rows.
Underiayment Elastofiex G TU or Elestofiex S6 G, applied in full mopping of hot asphalt. or torch -applied or Polyflex G, torch -
applied.
#19 Maximum Design Pressure =--75 psF.
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Havinglurlsiiction.
Base Sheet: Polyglas G2 Base or Polyglass APP Base (requires use oftorcfropplied undarlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3' Galvalume Steel Plates, CMG Rootdp #14 with
OMG Flat Bottom Plates (AccuTrec), Tmfast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: ID -Inch e.e at the 4-inch wide side laps and 10-Inch o.c at three (3) equally spaced staggered center rows.
Underlayment Elastoflex G TU or Dastoflex S6 G, applied in fug mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#20 MaximumOesienPrpmure=-901)
Deck: Min 15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet Elastobase(sanded top surface for hatasphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners Simplex MAi(x Cap Fasteners
Spacing: 64nrh o.c at the 2-Inth wide side laps and 64nrh o.c. attwo (2) equally spaced staggered center rows.
Underlayment: Elastaflex G TU ar Elastaflex Sfi G, applied in full mopping of hotasphalt or Poly6ex G, torchapplled.
#21 Maximum Design Pressure --98 mf:
Deck: Min. 35/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet Elastobase(sanded top surface for hotasphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3' Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c atthe flinch wide side laps and 6-Inch o.c at three (3) equally spaced staggered center rows.
Undedaymem: Elastofirx GTU or Elastaflex S6 G, applied in full mopping of hot asphalt or Powex G, torchapplIed.
#22 Maximum Desfen Pressure=-90 Dsf:
Deck. Min 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sandedtop surface)
Fasteners: Trufast#12 DP orTrufast#14 HO with Truiest 31 Metal Insulation Plates
Spacing: 6-Inch o.c at the 4-inch wide side laps and 6-Inch o.e at three (3) equally spaced staggered center rows.
Underlayment Elas[ofiex G TU or ElastoRex S5 G, applied In full mopping of hot asphalt
NEMO EM LLC Evaluation Report P32060.02.03R24
CEd&amolAWmdmxmrba24s5 6EDmON(21117)FBCNON4P)MEVALUAMON FLS259-R26
Polyglass Roof Underlayments, (954) 213-122o Revision 24:01/2412MB
Page 9 of I4
ONEMOJetc.
#23 Maximum Design -Pressure = -90 ttsF.
Deck: Min. 25/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet Polyglass 62 Base or Polyglass APP Base (requires use ojtorch-applied undadayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3' Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrdc), Trufast HD with Trufast 34ndt Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 9-Inch o.c. at the 4-inch wide side laps and 94nch ox atfaur (4) equally spaced staggered center rows.
Undedayment: Elastoifex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or torch -applied or Polyfiex G, torch -
applied.
#24 Maximum Design Pressure =-97-5
Deck: Min. 19/32-Inch plywood to meet project requirements to satisfaction of Authority Having.lurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.254nch x 3/9-Inch head diameter annular ringshank roofing nails at 1-5/8-Inch dlametertincaps
Spacing: 4-Inch ma at the 4-Inch wide side laps and 4-inch o.c. atfour (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick M7S or Polystick MTS PLUS, self -adhered.
Undedaymem: PoWck TU P, Polystick TU Plus. Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#25 Maximum Design Pressure=-105 osf:
Deck: Min.15/324nch plywood to meet project requirements to satisfaction of Authority Havinglurisdiction.
Base Sheet: Elastobase (sanded top surface for hotasphalt or torch-appffed cap or poly -film surface fortordrappiled rap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-Inch c.c. at the 24nrh wide side laps and 6-Inch o.c. at three (3) equally spared staggered center. rows.
Undedaymerm Elastoflex G TU or Elastoflex 56.G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#26 Maximum Design Pressure=-112.5osF.
Deck: ` Min. 19/32-inch plywood to meet projectrequlrements to wUsfaction aFAtMorityHavinglurisdictfon.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 go.x 1.25-inchx3/8-inch head diameter annular ring shank roofing nails at l-5/84nch diameter tin caps
Spacing: 6-Inch o.c. at the 4-inch wide side laps and 6-inch o.t at four (4) equally spaced staggered center rows.
Primer. P6300 or ASTM D41 primer at all tin -caps
Base Ply: Polystick MTS or PoWck MTS PLUS, setfadhered
Underiayment PoWtIckTU P, PolysUck TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#27 Maximum Design Pressure a.120 osf:
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot -asphalt ortorchapplied cap or poly -film surface fortorrhapplled cap)
Fasteners: OMG #12 Standard Rcofgrip or OMG #14 Heavy Duty with OMG 3' Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-Inch o.c at the 4-Inch wide side laps and 6-0nch o.e. at five (5) equally spared staggered carder rows.
Undedaymenr Elastoflex G TU or Elastofiex SG G. applied in full mopping of hat asphalt or Polyflex G, torch -applied.
#29 Maximum Design Pressure=-220osG
Deck Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast#12 DP orTrufast#14 HD with Trufast 3' Metal Insulation Plates
Spacing 6-Inch o.c. atthe 44nch wide side laps and 64nch o.e at five (5) equally spaced staggered center rows.
Undedayment: Elastoflex6 TU or Elastollex S6 G, applied in fug mopping of hot asphalt
5.6.4.1 All other direct -deck, adhered Polyglass, undedayment systems beneath foam -on tilesystems carry a Maximum
Design Pressure of-45 psf..
NERACIMLLM Evaluation Report P12060.02.09-R24
rWjkate olAuroorha0m 9324155 6M EWr10N(2017) Per N014401HEEVAWA110N FU759420
Pafyg%w Roof Underlaymentsi (954) 233-IM Revision 24:01/24/2018
Page 10 of 14
ONEMOletc.
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSAfTRI April 2022 (04-22), Appendix A, Table SA.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 217. Assemblies marked
with an asterisk' carry the limitations set forth in Section.2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2015) for Zone 2/3 enhancements.
5.7 Exposure Umitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polygiass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90•days after Installation..
Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for
Ipngerthan 180-days after installation.
Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering Is to be adhesive -set tile, in which case the maximum exposure is 30
days.
Elastoflex: S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex-G FR does not have an, exposure limitation, unless the
prepared roof covering Is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum
exposure is 180 days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coeffident of friction than ASiM D226
roofing -felt in dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as
set forth in Section 4.3,.Note 1 of ASTM D1970-15, should be established as to slip resistance.
5.9 Tile Sliopakre Limitations (FRSAM April 2012 (04-121)-
When loading roof tiles on the underlayment In direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
' :;;:�2-:
TiisiE*,t.':ilreSpvPiw`ieYiMiTATtvuswiGoi�e�i-4kWr.Tii�lN,si,�hnan;.: - -
Underlayment
Tide Profile
Staging Method
Maximum Slope
tlastaflex,G TU
Fiat
10-tile stack
Lugged
9-tile stack (6 over 2)
&12
EiastoflexS6 G or S6 G FR -
Flat or Lugged
&tile stack (4 over 2)
4:12
PotystickNlTSorPATSPLUS
Flat
6-tllestack(4over2)
5:12
Lugged
6-tile stack (4 over.21
-stack
4:12
PoNstickTile Pro
Flat or Lugged
btile(4 over 2)'
- 7:12
PoWckTU Max
Flat
6-tile stack (4 over 2) or ID-tlle stack
7:12
Lugged
&tile stack (4 ever 2)
7:22
Lugged
36tiTe stack
6:12.
PolyskirkTUP
Flat
6-tile stack (4 over 2)
6:12
Lugged
6-tile stack (4 over 2) -
4.12
PolystickTUPlus
Flat"Lugged
6-tlle stack(4over2)
712
Rat or Lugged
SU-tile stack
6:12
Pol9flex G or G FR - - -
Flat of Lugged
6-tile stack (4 over 2)
4:12
-
PoWex SAPorSAPFR
Flat or Lugged
6-tile stack (4 over 2)
4:22
NEMOEMLLC. Evaluation Report P12060.02.09-R24
outr=w cfAuraor¢oaen E3240 6� EpmON(2017) FBC NONaMMEVALUATION FL5259-M
Poly&. RaarUnderhyk00nts, (934) 233-MO Revision 24: 01/24/2028
Page 11 of 14
ONEMOjetc.
6. INSTALLATION:
6.1 Polyglass Roof Umlerlayments shall be installed in accordance with Polyglass published installation,requlrements
subject to the Umitations set forth in Section 5 herein and the specifics; noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
•:'''.: iL ;lw: ear; :.r: •T. ?,: .,.. ..
t'r9: tlastgbase;ElasfdbLet
eP'lrMule-(1ideNaifHase'..--
Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table
1507.11 for the type of prepared roof covering to be installed.
tlastobas% tlastobase P or Mule -Hide Nag Base maybe covered with a layer of Polystick, Polyflex SAP, Polyflex SA
P Fit, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or
Elastoflex S5 G FR in hot asphalt or Polyflex G or Polyflax G FR, torch applied. Roof cover limitations are those are
those assoclated with the top -layer underlayment, as set forth in Table 1,
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule-i6de Nail Base are limited to use as a mechanically attached base sheet in the 'Two
Ply system" from FRSA/TRI April 2022 (04-12). Reference Is made to Table 1 and Section 5.6.4 herein, coupled with
FRSA/i'RI April 2012 (04-12) installation Manual.
6.4PolystictlNl#s.NMPits, M* i.3tl:P�TtJP.Ip,TUMaitiqu31 Y9rTtl�e odF,iNW1CorPolyflekSAp,PkCyfIPxSAPFRt`
Mule Hides-7►pFiaJrS�ia aFlSiute ftoeSA94hpg1tSfP?et(FRYy
6.4.1 Shall be installed In compliance with the codified requirements for ASTM D1970 (except PolystickTU P) underlayment
6.4.2
In FBC Table 1507.L1 for the type of prepared roof covering to be installed.
Direct -to -Deck with Mechanically Fastened Roof Covers:
All setf-adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP
Cap Sheet orSA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam In accordance with Polyglass /.Mule -
Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-Inch
diameter metal disk or Slmplex-type metal cap nail, at a minimum rate of 12' o.c. Polystick TU Pius should be back -
nailed using the above noted fasteners and spacing, In area marked "nail area, area para clever" on the face of
membrane. The head lap membrane is to cover the area being back -nailed.
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. hand.
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric). in
vrewaf O4elap Sam of Dual Pm and The Pro
All over -fabric and over -granule end -laps shall have a 6-Inch wide, uniform layer of Polyplus So Premium Modified
Wet/Dry Cement or Polyglass PGSOO Modified Cement applied In between the application of the lap.
PolysUdk TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as wickets, exposed valleys,
or exposed roof to wall details
NENIO ETC, kLC. Ewluation Repart P32060.o209-R24
Wrtylm�ofAud+orbaaoa P3rlas 6w EDMON(=7) FBC NON4MUIEVALUATION FL5259-R28
Poh'6law Roof Underlayments: (954) 233-1230 Revislon 24: 01/24/2MB
Page 12 of 14
ONEMOletc.
Repair of Palystick membranes is to be accomplished by applying Palyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PGS00 Modified Cement to the area In need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 404bs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min.28lb roller) or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications that allowed forPohatick Dual Pro IR-Xe orPolvstfck MULA
Reference is made to FRSA%TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the Instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1
For adhesive -set tile applications, refer to Section 5.6.4 herein.
6.4.4 Two (2) Ply Underlayment Systems:
PolystIck MIS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Palyflax
SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are these associated with
the top4ayer material. This Is not a requirement, but is allowable if a 2-ply underiayment system Is desired.
Polystick MIS or MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use
under foam -on tile systems. Limits of use are those associated with the top -layer material. This Is not a requirement,
but is allowable If a 2-olv underiavment system is desired.
5.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex SG G FR shall be installed In compliance with current Polyglass published
installation requirements. For use In the applications:
✓ Elastoflex G Tina for use as an alternate to "Mineral Surface Roil Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRl April 2012 (04-12) beneath mechanically fastened the roof systems or the Hot Asphalt
applied "Cap Sheet' in the" Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Gass M) in the "Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened file roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered Tile roof systems.
✓ Elastoflex S6 G FR Is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the
roof systems.
6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastaflex S6 G or Elastoflex S6 G FR shall be fully asphalt -applied to the
substrates noted in Section S.G. Side laps shall be minimum 3-inch and end -laps minimum 6-Inch wide, off -set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in complete mopping of hot asphalt
with asphalt extending approximately 3/8-Inch beyond the lap edge.
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass puousnea insteuavan regwremenu.
For use in tile applications:
✓ Polyflex G Is for use as an alternate to the Heat Applied "Cap Sheep' In the "Two Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6.3).
✓ Polyflex G FR is for use as an alternate to the Heat Applied 'Cap Sheet" in the 'Two Ply System" from FRSA/TRI
April 2012 (04-22) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3).
NEMO EFC, ILC EvaluaUon Report P12060.02M-R24
MaUlkraofAorlO&9bn/324W eEomoN 12a17) Fac NON4iVN2 Evammox Fsng-ma
Poly&z Roof Underlsyments; (954) 233-1Z30 Revision 24: 01/24/2028
Page 13 of 14
ONEMojetc.
6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall he
minimum 3-inch and end -laps minimum 6-Inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge.
9.1 Tile Staein¢;
6.7.1 Tile shall be loaded and staged Ina manner that prevents the slippage and/or damage to the underlayment Refer to
Table 2 herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter-batbens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used
on all roof slopes greater than 7;12. Precautions should be taken as needed, such as the use of battens or sail-
boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
6.73 Polyglass specifies the minimum cure time after Installation of self -adhering membranes and before loading of
roofing tiles Is forty-eight (48) hours.
7. BUILDING PERMIT REQUIREMEIM'.
As required by the Building Official or Authority Having Jurisdiction in orderto properly evaluate the installation of this product
8. .MANUFACTURING PLANTS:
Contact the noted QA agency far Information an product locations covered for F.A.C. 61620-3 QA requirements. The following
plants have qualified products under their respective physical properties specifications.
.P rrt�.", ...:: -,: • . ; :.•..:, .. ...:
.
•Sler"fi[atioii�.�;�.;;�.t:r.:d _:�_�'i':�
Pre u' s •, - -
Fernley, NV, Hazleton, PA & winter Haven FL
ASTM D3970
Pol ek MU-X
Hazleton, PA
M-D 13-0004.
Elastoflex G TU
Hazleton, PA & Winter Haven, FL
ASTM D1970
Polystick IR-Xe
ASrM D1970 & FRSA/rRI April 2012
Polystick TU Plus
ASTM D1970 & FRSA/rRI April 2012
Polystick TU Max
Tuscaloosa, AL
ASTM D46M, Type II
Polyglass G2 Base
Winter Hawn, FL
ASTM D226 (physicals)
Elastobase, Elastobase P
ASTM D6509
Polvalass APP Base
FRSA/TRI April 2012
-PoI ek MTS, Polystick MTS PLUS
FRSA/TRI April 2012
Poi sdckTUP
F I April 2012
Polyflex SAP, Polyflex SA P FR
ASrM D1970
Polystick Dual Pro
ASTM D1970 & FRSA/TRI April 2022
Polystick Tile Pro
ASTM D6164
Elastoflex S6, Elastoflex S6 G FR
ASTM D6222
PoWex G, PolyflexG FR
9. QUALITY ASSURANCE ENTRY:
UL, LLC—QUA9M; (314)578-3406;k.chancellar@us.ul.com
- END OF EVALUATION REPORT -