HomeMy WebLinkAboutFLOOR PLANSITE SPECIFIC FLOOR PLAN:
SCALE: N.T.S.
UNIT
#5-E
N
65.0' C.
SCANNED
BY
BUILDING FOOTPRINT St. Lucie County
PLAN VIEW CONCF-ALED FASTENERS OR MTAC6,..
ARE THE RESPONSIBILITY OF THE
O CONTRACTOR OF RECORD
----------------------------
I I
UNIT
I I
I I
I I
I I UNIT
NEXT I UNIT #5-E I NEXT
DOOR j ^'20 FT ABOVE GRADE DOOR
I I
I I
I
L--------- --------J
DESIGN NOTES
FLORIDA BUILDING CODE SIXTH EDITION (2017) ASCE 7-10
Vult=170 MPH / Vasd=131.7 MPH (3 SECOND GUST), EXPOSURE'D', ENCLOSED STRUCTURf\,AY�
RISK CATEGORY=II, Kd=0.85, Kzt=1.0, KZ=TABLE 30.3-1, GCpi=+/-0.18
qh = 0.00256*KZ*Kzt*Kd*V*V
MRH 30(GZONE(S) AS NOTED, ROOF TYPE'MONOSLOPE', ROOF SLOPE 0.00 QO�'��GES
PRESSURES: NOTED BELOW
INSTALL ALL SYSTEMS PER VALID FLORIDA PRODUCT APPROVALS
GENERAL NOTES: -_
1. THIS ENGINEERED PLAN IS INTENDED TO PROW DE SITE -SPECIFIC DESIGN PRESSURES FOR THE REFERENCED STRUCTURE FOR.TH/E PJBPOSE
OF THE INSTALLATION OF GLAZED/NON-GLAZED PRODUCTS AS PROPOSED AND PROVIDED BY OTHERS. NO CERTIFICATION EF EFO
EXPRESSED OR IMPLIED, IS OFFERED AS TO THE VALIDITY OR APPLICABILITY OF ANY PROPOSED SYSTEM OR COMPONENT USED'Alnld6 WITr
THESE PRESSURES UNLESS PRODUCT AND APPROVAL INFORMATION IS SPECIFICALLY REFERENCED AND ADDRESSED HEREIN. z l��
2. NO CERTIFICATION OR REVIEW IS OFFERED THAT THE PROPOSED UNITS MEET ANY EGRESS REQUIREMENTS. ALL EGRE95ISSUES dBE
ADDRESSED BY THE PERMITTING CONTRACTOR AND THE LOCAL BUILDING OFFICIAL 7/
3. THIS CERTIFICATION APPLIES TO THE STRUCTURAL PERFORMANCE OF THE SYSTEM ONLY DOES NOT INCLUDE THE CERTIFICATION OF WAY
INFILTRATION OF FIRE SAFETY.
4. THE HOST STRUCTURE IS ASSUMED TO BE ADEQUATE TO WITHSTAND THE LOADS IMPOSED BY THIS DESIGN AS WORK REPLACES THE
EXISTING FRAMING. IF ANY DEFICIENCIES ARE FOUND IN THE EXLSTING HOST STRUCTURE, THIS ENGINEER SHALL BE NOTIFIED BEFORE
CONTINUING CONSTRUCTION AND RESERVES THE RIGHT TO RE -INSPECT AND RE-EVALUATE DESIGN. NO WARRANTY, EITHER EXPRESSED OR
IMPLIED, IS CONTAINED HEREIN. SINCE IT IS NOT PRUDENT TO PERFORM DESTRUCTIVE TESTING AT THIS TIME, THE CONTRACTOR SHALL
VERIFY DURING CONSTRUCTION THAT THE SUBSTRATE IS OF WE TYPE AND CONSTRUCTION THAT IS IN CONFORMANCE WITH THE INTENT OF
THE PRODUCT APPROVAL BEING UTILIZED WHICH MUST BE SOUND FOR INSTALLATION OF THIS SYSTEM AND SHALL NOTIFY THIS ENGINEER
IF ANY DEFICIENCIES OR ABNORMALITIES ARE OBSERVED. USE OF THIS DOCUMENT CONSTITUTES ACCEPTANCE OF THESE TERMS.
S. SYSTEMS SMALL BE AS NOTED HEREIN. ALL REFERENCES TO E(TRUSIONS & INSTALLATION SHALL CONFORM TO THAT OF MANUFACTURERS
SPECIFICATIONS AS SUMMARIZED HEREIN.
6. ANY JUNCTURE OF EXTERIOR PLASTER AND FENESTRATION PRODUCTS SHALL BE SEALED WITH A SEALANT COMPLYING WITH AAMA 800 AND
ASTM C 920 CLASS 2S GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, AND ASTM C1281 OR MMA 812 MR WE
TYPE OF SEALANT TO BE SELECTED WHICH IS OUTSIDE THE SCOPE OF THIS CERTIFICATION.
7. THE CONTRACTOR IS RESLONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS.
B. ALL CONCRETE SHALL BE UNCRACKED ONLY WITH A MINIMUM COMPRESSIVE STRENGTH OF 3DD0 PS1 U.N.O. AND SMALL BE MINIMUM S.SX
THICKER THAN ANY MEMBER EMBEDMENT. ALL EPDXY AND GROUT SHALL MEET OR EXCEED COMPRESSIVE STRENGTH OF WE CONCRETE AND
SHALL BE IRON -FREE, NON -SHRINK AND NON -REACTIVE.
9. FOR ALUMINUM ATTACHMENTS ALL ANCHORS SHALL BE SPACED WITH D IAMETER END DISTANCE AND 2.5xDIAMETER MIN SPACING TO
ADJACENT ANCHORS, UNLESS NOTED OTHERWISE
10. ALL FASTENERS TO BE *12 X 3/4' OR GREATER 2024-T4, 38-8 SERIES 300 NON-MAGNETIC STAINLESS STEEL, OR CADMIUM PLATED OR
OTHERWISE CORROSION RESISTANT MATERIAL AND SMALL COMPLY WITH ALL APPLICABLE FEDERAL,STATE, AND LOCAL CODES.
11. DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY SLIGHTLY, TO THE EXTENT THAT
THE OPENING AREA IS NOT SMALLER THAN 5% OF THE ENGINEERED DESIGN. CONTRACTOR IS TO VERIFY ALL FIELD DIMENSIONS PRIOR TO
INSTALLATION.
12. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, BL aL
INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM
MATERIAL FABRICATION, SYSTEM ERECTION, & CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, &
FEDERAL CODES &FROM DEVIATIONS OF THIS PAN.
13. ENGINEERING EXPRESS HAS NOT VISITED THIS JOBSITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR SUPPLIED DATA AND
MEASUREMENTS. ENGINEERING EKPRESS SHALL NHELD RESPON
SIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA
OR MEASUREMENTS. WORK SMALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SMALL BE NOTIFIED AND GIVEN
AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING
RELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS.
14. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED.
• ALTERATIONS, ADDITIONS, OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION
DESIGN INFORMATION:
MARK
QTY
W H (in.)
ZONE
DESIGN
PRODUCT MODEL
MULLION
MULLION SIZE
x
PRESSURE 0
APPROVAL
PRESSUREAL
APPROVAL #
SENTINEL 110
1
(1)
26.00 x 38.00
5
+47.36 / -63.15
17-1018.08
ALUMINUM SINGLE
+761-75
N/A
N/A
HUNG WINDOW
SERIES SENTINEL
2
(1)
141.00 80.00
5
+41.13 / -50.69
17-1218.20
150 ALUM SLIDING
+80/-80
N/A
N/A
GLASS DOOR
SENTINEL 110
3a
(1)
44.00 x 25.00
5
+47.36 / -63.15
17-1018.08
ALUMINUM SINGLE
+75 /-75
18-0129.08
1' X 2' X 0.125'
•
HUNG WINDOW
SENTINEL 110
3b
(I)
44.00x 25.00
5
+47.36/-63.15
17-1018.08
ALUMINUM SINGLE
+75 /-75
I8-0129.08
1'X 2'X0.125'
HUNG WINDOW
SENTINEL 110
4
(I)
25.00 x 25.00
5
M7.36 / -63.15
17-1018.08
ALUMINUM SINGLE
+751-7
MIA
N/A
-
HUNG WINDOW
ST. LUCIE
BUILDING
FOR
DATE
MUST BE KEPT ON'JOB OR
NO INSPECTION WILL BE MADE
THESE PLANS ARD ALL PROPOZED 141` 11C
AA6 AMOT TOANY CO-PECTIO?13 --
REWIRED DY FIELD INSPECTORS DAT .
14M. NECESSARYINORDER�0 : }
�Q�I:t �11iI�+LL.�r^rL1Car F CODES. is
DRAWING NOTES: a
• ALTERATION LEVEL: THIS SHEET IS INTENDED FOR USE IN PROJECTS WITH IEVEL OF ALTERATION 1 ONLY. IF LEVEL OF ALTERATION IS DIFFERENT, THIS
N IN€�HALL-SE CONTACTEDFORADDTIONALCERTIFICATION.
• DOOR DESIGNATIONS: AMY DOOR PRODUCT SHALL EIDT ONLY TO EXISTING BALCONIES WITH EXISTING 42' MGM APPROVED GUARDS WHICH SHALL NOT
IN
L:J
o N
a
o
r®
WP)nuY
Inrn
wD J
LL_xNu
WV,
w(n
z-o
P'm
Uvcwa
Q��MI
KQ W ow0-0
0 m Z-9 z-E
wW
0,o .'u
0 W BK,Oz
3LL°Wz
on Q' w
b
p W ui
U)
� a
0
HUE
rn
w
�`0`Sge
H
c
1 18-7279
FLOOR PLAN AND UNIT LAYOUT
FOR
HAVE BEEN CAID ATED USING WIDTH=