HomeMy WebLinkAboutDESIGN WIND PRESSUREENGINEERING b tlEXPRESS ® 160 SW 12th AVENUE, #106 DEERFIELD BEACH, FL 33442 PH: (954) 354-0660 FAX:(954) 354-0443 WWW.ENGEXP.COM Wind Load Calculation ASCE 7-10 Ch 30 Wind Loads -Components and Cladding 6th Edition (2017) Florida Building Code Site Information Owner: HERMANSON, TERRI Wind Speed (V): 170 MPH Exposure Category: D Velocity Pressure Coef. (Kh): 1.46 ASCE 7.10 0,30.3.1 Tablr 30.3.1 Directionality Factor (Kd): 0.85 Topographical Factor (KZT): 1.0 Structure Information Risk Category: in Building Classification: Enclosec In t. Pressure Coef. (GCpi): 0.18 ASCE 7-10Table 26.11.1 Mean Roof Height (h): 112 ft. Roof Slope (B): Flat Roof Slope Coefficient (Be): 0.9 Min. Building Dim. (L): 160 ft. End Zone Distance (a): 16 ft. cared in a cardance with:ASCE 7-10. 30. Wind Loads - Components and Cladding Edition (2017) Florida Building Code O 2019 E-Tempest.com 1D: allamericamvpb-P5981 02104/2019 Page 1 of 1 M Desien Wind Pressure (PMAx+. PMAx-): ASCE7-10. Ch. 30.4.2130.6.2 h<60 ft. h>60 ft. Max Positive Pressure (PMAx+) PMAx+ = gh(Bc GCppos + GCp) PMAx+ = gh(0c GCFam + GCp) Max Negative Pressure (PMAx-) PMAx- = gh(Bc GCprey - GCp) PMAx- = gh(Bc GCpney - GCp) Device Calculations:ASCE 7-10. Chanter 30. All Subsections # Size Zone Elevation Area Areal rea I<a q GC°+ GCro_ Pmaa+ Pmaa- x H (W ) (ft ) (fta (Ili/ft2) (lb/ft2) 1 460 x 101.5 Int 73 324.24 489.81 1.36 85.31 0.6 1 -0.7 1 40.7 -48.6 FILE COPY Ti2JA&o— I (02--0� SCANNED BY St. Lucie County \`I1111111f I//11/ ON M. DI6 OQ-'.• LtCENgF •.,. %jam � NO PE82328 O =_ STATE 6VE s'c' o / D BA :ean IdEh�b�A1 H#B8BG WITH RAISED INEER SEAL ix VAUD FOR ( OBONLY