HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSr-
J ALL AMERICAN I
I SHUTTERS & GLASS
1638 Donna Road, Vilest Palm Beach, FL 33409
Owner: FLEMMING, CATHERINE
Address: 3000 N HIGHWAY AlA
APT I IA
FORT PIERCE, FL 34949
r iz-soot • wvrw.auamencansnuiaers-cam
Information
Wind Zone: 170 MPH.
Exposure Category: D
Minimum Building Dimension: 160 ft.
Mean Roof Height: 112 ft.
Risk Category: III
II Design Pressure Calculations II
Opening
Number
Location Device
Zone Width (in)
Device Device
Height (in) Elevation (ft)
Max Positive
Pressure (psf)
Max Negative
Pressure (psi
1
Int
80
101.75
98
53.2
-56.0
2
Int
0
53.2
-56.0
3
Int
75
102
98
53.5
-56.2
4
Int
0
53.5
-56.2
5
Int
760
110.75
98
42.3
-48.5
FILE COPY
ZS�
SCANNED
BY
St. Lucie County
Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads -Components and Cladding. 61h Edition (2017) Florida Building Code.