Loading...
HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSr- J ALL AMERICAN I I SHUTTERS & GLASS 1638 Donna Road, Vilest Palm Beach, FL 33409 Owner: FLEMMING, CATHERINE Address: 3000 N HIGHWAY AlA APT I IA FORT PIERCE, FL 34949 r iz-soot • wvrw.auamencansnuiaers-cam Information Wind Zone: 170 MPH. Exposure Category: D Minimum Building Dimension: 160 ft. Mean Roof Height: 112 ft. Risk Category: III II Design Pressure Calculations II Opening Number Location Device Zone Width (in) Device Device Height (in) Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psi 1 Int 80 101.75 98 53.2 -56.0 2 Int 0 53.2 -56.0 3 Int 75 102 98 53.5 -56.2 4 Int 0 53.5 -56.2 5 Int 760 110.75 98 42.3 -48.5 FILE COPY ZS� SCANNED BY St. Lucie County Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads -Components and Cladding. 61h Edition (2017) Florida Building Code. Page 1 of 1