HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSALL AMERICAN
SHUTTERS & GLASS
rir-coos • wwwanamencansnuuers.cam
Information
Owner: MANGAN, JOHN
Address: 3000 N HIGHWAY AlA
APT 6A
FORT PIERCE, FL 34949
SCANNED
BY
St. Luce Countv
Information
Wind Zone: 170 MPH.
Exposure Category: D
Minimum Building Dimension: 160 ft.
Mean Roof Height: 112 ft.
Risk Category: III
Design
Pressure Calculations
Opening
Number
Location
Zone
Device
Width (in)
Device
Height (in)
Device Max Positive
Elevation (ft) Pressure (pso
Max Negative
Pressure (psf)
1
Int
80
101.75 56
49.2
-56.0
2
Int
56
49.2
-56.0
3
Int
75
102 56
49.5
-56.2
4
Int
56
49.5
-56.2
5
Int
760
101.25 56
39.3
-48.5
FILE COPY
Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads -Components and Cladding. 6th Edition (2017) Florida Building Code.
Page 1 of 1