Loading...
HomeMy WebLinkAboutPRODUCT EVALUATION REPORTPsI.� ■�. ENGINEERING EXPRESS® PRODUCT EVALUATION REPORT EN13INEERING EXPRESS® EXPERT PRODUOT EVALUATION REPORT August 4, 2017 Application Number: FL13757.1-R6 EX Project Number: 15-23M SCANNED Product Manufacturer. Town & Country Industries BY Manufacturer Address: 400 West McNab Road St. Lucie County Ft. Lauderdale, FL 33309 Product Name & Description: 6.8 Accordion Shutter Large Missile Impact Resistant Accordion Shutter Scope of Evaluation: This Product Evaluation Report is being issued in accordance with the requirements of the Florida Department of Business and Professional Regulation (Florida Building Commission) Rule Chapter 8 Ift, F.A.C., for statewide acceptance per Method 1(d). The product noted above has been tested and/or evaluated as summarized herein to show compliance with the Florida Building Code Sixth Edition (2017) and is, for the purpose intended, at least equivalent to that required by the Code. Re-evaluation of this product shall be required following pertinent Florida Building Code modifications or revisions. Substantiating Data: • PRODUCT EVALUATION DOCUMENTS EX drawing #15-2338 titled 46.8 Accordion Shutter", sheets 1-13, prepared by Engineering Express, signed & sealed by Frank L. Bennardo, P.E. is an Integral part of this Evaluation Report. • TEST REPORTS Uniform static structural performance has been tested in accordance with ASTM E330-02 and TAS 202 test standards per test report(s) 00353-1102-07 (signed and sealed by Vinu J. Abraham, PE) by Hurricane Test Laboratory LLC (HTL) and test report #98-016 (signed by George Dotzler) by Construction Testing Corporation (CTC). Large missile Impact resistance and cyclic loading performance have been tested in accordance with ASTM Ell 886-05 & E1996-05 and TAS 201 & 203 test standards per test reports) #0353-1102-07, #0353- 0512-09 (signed and sealed by Vinu J. Abraham, PE) by Hurricane Test Laboratory LLC (HTL) and test report #03-024 (signed and sealed by Yamil G. Kuri, PE) by Constructioq TAaWhy CoWnItion (CTC). • STRUCTURAL ENGINEERING CALCULATIONS •pQ-lpdo*- 6§I Valid for Structural engineering calculations have been prepared which 'Pages 1 jy 2 evaluate the product based on comparative and/or rational = AUG"analysis to qualify the following design criteria: - AI U 7 1. Maximum Allowable Spans 2. Maximum Allowable Design Pressures 3. Minimum Glass Separation = rank€T41901ardp; 0&6t3Q'2�.•' `Jf9885 160 SW 12T" AVENUE SUITE 106, DEERFIELD BEAO1A;r RAC 3442 PHONE: (954) 354-0660 - FAX: (954) 354- 3 ENdINEERINGExPRESS.COM VNpZCIpIM11YKWM 19YI,RqMVGR R•Y 4.IIGIANI,OItlBW ypq,{ppup,R{M1S®tV4Ad,,.lY1C CgW EXPRESS II-.� August 4,2017 Town & Country Industries — 6.8 Accordion Shutter Page 2 of 2 4. Anchor Spacing 5. Anchor Capacity No 33% increase In allowable stress has been used in the design of this product. Separation from glazing is required for use within the HVHZ and essential facilities. An equivalency letter is provided with this evaluation report for equivalency to ASTM E 199"9. Impact Resistance: Large Missile Impact Resistance has been demonstrated as evidenced in previously listed test reports, and is accounted for in the engineering design of this product. Wind Load Resistance This product has been designed to resist wind loads as Indicated in the span schedule(s) on the Product Evaluation Document (i.e. engineering drawing). Installation The product listed above shall be installed in strict compliance with the Product Evaluation Document (i.e. engineering drawing), along with all components noted therein. The product components shall be of the material specified in the Product Evaluation Document (i.e. engineering drawing). Limitations & Conditions of Use: Use of this product shall be in strict accordance with the Product Evaluation Document (i.e. engineering drawing)' as noted herein. All supporting host structures shall be designed to resist all superimposed loads and shall be of a material listed in this products respective anchor schedule. Host structure conditions which are not accounted for In this products respective anchor schedule shall be designed for on a site -specific basis by a registered professional engineer. All components which are permanently installed shall be protected against corrosion, contamination, and other such damage at all times. This product has been designed for use within and outside of the High Velocity Hurricane Zone (HVHZ) 160 SW 12T" AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442 PHONE: (954) 354-0660 - FAX: (954) 354-0443 E N GIN EERINGEXPRESS.COM rwoeno�emu.�ccamoxvxnw.w..�son r�vm.iwnnnnw�asoomnoscrwn, rreew.m.uveevrannremo