Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE_^ Planning& Development Services Department • Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 N NN Certification for Design Load Compliance 0 1:%- Project Name: AL ROBBINS HANGER LOUV. / DOOR p G� Project Address: 3186 AIRMANS WAY FORT PIERCE, FL Permit #: Occupancy Type: Construction Type: V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Any accessory structure requiring a building permit o Any non residential structure. ° Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the #above for questions. I. DESIGN CODE: Florida Building Code 2017 Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed —Partially Enclosed _Open 3. Risk Category: —1 X j II_ Ill_ IV Exposure Category: _ B X C D 4. Design Wind Velocity 165 mph US Aso N/A LRFD End Zone Width: 5 ft S. Mean Roof Height: 35; ft Roof Pitch: 0.3 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): 16.8 1 16.8 16.8 41.2 41.2 + 38,3 Zone 1: -41.2 Zone 2: I_69.2 Zone 3: _104.1 Zone 4: 44.7 Zone 5: _55.2 Garage: qg,f 7. Design Loads: Floor: 100 PSF Roof/Dead: N/A PSF Roof/Live: N/A Balcony:. N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF / CONCENTRATED 8. Were Shear Walls Considered For Structure? -A_Yes _Not Applicable Explain Why Not: { 9. Is A Continuous Load Path Provided? --X-Yes --_Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Yes I certify that, to the best of1my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specked: - Signature; Date, and seal SU-CM Form A U20-12 Revisetl�3/1S/12 iJS) Paul Welch P.E. Print Name Paul Welch Inc. 29945 / 5115 Cert # & Co. Cert Auth. 1984 S.W. Biltmore St. Suite #114 Port St. Lucie, FL Company Name & Address