Loading...
HomeMy WebLinkAboutMISC LETTERJ` PAUL WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 Email pwelchinc@aol.com FFB `Fa p° Zr February 19, 2019 `SCANNED '8 10 S BY <<,C/, ,,,«.. c°��y Re: DiDomenico Shutter Installation Sf.Lucien.,,°�7t 9550 S. Ocean Dr. (#1207) Jensen Beach, FL 34957 To' Whom It May Concern: Out office has calculated the required design pressures in accordance with ASCE 7-10 and Florida Building Code 2017 for the installation of accordion shutters at the above referenced address. Wind speed: V„ I,: 165 mph, Vaw: 128 mph Exposure: D S'CQ Enclosure Type: Enclosed Shutter Size: 96" Maximum Height Sf`4C/eC NCO Shutter Location: Covered Porch (See Attached Sketch) 0% Required Design Pressure: +51.3 / -68.7 PSF Shutters to be installed shall be equal to, or exceed the required design pressures as listed above "Required Design Pressure". Accordion Shutters shall be installed in accordance with the shutter manufacturer's installation instructions and Florida Product Approval and Florida Building Code 2017. - Accordion Shutters shallbe FL# 389.1. IW7 -oy15 ST. LUCIE COON Thank you for your attention to this matter. BUILDING Divlsl CONCFALO FASTENERS OR ATTACHMENTS REViE D Submitted by: FOR � � ARETHERESPONSIBUNOFTHE DAB �`- PAUL WELCH INC. DATE I CONTRACTOR OF RECORD PLA S o P RMIT MUST BE KEPT JOL4. OR No INSPECTION Vl� LL BE ;,L.^ n. THES[ PLANS A,`•JD ALL PP,OP ,r ARE SUBJECT TO OSED 4N Oj Paul Welch, P.E. c"QU'RED BY FIELD INSPECTORS ITt y T Reg. No 29945 CONTRACTOR CORD` MAY BE 1dECESSAt;Y IN OROEg TO CCif ALY 6�IITH ALL APPLICABLE CODE,^, ti, �qba -oq--i5 PAUL WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 Email pwelchinc@aol.com February 19, 2019 Re: DiDomenico Shutter Installation 9550 S. Ocean Dr. (#1207) SCANNED Jensen Beach, FL 34957 BY To Whom It May Concern: St. Lucie County R�c1wFO FF� 2 PeN 10,8 tti St. Cye pe a ent Our office has calculated the required design pressures in accordance with ASCE 7-10 and Florida Building Code 2017 for the installation of accordion shutters at the above referenced address. Wind speed: Vdt: 165 mph, Vim: 128 mph Exposure: D Enclosure Type: Enclosed Shutter Size: 96" Maximum Height Shutter Location: Covered Porch (See Attached Sketch) Required Design. Pressure: +51.3 / -68.7 PSF Shutters to be installed shall be equal to, or exceed the required design pressures as listed above "Required Design Pressure". Accordion Shutters shall be installed in accordance with the shutter manufacturer's installation instructions and Florida Product Approval and Florida Building Code 2017. Accordion Shutters shall be FL# 389.1. Thank you for your attention to this matter. Submitted by: PAUL LCH INC. Paul W ch, P.E. Reg. No 29945 CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILrrY OF THE CONTRACTOR OF RECORD lcfaz -af ST. LUCiE BUILDING I t: m MUST BE KEPT 4 J013 OR No INMPECTIOP; :t'! . ME MASH THESE PLANS AND ALL PROPOSCO VdORIf ARE SUBJECT TO ANY CORRECiICN3 R=OUIRED EY FIELD INSPECTORS MAT MAY BE NECESSARY IN ORDER TO CO&FI Y WITFI ALL APPLICABLE CODES.