HomeMy WebLinkAboutFLOOR PLANr SITE SPECIFIC FL&OR PLAN: SCALE: N.T.S. UNIT #A-70 7 93.0, FILE COPY BUILDING FOOTPRINT�cr� ���«62-og6I3 PLAN VIEW UNIT NEXT DOOR T T O 2 DESIGN NOTE';. ��L`I I FE RDQ P.E. _ X Xo�674 FLORIDA BUILDING CODE SIXTH EDITION (2017) ASCE 7-10 Vult=170 MPH / Vasd=131.7 MPH (3 SECOND GUST), EXPOSURE'D', ENCLOSED STRIItfl�-�,•'•�) RISK CATEGORY=II, Kd=0.85, Kzt=1.0, KZ=TABLE 30.3-1, GCpi=+/-0.18 Cl E �' .• qh = 0.00256*Kz*Kzt*Kd*V*V C1: ,/+ 9F j P = qh ((GCp)-(GCpi)) - NaP= E82 MRH=140', ZONE(S) AS NOTED, ROOF TYPE 'MONOSLOPE', ROOF SLOPE 0.0° - it °TYF, PRESSURES: NOTED BELOW :- _ DIBA 23 P:E _ INSTALL ALL SYSTEMS PER VALID FLORIDA PRODUCT APPROVALS �� •_ ,,2 GENERAL NOTES: 1. THIS ENGINEERED PLAN IS INTENDEDTOPROVIDE PRODUCTS AS PROPOSED PRESSURE OF THE INSTALLATION OF GINT ED/NON-GLAZED PRODUCTS CI IC DESIGN AND PROV SURE N EXPRESSED OR IMPLIED, IS OFFERED AS TO THE VALIDITY OR APP ICABI ITY OF ANY T THESE PRESSURES UNLESS PRODUCT OF AND APPROVAL INFORMATION IS SPECIFICALLY 2. NO CERTIFICATION OR REVIEW G OFFERED CONTRACTOR A ND T PROPOSED UNITS G MEET ANY . ADDRESSED BY THE PERMUTING WESTSTRUCTURAL THE LOCAL BUILDING OFFICIAL 3. THIS CERTIFICATION APPLIES TO THE STRUCTURAL PERFORMANCE OF THE SYSTEM O INFILTRATION OF FIRE SAFETY. 4. THE HOST STRUCTURE IS ANY DEFIED TO BE ADEQUATEFOUND I WITHSTAND EXISTING ND THE LOADS IM EXISTING FRAMING. IF ANY DEFICIENCIES ARE FOUND IN THE EXISf1NG HOST S-EAI CONTINUING CONSTRUCTION AND RESERVES THE RIGHT TO TO INSPECT AND REEVE IMPLIED, IS DURING CONSTRUCTION ON T HEREIN. SINCE IT IS NOT PRUDENT TO PERFORM D CONSCFI VERIFY DURING CONSTR BEING UTHAT TH" E SUBSTRATE IS OF THE TYPE AND AU-ATI I THE PRODUCT APPROVAL BEING UITLIZ® WHICH MUST BE SOUND FOR INSTALL4TI0 Fi NOT¢OXT10 NA INAL TURE'& I EIR SEE l IS )R TH�✓�y�+W[�i SIGN THIS EITHER G v/O y1QEf1 �TYOFA DIGITALLY ED ALONG (M{SH 9LENBD �1 HALLREMAIN IN I 1 I BIGIILAL RORMAT. & PRINTED III a4:I LJ .y MlgliY_19*03-.14 DOES NOT INCLUDE THE CERTIFICATION OF WATER D BY THIS DESIGN AS WORK REPIACES THE E. THIS ENGINEER SHALL BE NOTIFIED BEFORE IN CONFORMANCE WITH THE INTENT IF AM DEFICIENCIES OR ABNORMALITIES ARE OBSERVED. USE OF THIS DOCUMENT CONSTITUTES ACCEPTANCE OF THESE TERMS. 5. SYSTEMS SHALL BE AS NOTED HEREIN. ALL REFERENCES TO EXTRUSIONS & INSTALLATION SHALL CONFORM TO THAT OF MANUFACTURER'S SPECIFICATIONS AS SUMMARIZED HEREIN. 6. ANY ]UNCTURE OF EXTEtIOR PIASTER AND FENESTRATION PRODUCTS SHALL BE SEALED WITH A SEALANT COMPLYING WITH AAMA 80D AND ASTM C 920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, AND ASTM C1281 OR AAMA 812 FOR THE TYPE OF SEALANT TO BE SELECTED WHICH IS OUTSIDE WE SCOPE OF THIS CERTIFICATION. 7. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. S. ALL CONCRETE SHALL BE UNCRACKED ONLY WITH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI U.N.O. AND SHALL BE MINIMUM 1.5X THICKER THAN ANY MEMBER EMBEDMENT. ALL EPOKY AND GROUT SHALL MEET OR EXCEED COMPRESSIVE STRENGTH OF THE CONCRETE AND SHALL BE IRON -FREE, NON -SHRINK AND NON -REACTIVE 9. FOR ALUMINUM ATTACHMENTS ALL ANCHORS SHALL BE SPACED WITH 2xDIAMETER END DISTANCE AND 2.5xDIAMETER MIN SPACING TO ADJACENT ANCHORS, UNLESS NOTED OTHERWISE. 10. ALL FASTENERS TO BE #12 X 3/4- OR GREATER 2024-T4, 18-8 SERIES 300 NON-MAGNETIC STAINLESS STEEL OR CADMIUM PLATED OR OTHERWISE CORROSION RESISTANT MATERIAL AND SHALL COMPLY WITH ALL APPLICABLE FEDERAL, TATE, AND LOCAL CODES. 31. DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY SLIGHTLY, TO THE EXTENT THAT THE OPENING AREA IS NOT SMALLER THAN 5% OF THE ENGINEERED DESIGN. CONTRACTOR IS TO VERIFY ALL FIELD DIMENSIONS PRIOR TO INSTALLATION. 12. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, & CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 13. ENGINEERING EXPRESS HAS NOT VISITED THIS IOBSITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. WORK SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. 14. EXCEPT AS EXPRESSLY PROW DED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. ALTERATIONS, ADDITIONS, OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION DESIGN INFORMATION: MARK QTY W x H (in.) ZONE DESIG PRODUCT pRODUCf MODEL APPROVAL (PRESSURE p APPROVAL # PRESSURE (sI) 1 (1) 15.00 x 71.00 4 +56.05 / -61.91 17-0614.09 PW-5520 VINYL PVC +80 /-110 FIXED WINDOW SERIES DH-5560 PVC 2 (1) 42.00 x 71.00 4 +55.89 / -61.92 17-0630.10 DOUBLE HUNG +70 /-110 WINDOW 3 (1) 15.00 x 71.00 4 +56.05 / -61.91 17-0614.09 PW-5520 VINYL PVC +80 /-110 FIXED WI OW FI Lt UU F Y DECEIVED FEB 2 5 319 ST. Lucie County, Permitting DRAWING NOTES: LEVEL OF ALTERATION 1 ONLY. IF LEVEL OF ALTERATION IS DIFFERENT, THIS BALCONIES WITH EXISTING 42' HIGH APPROVED GUARDS WHICH SHALL NOT THIS SHEET ID to N O Z -i'T f IT of �ED W. FM -mu WLEfF1A 0::)-Jwo W V110 LL Ln Z D w -X LWUju-NXQ �Q W w LDo p=In 4w D- y • LD ' K WW ON�-LUUWju o wPo? ILL N W ` i w O w di wp (i -1 z V J 2 n z' o = Ln W w o ' O L) In xHb U Z w LL O Q N Z W m w O N H N O LU C p U) n UO m w IA m v o w V) ^ Q n 3 Zm C0 w W U 2 f G m � u LAB a M u 0 gala 0 �o 100PYNTGHT ENGINEERING EXPRE55a 1 1 19-7457 1 FLOOR PLAN AND UNIT LAYOUT PRODUCS HAVE BEEN CRLNIATED USING WIDTH - MIGHT/ 3(EFFECTIVE ARIA =H'H ) ■■