Manufacturer: MI Windows and Doors, LLC
650 W. Market St.
Gratz, PA 17030
Product Line: 185 Picture Window— 73" x 61" Impact
Engineering Evaluation Report
Report No.: 513781
RECEIVED
MAR 2 7 2019
ST. Lucie County, Permitting
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61G203.005 method 1(a). The product listed
herein complies with requirements of the Florida Building Code. -
Supporting Technical Documentation:
1. Approval document: drawing number OB-02947, prepared, signed and sealed by Luis Roberto Lomas P.E.
2. Report No.: C7979.02-10947 signed and sealed by Michael D. Stremmel, P.E.
Architectural Testing Inc., York, PA
AAMANVDMA/CSA 1ol/I.S.2/A440-08
Design pressure: t55.14psf
Water penetration resistance 9.19psf
3. Report No.: C7979.01-1094T signed and sealed by Michael D. Stremmel, P.E.
Architectural Testing Inc., York, PA
ASTM E1886-05 and ASTM E1996-05
ASTM E18861 E1996 Large Missile Impact, Level D. Wind Zone 3
ASTM E1886/ E1996 Cyclic Load Test, 355.0psf design pressure
4. Anchor calculations, report number 513781-1, prepared, signed and sealed by Luis Roberto Lomas P.E.
Limitations and Conditions of use:
• Maximum design pressure: 355.0psf
• Maximum unit size: 731/4" x 61'
• Units must be glazed per ASTM E1300-04/09, see installation instructions for glass details.
• This product is not rated to be used in the HVHZ.
• This product is impact resistant and does not require impact protection in wind borne debris regions.
• Frame material to be Aluminum 6063-T5.
Installation: Units must be installed in accordance with manufacturers installation instructions and approval document,
08-02947.
Certification of Independence. Please note that I don't have nor will acquire a financial interest in any company
manufacturing or distributing the product(s) for which this report is being issued. Also, [don't have nor will acquire a
financial interest in any other entity involved in the approval process of the listed product(s).
SCANNED
BY
St. Lucie County
1 of 1
*� �lIo�51 - it
TAT ((ST
�7 OF
OR1DP •fill
NA `1��1G����
Luis R. Lomas, P.E.
FL No.: 62514
11/03/2016
L. Roberto Lomas P.E.
1432 Woodford Rd.
Lewisville, NC 27023
434-688-0609
rgomas@lrlomaspe.com
Manufacturer: MI Windows & Doors
650 West Market Street
Gratz, PA, 17030
Engineering Evaluation Report
Product Line: Series 185 Aluminum Single Hung Window 36° x W — Impact
Report No.: 513321E
Compliance.
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61G20-3.005 method 1(a). The product listed
herein complies with requirements of the Florida Building Code.
Supporting Technical Documentation:
1. Approval document: drawing number 08-02545 revision B, prepared, signed and sealed by Luis Roberto Lomas P.E.
2. Test report No.: E1729.01-10947 signed and sealed by Michel D. Stremmel P.E.
Architectural Testing Inc., York, PA
AAMAIWDMA/CSA 101/I.S.2/A440-08
Design pressure: ±60.15psf
Water penetration resistance 9.19psf
3. Test report No.: E1729.02-10947 signed and sealed by Michel D. Stremmel P.E.
Architectural Testing Inc., York, PA
ASTM E1886-05 and ASTM E1996-12
ASTM E1886/ E1996 Large Missile Impact, Level D. Wind Zone 3
ASTM E18861 E1996 Cyclic Load Test, t55.Opsf design pressure
4. Anchor calculations, report number 513321-1, prepared, signed and sealed by Luis Roberto Lomas P.E.
Limitations and Conditions of use:
• Maximum design pressure: 355.0psf
• Maximum unit size: 36" X 84"
• Units must be glazed perASTM E1300-04/09, according with glazing details in approval drawing.
• This product is not rated to be used in the HVHZ
• This product is impact resistant and does not require impact protection in wind borne debris regions.
• Frame material to be Aluminum 6063-T5.
installation:
Units must be installed in accordance with manufacturers installation instructions and approval document, 08-02545
revision B.
Certification of Independence:
Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the
product(s) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other entity
involved in the approval process of the listed product(s).
1 of 1
5 R I IC O/Zii
i
• 0 51
/TAT OF •sy�
���'"Fs:;�OR1aP•�����
Luis R. Lomas, P.E.
FL No.: 62514
10/02/2017
L. Roberto Lomas P.E.
1432 Woodford Rd
Lewisville, VA27023
434-688-0609
rilomas@ldomaspe.com
Manufacturer: MI Windows and Doors, LLC
650 West Market St
Gratz, Pennsylvania 17030
Product Line., CM-18532 - Horizontal Mullion
Engineering Evaluation Report
Report No.: 512077B
Comp/lance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(d). The product
listed herein complies with requirements of the current Florida Building Code.
Supporting Technical Documentation:
1. Approval document: drawing number 08-01453 Revision B, prepared, signed and sealed by Luis Roberto
Lomas RE
2. Mullion analysis report No. 512077-1A, -2A, and -3A per AAMA 450-10, Option 3, prepared, signed and
sealed by Luis Roberto Lomas P.E.
Limitations and Conditions ofuse:
• Maximum design pressure: refer to design pressure charts in approval document.
• Maximum single window unit size: 521/8" x 84"
• Window units attached to mullion must have their own separate approval.
• This product is not rated to be used in the HVHZ.
• This product is impact resistant and does not require impact protection in Wind -Boma Debris Regions, up to
Wind Zone 3.
• Design pressure of mulled units shall be controlled by the lesser design pressure of the assembly
components; mullion or individual units.
• All windows attached to mullion must be manufactured by MI. Windows and Doors, Inc.
Installation:
Mullion must be installed in strict accordance with manufacturer's installation instructions and approval document
08-01453 Revision B.
Certification ofIndependence.
Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the
product(s) for which this report is being issued. Also, I don't have nor will acquire a financial Interest in any other
entity involved in the approval process of the listed product(s).
1of1
. 11R' IL/11�q
51
TA TE OF43 •��
GRID; G���`
: 4
/ONA
10116/2017
L. Roberto Lomas P.E.
1432 Woodford Rd.
Lewisville, NC 27023
434-688-0609
rilomas@lrlomaspe.com
Manufacturer: MI Windows and Doors, LLC
650 West Market St
Gratz, Pennsylvania 17030
Product Line: CM-18531 -Vertical Mullion
Engineering Evaluation Report
Report No.: 512067B
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(d). The product
listed herein complies with requirements of the current Florida Building Code.
Supporting Technical Documentation:
1. Approval document: drawing number 08-01443 Revision B, prepared, signed and sealed by Luis Roberto
Lomas P.E
2. Mullion analysis report No. 512067-1A per AAMA 450-10 Option 3, prepared, signed and sealed by Luis
Roberto Lomas P.E.
Limitations and Conditions of use:
• Maximum design pressure: refer to design pressure charts in approval document.
• Maximum single window unit size: 52 1/8" is 84"
• Window units attached to mullion must have their own separate approval.
• This product is not rated to be used in the HVHZ.
• This product is impact resistant and does not require impact.. protection in Wind -Borne Debris Regions, up to
Wind Zone 3.
• Design pressure of mulled units shall be controlled by the lesser design pressure of the assembly
components; mullion or individual units.
• All windows attached to mullion must be manufactured by MI Windows and Doors, Inc.
Installation:
Mullion must be installed in strict accordance with manufacturer's installation instructions and approval document
08-01443 Revision B.
Certification of Independence:
Please note that don't have nor will acquire a financial interest in any company manufacturing ordistributing the
product(s) for which this report is being issued. Also, I don't have norwiil acquire a financial interest in any other
entity Involved in the approval process of the listed product(s).
1 of 1
\`\`J\S RI I I. 0ll ,�i i
�,•.��r E N s� Sep y
Q' 7AT_ _ 7-
OR I'D
01VAL1E�����
10/16/2017