HomeMy WebLinkAboutNOAf.
SCANNED
BY
M®DAIDE St. Lucie Countv
DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY
AFFADIS (PERA)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
12195 NW 98'" Avenue
Hialeah Gardens, It 33018
MIAMI-DADE COUNTY .
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of
construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade
'County PERA -Product Control Section to be used in Miami Dade County and other areas where allowed by
the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code, including the High Velocity Hurricane Zone.
DESCRIPTION: 91- 4" Wide x W High Steel Sectional Garage Door w/ Window Lite Option
APPROVAL DOCUMENT: Drawing No. 01-09, titled "Sectional Garage Door", dated 02101/2001, with
last revision F dated 10/13/2011, sheets I through 5 of 5, prepared by AI-Farooq Corporation, signed and
sealed by Javad Ahmed, P.E., bearing the Miami -Dade County Product Control revision stamp with the
Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile hnpact Resistant
LABELING: A permanent label with the manufacturer's name or logo, manufacturing address, model
number, the positive and negative design pressure rating, indicate impact rated if applicable, installation
instruction drawing reference number, approval number (NOA), the applicable test standards, and the
statement reading `Miami-Dade..County Product Control Approved' is to be located on the door's side track,
bottom angle, or inner surface of a panel.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of
any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to
comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
�by the expiration date may be displayed in advertising literature. If any portion Ad, then
it shall be done in its entirety. W
INSPECTION: A copy of this entire NOA shall be provided to the user by the mat ty� 4j,,t�i�s
distributors and shall be available for inspection at the job site at the request of the Bm'Iding�fl4&'kl.
This NOA revises NOA # 11-0119.21 and consists of this page 1 and evidence p kftW, as well as
approval document mentioned above. L.0060 County, Fl.
The submitted documentation was reviewed by Carlos 1VL Utrera, P.E.
NOA No. 12-0110.116
ECOU MN7Y Expiration Date: August 9, 2016
lAMIDA�
; AD Dapy
012
02/21�20l2 ge l
. DAB Door Compan-y. Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. 01-09, titled "Sectional Garage Door", dated 02/0112001, with last
revision F dated 10/13/2011, sheets 1 through 5 of 5,.prepared by Al-Farooq
Corporation, signed and sealed by Javad•Abmad, P.E.
B. TESTS "Submitted underNOA # 09-0128.04"
1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
4) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94
along with marked -up drawings and installation diagram of a DAB 824 24 GA
Sectional Garage Door with Fixed Windows, prepared by Hurricane Engineering &
Testing, Inc, Test Reports No. HETI-08-2149A/B, dated 06/27/2008, signed and
sealed by Candido F. Font, P.E.
"Submitted under NOA # 09-0128.04"
2. Test report of Tensile Test per ASTM E 8, Report No. HETI 08 T182, prepared by
Hurricane Engineering & Testing, Inc., dated 12/23/2009, signed and sealed by
Candido F. Font, P.E.
"Submitted under NOA # 03-0210.04"
3. Test report on Salt Spray (Corrosion) Test per ASTM B 117 of a painted G-40 steel
panels, prepared by Celotex Corporation, Test Report No. 258592, dated 08/17/1998,
signed by W. A. Jackson, P.E.
C. CALCULATIONS "Submiued under NOA # 09-0128.94"
1. Anchor verification calculations prepared by Al-Farooq Corporation, complying with
F.B.0 2007, dated 12/19/08, signed and sealed by Humayoun Farooq, P.E.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Permitting; Environment, and Regulatory Affairs (PERA)
4 t
oa t vro-
rlos fd. Ifirera,P.E.
Product Control Examiner
NOA No.12-0110.06
piration Date: August 9, 2016
FIE
� o a D ch 1, 2012
E-1
DAB Door Comnanv, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 08-0305.02, issued to SABIC Innovative Plastics, for their
Lexan Sheet Products, approved on 04/24/2008 and expiring on 07/17/2013.
2. Notice of Acceptance No. 07-1016.07, issued to Insulfoam, LLC, for their
Insulfoam Expanded Polystyrene Insulation, approved on 11/29/2007 and expiring on
l l/29/2012.
3. Notice of Acceptance No. 07-1107.09, issued to Dyplast Products, LLC, for their
Expanded Polystyrene Block Type Insulation, approved on 04/26/2007 and expiring
on 08/27/2008.
4. Notice of Acceptance No. 07-0301.10, issued to Dyplast Products, LLC, for their
Dyplast LSO-Cl Polyisocyanurate Insulation, approved on 06/07/2007 and expiring on
01/11/2012.
"Submdited underNOA # 05-0228.02"
5. Test Report on Accelerated Weathering Using Xenon Are Light Apparatus Test per
ASTM G155 of "PVC Extrusion Material", prepared by Hurricane Engineering &
Testing, Inc., Report No. HETI 04-A002, dated 09/27/2004, signed and sealed by
Rafael E. Droz-Seda, P.E.
6. Test Reports on Tensile Test per ASTM D638 of "PVC Extension Material", prepared
by Hurricane Engineering & Testing Inc., Report No. HETI 04-T251, dated
11/29/2004 signed and sealed by 1. Ghia, P.E.
7. Test Report on Self -Ignition Temperature Test, Rate of Burn Test and Smoke Density
Test of "REHAU non -foam PVC extrusion material", prepared by ETC Laboratories,
Report No. 04-761-15019.0, dated 05/06/2004, signed and sealed by J. L. Doldan, P.E.
F. STATEMENTS
1. Statement letter of code conformance to 2010 FBC and no financial interest, issued by
Al-Farooq Corporation, dated 10/26/2011, signed and sealed by Javad Ahmad, P.E.
Carlos K Utrera, P.E.
Product Control Examiner
NOA No. 12-0110.06
Expiration Date: August 9, 201.6
A proval to OVI
2012
E -2
Fito 1 m :� n'�a> um ;i ald'.i $oyy v42mu2m
9 F 33 m
lag "Ln-�Ai� _0� ion kAA tl =M9fm m
Ul IN
;"g@ -,m a G
i sum U1 sP gig gig 10;
9 �f= a�2$ >a f Ai m �83i sHio
$F 88
.5 ❑❑3 F�go rv�p $i 33 Z�
N
60p�
0
�eR^ $LmL� wy m m
806 48 4 s�b FSr
4: Q 2 Q pia .
y mbs B 2 of
16 �a
• r
i
1 �x
\ w0
n
w
lip
1 �Z i
a ��•
i 9<$m S
R
C
U4
8
m�mmmS
pqP� $$ a5
F gRE
v
Ell
R�RCX
=$ �g
€ $$g$ s 1 H
T IT TIP
St1 N NN♦
�� 3g
, m
r� � om •m
m=A,
nr.SECTIONAL GARAGE DOOR AL FAROOQ CORPoRA77ON0 M mWSl169(� E INEFSS6PROtmICE�EVFLOPNmDAB DOORS INC. &W.t AW
12195 N.W. 98 7)L AVE. 14 m nonlnAa 174r.., 1 �mPa am v� HIALEAH GARDENS. FL 11 Innn w mw¢om scr t¢. (am) E.sa _ EExa at-asws
!tom
MC
1m
STEEL MIN.
DK WASHER
Is % Jl4' SMS
-® J/J PROM ENDS
AND T O.O. MAX
.002 DEEP
AG2 DEEP
W. WASHER
IR PANEL
G (.024) STEEL MIN.
24 GA
n
# PLASTIC COMPLIES WITH .eoD
SECTION 281E OF FBC 2007 I��•
SEE VADENCE
2612 PAGE
Zt
1.75J 1.725 Q E
�4 6
L�
21 J/4' $$
MAX. .170 m 99 i Q
WDW. WIDTH
y #EXTERIOR FRAME # INTERIOR FRAM0 dm
3 IB 1/B' RIGID PIC ONE PIECE RJECTION RIGID PVC ONE PIECE INJECTION
4 10: I1 4aR12 I P
i
1,
E;®J
q = J
F 1 !®J
N �®J l
r
RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWS
70%
z
drawing no.
01-09
RNEf9
% s-1/2' % J' % 04'
5/I6' X 1-5/8' LAG SCREWS RRO WOOD OR
.f
GAVV. STEEL
ALV. uEl
RIXD BRACKET (OOIIB
5/10' SLEEVE ANCHORS
WITH 1-1/4' EMBED INTO MASONRY)
AS� 14 % S/8 SN.S _
FASTENED W/ 5) (8)
_
J PER BRACKET
OBU W. GAM STEEL ADRISTABLE
SUM FASTENED TO BRACKET
2-1/2" X 4-1/4' X 13 CA STEEL PLATES
I-W/ 5//13-18 X 3/4' NIX HEAD
WELCED TO 1-1/2' X 1-1/2' % 14 0A ANGLE
POP RNEIS
2°
FASTENED W/ (4)
MEETING RIB
2' M X .50" ROLLERS
.44 DLL X 4-1/4' MEN
14 Oh CAM STEEL
RR�O/1� MGM
FAAB ENm
UN..024' ROLL FORMED STEF]. PANEL
WE OWUIY 0-40
WINE PFUMERRAND �OV(mNm
APPUW TO 9GIN SIDES TBfEEI
12 DA DALY. STEEL
W%(
4) jt4GXFG/,rrTSNsm
FASIENEO TO TRACK
WITH (4) 1/4-20 M. BOLT k NUTS
HDRIZ. TRACK SUPPORT,
CENTER SUPPORT REOD. ON DOORS
FFNNI�H��m a R. W HD
A ~ 1
-- A—J
G4. OV.V. STEEL TRACK
2% 2 K 1/B° HORS. ANGLE
SPOT WELDED 1 TO HOME. RM ATRACKNGLE
WNH TWO W S AT 1-1/2' APART
FOIST AT 3' O.O.
REST AT B' O.m
CONNECTED TO FIAG BRACKET ANGLE
B
��I f
V
Z
o
W/ J/B-Ie x s/4' BOIr h NM
PIID TO -IQ, HAR 0110E m
p
(2) 1/4-20 % B/8° BOLT 4 NUT
£
r £ Ga
O
2 /B� 080•
SECTION A -A
e
�II Ui
d g Q
BOOR
HEIGHT
A SECTION HEIGHTS
1ST 2ND 3RD 4TH 5TH
BI B2 B3 B4 85 Be B7 BB
w-O'
IB'
18'
18° 18'
A
1'
11-0 4"
23'
J4°
45'
8'-8'
21'
IB'
IB° 21'
N A
1'
II-3 4"
9
34'
4fi°
7'-O•
21'
21'
2f° 21'
A
1'
11-J 1
2J'
34°
4S'
mar78-1
T-8°
18'
18"
18° 18"
18'
1"'
11-J 4
23"
34°
48°
W-0"
21°
18'
18' 1B'
21'
1`
11-3/4"
2T'
34'
45'
•-SECTIONS ME NUMBERED STARMO AT THE BOTTOM
FOR DOORS MORE = 8 FL HIGH. USE ADDRIDNAL TRACT( BRACMTS AT 10' O.C.
e
m
TRACK CONFlC.IIRANON
VERTICAL LILT HIGH LJR STANDARD LIFT LOW HEADROOM
DOUBLE TRACK
AVAMAL(�K .QPTIONS
A0 VAAU711 ?..- I PBOO muVL48D
iyI a
A �
a s
rcwin9 no.
01-09
eat 3 Of 5
FOR CONNECTNN OF WCOa BUCK
M MASONRY SEE NOTE ON SHEET a
SOUTHERN PINE
D.05 S.01
.1I. EDC 0
2-K' X 1' X .M' /
pGTEN V. STEE1 TRIL% J
W/ I/4-ZO%T6/a MUSS HH.. INSTALET
SUITED M.S. 6 TACK NUT
.024' m PANEL
OUTSIDE OF DOOR
ACK BRACKET FASTENED SDLIp 9RASR DDOR NEWER
I JAMB " 4i 'SCHLAGE SECURITY HARDWARE'
HIR a LAB SCREW INSTALLED IN 9/16" DOA HOLES IN CENTER STILE
IS POSITIONED AT EYE LEVEL
BY DODL ISHTOP NWLOP'C
.01PER DES J4'%2'
D SIN
O 12" OA.
I-1/2' X .050' SAM STEEL)
OEM HINGE
SECT10N R-R
INTERIOR BIDE
S.M.S.
2-
J/'
FLAPS DENT OVER
1/2' PUNCHED
O
I
2' NN. wo NTO CONCRETE
1-7/8' MN. MCE DISTANCE
1 % 18 Da STEEL
B a1m D• mY yL[YY S�imgw'u V
) 1 IORK.
Ci TO PANELS WRN
]/1B' MOM
1-5/8' MN. EMBED INTO CONCRETE OR FlLLEO Bl
D
MOVE
BEE OETNL MOVE
MN. E00E DISTANCE INTO CONCRETE
4' MX
1' NN. EDGE DISTANCE INTO RUED BLOCK
EDGE
CONCRETE ER - 3000 PSI MIN.
DfSfANCE
0-00 GROUT IDir* BLOCK Vm - 2000 M MIN.
POP F7
el
JLYI!
7-1/2' X 3' X .071-J
ENO ROLLER HINGE
tar ERA. x .W
NYLON/STEEI ROLLERS
w/ .a Dw x a-1/a• s1EM
EAOR0
5 tT
e MR BRACKET mAFu+o
SS SOLT k NUT
a
01
I
C
$yy g1 r
g91d
4
b. "wmpI Tf18V49BD i Q
■�T wf®th EYKIaJ Rx
►�IusSi'•. �
,R� I�O" •: 8 8 0 8 �
a[1nN drawing m
01-09
etleat p OT 5
DOW HEWIT
CONSISTS OF
B-a
2 5F1'IWN9 1B•
a 5MAINS 2t
e-B
1 SECTION 19•
J SECTIONS 11
7
♦ SmroNS al"
-
J
>-
a 6Ecnpxs la.
♦ smlDxs e
I scmx 21
] 9EDMH9 to
z saTWx a
9-J•
1 6eCIgH5 tB•
] s6910N9 al
e-e
I SFLTWN ID
/ SEIMWNS St
e-B
a uDDDNs 2t
-
B
B SEMIONS IB
-
B-J
S 54TON9 iB
ON 21
B-B•
♦ sELTOKB to
T'. 1
B -B
J 6ECIIMS 18•WN9
21'IWN9
11•1
-J
1 BF2 IIV
110N9 21'I
-a
a SEMIMS 21
o-B
B 5WM"1TION
2111
a SECnIONS 1
ONS 21"11-]•
B6ECE M IWANS
2111-6•
JS�21'
3 SECTIONS la•WS
21"11-8•
2 SMaNSl
TIONS zlID
1 BECRONB I
7ION9 21•1
-]
SECDOI6 21
IS-9°
a SEOTIMA 1wITON9
21"11Z
S SECTIONS IWWIIS
21'1J
ASECTIONS 1B
. BI•
13-S
J SELTON9 to
a SF:MWN9 11
J-B•
2 SECTIONS 1
B SFWTION9 2"
IJ-B'
1 SEC ON 1B"
T SECTIONS 11"
I/
B SEMION9 21
p-J
0 SECTIONS t
J SRaONs 21•
14-B
0 SECTIONS 18'
4 6EVVT0 21'
14-8
/ SELTIONS 1
0 9E'C11013t 21
1J'
J 9E000N9.1
a SFLRDAN 21"
IS-]•
1 SECTIONS 1B•
T SFCTRNJ al
le'-e
1 SECTION 1V
a SFWIIGV$ 21'
to-B
S SECTIONS 11
-
18
B S ON9 1B
/ SECHON9 21•
7-1/2' X 3• X .07f' CALV. ST
END ROUFR HAD
W/ (a) i 14 x B/D• SM
o ADE(ai
N. LOCK
12 REMRI
W iG IN. 5 T01 1 SAFETY iACfOfl O LtBN V X0.1• I
WITH (2) 114 X 8 BPBMS 11 m
TOP EDLIIIRE 5-1/2' % 2-3/4° X 0.1"
STEEL PLATE WITH ONE SIB-18 LIS W/ NO
�,� �iASTFNFD TO FNO STILE OPODNAL DDOR VIEWER
��
ON��
E� li�ll II —II
'_II�II Il�i�
BRACKEF BRACKET
STD. LIFT DOOR LOW HEADROOM
DOOR OPTION
7-7 B° x 3-1/B' X .010'
PIATE
CENTER STIE-1 I� MR (4) /14 X 3/4- SIDE
STILE
w/� 1 ff LOCK BVi BAR
WSLUIEO ON END SRLE
WITH (4) p14 X S/B' SMS
Q 1BT % .SIN TRACK
BAR
ENGAGES IN TRACK
ON EACH SIDE OF POOR
OU7510E KE'ED LOOK
LOCK BAR LOCKINO SHOWN
ALTERNATE M LOOKS SHOWN ABOVE
INSIDE ELEVATION
RAISED PANEL EMBOSSED DOOR
DAB DOOR MODEL 824
MAX. SIZE 9'-4' WIDE X 10'-0" HIGH
DESIGN PRESSURE RATING a + 50.0 PSF
- 60.0 PSF
T
THIS PRODUCT IS RATED FOR LARGE MISSILE IMPACT S 74 B ^ =
@0m
GENERAL NOTES
L THIS PRODUCT INS BEEN DWRINED AND TESTED TO COMPLY WITH THE T
REOLAHZEMENIS OF THE FLARDA BUIDWO CODE W10 ENRION INCLUDINGW4,511
MPIIODUCI'RRVgEOHDH VELOCITY HURRICANE ZONE. ' Z' BMf2 ANCHORS SKALL BE AS LISTED, SPACED AS SHOWN ON DETAILS.ANCHOR EMBEDMENT TO WE MATERIAL SHALT. BE BEYOND WALLDRESSING OR SIUCCO.ALE BOLTS, NI11S AND WASHERS SNALL BE ZINC PLATED CARBON STEEL.4, ANCHORING OR LOADING CONDI IONS OTHER THAN THOSE SHOWN IN3 A L�MOD�TIONN NOAn OSE IS IISM IN DE OF ANCHORS PBD WOW ONLY. � 01-09
teti—�1