Loading...
HomeMy WebLinkAboutFLORIDA ENERGY EFFICIENCY CODESGANNLD BY St. Lucie County FORM 405-10 ,FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 62' WYNNE GRAND CARLTON Builder Name: COMFORT CONTROL OF SLC, INC. Street: \Qll „ Permit Office: City, State, Zip: , FL, - Permit Number: Owner: GRAND CARLTON 62' Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (1514.5 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.3 1514.50 ft' b. N/A R= ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. N/A R= ft' 10. Ceiling Types (1445.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1446.00 ft2 6. Conditioned Floor area above grade (ft') 1446 b. NIA R= ft' c. NIA R= Conditioned floor area below grade (ft') 0 11. Ducts R ft' 7. Windows(114.0 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 90 a. U-Factor: Dbl, U=1.30 114.00 ft' SHGC: SHGC=0.50 ft. 12. Cooling systems kBtu/hr Efficiency b. U-Factor: N/A a. Central Unit 28.2 SEERA5.00 SHGC: c. U-Factor: NIA ft. SHGC: 13. Heating systems kBtu/hr Efficiency d. or: NIA ft' SHGC: SHGC a. Electric Heat Pump Area Weighted Average Overhang Depth: 3.833 ft. FILE Area Weighted Average SHGC: 0.500 14. Hot water syste a. Electric Cap: 40 gallons 8. Floor Types (1446.0 sgft.) Insulation Area EF: 0.900 a. Slab -On -Grade Edge Insulation R=0.0 1446.00 ft' b. Conservation features b. N/A R= ft. None c. N/A R= ft' 15. Credits CF, Pstat Total Proposed Modified Loads: 26.16 PASS Glass/Floor Area: 0.079 Total Standard Reference Loads: 32.81 I hereby certify that the plans and specifications covered by Review of the plans and o�SHE ST�6 this calculation are in co liance with the Florida Energy specifications covered by this indicates 1 _ : , O� Code. calculation compliance `a with the Florida Energy Code. urrr .= ''•• .-ir' ,'. O PREPARED By, _ Before construction is completed I O ) DATE: this building will be inspected for O C y compliance with Section 553.908 f a 1 hereby that this building, as desig d, is' mpliance Florida Statutes. certify with the Florida Energy Code. COO WE OWNER/A T: DATE: BUILDING OFFICIAL: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 403.2.2.1.1. - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 5/15/2012 9:20 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 PROJECT • Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: 62' WYNNE GRAND CARLT FLProp2010 GRAND CARLTON 62' 1 COMFORT CONTROL OF SL Single-family New (From Plans) Bedrooms: 2 Conditioned Area: 1446 Total Stories: 1 Worst Case: No Rotate Angle: 45 Cross Ventilation: No Whole House Fan: No Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address ST. LUCIE FL, - CLIMATE Design Location TMY Site IECC Design Temp Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Heated 1 RoomslnBlockl 1446 11568 Yes 2 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulalio RoomslnBlockl 150.7 ft 0 1446 ft' ---- 0 0 1 ROOF ` / V # Type Materials Roof Gable Roof Area Area Color Solar Absor. SA Emitt Tested Emift Deck Tested Insul. Pitch (deg) 1 Hip Metal 1523 ft' 0 ft' Medium 0.88 N 0.9 No 0 18.4 ATTIC / 'v# Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1445 ft' N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) RoomslnBlockl 30 1446 ft' 0.1 Wood 5/1512012 9:20 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Mt Tn Wall-lype Space R-Vn[Ue Ft In Ft In A,. R Value-Eractlon--Abs0 1 N Exterior Concrete Block - Int InsQaomslnBloc 4.3 32 2 9 10 316.3055 0 0 0.8 0 2 E Exterior Concrete Block - Int InsNoomslnBloc 4.3 49 11 9 10 490.8472 0 0 0.8 0 3 S Exterior Concrete Block - Int InsRoomslnBloc 4.3 15 6 8 0 124 ft2 0 0 0.8 0 4 SW Exterior Concrete Block - Int InsRoomslnBloc 4.3 4 3 8 0 34 ft- 0 0 0.8 0 5 W Exterior Concrete Block - Int InsBloomslnBloc 4.3 35 2 8 0 281.3333 0 0 0.8 0 6 W Exterior Concrete Block - Int InsRoomslnBloc 4.3 8 0 8 0 64 ft' 0 0 0.8 0 7 S Exterior Concrete Block - Int Ins61oomsInBIoc 4.3 25 6 8 0 204 ft2 0 0 0.8 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S=>E Insulated RoomslnBloc Metal 0.6 3 0 7 0 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Int Shade Screening 1 N=>W 1 Metal Double (Tinted) Yes 1.3 0.5 N 27 ft2 10 ft 0 in 0 ft 6 in HERS 2006 None 2 N=>W 1 Metal Double (Tinted) Yes 1.3 0.5 N 15 ft- 1 ft 0 in 0 ft 6 in HERS 2006 None 3 N=>W 1 Metal Double (Tinted) Yes 1.3 0.5 N 15 ft- 1 ft 0 in 0 ft 6 in HERS 2006 None 4 E=>N 2 Metal Double (Tinted) Yes 1.3 0.5 N 20 ft2 1 ft 0 in 0 ft 6 in HERS 2006 None 5 E=>N 2 Metal Double (Tinted) Yes 1.3 0.5 N 15 ft2 1 It 0 in 0 ft 6 in HERS 2006 None 6 S=>E 3 Metal Double (Tinted) Yes 1.3 0.5 N 16 ft- 6 It 0 in 0 ft 6 in HERS 2006 None 7 W=>S 5 Metal Double (Tinted) Yes 1.3 0.5 N 6 ft2 1 ft 0 in 0 ft 6 in HERS 2006 None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 382.8 ft2 382.8 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 BySpaces Proposed SLA 0.000360 1365.4 74.960 140.97 0.2628 7.0821 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF: 8.6 28.2 kBtu/hr 1 sys#1 5/1512012 9:20 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 15 28.2 kBtu/hr 846 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 40 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / --- Supply ---- — Return ---- Air Percent HVAC # V # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF Heat Cool 1 Attic 6 g0 ft' Attic 25 ft' DSE=0.88 Attic 0.0 cfm 0.00 % 0.00 0.60 1 1 TEMPERATURES Thermostatrtt: Y ProgramablCo Ctfteiling Fans: ng[[e OliThermostat r[rr rrr Apr Jun X M:y[[[[ EE �EXX]] [[[[ �([[XXXXj] ��[�XXXXjJ Nov �[XC]] Dec Mar Apr May Jun Jul Aug Sep Occtt Nov Dec Venting [X� Jan [Xj Feb [XJ [X1 [X� [X� [X� lxJ [X1 lxl lxl lxJ Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 5/16/2012 9:20 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: PERMIT #: FL, - MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16113). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 5/15/2012 9:20 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 80 The lower the EnergyPerformance Index, the more efficient the home. „ FL, - 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.3 1514.50 ftz b. N/A R= ft 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. N/A R= W 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1446.00 ftx 6. Conditioned Floor area (ft-) 1446 b. N/A R= ft' c. N/A R= ft. 7. Windows— Description Area 11. Ducts R ft' a. U-Factor: Dbl, U=1.30 114.00 ft' a. Sup: Attic, Ret: Attic, AH: Attic 6 90 SHGC: SHGC=0.50 b. U-Factor: N/A ft. SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft' a. Central Unit 28.2 SEER:15.00 SHGC: d. U-Factor: N/A ft' 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 28.2 HSPF:8.60 Area Weighted Average Overhang Depth: 3.833 ft. Area Weighted Average SHGC: 0.500 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1446.00 ft2 a. Electric EF: 0.9 b. N/A R= ft' b. Conservation features c. N/A R= ft. None 15. Credits CF. Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Othe Ise, ew EPL Display Card will be completed based on installed Code compliant f to Builder Signature: Date: (� Address of New Home: —AKI City/FL Zip S �•�, *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software