HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEc c L tl C Planning & Development Services Department
_ Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: TARPON FLATS LOT 28 - MODEL A
Project Address: 3922 Duneside Drive Ft. Pierce, FL.
Permit #:
Type: R-3 Construction Type: VV=B
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
•
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
_ 1.
DESIGN CODE: Florida Building
Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2.
Structure Designed as (check one):
X Enclosed _Partially Enclosed _Open
3.
Risk Category: _I X II _III
_ IV Exposure Category: _B X C
_D
4.
Design Wind Velocity 170
mph _ASD _LRFD End Zone Width: 4.98
ft
5.
Mean Roof Height 15.44'
ft Roof Pitch: 6 :12 Parapet: -
ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1:-44.63 Zone 2: -74.76 Zone 3: -74.76 Zone 4:45.6 Zone 5:-57.8 Garage:
7. Design Loads: Floor: 138 PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: PSF
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? x Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2,500 PSF Soil Test Reports Submitted? X Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also ce�ityl Ithnitls rVctural elements depicted on these plans provide adequate resistance to the design
forces specific& NSU Gq
\\\ �O .• "" •. T ' Farid Abugattas PE 72471
Q\CENSF ..9�
(`P . Print Name Cert # & Co. Cert Auth.
2471 ; * _ Project Classic LLC
7318 Texas Trail Boca Raton FL 33487
SignaturQ , y�7{CTE OF
:HECKED OCT 17 n FCOR�O?• Company Name &Address un1J
Revised o7/25/�95O /ONA�-
r1riliillil��