Loading...
HomeMy WebLinkAboutFLORIDA EFFICIENCY CODEFORM R405-2014 SCANNED BY St. Lucie County FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ' 'Project Name: Lot28TarponFlatsModeIAGRW Builder Name: Phoenix Realty Homes Inc Street: 3922 Duneside Drive Permit Office: City, State, Zip: Fort Pierce , FL , Permit Number: 1511-0125 Owner: i Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (2081.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1745.30 ft' b. Frame - Wood, Adjacent R=13.0 336.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 4 d. N/A R= ft' 10. Ceiling Types (1976.0 sqft.) Insulation Area 5. Is this aworst case? No a. Roof Deck (Unvented) R=20.0 1976.00 ft= 6. Conditioned floor area above grade (ft-) 1976 b. N/A R= ft' Conditioned floor area below grade (ft') 0 c. R= 11. Ducts ft R ft' 7. Windows(421.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 395.2 a. U-Factor: Dbl, U=0.60 421.44 ft' SHGC: SHGC=0.32 b. U-Factor. N/A ft' 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 47.5 SEER:15.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 47.5 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 5.960 ft. Area Weighted Average SHGC: 0.320 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1976.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1976.00 ft' b. Conservation features b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.213 Total Proposed Modified Loads: 59.39 PASS Total Baseline Loads: 59.37 I hereby certify that the plans and specifications covered by Review of the plans and e tUEST,gr this calculation are in compliance with the Florida Energy specifications covered by this 0 Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed r DATE: Russell Henry December 18,2015 this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. !,), with the Florida Energy Code..GOD wmy"JR� OWNER/AGEN .Qha) BUILDING OFFICIAL: DATE: zzz DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.020 Qn for whole house. 12/18/2015 3:04 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 WO NW, 11b-0QlE1 PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot28TarponFlatsModelAGR User 1 Phoenix Realty Homes Inc Single-family New (From Plans) Bedrooms: 4 Conditioned Area: 1976 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Lot# Block/SubDivision: PlalBook: Street: County: City, State, Zip: Street Address 28 Tarpon Flats 3922 Duneside Drive St. Lucie Fort Pierce , FL, CLIMATE / V Design Location TMY Site IECC Design Temp Zane 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 1976 18376.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Healed 1 Main 1976 18376.8 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile - Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 187 ft 0 1976 W ---- „ 0.32 0 0.68 ROOF # Type Materials Roof Gable Roof Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 2210 ft' 0 ft' Medium 0.65 N 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented . 0 1976 ft' N N CEILING # Ceiling Type Space R-Value Area Framing Free Truss Type 1 Under Attic (Unvented) Main 0 1976 ft' 0.11 Wood 12/18/2015 3:04 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 N Exterior Concrete Block- Int Insul Main 4.1 33 6 9 41 312.7 ft2 0 0 0.6 0 _ 2 N Exterior Concrete Block - Int Insul Main 4.1 15 6 9 41 144.7 ft' 0 0 0.6 0 3 E Exterior Concrete Block - Int Insul Main 4.1 25 0 9 4 233.3 ft- 0 0 0.6 0, -4 E Exterior Concrete Block - Int Insul Main 4.1 18 0 9 4 168.0 ft2 0 0 0.6 0 5 E Exterior Concrete Block - Int Insul Main 4.1 16 0 9 4 149.3 ft2 0 0 0.6 0 6 S Exterior Concrete Block - Int Insul Main 4.1 25 6 9 4 238.0 fN 0 0 0.6 0 7 S Exterior Concrete Block - Int Insul Main 4.1 10 6 9 4 98.0 ft2 0 0 0.6 0 8 S Exterior Concrete Block - Int Insul Main 4.1 6 0 9 4 56.0 ft2 0 0 0.6 0 _ 9 W Exterior Concrete Block - Int Insul Main 4.1 18 6 9 4 172.7 ft2 0 0 0.6 0 10 W Exterior Concrete Block - Int Insul Main 4.1 6 6 9 4 60.7 ft2 0 0 0.6 0 _ 11 W Exterior Concrete Block - Int Insul Main 4.1 12 0 9 4 i 112.0 ft2 0 0 0.6 0 _ 12 - Garage Frame - Wood Main 13 36 0 9 4 i 336.0 ft2 0 0.23 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Area Ft In FHeightln Wood Main None .I39 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall I Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Double Yes 0.6 0.32 13.3 ft2 2 ft 0 in 0 ft 5 in None None 2 N 1 Metal Low-E Double Yes 0.6 0.32 26.7ft2 2 it 0 in 0 ft 5 In None None 3 E 3 Metal Low-E Double Yes 0.6 0.32 50.7 f12 2 ft 0 in 0 ft 5 in None None 4 E 3 Metal Low-E Double Yes 0.6 0.32 38.0 ft2 2 ft 0 in 0 ft 5 in None None 5 E 4 Metal Low-E Double Yes 0.6 0.32 96.0 f12 13 ft 0 in 0 ft 5 in None None 6 E 5 Metal Low-E Double Yes 0.6 0.32 33.8 f12 2 ft 0 in 0 ft 5 in None None 7 E 5 Metal Low-E Double Yes 0.6 0.32 31.7 ft2 2 ft 0 in 0 If 5 in None None 8 S 6 Metal Law-E Double Yes 0.6 0.32 6.3 fN 2 ft 0 in 0 ft 5 in None None 9 S 7 Metal Low-E Double Yes 0.6 0.32 20.0 ft2 I 18 ft 8 in 0 ft 6 in None None 10 W 9 Metal Low-E Double Yes 0.6 0.32 8.3 ft2 2 ft 0 in 0 It 5 in None None 11 W 9 Metal Low-E Double Yes 0.6 0.32 31.0 ft2 2 ft 0 in 0 ft 5 in None None 12 W 10 Metal Low-E Double Yes 0.6 0.32 24.0 ft2 9 ft 2 in 0 ft 8 In None None 13 W 10 Metal Low-E Double Yes 0.6 0.32 10.7 ft2 9 ft 2 in 0 It 2 in None None 14 W 11 Metal Low-E Double Yes 0.6 0.32 31.0 ft2 3 ft 0 in 0 ft 2 in None None 12/18/2015 3:04 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 483 ft' 384 ft' 80.75 ft 9.3 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000295 1531.4 84.07 158.11 .2157 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 47.5 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 47.5 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type Subtype Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.95 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Can # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS v # --- Supply — Location R-Value Area --- Return — Air CFM 25 CFM25 HVAC # Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 395.2 ft Attic 98.8 ft' Proposed On Attic -- cfm 39.5 cfm 0.02 0.60 1 1 12/18/2015 3:04 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 Pr1RNA PAnF_gnlA TEMPERATURES Progremablre Thermostar[t:�]Y Crreiling Fans: Heating [X] Jan Feb r[ Mar [ ] L 1 AApr �X� Jun f rl Jul ( ri Aug r rl Sep Oct Nov rr Dec Dec Venfing Il 1111 Jan [[[[ 1111 Feb l l [[[X Mar l lxl [ May Jun l Jul 111 Aug 111 Sep X [ Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Healing (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 12/18/2015 3:04 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple,family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned Floor area (ft2) 7. Windows" Description a. U-Factor: Dbl, U=0.60 SHGC: SHGC=0.32 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A ,SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a..Slab-On-Grade Edge Insulation b. N/A c. N/A 3922 Duneside Drive, Fort Pierce, FL, New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1745.30 112 b. Frame - Wood, Adjacent R=13.0 336.00 ft 1 c. N/A R= ft2 4 d. N/A R= ft2 10. Ceiling Types Insulation Area NO a. Roof Deck (Umiented) R=20.0 1976.00 ft2 1976 b. N/A R= ft2 Area c. N/A R= ft2 421.44 ft2 11. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 395.2 ft2 12. Cooling systems kBlu/hr Efficiency ft2 a. Central Unit 47.5 SEER:15.00 ft2 5.960 ft. 0.320 Insulation Area R=0.0 1976.00 ft2 R= ft2 R= ft2 13. Healing systems a. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: ia�P�h Address of New Home: 39aa DCity/FL Zip: kBtu/hr Efficiency 47.5 HSPF:8.50 Cap: 50 gallons EF: 0.95 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12/18/2015 3:04 PM EnergyGauge® USA- FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot28TarponFlatsModeIAGRW Builder Name: Phoenix Really Homes Inc Street: ' 3922 Duneside Drive Permit Office: City, State, Zip: Fort Pierce , FL , Permit Number. 1511-0125 Owner: , ' Jurisdiction: Design Location: FL, Fort Pierce i 1. New construction or existing New (From Plans) 9. Wall Types(2081.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Inl Insul, Exterior R=4.1 1745.30 ft2 b. Frame - Wood, Adjacent R=13.0 336.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft: 10. Ceiling Types (1976.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1976.00 ft2 6. Conditioned floor area above grade (ft2) 1976 b. N/A R= ft2 c. NIA R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts - R ft2 7. Windows(421.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic - 6 395.2 a. U-Factor: Dbl, U=0.60 421.44 ft2 SHGC: SHGC=0.32 b. U-Factor: - N/A ft2 12. Cooling systems kBtu/hr , Efficiency SHGC: - a. Central Unit 47.5 SEER:15.00 c. U-Factor. N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 47.5 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 5.960 ft. Area Weighted Average SHGC: 0.320 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1976.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1976.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Patel Glass/Floor Area: 0.213 Total Proposed Modified Loads: 59.39 PASS Total Baseline Loads: 59.37 1 hereby certify that the plans and specifications covered by Review of the plans and F'CSE SrAr this calculation are in compliance with the Florida Energy specifications covered by this�� Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: DATE: Russell Henry December 18,2015 Before construction is completed this building will be inspected for compliance with Section 553.908 0 I hereby certify that this building, as designed, is in compliance Florida Statutes. J� cOD with the Florida Energy Code. Wr,'SR� OWNER/AGENT: /A W BUILDING OFFICIAL: DATE: L Fl - Z015 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.020 an for whole house. 12/18/2015 3:04 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 A FORM R405-2014 PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot28TarponFlatsModelAGR User 1 Phoenix Realty Homes Inc Single-family New (From Plans) Bedrooms: 4 Conditioned Area: 1976 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address 28 Tarpon Flats 3922 Duneside Drive St. Lucie Fort Pierce , FL , CLIMATE / V Design Location TMY Site IECC Design Temp Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockt 1976 18376.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1976 ' 18376.8 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulalio Main 187 it 0 1976 ft' ____ 0.32 0 0.68 ROOF / V # Type Materials Roof Gable Roof Area Area Color Solar Absor. SA Emift Tested Emift Deck Pitch Tested Insul. (deg) 1 Hip Metal 2210 112 0 ft2 Medium 0.65 N 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 In) Area RBS IRCC 1 Full attic - Unvented 0 1976 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Unvented) Main 0 1976 ft2 0.11 Wood 12/18/2015 3:04 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 v FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 N Exterior Concrete Block - Int Insul Main 4.1 33 6 9 4 312.7 ft' 0 0 0.6 0 -2 N Exterior Concrete Block - Int Insul Main 4.1 15 6 9 4 144.7 ft' 0 0 0.6 0 _ 3 E Exterior Concrete Block - Int Insul Main 4.1 25 0 9 4 233.3 ft2 0 0 0.6 0 -4 E Exterior Concrete Block - Int Insul Main 4.1 18 0 9 4 168.0 ft' 0 0 0.6 0 _ 5 E Exterior Concrete Block - Int Insul Main 4.1 16 0 9 4 149.3 ft2 0 0 0.6 0 _ 6 S Exterior Concrete Block - Int Insul Main 4.1 25 6 9 4 238.0 ft2 0 0 0.6 0 _ 7 S Exterior Concrete Block - Int Insul Main 4.1 10 6 9 4 98.0 ft' - 0 0 0.6 0 -8 S Exterior Concrete Block - Int Insul Main 4.1 6 0 9 4 56.0 ft2 0 0 0.6 0 9 W Exterior Concrete Block - Int Insul Main 4.1 18 6 9 4 172.7 ft2 0 0 0.6 0 _ 10 W Exterior Concrete Block - Int Insul Main 4.1 6 6 9 4 60.7 fie 0 0 0.6 0 _ 11 W Exterior Concrete Block - Int Insul Main 4.1 12 0 9 4 112.0 ft' 0 0 0.6 0 12 - Garage Frame - Wood Main 13 36 0 9 4 336.0 112 0 0.23 0.3 0 DOORS # Oml Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 - Wood Main None .39 2 8 8 21.3 ft2 WINDOWS - Orientation shown is the entered, Proposed orientation. ' / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Double Yes 0.6 0.32 13.3 ft2 2 ft 0 in 0 ft 5 in None None 2 N 1 Metal Low-E Double Yes 0.6 0.32 26.7 ft' 2 ft 0 in 0 ft 5 in None None 3 E 3 Metal Low-E Double Yes 0.6 0.32 50.7 ft2 2 ft 0 in 0 ft 5 in None None 4 E 3 Metal Low-E Double Yes 0.6 0.32 38.0 ft' 2 ft 0 in 0 ft 5 in None None 5 E 4 Metal Low-E Double Yes 0.6 0.32 96.0 ft' 13 ft 0 in 0 ft 5 in None None 6 E 5 Metal Low-E Double Yes 0.6 0,32 33.8 ft' 2 ft 0 in 0 ft 5 in None None 7 E 5 Metal Low-E Double Yes 0.6 0.32 31.7 ft' 2 ft 0 in 0 ft 5 in None None 8 S 6 Metal Low-E Double Yes 0.6 0.32 6.3 112 2 ft 0 in 0 ft 5 in None None 9 S 7 Metal Low-E Double Yes 0.6 0.32 20.0 ft' 18 ft 8 in 0 ft6 in None None 10 W 9 Metal Low-E Double Yes 0.6 0.32 8.3 ft2 2 ft 0 in 0 ft 5 in None None 11 W 9 Metal Low-E Double Yes 0.6 0.32 31.0 ft2 2 ft 0 in 0 ft 5 in None None 12 W 10 Metal Low-E Double Yes 0.6 0.32 24.0 ft2 9 ft 2 in 0 ft 8 in None None 13 W 10 Metal Low-E Double Yes 0.6 0.32 10.7 ft' 9 ft 2 in 0 ft 2 in None None 14 W 11 Metal Low-E Double Yes 0.6 0.32 31.0 fl2 3 ft 0 in 0 ft 2 in None None 12/18/2015 3:04 PM EnergyGauge® USA - FlaRes2014 Section R405.4,1 Compliant Software Page 3 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Dbl, U=0.60 SHGC: SHGC=0.32 b. U-Factor: N/A SHGC: c. U-Factor. N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 3922 Duneside Drive, Fort Pierce, FL, New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block- Inl Insul, Exterior R=4.1 1745.30 ft2 b. Frame - Wood, Adjacent R=13.0 336.00 112 1 c. N/A R= ft2 4 d. N/A R= ft' 10. Ceiling Types Insulation Area No a. Roof Deck (Unvented) R=20.0 1976.00 ft2 1976 b. N/A R= ft2 Area c. N/A R= ft' 421.44 ft2 11. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 395.2 ft2 12. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 47.5 SEER:15.00 ft2 5.960 ft. 0.320 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 .1976.00 112 b. N/A R= ft2 c. N/A R= ft' 13. Heating systems a. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building , Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: J Date: Address of New Home: a City/FL Zip: kBtu/hr Efficiency 47.5 HSPF:8.50 Cap: 50 gallons EF: 0.95 Pslal *Note: This is not Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12118/2015 3:04 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 06P.4 TO"Y11I.& IIEI GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 483 ft- 384 ft' 80.75 ft 9.3 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000295 1531.4 84.07 158.11 .2157 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 47.5 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 47.5 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type Subtype Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.95 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Carl # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS / V # -- Supply--- Location R-Value Area — Return--- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 395.2 ft Attic 98.8 ft- Proposed On Attic -- cfm 39.5 cfm 0.02 0.60 1 1 12M 8/2015 3:04 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 TEMPERATURES Programablre,Thermostat: Ceiling Fans: Heating t Jan �Y I Feb Mar Apr Apr € May May rl Jun Jul [X� [ ] ADec ug [ [X� Sep Oct H Nov rr J� Dec Venting [[[ 111 Jan III 111 Feb X Mar Jun 1111 Jul l l l) Aug l Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78. 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68. 68 68 68 68 68 68 66 66 12/18/2015 3:04 PM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5