HomeMy WebLinkAboutFIRE DOCSAINT LUCIE COUNTY FIRE DISTRICT
PLAN REVIEW FORM
SCANNED
fGOUNTy
V
3
5160 N.W. Milner Drive
Port Saint Lucie, FL 2
`� LUCle CQUngl
ix x
Telephone:772-621-33-3322
Fax: 772-621-3604
Web Address: www.slcfd.com,
„Building Dept. Saint Lucie County FMO Permit# B-19-107
Project Name CVS Pharmacy- Stockroom Remodel BLDG Permit# 19D2-0379
Address 4780 North King's Highway City Fort Pierce
Contractor Vision Contractors Inc
Address 95 Old Dixie Hwy City Adairsville
State GA Zip 30103 Telephone (770) 769-4674
Architect/Engineer Istefano DeLuca
Occupancy Type Mercantile Class'B' Construction
.Occupant Load
Telephone 954.927.2690
Number of Stories I� Access Box
1.
AFS Permit FA Permit FFP Permit
General Notes
Square Feet 10700
Access Key Switch F
1. An electronic copy of the construction documents submitted on CD Is required. The file format shall be .pdf only.
2. All revisions, including the electronic copy mustbe received prior to permitting.
3. The Fire Marshal requires 24 hour notice on all Inspections.
4. The respective Building Department shall schedule all final Inspections through the Fire Marshal's Office.
S. Failed inspections require payment of fee prior to rescheduling of further inspections.
6. Penetrations through rated assemblies shall be of the proper UL design, Design criteria shall besubmitted with the construction plans.
7. Fire alarm panels shall be located indoors within air conditioned space.
B. Plans and construction are subject to corrections in the field to maintain code compliance.
9. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 ctm design capacity.
10. The Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed Fire Protection Systems require a separate review and permit.
THE FLORIDA FIRE PREVENTION CODE, 2010 EDITION IS CURRENTLY ENFORCED.
BUILDINGS WITH LIGHT-FRAMETRUSS-TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVED FIREFIGHTER SAFETY
WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING
A CERTIFICATE OF OCCUPANCY.
See General Notes Above and
All existing life safety equipment shall be in proper working condition.
Below
Pagel' of 1' Reviewed by TonyJerger Date 04-1 19