Loading...
HomeMy WebLinkAboutREPORT OF BUILDING MATERIAL SURVEYSCANNED BY St. Lucie County AirQuest Project #14666 mited Interior Pre -Renovation Report Building Material Survey, ,,Samptnq and Evaluation Asbestos- ontaining Mai Stock Room CVS Store #5151 4780 North Kings Highway Fort Pierce, Florida 34951 Prepared For: Mr. Bill Hellman State Permits, Inc. 319 Elaines Court November 30,2018 AIR VEST® ENV IRON MENTAL, INC. 6851 Southwest W Street, Fort Lauderdale, FL 33314 Phone (954) 792-4549 ax: (954) 792-2221 www.AhQuestlnc.com RECEIVER FEB 2 0 2019 ST. Lucie County, Permitting AIAeVEST' ENVIRONMENTAL,INC. 6851 Southwest 45th Street Fort Lauderdale, FL 33314 Phone: 954/792-4549 Fax: 954/792-2221 Stop at First Positive: Yes/ No Turnaround Time: 3 Hr._; 6 Hr._ 24 Hr..X- 72 Hr. Other_ Email: Labresults@airquestinc:.com i JWID 43 Sample Date: % \ - \ \ - % 4 Project Name: S r g If e ee c `n 1+r c_ S I S 1 Project Number: +`r 6 6 6 Surveyor: Q q a a^ c Signature: HA ample Number HA Description Sample Location HA Location. uanti G/F/P ist. Pot. Friable Comments/Photo # \ S+51'o+ �Or•0Q C-0ovin '7j0, To G �- y \ r,%S.+.pti S•tC ooM Toi TO 6 L �{ 1 SiS+-os Sto'cwcoo..n 'To ' Tom• n"••t"wh\iev;r.y+ i,teGF<oorr` bcegkroom \io G G ' N i. S+Si-o5 ]Zo C G L N 1. Styi-oy �i.osE G N Sis1'o1 y" ca Vin +G�ootee�;n b<eaKtoom br6gKcoom 3l. \E 6 l_ N 3 S\S�-o4 vL t t G N 51St-\v yca Simv.,�deccoa bce ck xcoorn bc-e roorn `t SE G N N K StS+-+t y SF G L N S 5151'i corc<ete Looc sta'cycO0cn 9c1;r0.0M SvoSf G L N goose r+ S s+st IS S0050 6 L +" 6 sts+-+6 ��.:+e uGtm9 t'C St°�Kcooy�n SiocprOom %0r, 6 �- 6 StSt't1 So 5{ G t- Jf 14P 4o SG G L N Relinquished by: Received by: .Relinquished by: -Received by:`•�� q95 I391 M3 Date & Time: - Date & Time: 1 Date & Time: Date &Time: Initial =FedEx: =Hand Couriered Tracking # Page \ of1_ H W 0 v rr m a Appendix II Laboratory Report and Chain of Custody Record EMSL Analytical, Inc. 2700 W. Cypress Creek Rd. Ste. C108 Fort Lauderdale. FL 33309 Tel/Fax: (954) 786-9331 / (954) 941-4145 http://www.EMSL.com / pompanobeachlab@emsl.wm Attention: Paul LeBlanc AirQuest Environmental, Inc. 6851 Southwest 45th Street Fort Lauderdale, FL 33314 State Permits - 5151 - 14666 El..__ Jrder: 561806063 Customer ID: AQE63 Customer PO: Project ID: Phone: (954)214-2640 Fax: (954)792-2221 Received Date: 11/15/2018 1:00 PM Analysis Date: 11/15/2018-11/16/2018 Collected Date: 11/11/2018 Test Report. Asbestos Analysis of Bulk Materials via EPA 600IR-931116 Method using Polarized Light Microscopy Non -Asbestos Asbestos Sample Description Appearance % Fibrous %Non -Fibrous %Type 5151-01-Drywall Drywall System Brown/Beige 6%Cellulose 90% Non -fibrous (Other) None Detected Fibrous 2% Glass 561806063-0001 Homogeneous 5151-01-Joint Drywall System White 100% Non -fibrous (Other) None Detected Compound Non -Fibrous Homogeneous 5151-02-Drywall Drywall System Brown/Beige 15%Cellulose 82%Non-fibrous (Other) None Detected Fibrous 3%Glass 5616060640002 Homogeneous 5151-02Joint Drywall System White 100% Non -fibrous (Other) None Detected Compound Non -Fibrous Homogeneous 5151-03-Drywall 561806063-w03 5151-03Joint Compound Drywall System Brown/Beige 15%Cellulose Fibrous 3%Glass Drywall System White Nan -Fibrous Homogeneous 82% Non -fibrous (Other) None Detected 100% Non -fibrous (Other) None Detected 5618060630003A 5151-04-Vinyl Floor Tile Vinyl Floor Tile & Grey/White 100% Non -fibrous (Other) None Detected Mastic Non -Fibrous 5616ofio6a000a Homogeneous 5151-04-Mastic Vinyl Floor Tile & Yellow 100% Non -fibrous (Other) None Detected Mastic Non -Fibrous 561876063-0009A Homogeneous 5151-05-Vinyl Floor Tile Vinyl Floor Tile & Gray/White 100% Non -fibrous (Other) None Detected Mastic Non -Fibrous 561806061C005 Homogeneous 5151-05-Mastic Vinyl Floor Tile & Yellow 100% Non -fibrous (Other) None Detected Mastic Non -Fibrous 5151-06-Vinyl Floor Tile Vinyl Floor Tile & White 100% Non -fibrous (Other) None Detected Mastic Non -Fibrous 561$o6063-ON6 Homogeneous 5151-06-Mastic Vinyl Floor Tile & Yellow 100% Non -fibrous (Other) None Detected Mastic Non -Fibrous 5616a6961�oo6eA Homogeneous 5151-07-Cove Base Vinyl Floor Coving Gray 100% Nor-fibrous(Other) None Detected Non -Fibrous 561806069 7 Homogeneous 5151-07-Mastic Vinyl Floor Caving Beige 100% Non -fibrous (Other) None Detected Non -Fibrous 56160606i 07A Homogeneous 5151-08-Cove Base Vinyl Floor Coving Gray 100% Non -fibrous (Other) None Detected Non -Fibrous 5616060wco5e Homogeneous Inifial report from: 11/16/2018 12:26:26 ASS_PLM_0008_0001- 1.78 Printed: 11/16/2018 12:26 PM Page 1 of 2 I EMSL Analytical, Inc. El t.. _`)rder: 561806063 Customer ID: AQE63 2700 W. Cypress Creek Rd. Ste. C108 Fort Lauderdale, FL 33309 Customer PO: Tel/Fax: (954) 786-9331 / (954) 94141145 hftp://www.EMSL.mm/pompanobeachiab@eml.wm Project ID: Test Report: Asbestos Analysis of Bulk Materials via EPA 600IR-931116 Method using Polarized Light Microscopy Non -Asbestos Asbestos Sample Description Appearance % Fibrous %Non -Fibrous %Type 5151-08-Mastic Vinyl Floor Coving Beige 100% Non -fibrous (Other) None Detected Non -Fibrous 5elro6ofiofmceA Homogeneous 5151-09-Cove Base Vinyl Floor Caving Gray 100% Non -fibrous (Other) None Detected Non -Fibrous 5616060630009 Homogeneous 5151-09-Mastic Vinyl Floor Caving Beige 100% Non -fibrous (Other) None Detected Non -Fibrous 5151-10 Sink Undercoat Gray 20%Cellulose 80% Non -fibrous (Other) None Detected Non -Fibrous 5618061630010 Homogeneous 5151-11 Sink Undercoat Gray 20%Cellulose 80%Non-fibrous (Other) None Detected Non -Fibrous 5618060630011 Homogeneous 5151-12 Sink Undercoat Gray 20%Cellulose 80%Non-fibrous (Other) None Detected Non -Fibrous 5618060610012 Homogeneous 5151-13 Concrete Floor Grey 100% Non -fibrous (Other) None Detected Non -Fibrous 5151-14 Concrete Floor Grey 100% Non -fibrous (Other) None Detected Non -Fibrous 561606o6 14 Homogeneous 5151-15 Concrete Floor Gray 100% Non -fibrous (Other) None Detected Non -Fibrous 5151-16 Duct Mastic Tan/White/Silver 25%Cellulose 50% Non -fibrous (Other) None Detected Fibrous 15% Glass 5618060610016 Homogeneous 10%Wollastonite 5151-17 Duct Mastic White/Silver 5%Cellulose 85% Non -fibrous (Other) None Detected Non -Fibrous 10%Wollastonite 5616116,7630017 Homogeneous 5151-18 Duct Mastic Brown/Gray 5%Cellulose 85% Non -fibrous (Other) None Detected Fibrous 10%Wollastonite 561ee6063-0016 Homogeneous Analyst(s) Catalina Lachowski (18) John Polanco (9) Catalina Lachowski, Laboratory Manager or OtherApproved Signatory EMSL maintains liability limited to cost of analysis. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 "Interim Method), but augmented with procedures outlined in the 1993 ("final") version of the method. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. All samples received in acceptable condition unless otherwise noted. This report must not be used by the diem to claim product certification, approval, or endorsement by NVLAP, NIST oray agency of the federal gowmment. EMSL recommends gravimeVic reduction for all non friable organically bound materials prior to analysis. Eslimatondwcenaintyisavailableanr¢quest. Samples analyzed by EMSLAnalocal, Inc. Fort Lauderdale, FL NVLAP Lab Code 5000850 1 Initial report from: 11/16/2018 12:26:26 ASB_PLM 0008_0001- 1.78 Printed: 11/16/2018 12:26 PM Page 2 of 2 TABLE OF CONTENTS PAGE I EXECUTIVE SUMMARY 1 2 INTRODUCTION AND SITE DESCRIPTION 2 3 SURVEY METHODS AND LABORATORY ANALYSIS 3 4 SUSPECT ASBESTOS -CONTAINING MATERIALS 5 5 CONCLUSIONS 7 6 LIMUATIONS 8 TABLES Table 1 — Laboratory Analysis and Summary..............................................................................5 APPENDICES Appendix I — Certifications Appendix II — Laboratory Report and Chain of Custody Record iii AirQuest Environmental, Inc. EXECUTIVE SUMMARY AirQuest Environmental, Inc. ("AirQuest') performed a survey for asbestos -containing materials (ACM) at the Stock Room ofCVS Store #5151, located at 4780 North Kings Highway, Fort Pierce, Florida 34951 ("the site"). The survey was performed on November 11, 2018, by AirQuest Senior Project Manager, Mr. Paul LeBlanc, an EPA -accredited Asbestos Hazard Emergency Response Act (AHERA) Asbestos Inspector (see Appendix I). The purpose of the survey was to locate and identify ACM within building materials inside the Stock Room prior to renovation activities. The results of our observation and laboratory anal y is did not identify ACM in a samples collected from the site. At the request of the Client, the scope of the survey was limited to interior building materials to be impacted by upcoming renovation activities to the Stock Room. The remaining interior building materials/areas, the exterior and roof of the building were not included in the scope of the inspection. Destructive sampling procedures were not used to access the interior of wall cavities, fire doors, or above hard ceilings. If any materials are encountered during renovation activities that were not sampled in this report, the materials should not be disturbed until they have been sampled and identified as non -ACM through laboratory analysis. FEB 2 0 2019 ST. Luci=rmitting Project #14666 1 Asbestos Survey AirQuest Environmental, Inc. 2 INTRODUCTION AND SITE DESCRIPTION The Stock Room of CVS Store #5151, located at 4780 North Kings Highway in Fort Pierce, Florida, was a two-story space. At the request of the Client, the scope of the survey was limited to interior building materials to be impacted by upcoming renovation activities to the Stock Room. The remaining interior building materials/areas, the exterior and roof of the building were not included in the scope of the inspection. AirQuest conducted this survey in general accordance with the scope and limitations of National Emission Standards for Hazardous Air Pollutants (NESHAPs) and AirQuest's proposal number 14666 dated November 8, 2018. The scope of services for this project consisted of the following five steps: ➢ Building Walk -Through and Observations, ➢ Bulk Sampling of Suspect ACM, ➢ Polarized Light Microscopy (PLM) Analysis of Bulk Samples, ➢ Hazard Assessment and Evaluation, and ➢ Final Report Preparation. On November 11, 2018, AirQuest Senior Project Manager, Mr. Paul LeBlanc, conducted an asbestos sampling survey of suspect ACM associated with the pending renovations at the site The building was constructed of concrete block on a concrete slab foundation and was finished with stucco. The flat roof deck was constructed of corrugated metal. Ceilings were open to the roof deck and select areas were finished with drywall system. Interior walls were constructed of concrete block, plywood and drywall. The breakroom was finished with vinyl base cove. Floors were constructed of concrete. Break room floors were finished with vinyl floor tile. Mastic was present on the vinyl base cove and vinyl floor tile. White duct mastic was present on the ductwork. Project #14666 2 Asbestos Survey AirQuest Environmental, Inc. 3 SURVEY METHODS AND LABORATORY ANALYSIS The sampling protocol used generally follows AHERA guidelines. AHERA was promulgated by the United States Environmental Protection Agency (EPA) in 1987 and regulated public schools. Suspect materials are differentiated into three categories: surfacing material, thermal system insulation, or miscellaneous material. Surfacing material is anything that is sprayed or troweled onto a surface; thermal system insulation is material used to insulate HVAC pipes, tanks, etc., and miscellaneous material is any other type of material. During the survey, surfacing and miscellaneous materials were observed. A homogeneous area is defined as an area of surfacing material, thermal system insulation material, or miscellaneous material that is uniform in color and texture. A homogeneous area is not limited to only one room, but can be found in several rooms. Sample selection in the building was determined by identifying the homogeneous areas and basing sampling locations upon these areas. In conducting the building inspection in compliance with local, state, and federal regulations, all suspected ACM which were accessible to the inspector, were either sampled to confirm the actual presence of asbestos, or assumed to contain asbestos. Building areas between walls, under floors, under concrete slabs and above permanent ceilings, all of which could not be accessed, were not visually inspected nor were materials therein sampled as a part of this building inspection. Due to the fact that over 3,600 different building products are recognized as asbestos -containing building materials, it cannot be said that all such products, which may be present at the site, have or could be identified. Analysis was performed using Polarized Light Microscopy (PLM) with dispersion staining. The laboratory is rated proficient through National Institute of Standards and Technology- National Voluntary Laboratory Accreditation Program (MIST-NVLAP) for bulk asbestos analysis. It is important to note that the method of bulk sample analysis, PLM, is not 100% absolute in the identification of ACM. There are many factors which may contribute to false negatives being reported. Some of the more common factors include non -homogeneity of the building material and the optical variations of the microscopist. In order to obtain an absolute analysis of a building material, any reported negative sample suspect of being asbestos or any material not sampled should be analyzed by Transmission Electron Microscopy (TEM) with energy dispersive x-ray analysis (EDAX) for bulk sample confirmation. Interpretation of TEM results must be viewed with caution as these procedures are not presently recognized by EPA regulations. However, they are useful analytical techniques for confirmation of non -friable materials when PLM results are inconclusive. Project#14666 3 Asbestos Survey AirQuest Environmental, Inc. Because of the inherent limitations of PLM bulk sample analysis, the Owner may elect to re- analyze the reported negative PLM samples by TEM to determine whether they may be regulated under the asbestos NESHAP. This analytical technique is described in the EPA Guidance Document, EPA/600 R-93/116, July 1993, Test Method — Method for the Determination of Asbestos in Bulk Building Materials. This method, Analytical Electron Microscopy (AEM), also referred to as TEM, can often be a reliable method for the detection and positive identification of asbestos in some bulk building materials, both friable and nonfriable. The method is particularly applicable to bulk materials that contain a large amount of interfering materials that can be removed by ashing and/or dissolution and contain asbestos fibers that are not resolved by PLM techniques. Many floor tiles and plasters would be included in the type of sample. In combination with suitable specimen preparation techniques, the AEM method can also be used to quantify asbestos concentrations. The TEM analytical methodology is also referred to in an EPA Advisory, Federal Register, Vol. 59, No. 146, August 1, 1994, Advisory Regarding Availability of an Improved Asbestos Bulk Sample Analysis Sample Test Method; Supplementary Information on Bulk Sample Collection and Analysis. The Advisory states that this approach should be considered for the following circumstances: (1) Floor tiles which may contain thin fibers and which were analyzed under the 1982 PLM method and found not to be asbestos -containing; and (2) materials such as hard wall and acoustical plaster, stucco or other similar multi -layered materials or systems which were not analyzed and reported by layers (discrete strata). NESHAP, 40 CFR Part 763, Section 61.141, revised July 1, 1996, defines ACM as any material containing more than one (1) percent asbestos as determined using the method specified in Appendix E, Subpart E, 40 CFR Part 763, Section 1, PLM, that, when dry, can be crumbled, pulverized or reduced to a powder by hand pressure. If the asbestos content is less than ten (10) percent as determined by a method other than point counting by PLM, verify the asbestos content by point counting using PLM. Estimates of quantities of ACM where given are based upon the identification of suspect material where suspect ACM are located behind walls, above ceilings, beneath carpeting, or other concealed conditions. Where the quantities cannot be verified, the estimate is based upon the conditions present during the survey. These estimates are not to be considered absolute and should be verified when the ACM is exposed. Project #14666 4 Asbestos Survey AirQuest Environmental, Inc. 4 SUSPECT ASBESTOS -CONTAINING MATERIALS Six (6) homogeneous areas (HA) of suspect material were identified and a total of eighteen (18) samples were collected. The laboratory split the samples into layers, resulting in the analysis of twenty-seven (27) samples. Sample descriptions and laboratory results are summarized in Table 1. A copy of the laboratory report and chain of custody record is included in Appendix H. Table I — Laboratory Analysis and Summary Samples Collected on November 11, 2018 Sample 'Number Location Description_ of'Suspect Asbestos Content 5151-01 1 Breakroom Drywall System ND 5151-02 1 Stockroom Drywall System ND 5151-03 1 Stockroom Drywall System ND 12" x 12" White Vinyl 5151-04 2 Breakroom Floor Tile and Mastic ND 12" x 12" White Vinyl 5151-05 2 Breakroom Floor Tile and Mastic ND 12" x 12" White Vinyl 5151-06 2 Breakroom Floor Tile and Mastic ND 5151-07 3 Breakroom 4" Gray Vinyl Floor Coving ND and Mastic 4" Gray Vinyl Floor Coving 5151-08 3 Breakroom and Mastic ND 5151-09 3 Breakroom 4" Gray Vinyl Floor Coving ND and Mastic 5151-10 4 Breakroom Gray Sink Undercoat ND 5151-11 4 Breakroom Gray Sink Undercoat ND 5151-12 4 Breakroom Gray Sink Undercoat ND Project #14666 5 Asbestos Survey AirQuest Environmental, Inc. 5151-13 5 Stockroom Concrete Floor ND 5151-14 5 Stockroom Concrete Floor ND 5151-15 5 Stockroom Concrete Floor ND 5151-16 6 Stockroom White Duct Mastic ND 5151-17 6 Stockroom White Duct Mastic ND 5151-18 6 Stockroom White Duct Mastic ND HA- Homogenous Area ND- None Detected Project #14666 6 Asbestos Survey AirQuest Environmental, Inc. 5 CONCLUSIONS The results of our observation and laboratory analysis did not identify ACM within the samples collected from the site. Project 414666 7 Asbestos Survey AirQuest Environmental, Inc. 6 LIMITATIONS At the request of the Client, the scope of the survey was limited to interior building materials to be impacted by upcoming renovation activities to the Stock Room. The remaining interior building materials/areas, the exterior and roof of the building were not included in the scope of the inspection. Destructive sampling procedures were not used to access the interior of wall cavities, fire doors, or above hard ceilings. If any materials are encountered during renovation activities that were not sampled in this report, the materials should not be disturbed until they have been sampled and identified as non -ACM through laboratory analysis. This report was prepared in a manner consistent with that level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions. This report was prepared for the exclusive use of the client and assigned agents and is not intended for any other purposes. Our report is based on the information available to us at the time of our investigation and limited in scope to the stated purpose and/or the area(s) inspected. Other conditions elsewhere in the site may differ from those in the inspected/ surveyed locations and such conditions are unknown, may change over time, and/or have not been considered. This report does not claim to identify all potential hazards and/or contaminants that may be present, nor does it imply any medical opinion on the relationship of potential health effects with any reported hazards and/ or contaminants. Our opinions are based on our findings and professional expertise, with no guaranty or warranty implied herein. The data obtained in this report does not establish the habitability of the site, nor does it determine if a building is safe or unsafe. Should additional information become available, we reserve the right to determine the impact, if any, of the new information on our opinions, conclusions, and recommendations if necessary as warranted by the discovery of the additional information. AirQuest accepts no responsibility for interpretation of this report by others. Its contents shall not be used or relied upon by other parties without prior written authorization by AirQuest. Project #14666 8 Asbestos Survey Appendix I Certifications Air Quest Environmental.- 6861,SQuthw6sf45th Street -Tort Lauderdale, Fi6iida,33314 Has 661nibleted douk§ewotk and satisfactorily passed an, 63(kWhation that Meets all cfitetM, red&6d for, EPAIAHEWAS,HANRA M3qA Tit/611) 4pprovpdReaccreditation Asbestos in Buildings; InspectorRefr6sher p6mms. Date' junig; 7, -2 . 01-8 -Examinat-ion Date June 6, 2Q19 Expiration Date 16889. Certificat& Number Training Location: 6861 Southwest 45th;Sti6ei -fort Lauderdale, Florida 33314 (ApprovedIf! I t -Approval #.11--677) ,b� the A13114'CerU c'StIon.Mainteriahce Coni.initfedf-brI 2 CM,poin (Fi6r!ditPr6viderRegisteatidn.Niiiiib.beFL49-OOD1342-Cburs6-#FL49-0002805), k, `TEI-184IWest ,Oap�ar-kway,,Sbitb�F--,-M,ari6t'ti,6e6rgia, . 30 .062 - (770)42 - 7-3600 T vmwA6I[;aiil.cbrn CERTIFICATION PAGE Limited Interior Pre -Renovation Report of Building Material Survey, Sampling and Evaluation of Asbestos -Containing Materials Stock Room CVS Store #5151 4780 North Kings Highway Fort Pierce, Florida 34951 AirQuest Project #14666 Prepared For: Mr. Bill Hellman State Permits, Inc. 319 Elaines Court Dodgeville, Wisconsin 53533 Prepared By: AirQuest Environmental, Inc. 6851 Southwest 45th Street Fort Lauderdale, Florida 33314 Paul LeBlanc Senior Project Manager L E�Vf^D 0 2019nty, Permitting Traci -Anne Boyle, CIH, CSP FL Asbestos Consultant #AX-60 November 30, 2018 ii