Loading...
HomeMy WebLinkAboutMISCM-C11AM 0L, Planning & Developmental Services Department 0 '# '�'>""-•'v" `.. Huilding Q. :::ode Regulations Division Lan€ d SCANNED By SECTION 1008 MEANS OF EGRESS ILLUMINATION St. Lucie County 1008.1 Means of egress illumination. Illumination shall be provided in the means of egress in accordance with Section 1008.2. Under emergency power, means of egress illumination shall comply with Section 1008.3. SECTION 1010 DOORS, GATES AND TURNSTILES 1010.1 Doors. Means of egress doors shall meet the requirements of this section. Doors serving a means of egress system shall meet the requirements of this section and Section 1022.2. Doors provided for egress purposes in numbers greater than required by this code shall meet the requirements of this section. For accessibility provisions related to doors, refer to the Florida Building Code, Accessibility. Means of egress doors shall be readily distinguishable from the adjacent construction and finishes such that the doors are easily recognizable as doors. Mirrors or similar reflecting materials shall not be used on means of egress doors. Means of egress doors shall not be concealed by curtains, drapes, decorations or similar materials. 1010.1.1 Size of doors. The required capacity of each door opening shall be sufficient for the occupant load thereof and shall provide a minimum clear width of 32 inches (813 mm). Revised 2; 261!9 FILE COPY