HomeMy WebLinkAboutDOOR REPLACEMENT PLAN'103 —O 1 O -1
ST. LUCIE COUNTY
BUILDING DIVISIO
REVIEWED
FOR C08A N
REVIEWED ISY
DATE
LANS AND PERMI
MUST BE KEPT ON JO OR
NO INSPECTION WILL BE MADE
THESE PLANS AND ALL PROPOSCO VIO I K
ARE SUBJECT TO ANY CORRECT ION
REQUIRED BY FIELD INSPECTORS TH`
MAY BE NECESSARY IN ORDER TO
CCff PLY WI T H ALL APPLICABLE CODES 36" X 80"
t)NCEALED FASTENERS ORA17ACHMENTS
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OF RECORD I —
RECEIVED
MAR 0 6 2018
PerSt. Luelo ee n yant
SCANNED
BY
St. Lucie Countv
REPLACE DOOR IN 1 OPENING ONLY.
NEW DOOR TO BE IMPACT RESISTANT -
HURRICANE SHUTTERS NOT REQUIRED.
OPENING
PRODUCT
DESIGN
OPENING
SQ.
I
I WIND
I PRESSURES
APPROVAL
PRESSURES
COMMENTS
NO. WDTH. HGT.
FTG.
ZONE
POS. NEG.
(N.O.A. #)
POS. NEG.
1 1 36 80
20.01
4
55.2 1 -58.1
FL15210.1
75.0 1 -75.0
FRONT ENTRY - LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
LESS THAN 30% OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING. EXEMPT FROM 2017 ENERGY CONSERVATION CODE.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT = 96 FT 4 IN
SASZ CONDO UNIT
5167 N. HIGHWAYAIA, UNIT 801
FORT PIERCE, FLORIDA
DOOR REPLACEMENT PLAN