Scope: Product Evaluation report issued by R W Building Consultants, Inc, & Lyndon F. Schmidt, P.E. (System ID # 1998) for
Plastpro Inc., based on Rule Chapter No. 61G20-3, Method 1 D of the State of Florida Product Approval, Department of
Business & Professional Regulation.
RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of the product named
herein.
Limitations:
1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements
including the "High Velocity Hurricane Zone".
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing
or stucco.
3. When used in the "HVHZ" this product complies with Section 1626 of the Florida Building Code and does not require an impact
resistant covering.
4. When used in areas outside of the "HVHZ" requiring wind borne debris protection this product complies with FBC Sections 1609.1.2 &
R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as
defined in ASTM E 1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1.
5. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction.
6. Site conditions that deviate from the details of drawing FL-15210.1 require further engineering analysis by a licensed engineer or
registered architect.
7. Outswing configurations meet water infiltration requirements for "HVHZ". All other configurations do not meet the water infiltration
requirements for the "HVHZ" and must be installed only in non -habitable areas or at habitable locations protected by an overhang or
canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees.
8. See drawing FL-15210.1 for size and design pressure limitations
Supporting Documents:
1. Test Report No.
Test Standard
TEL 01390365
TAS 201-94, 202-94 & TAB 203-94
TEL 01391846
TAB 201-94, 202-94 & TAS 203-94
ETC-05-255-16776.0
ASTM D 635-98. 638-03, 1929-96 & 2843-99
ASTM G 26-95
ETC-06-255-17412.0
ASTM E 84-05
ETC-07-209-19303.0
ASTM D 635-98, 638-03, 1929-96 & 2843-99
2. Drawing No. Prepared by
No. FL-15210.1 RW Building Consultants, Inc. (CA #9813)
3. Calculations Prepared by
Anchoring RW Building Consultants, Inc. (CA #9813)
4. Quality Assurance
Certificate of Participation issued by National Accreditation and Management
Institute, certifying that Plastpro, Inc. is manufacturing products within a quality
assurance program that complies with ISO/IEC 17020 and Guide 53.
Sheet 1 of 1
Testing Laboratory
Testing Evaluation Lab., Inc.
Testing Evaluation Lab., Inc.
ETC Laboratories
ETC Laboratories
ETC Laboratories