Loading...
HomeMy WebLinkAboutPRODUCT EVALUATION REPORTR W R W Building Consultants', aic. BConsulting and Engineering Services for the Building Industry C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No. 9813 SCANNED BY St. Lucie County Scope: Product Evaluation report issued by R W Building Consultants, Inc, & Lyndon F. Schmidt, P.E. (System ID # 1998) for Plastpro Inc., based on Rule Chapter No. 61G20-3, Method 1 D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements including the "High Velocity Hurricane Zone". 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVHZ" this product complies with Section 1626 of the Florida Building Code and does not require an impact resistant covering. 4. When used in areas outside of the "HVHZ" requiring wind borne debris protection this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 5. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of drawing FL-15210.1 require further engineering analysis by a licensed engineer or registered architect. 7. Outswing configurations meet water infiltration requirements for "HVHZ". All other configurations do not meet the water infiltration requirements for the "HVHZ" and must be installed only in non -habitable areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. 8. See drawing FL-15210.1 for size and design pressure limitations Supporting Documents: 1. Test Report No. Test Standard TEL 01390365 TAS 201-94, 202-94 & TAB 203-94 TEL 01391846 TAB 201-94, 202-94 & TAS 203-94 ETC-05-255-16776.0 ASTM D 635-98. 638-03, 1929-96 & 2843-99 ASTM G 26-95 ETC-06-255-17412.0 ASTM E 84-05 ETC-07-209-19303.0 ASTM D 635-98, 638-03, 1929-96 & 2843-99 2. Drawing No. Prepared by No. FL-15210.1 RW Building Consultants, Inc. (CA #9813) 3. Calculations Prepared by Anchoring RW Building Consultants, Inc. (CA #9813) 4. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute, certifying that Plastpro, Inc. is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. Sheet 1 of 1 Testing Laboratory Testing Evaluation Lab., Inc. Testing Evaluation Lab., Inc. ETC Laboratories ETC Laboratories ETC Laboratories Signed by Lyndon F. Schmidt. P.E. William Shelton, P.E. Joseph L. Doldan, P.E. Joseph L. Doldan, P.E. Ben Meunier Signed & Sealed by Lyndon F. Schmidt, P.E. Signed & Sealed by Lyndon F. Schmidt, P.E. No 43409 in �ein fc 9 : STATE OF <trb;ls LyndonNo. 43409 FL PE �yaam 8/31/2017