Subject: Wind Load Design Pressure Calculations (Components & Cladding)
Site Information
Building Classification:
enclosed
Wind Speed (V It):
170 mph
Exposure Category:
d
Roof Type:
monoslope
Roof Slope (0):
1.2 deg
Mean Roof Height (h):
97.0 ft
Min. Building Dimension (L):
71.0 ft
Parapet >: 3 feet?
No
General Calculation
Directionality Factor (Kd):
0.85
Gust -Effect Factor (G):
0.85
Internal Pressure
Coefficient(GCpi . )•
±0.18
Topographical Factor (Kt):
1.0
Velocity Pressure Exposure
Coefficient ( nK):
1.43
Velocity Pressure (qh):
89.64 psf
End Zone (a):
7.1 ft
ASD Method:
P = 0.6w
klilll1111
NOTES: Design is in accordance with ASCE 7-10 (ASD method) and the Florida Building Code Sixth Edition (2017).
L) /e
are not valid for use unless approved via original signature and raised engineer seal of a PE from Engineering \Xp�
Results are based on contractor -supplied data and shall be field verified by others prior to use. Selection & in`tall�e"a7u'of N'•
Ono
Se
products shall be approved using these dimensions and pressures as verified by others.
=
.•I
PE82328
N
/
Note: For openings to be properly rated in Zone 4, no part of the opening shall be within 7.1 feet of any buAdIM corner.
Wed, FebrUi
This engineer has not field visited this location and if this cannot be clearly identified by others, the openings I be re-
don Di
Gordon
evaluatedpriortoinstallationofanyfenestration. All other information provided above including mean roof. h%
9T A OF
P
building minimum dimensions, opening sizes, &other supporting data was provided by others. For definitionf.o